Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "Outdoor" wg kryterium: Temat


Tytuł:
A System for Measuring Vertical Concentration Profiles of Gaseous Pollutants, Using Carbon Dioxide as a Case Study
Autorzy:
Micallef, A.
Deuchar, C. N.
Colls, J. J.
Powiązania:
https://bibliotekanauki.pl/articles/91042.pdf
Data publikacji:
1998
Wydawca:
Centralny Instytut Ochrony Pracy
Tematy:
concentration gradient
spatial distribution
multi-level sampling
human exposure
indoor-outdoor air pollution
gradient stężenia
rozkład przestrzenny
zanieczyszczenia gazowe
Opis:
An electronically-controlled sampling system, characterised by its organ pipe design, has been developed for sampling air sequentially, at different heights within the breathing zone. Data are automatically logged at the different receptor levels, for the determination of the average vertical concentration profile of gaseous pollutants. The system has been coupled to a carbon dioxide monitor and used in a brief study of the spatial and temporal variation of indoor carbon dioxide concentration. The system can easily be extended for different heights or modified for use with other types of gas monitor. The results of a trial run, which was carried out in a coffee room, are presented and applications of the Organ Pipe Sequential Sampling (OPSS) system are discussed.
Źródło:
International Journal of Occupational Safety and Ergonomics; 1998, 4, 3; 333-346
1080-3548
Pojawia się w:
International Journal of Occupational Safety and Ergonomics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Dense 3D Structure and Motion Estimation as an Aid for Robot Navigation
Autorzy:
De Cubber, G.
Powiązania:
https://bibliotekanauki.pl/articles/384899.pdf
Data publikacji:
2008
Wydawca:
Sieć Badawcza Łukasiewicz - Przemysłowy Instytut Automatyki i Pomiarów
Tematy:
outdoor mobile robots
behavior-based control
stereo vision and image motion analysis for robot navigation
modular control and software architecture (MCA)
Opis:
Three-dimensional scene reconstruction is an important tool in many applications varying from computer graphics to mobile robot navigation. In this paper, we focus on the robotics application, where the goal is to estimate the 3D rigid motion of a mobile robot and to reconstruct a dense three-dimensional scene representation. The reconstruction problem can be subdivided into a number of subproblems. First, the egomotion has to be estimated. For this, the camera (or robot) motion parameters are iteratively estimated by reconstruction of the epipolar geometry. Secondly, a dense depth map is calculated by fusing sparse depth information from point features and dense motion information from the optical flow in a variational framework. This depth map corresponds to a point cloud in 3D space, which can then be converted into a model to extract information for the robot navigation algorithm. Here, we present an integrated approach for the structure and egomotion estimation problem.
Źródło:
Journal of Automation Mobile Robotics and Intelligent Systems; 2008, 2, 4; 14-18
1897-8649
2080-2145
Pojawia się w:
Journal of Automation Mobile Robotics and Intelligent Systems
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Exposure to the airborne mould Botrytis and its health effects
Autorzy:
Jurgensen, C W
Madsen, A.M.
Powiązania:
https://bibliotekanauki.pl/articles/49724.pdf
Data publikacji:
2009
Wydawca:
Instytut Medycyny Wsi
Tematy:
healthy effect
allergy
Botrytis
fungi
indoor air
mould
occupational exposure
outdoor air
season
spore calendar
asthma
human disease
Źródło:
Annals of Agricultural and Environmental Medicine; 2009, 16, 2; 183-196
1232-1966
Pojawia się w:
Annals of Agricultural and Environmental Medicine
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Feasibility of using heat-recovery exchangers in livestock buildings at a site at a specific altitude with a specific average outdoor air temperature
Autorzy:
Sleger, V.
Neuberger, P.
Polak, M.
Powiązania:
https://bibliotekanauki.pl/articles/62353.pdf
Data publikacji:
2009
Wydawca:
Polska Akademia Nauk. Stowarzyszenie Infrastruktura i Ekologia Terenów Wiejskich PAN
Tematy:
feasibility
heat-recovery exchanger
livestock building
outdoor air temperature
climate condition
Czech Republic
agriculture
air temperature
weather station
ventilation
air exchange
heat exchanger
Opis:
The installation of an energy-saving facility must be preceded by analysis of its financial effectiveness. Among methods enabling such evaluation is the basic net profit calculation method. For this, the annual consumption of electricity for ventilation or of thermal energy for heating must be determined. The calculation formula uses the sum of energies for temperatures within the range from the calculation temperature for the area in question to the long-term average of the maximum temperature at the site, or to the temperature at which the heating power is zero. It is necessary to know the summary time of occurrence of a given temperature during a year. The site data can only be assessed based on long-term meteorological information. In fact, data used by current national standards to describe climatic conditions in the Czech Republic are from the years 1901 to 1950. The dependence of the average yearly temperature on altitude is shown in Fig. 1 for the 1961 1990 and 1991 2000 periods. It is evident that the average temperatures for the latter period are nearly 0.6 K higher than those for the former period, irrespective of the altitude. In this paper the climatic conditions are assessed based on daily data measured throughout the period from 1 January 1991 to 31 December 2000. Weather stations were selected so as to achieve a uniform coverage and continuity of measurement at each site (as far as possible). All the stations lie in the Czech Republic between 48.8° and 50.8° north latitude at altitudes from 158 m to 1324 m. It was the objective of this examination, based on the meteorological data collected to calculate the average number of days and hours during which the temperature during the year is lower than a specific limiting level, in dependence on the average yearly temperature of the site. Fig. 3 shows the average number of days in a year during which a temperature lower than a selected limiting level occurs, as calculated for the 1991 2000 period. The results are presented for 4 areas with average yearly temperatures of 6 °C 7 °C, 7 °C 8 °C, 8 °C 9 °C, and 9 °C 10 °C, respectively. The graphs enables us to ascertain the number of days during which a heating facility is in operation if the facility is activated by outdoor air temperature decrease to below a specific limiting level. If a typical daily temperature wave is considered, the method makes it possible to estimate the number of hours during which the air temperature is lower than the limiting level chosen. The difference between the data for various limiting levels allows us, for an area with a specific average yearly temperature to ascertain the time of occurrence of outdoor temperature within various ranges. The results of calculations are shown in Fig. 4 and Table 1. The method applied enables underlying data to be prepared for the assessment of energy demands for air heating at a given site and for estimation of the energy savings that could be achieved by installing economical air heating facilities in livestock buildings.
Źródło:
Infrastruktura i Ekologia Terenów Wiejskich; 2009, 07
1732-5587
Pojawia się w:
Infrastruktura i Ekologia Terenów Wiejskich
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies