Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "PFC" wg kryterium: Temat


Wyświetlanie 1-16 z 16
Tytuł:
Power factor correction algorithm in AC-DC converter
Algorytm korekcji współczynnika mocy PFC w przekształtniku AC-DC
Autorzy:
Mrozek, M.
Powiązania:
https://bibliotekanauki.pl/articles/257199.pdf
Data publikacji:
2013
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Technologii Eksploatacji - Państwowy Instytut Badawczy
Tematy:
power factor
power factor correction (PFC)
AC-DC converter
współczynnik mocy
korekcja współczynnika mocy PFC
przekształtnik AC-DC
Opis:
Power factor is a measure of the energy efficiency of the unit and corresponding losses in the transmission of electricity. Its value depends on the phase shift between voltage and current and the harmonic content of the supply current. In order to correct power factor circuits, the relevant passive or active circuits are used. This paper describes the algorithm for active power factor correction PFC control circuit AC-DC converter in the configuration step-up (boost) with continuous conduction current with the PWM modulation 20 kHz frequency. The results of studies of the dynamics of the converter are presented.
Współczynnik mocy PF (ang. Power Factor) jest miarą wykorzystania energii przez urządzenie i odpowiada stratom w przesyłaniu energii elek-trycznej. Jego wartość zależy od przesunięcia fazowego między napięciem a prądem oraz zawartości składowych harmonicznych prądu pobieranego z sieci. W celu korekcji współczynnika mocy stosuje się odpowiednie układy bierne lub aktywne. W artykule opisano algorytm aktywnej korekcji współczynnika mocy PFC (ang. Power Factor Correction) w układzie sterowania przekształtnikiem AC-DC w konfiguracji step-up (Boost) z przewodzeniem ciągłym prądu z modulacją PWM o częstotliwości 20 kHz. Przedstawiono wyniki badań dyna-miki przekształtnika.
Źródło:
Problemy Eksploatacji; 2013, 2; 129-139
1232-9312
Pojawia się w:
Problemy Eksploatacji
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Trójfazowy przekształtnik mocy AC/DC
Three-Phase Ac/Dc Power Converter
Autorzy:
Gospodarczyk, A.
Majcher, A.
Mrozek, M.
Powiązania:
https://bibliotekanauki.pl/articles/1368481.pdf
Data publikacji:
2013
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Napędów i Maszyn Elektrycznych Komel
Tematy:
trójfazowy przekształtnik AC/DC
układ korekcji współczynnika mocy (PFC)
three-phase AC/DC converter
Power Factor Correction (PFC)
Opis:
The article presents the design of a three-phase AC/DC power converter. The requirements and solutions used for this type of systems are described. The presented converter is made as full bridge and a halfcontrolled bridge circuits. The comparison of the results for the two solutions indicates higher utility of the full bridge circuit. The converter has a simple and a cost-effective design, complies with the normative requirements for harmonic emissions, the possibility of bidirectional flow of energy. The versatility of this converter allows for its application in three-phase energy conversion of permanent magnet generator to DC energy and its further processing to the public electricity AC network.
W artykule przedstawiono konstrukcję trójfazowego przekształtnika mocy AC/DC. Opisano wymagania oraz stosowane rozwiązania dla tego typu układów. Przedstawiony przekształtnik wykonano w topologii pełnego mostka oraz mostka pół-sterowanego. Porównanie wyników badań obu rozwiązań wskazuje na wyższą użyteczność układu mostkowego. Przekształtnik cechuje się prostą i tanią konstrukcją, zgodnością z wymaganiami normatywnymi emisji harmonicznych, możliwością dwukierunkowego przepływu energii. Uniwersalność opracowania pozwala na jego aplikację do konwersji trójfazowej energii prądnic z magnesami trwałymi na energię prądu stałego w celu jej dalszego przetwarzania na energię AC publicznej sieci zasilającej.
Źródło:
Maszyny Elektryczne: zeszyty problemowe; 2013, 2, 99; 219-225
0239-3646
2084-5618
Pojawia się w:
Maszyny Elektryczne: zeszyty problemowe
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analysis of Vienna rectifier
Autorzy:
Radomski, Cz.
Powiązania:
https://bibliotekanauki.pl/articles/262643.pdf
Data publikacji:
2005
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie
Tematy:
power electronics
electric power quality
PFC rectifiers
improving THD(i)
Opis:
It is common to find the inexpensive but robust electric power rectification method to lullil the demands of clean power conversion [1-12]. The Vienna rectifier structure [1] is one of the hopeful construction to fulfil these demands. It may be classified as the Clean Power Converter. It lets us obtain PFC rectification in simpler than the PWM converter system. The \ inina rectifier has three control points. In addition the Vienna rectifier is the three voltage level system with less current ripples than in the case of the PWM converter. However, it has some disadvantages. The Vienna rectifier system is an unidirectional converter. It can function onlv in the rectifier mode, the working in the inverter mode is impossible and the generation of the reactive power is strongly restricted. Usually the Vienna rectifier is controlled on the basis of the direct current control method [4,5,6]. However, this method is not perfect because it lets the improper control sequences appears. In this paper the mathematical model of the Vienna rectifier is derived. The voltage space vectors and their dependencies to the phase currents are denned. The range of the phase displacement angle and the maximum voltage space vector module v. phase displacement angle is drawn out for the case of the sinusoidal space vector modulation. The drawn out relations are proven by simulation results.
Źródło:
Electrical Power Quality and Utilisation. Journal; 2005, 11, 1; 49-56
1896-4672
Pojawia się w:
Electrical Power Quality and Utilisation. Journal
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Power supply with parallel reactive and distortion power compensation and tunable inductive filter – Part 1
Autorzy:
Gwóźdź, M.
Ciepliński, Ł.
Krystkowiak, M.
Powiązania:
https://bibliotekanauki.pl/articles/200798.pdf
Data publikacji:
2020
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
distortion power
PFC
power supply
reactive power
tunable inductive filter
Opis:
The work presents a DC power supply with power factor correction (PFC). This device is also equipped with a parallel active filter function, which enables the possibility of compensation (minimization) of reactive and distortion power, generated by a group of loads, connected to the same power grid node. A passive filter with variable inductance applied at the input of the power supply allows for a significantly improvement in quality of the system control (given specific criteria), as compared to the solution with a filter with fixed parameters. This is possible by increasing the dynamics of current changes at the power supply input (extending its “frequency response”). The paper presents the principle of operation as well as structures and models of the power supply control system and its power stage. Selected test results its power of the simulation model of the electric system with the power supply, in various operating conditions, are also presented.
Źródło:
Bulletin of the Polish Academy of Sciences. Technical Sciences; 2020, 68, 3; 401-408
0239-7528
Pojawia się w:
Bulletin of the Polish Academy of Sciences. Technical Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
An EL-model based passivity control of four-phase interleaved PFC
Autorzy:
Hua-Wu, L.
Hong-Xing, M.
Jian-Feng, J.
Xi-Jun, Y.
Xing-Hua, Y.
Powiązania:
https://bibliotekanauki.pl/articles/140472.pdf
Data publikacji:
2013
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
four-phase interleaved PFC
passivity based control
damping injection
current sparing
Opis:
With the continuous increase of output power ratings, multi-phase (multichannel) interleaved power factor corrector (IPFC) is gradually employed in domestic and commercial inverter air-conditioners. IPFC can solve several main problems, such as power rating increase, power device selection, input current ripple reduction as well as inductor on-board mounting. But for a multi-phase IPFC, the key problem is that it should show rapid dynamic responds and good current sharing capability, so in this paper the aim is to improve the dynamic performance and current sharing capability by means of passivity control theory. Considering the power circuit topology of a four-phase IPFC, an EL (Euler-Lagrange) mathematical model is established when the IPFC operates in continuous conduction mode (CCM). Then the passivity of the four-phase IPFC is proved, and the passivity-based controller using the state variables feedback and damping injection method is designed. The proposed control scheme, which is easy to control and needs no proportion integral controller, has strong robustness on disturbance from singlephase AC input voltage, the load as well as the parameters of the employed devices. Even in wide-range load condition, the mains current has a fast dynamic response and the average output voltage almost keep unchanged. As a result, the main functions of the four-phase IPFC are implemented including nearly unitary power factor and constant DC output voltage. Meanwhile, the four-phase IPFC acquires an excellent current sparing effect after using passivity-based controller. The above analysis has been proved with simulated results by means of MATLAB/SIMULINK and experimental results, showing that the passivity-based IPFC controller has superior performances and feasibility.
Źródło:
Archives of Electrical Engineering; 2013, 62, 4; 613-628
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Reconstruction of high-dimensional data using the method of probabilistic features combination
Autorzy:
Jakóbczak, D. J.
Powiązania:
https://bibliotekanauki.pl/articles/118528.pdf
Data publikacji:
2016
Wydawca:
Politechnika Koszalińska. Wydawnictwo Uczelniane
Tematy:
image retrieval
pattern recognition
data modeling
vector interpolation
PFC method
feature reconstruction
probabilistic modeling
pobieranie obrazu
rozpoznawanie wzorców
modelowanie danych
interpolacja wektora
metoda PFC
funkcja rekonstrukcji
modelowanie probabilistyczne
Opis:
Proposed method, called Probabilistic Features Combination (PFC), is the method of multi-dimensional data modeling, extrapolation and interpolation using the set of high-dimensional feature vectors. This method is a hybridization of numerical methods and probabilistic methods. Identification of faces or fingerprints need modeling and each model of the pattern is built by a choice of multi-dimensional probability distribution function and feature combination. PFC modeling via nodes combination and parameter γ as N-dimensional probability distribution function enables data parameterization and interpolation for feature vectors. Multidimensional data is modeled and interpolated via nodes combination and different functions as probability distribution functions for each feature treated as random variable: polynomial, sine, cosine, tangent, cotangent, logarithm, exponent, arc sin, arc cos, arc tan, arc cot or power function.
Autorska metoda Probabilistycznej Kombinacji Cech - Probabilistic Features Combination (PFC) jest wykorzystywana do interpolacji i modelowania wielowymiarowych danych. Węzły traktowane są jako punkty charakterystyczne N-wymiarowej informacji, która ma być odtwarzana (np. obraz). Wielowymiarowe dane są interpolowane lub rekonstruowane z wykorzystaniem funkcji rozkładu prawdopodobieństwa: potęgowych, wielomianowych, wykładniczych, logarytmicznych, trygonometrycznych, cyklometrycznych.
Źródło:
Zeszyty Naukowe Wydziału Elektroniki i Informatyki Politechniki Koszalińskiej; 2016, 9; 37-50
1897-7421
Pojawia się w:
Zeszyty Naukowe Wydziału Elektroniki i Informatyki Politechniki Koszalińskiej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Effect of an eccentric decoupled charge on rock mass blasting
Autorzy:
Kim, Jung-Gyu
Ali, Mahrous A.M.
Kim, Jong-Gwan
Powiązania:
https://bibliotekanauki.pl/articles/1839045.pdf
Data publikacji:
2020
Wydawca:
Główny Instytut Górnictwa
Tematy:
eccentric decoupled charge
fracture pattern
PFC
AUTODYN
decoupling index
wzór pęknięcia
wskaźnik odsprzęgania
Opis:
Experimental and numerical analyses were conducted to investigate the effect of an eccentric loaded contour hole on a rock mass. In the concrete blocks used for the analyses, detonating cords were placed at the centre of the blast hole and eccentrically against the wall of the blast hole. PFC2D and AUTODYN were used for the numerical analyses, and the results of these software showed that an eccentric decoupled charge can result in the directional development of fractures, thereby enabling the control of cracks in the opposite direction. Even though both types of blasting have identical decoupling indexes, the crack and fracture patterns were affected by the location of the explosive, tamping, and other conditions. The results showed that an eccentric charge holder can be applicable to control the fracture direction and the damaged zone. For an eccentric charge, the initial crack was generated at 0.01 ms and expanded in the intended direction. For the eccentric charge, the maximum pressure at the area in contact with the blast hole wall exceeded that for the central decoupled charge by a factor of 5.5. Furthermore, the pressure in the intended direction was twice of that in the opposite direction.
Źródło:
Journal of Sustainable Mining; 2020, 19, 1; 1-10
2300-1364
2300-3960
Pojawia się w:
Journal of Sustainable Mining
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Research on a laboratory technique for tire-pavement noise assessment of asphalt mixes
Autorzy:
Kowalski, K. J.
Dare, T.
McDaniel, R. S.
Olek, J.
Bernhard, R.
Powiązania:
https://bibliotekanauki.pl/articles/230927.pdf
Data publikacji:
2013
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
hałas
interakcja opona-nawierzchnia
SMA
PFC
DGA
nawierzchnia asfaltowa
noise
tire-pavement interaction
asphalt pavement
Opis:
Communication noise is classified as one of the pollutions for the current environment. Experimental techniques to measure tire-pavement noise generation from asphalt pavements in the laboratory have been limited. A series of experiments were conducted on six different asphalt mixtures to determine if Purdue University’s Tire-Pavement Test Apparatus (TPTA) could be used to overcome these limitations. The procedure produced samples with low tire-pavement noise; however, the air void contents of the samples were higher than designed. Despite these difficulties, the sample preparation technique and the TPTA testing protocol were shown to offer an effective approach for quick laboratory assessment of tire-pavement noise characteristics of hot mix asphalt pavements at a substantially reduced cost compared to field testing.
Źródło:
Archives of Civil Engineering; 2013, 59, 4; 561-577
1230-2945
Pojawia się w:
Archives of Civil Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Optimisation of selected parameters of the shield support base dedicated for the condition of a weak floor
Autorzy:
Rajwa, Sylwester
Bock, Sven
Powiązania:
https://bibliotekanauki.pl/articles/2203341.pdf
Data publikacji:
2022
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
modelowanie numeryczne
eksploatacja węgla
podpora hydrauliczna
numerical modelling
PFC3D
shield support
longwall mining
Opis:
In longwall coal exploitation, problems with the proper functioning of the powered shield support often occur. In many cases, it results from the insufficient load-bearing capacity of the ground (floor) and the inability to achieve the set or yield pressure of the shield support. The improper functioning of the shield support may also result from its construction and the lack of optimisation to work effectively on a weak mine floor. This paper presents an attempt to optimise the operating conditions of the base of two-legged shield support based on the field observations and results of the PFC3D numerical calculation. In the framework of the numerical calculations, the impact of the width of the base and the location of the hydraulic legs on the working conditions of shield support on a weak floor were analysed.
Źródło:
Archives of Mining Sciences; 2022, 67, 3; 509--529
0860-7001
Pojawia się w:
Archives of Mining Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Measuring displacement and contact forces among the particles in unloading of slope by PFC2D (Particle Flow Code)
Pomiary przemieszczeń i sił kontaktu pomiędzy cząstkami materialnymi w trakcie wybierania wyrobiska pochyłego przy pomocy programu PFC2D
Autorzy:
Behbahani, S. S.
Moarefvand, P.
Ahangari, K.
Goshtasbi, K.
Powiązania:
https://bibliotekanauki.pl/articles/218770.pdf
Data publikacji:
2013
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
wybieranie
metoda elementów dyskretnych
przemieszczające się masy gruntu
unloading
Discrete Element Method (DEM)
sliding mass
PFC2D
Opis:
When instability is observed in the walls of open pit mining, at this time, engineers are faced with a moving mass which is a combination of materials that move on each other and on the main slip surface. Modeling of this movement can have an effective assistance to mining engineers to predict the movement behavior, displacement estimate, and the moving volumes. One of the suitable software which is capable of modeling of sliding behavior is PFC (Particle Flow Code). It is based on Discrete Element Method and released by the Itasca Company. In this paper, the modeling of sliding mass and unloading it in seven stages have been done. During the seven stages of unloading the maximum displacement and maximum contact forces among the particles are obtained. Maximum displacement happened in the fifth stage of the unloading and it is equal to 134.8 meters. Maximum contact forces occurred in the first stage of the unloading after initial equilibrium stage and it is equal to 1917 kN. The model for unloading of sliding mass presented in this paper is just an example and it is not a definite model for unloading of each sliding mass. Unloading of sliding mass depends on the situation of sliding mass and its volume and also mining limitations.
W przypadku wystąpienia niestabilności ścian pochyłego wyrobiska odkrywkowego, inżynierowie mają do czynienia z przemieszczającą się masa - będącą kombinacją materiałów przesuwających się względem siebie a także zsuwających się w dół po powierzchni spadu. Modelowanie tego ruchu może znacznie pomóc inżynierom-górnikom w prognozowaniu zachowań terenu w trakcie tego ruchu, do szacowania wielkości przemieszczeń i objętości przemieszczających się mas materiału. Jednym z programów wspomagających modelowanie przemieszczeń tego typu jest oprogramowanie Particle Flow Code PFC, rozprowadzane przez firmę Itasca, wykorzystujące metodę elementów dyskretnych. W pracy tej przeprowadzono modelowanie ruchu przesuwających się mas gruntu i wybierania wyrobiska pochyłego w siedmiu etapach. We wszystkich siedmiu etapach modelowania obliczono maksymalne przemieszczenia i siły kontaktowe pomiędzy cząstkami gruntu. Maksymalne przemieszczenia zarejestrowano w etapie piątym wybierania wyrobiska pochyłego, wyniosło ono 134.8 m. Maksymalna siła kontaktowe, która wystąpiła w etapie pierwszym po ustaniu pierwotnego stanu równowagi, wyniosła 1917 kN. Model wybierania przesuwającej się masy gruntu przedstawiony w pracy jest jedynie przykładem, nie jest to ścisły model mający zastosowanie do modelowania ruchu przesuwających się mas gruntu w trakcie wybierania. Wybieranie przesuwających się mas gruntu zależy od warunków przemieszczania się masy gruntu, jej objętości a także ograniczeń narzuconych przez uwarunkowania górnicze.
Źródło:
Archives of Mining Sciences; 2013, 58, 2; 495-504
0860-7001
Pojawia się w:
Archives of Mining Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Power supply with parallel reactive and distortion power compensation and tunable inductive filter — Part 2
Autorzy:
Gwóźdź, Michał
Wojciechowski, Rafał
Ciepliński, Łukasz
Powiązania:
https://bibliotekanauki.pl/articles/2086834.pdf
Data publikacji:
2021
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
distortion power
PFC
power supply
reactive power
tunable inductive filter
moc zniekształceń
zasilacz
reaktywna moc
przestrajalny filtr indukcyjny
Opis:
The paper is the second part of the work, devoted to a DC power supply with a power factor correction function. The power supply is equipped additionally with a shunt active power filter function, which enables the compensation of reactive and distortion power, generated by loads, connected to the same power grid node. A tunable inductive filter, included at the input of the power electronics current source – the main block of the power supply – allows for an improvement of the quality of the system control, compared to the device with a fixed inductive filter. This improvement was possible by extending the current source “frequency response”, which facilitated increasing the dynamics of current changes at the power supply input. The second part of the work briefly reminds the reader of the principle of operation and the structures of both the power supply control system and its power stage. The main purpose of this paper is to present the selected test results of the laboratory model of the electric system with the power supply.
Źródło:
Bulletin of the Polish Academy of Sciences. Technical Sciences; 2021, 69, 4; e137938, 1--9
0239-7528
Pojawia się w:
Bulletin of the Polish Academy of Sciences. Technical Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Układ sterowania przekształtnikiem AC-DC z funkcją korekcji współczynnika mocy PFC
A control system for AC-DC converter with the function of a power factor correction PFC
Autorzy:
Mrozek, M.
Powiązania:
https://bibliotekanauki.pl/articles/257187.pdf
Data publikacji:
2012
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Technologii Eksploatacji - Państwowy Instytut Badawczy
Tematy:
współczynnik mocy
przekształtnik AC-DC
korekcja współczynnika mocy
PFC
Power Factor Correction
power factor
AC-DC converter
power factor correction
Opis:
Jedną z miar odpowiedniego wykorzystania energii w zasilaczach impulsowych jest współczynnik mocy (PF). Wpływ na wartość tego współczynnika ma przesunięcie fazowe między napięciem a prądem, a także zawartość składowych harmonicznych prądu pobieranego z sieci. W celu korekcji współczynnika mocy stosuje się odpowiednie układy bierne lub aktywne. W artykule opisano mikroprocesorowy układ sterowania przetwornicą AC-DC z funkcją aktywnej korekcji współczynnika mocy PFC (ang. Power Factor Correction). Opisano strukturę przekształtnika AC-DC bazującego na topologii przekształtnika DC-DC step-up (Boost) przy założeniu ciągłego prądu dławika modulacji PWM o częstotliwości 20 kHz.
One of the measures of the appropriate use of energy in a pulsed power supply is the power factor (PF), which corresponds to losses in the transmission of electricity. The phase shift has an influence on the power factor between voltage and current as well as the content of power system harmonics taken from power mains. To correct the power factor, one should use a suitable passive or active circuit. The microprocessor control system of an AC-DC converter with an active power factor correction function is presented in the article. The general structure of a controller and an algorithm of controlling PFC in topology step-up (Boost) with a continuous conduction mode and modulation PWM and frequency 20 kHz is described.
Źródło:
Problemy Eksploatacji; 2012, 3; 145-154
1232-9312
Pojawia się w:
Problemy Eksploatacji
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Particle Flow Code modeling of the mechanical behavior of layered rock under uniaxial compression
Modelowanie właściwości mechanicznych skał warstwowych w warunkach ściskania jednoosiowego przy zastosowaniu oprogramowania Particle Flow Code(PFC)
Autorzy:
Yao, Nan
Ye, Yi-Cheng
Hu, Bin
Wang, Wei-Qi
Wang, Qi-Hu
Powiązania:
https://bibliotekanauki.pl/articles/218969.pdf
Data publikacji:
2019
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
skała warstwowa
wytrzymałość na ściskanie jednoosiowe
Particle Flow Code (PFC)
kąt uwarstwienia
mikropęknięcia
layered rock
uniaxial compression test
bedding angle
microcracks
Opis:
In this paper, the different mechanical behaviors of layered rocks with different bedding angles during uniaxial compression tests are studied. Numerical simulation models of layered rock are validated based on laboratory tests, and uniaxial compression tests are conducted by using Particle Flow Code (PFC). Using these simulations, the uniaxial compressive strength, failure patterns, development of micro-cracks, and displacement of meso particles are analyzed. When the bedding angle is similar to the failure angle, the macro failure planes develop directly along the beddings, the bedding behavior dictates the behavior of the layered rock, reducing the compressive strength.
W pracy badano właściwości mechaniczne skał warstwowych zalegających pod różnym kątem uwarstwienia w warunkach ściskania jednoosiowego. Walidację modeli symulacyjnych skał warstwowych przeprowadzono w oparciu o wyniki badań laboratoryjnych, zaś testy ściskania jednoosiowego prowadzono z użyciem pakietu Particle Flow Code (PFC). W oparciu o badania symulacyjne, analizowano wytrzy-małość skał na ściskanie jednoosiowe, modele pękania, powstawanie mikropęknięć i przemieszczenia mezo- cząstek. W przypadku gdy kąt płaszczyzny uwarstwienia ma wartość przybliżoną do kąta pęknięcia, płaszczyzny pękania w skali makro pojawiają się wzdłuż spękań, a układ warstw skalnych determinuje ich wytrzymałość na ściskanie, powodując jej obniżenie.
Źródło:
Archives of Mining Sciences; 2019, 64, 1; 181-196
0860-7001
Pojawia się w:
Archives of Mining Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Investigation of a High-efficiency and High-frequency 10-kW/800-V Three-phase PWM Converter with Direct Power Factor Control
Autorzy:
Barlik, Roman
Grzejszczak, Piotr
Leszczyński, Bernard
Szymczak, Marek
Powiązania:
https://bibliotekanauki.pl/articles/226672.pdf
Data publikacji:
2019
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
three-phase PWM rectifier
reactive power compensator
silicon carbide MOSFET
bidirectional power flow
direct power control (DPC)
DC voltage regulation
power factor correction (PFC)
LCL filter
Opis:
The paper presents a concept of a control system for a high-frequency three-phase PWM grid-tied converter (3x400 V / 50 Hz) that performs functions of a 10-kW DC power supply with voltage range of 600÷800 V and of a reactive power compensator. Simulation tests (in PLECS) allowed proper selection of semiconductor switches between fast IGBTs and silicon carbide MOSFETs. As the main criterion minimum amount of power losses in semiconductor devices was adopted. Switching frequency of at least 40 kHz was used with the aim of minimizing size of passive filters (chokes, capacitors) both on the AC side and on the DC side. Simulation results have been confirmed in experimental studies of the PWM converter, the power factor of which (inductive and capacitive) could be regulated in range from 0.7 to 1.0 with THDi of line currents below 5% and energy efficiency of approximately 98.5%. The control system was implemented in Texas Instruments TMS320F28377S microcontroller.
Źródło:
International Journal of Electronics and Telecommunications; 2019, 65, 4; 619-624
2300-1933
Pojawia się w:
International Journal of Electronics and Telecommunications
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Simulation study on strength and failure characteristics of coal-rock composite sample with coal persistent joint
Badanie symulacyjne charakterystyk wytrzymałościowych próbki kompozytowej złożonej z materiału skalnego oraz węgla w którym występują płaszczyzny łupliwości
Autorzy:
Yin, Dawei
Chen, Shaojie
Chen, Bing
Xia, Zhiguo
Powiązania:
https://bibliotekanauki.pl/articles/219275.pdf
Data publikacji:
2019
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
symulacja PFC
próbka kompozytowa złożona z węgla i materiału skalnego
spoistość węgla
charakterystyka wytrzymałościowa
ewolucja mikro-pęknięć
particle flow simulation
coal-rock composite sample
coal persistent joint
strength and failure characteristics
microcrack number evolution
Opis:
Dynamic Mine disasters can be induced by the instability and failure of a composite structure of rock and coal layers during coal mining. Coal seam contains many native defects, severely affecting the instability and failure of the compound structure. In this study, the effects of coal persistent joint on the strength and failure characteristics of coal-rock composite samples were evaluated using PFC2D software. The results show that with the increase of included angle α between the loading direction and joint plane direction, the uniaxial compressive stress (UCS) and peak strain of composite samples first decrease and then gradually increase. The elastic moduli of composite samples do not change obviously with α. The peak strain at α of 45° is the lowest, and the UCS at α of 30° is the smallest. This is inconsistent with theoretical analysis of lowest UCS at α of 45°. This is because that the local stress concentration caused by the motion inconformity of composite samples may increase the average axial stress of upper wall in PFC2D software. Moreover, the coal persistent joint promotes the transformation from the unstable crack expansion to the macro-instability of composite samples, especially at α of 30° and 45°. The majority of failures for composite samples occur within the coal, and no obvious damage is observed in rock. Their failure modes are shear failure crossing or along the coal persistent joint. The failure of composite sample at α of 30° is a mixed failure, including the shear failure along the persistent joint in coal and tensile failure of rock induced by the propagation of coal persistent joint.
Niekorzystne zjawiska dynamiczne w kopalniach mogą być wywołane przez niestabilność i pękanie struktur kompozytowych złożonych z warstw węgla i materiałów skalnych w trakcie eksploatacji górniczej. W złożu węgla ujawnić się mogą liczne defekty wewnętrzne, które w poważnym stopniu rzutują na stabilność i wytrzymałość złożonej struktury. W pracy tej zbadano wpływ spoistości węglu (występowania powierzchni łupliwości) na charakterystykę wytrzymałościową próbki kompozytowej złożonej z węgla i skały z wykorzystaniem oprogramowania PCF 2D. Wyniki symulacji wskazują, że wraz ze wzrostem kąta α pomiędzy kierunkiem działania obciążenia a płaszczyzną łupliwości, jednoosiowe naprężenie ściskające oraz maksymalne odkształcenie próbki kompozytowej w pierwszym etapie zmniejszą się, a następnie zaczną stopniowo wzrastać. Moduł sprężystości próbek kompozytowych nie ulega zmianie wraz ze zmianą kąta α. Maksymalne odkształcenie będzie najmniejsze dla kąta α równego 45°, z kolei jednoosiowe naprężenie ściskające zarejestrowane dla 30° okaże się najniższe. Wyniki te nie wykazują zgodności z wynikami analiz teoretycznych, przewidujących iż najniższe wartości jednoosiowego naprężenia ściskającego powinny wystąpić dla kąta 45°. Dzieje się tak dlatego, że lokalne koncentracje naprężeń wskutek odmienności zachowania poszczególnych składników próbki w trakcie ruchu powodować mogą wzrost średniego naprężenia osiowego ściany górnej, co uwzględnia model z wykorzystaniem oprogramowania PFC 2D. Ponadto, istnienie ciosu i płaszczyzn łupliwości sprawia, że niestabilne i propagujące szczeliny ulegają przekształceniu w makro- niestabilności próbek kompozytowych, zwłaszcza przy kącie α równym 30° i 45°. Większość pęknięć powstających w próbkach kompozytowych występuje w części węglowej, w pozostałych skałach nie notuje się poważniejszych uszkodzeń. Pęknięcia zmęczeniowe w części złożonej z materiału skalnego odbywają się wskutek działania naprężeń ścinających wzdłuż lub w poprzez płaszczyzny łupliwości. Pękanie zmęczeniowe próbki kompozytowej przy kącie α równym 30° jest procesem złożonym, obejmującym pękanie wskutek naprężeń ścinających działających wzdłuż płaszczyzny łupliwości w węglu oraz naprężeń rozciągających działających na część próbki złożoną z materiału skalnego, wskutek propagacji pęknięcia.
Źródło:
Archives of Mining Sciences; 2019, 64, 3; 609-623
0860-7001
Pojawia się w:
Archives of Mining Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wpływ uregulowań unijnych dotyczących postępowania z F-gazami na krajowy rynek urządzeń gaśniczych
Influence of EU regulations concerning handling of f-gases on their use in gas extinguishing systems
Autorzy:
Zbrożek, P.
Kiełbasa, T.
Powiązania:
https://bibliotekanauki.pl/articles/373129.pdf
Data publikacji:
2011
Wydawca:
Centrum Naukowo-Badawcze Ochrony Przeciwpożarowej im. Józefa Tuliszkowskiego
Tematy:
chlorowcopochodne węglowodorów
F-gazy
fluoriwane gazy cieplarniane
globalne ocieplenie
GWP
HFC
ograniczenie emisji
operator systemu
perfluorowęglowodory
PFC
urządzenia gaśnicze
wodorofluorowęglowodory
emission reduction
extinguishing devices
F-gases
fluorinated greenhouse gases
global warming
halocarbons
halofluorocarbons
perfluorocarbons
system operator
Opis:
W artykule przedstawiono uregulowania prawne dotyczące F-gazów wykorzystywanych w ochronie przeciwpożarowej. Omówiono stosowanie F-gazów oraz konsekwencje nowych uregulowań dla branży przeciwpożarowej. Zarysowano prognozy rozwoju urządzeń gaśniczych wykorzystujących F-gazy oraz przedstawiono rozwiązania alternatywne.
In the article there are described legal regulations concerning F-gases used in fire protection. F-gases use is discussed together with consequences of new regulations of fire protection industry. Forecasts of development of firefighting devices using F-gases are outlined and alternative solutions are presented.
Źródło:
Bezpieczeństwo i Technika Pożarnicza; 2011, 1; 105-116
1895-8443
Pojawia się w:
Bezpieczeństwo i Technika Pożarnicza
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-16 z 16

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies