Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "Orthopaedic Surgery" wg kryterium: Temat


Wyświetlanie 1-6 z 6
Tytuł:
A Novel Method for Calculation of Knee Deformation Angles in Clinical and Sport Biomechanics
Autorzy:
Haddas, Ram
Powiązania:
https://bibliotekanauki.pl/articles/1054895.pdf
Data publikacji:
2016
Wydawca:
Uniwersytet Szczeciński. Wydawnictwo Naukowe Uniwersytetu Szczecińskiego
Tematy:
Cutting Maneuver
Joint Architecture
Kinematic
Knee Deformation
Knee Injuries
Orthopaedic Surgery
Opis:
Biomechanical analyses seek to improve understanding of the mechanisms of knee injury and to find ways to reduce knee injury incidence. Many clinical biomechanics researchers use a standard kinematic adopted from Newington Children’s Hospital. Biomechanical studies include the knee joint configurations, where joint architecture immutably constrains and guides movement outcomes. Investigators will default to reporting resultant joint deformation without considering the influence of joint architectural configurations on kinematic responses. The purpose of this study was to develop a new joint angular kinematic method that accounts for influence of dynamic joint architectural configuration on deformation values. Twenty subjects performed unloaded dynamic flexion/ extension and 45° cutting maneuver. The knee deformation angles obtained with the new method proposed were compared with the values that obtained using the standard method. One way repeated measurement ANOVA’s was used to compare knee deformation angles values from the standard method that uses a static trial and the new method that uses a dynamic trial. The proposed method distinguishes between dynamic joint architectural configuration and joint deformation. Loaded standard abduction/adduction (β) and rotation (γ) angles were 3.4 ±1.8° and 11.2 ±3.8°, respectively. Using the new method, the β and γ angles decrease to 1.5 ±1.4° (<0.05) and 7.1 ±1.8° (<0.05) during cutting. The new method accounted for dynamic joint architectural configuration produced loaded β and γ angles that had smaller magnitudes than the standard method, suggesting that previous studies may have overestimated β and γ angles. Injury management strategies could be influenced by a consideration for dynamic joint architectural configuration. Such a consideration could influence ligament repair strategies. Future studies should account for dynamic configuration when establishing the influence of joint deformation on graft design and appropriate isometry values during reconstruction.
Źródło:
Central European Journal of Sport Sciences and Medicine; 2016, 13, 1; 5-13
2300-9705
2353-2807
Pojawia się w:
Central European Journal of Sport Sciences and Medicine
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Applications of modern imaging technology in orthopaedic trauma surgery
Autorzy:
Krakowski, Przemysław
Karpiński, Robert
Maciejewski, Marcin
Powiązania:
https://bibliotekanauki.pl/articles/117796.pdf
Data publikacji:
2018
Wydawca:
Polskie Towarzystwo Promocji Wiedzy
Tematy:
medical imaging
3D reconstruction
orthopaedic trauma surgery
obrazowanie
rekonstrukcja 3D
uraz ortopedyczny
Opis:
Orthopaedic trauma surgery is a complex surgical speciality in which anatomy, physiology and physics are mixed. Proper diagnosing and based on that planning and performing surgery is of crucial matter. This article briefly summarizes available radiological modalities used for diagnostics and for surgical planning. It focuses on utility of rapid prototyping process in trauma surgery. Moreover, a case study in which this technique was used is described. Rapid prototyping proved its usefulness and in future it may become a modality of choice for planning complex trauma procedures.
Źródło:
Applied Computer Science; 2018, 14, 3; 96-106
1895-3735
Pojawia się w:
Applied Computer Science
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Drilling resistance : A method to investigate bone quality
Autorzy:
Lughmani, W. A.
Farukh, F.
Bouazza-Marouf, K.
Ali, H.
Powiązania:
https://bibliotekanauki.pl/articles/306405.pdf
Data publikacji:
2017
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
chirurgia ortopedyczna
wiercenie
gęstość mineralna kości
jakość kości
bone drilling
orthopaedic surgery
screw pull-out strength
bone mineral density
bone quality
Opis:
Purpose: Bone drilling is a major part of orthopaedic surgery performed during the internal fixation of fractured bones. At present, information related to drilling force, drilling torque, rate of drill-bit penetration and drill-bit rotational speed is not available to orthopaedic surgeons, clinicians and researchers as bone drilling is performed manually. Methods: This study demonstrates that bone drilling force data if recorded in-vivo, during the repair of bone fractures, can provide information about the quality of the bone. To understand the variability and anisotropic behaviour of cortical bone tissue, specimens cut from three anatomic positions of pig and bovine were investigated at the same drilling speed and feed rate. Results: The experimental results showed that the drilling force does not only vary from one animal bone to another, but also vary within the same bone due to its changing microstructure. Drilling force does not give a direct indication of bone quality; therefore it has been correlated with screw pull-out force to provide a realistic estimation of the bone quality. A significantly high value of correlation (r 2 = 0.93 for pig bones and r 2 = 0.88 for bovine bones) between maximum drilling force and normalised screw pull-out strength was found. Conclusions: The results show that drilling data can be used to indicate bone quality during orthopaedic surgery.
Źródło:
Acta of Bioengineering and Biomechanics; 2017, 19, 1; 55-62
1509-409X
2450-6303
Pojawia się w:
Acta of Bioengineering and Biomechanics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Methods for designing and fabrication large-size medical models for orthopaedics
Autorzy:
Kudasik, T.
Libura, M.
Markowska, O.
Miechowicz, S.
Powiązania:
https://bibliotekanauki.pl/articles/200776.pdf
Data publikacji:
2015
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
computed tomography
CT
orthopaedic surgery
computer assisted surgery
CAS
rapid prototyping
RP
Opis:
Computed tomography and rapid prototyping techniques can be used to construct and fabricate large size bone models for orthopaedics. Rapid Prototyping technology enables the fabrication of a true-to-scale bone joint model based on 3D virtual models, generated by segmenting patients’ CT images. The model can be used to plan, to simulate, to assist prosthesis implantation for difficult cases of THR (Total Hip Replacements). The main restriction of implementing such models into medical practice is high cost of their production. Physical models of pelvic bones, were constructed on the basis of data collected during standard CT examinations. A method of development of a large-size model while fulfilling the requirement for reducing the price of model fabrication in the article was presented. The method can be used for fabrication the models with 3DP technique. This paper also discusses the issue of production costs when utilizing other RP techniques as well as their usefulness in practice.
Źródło:
Bulletin of the Polish Academy of Sciences. Technical Sciences; 2015, 63, 3; 623-627
0239-7528
Pojawia się w:
Bulletin of the Polish Academy of Sciences. Technical Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Modelling and optimization of temperature in orthopaedic drilling : An in vitro study
Autorzy:
Pandey, R. K.
Panda, S. S.
Powiązania:
https://bibliotekanauki.pl/articles/307028.pdf
Data publikacji:
2014
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
analysis of variance
ANOVA
orthopaedic surgery
response surface methodology
Taguchi method
thermal osteonecrosis
analiza wariancji
chirurgia ortopedyczna
metoda Taguchi
Opis:
This present investigation uses the Taguchi and response surface methodology (RSM) for modelling and optimization of the temperature produced during bone drilling. The drilling of bone is a common procedure in orthopaedic surgery to produce hole for screw insertion to fixate the fracture devices and implants. A major problem which is encountered during such a procedure is the increase in temperature of the bone due to the plastic deformation of chips and the friction between the bone and the drill. The increase in temperature can result in thermal osteonecrosis which may delay healing or reduce the stability and strength of the fixation. The drilling experiments are conducted on poly-methyl-meth-acrylate (PMMA) (as a substitute for bone) using Taguchi’s L27 experimental design technique. The cutting parameters used are drill diameter, feed rate and cutting speed. The optimum cutting parameters for minimum temperature are determined by using S/N ratios and the effect of individual cutting parameters on temperature produced is evaluated using analysis of variance (ANOVA). A second-order model is established between the drilling parameters and temperature using RSM. The experimental results show that the drill diameter is the most significant drilling parameter affecting the temperature during drilling followed by cutting speed and feed, respectively. The values predicted and the values obtained from experiment are fairly close, which indicates that the developed RSM model can be effectively used to predict the temperature in orthopaedic drilling.
Źródło:
Acta of Bioengineering and Biomechanics; 2014, 16, 1; 107-116
1509-409X
2450-6303
Pojawia się w:
Acta of Bioengineering and Biomechanics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wyznaczenie lokalnych poziomów referencyjnych dla kończyny górnej i dolnej na podstawie operacji ortopedycznych u dzieci z użyciem ramienia C
Estimation amount of local reference dose levels upper and lower limb from intra-operative use theC-armX-ray system during orthopaedic surgical procedures among children
Autorzy:
Badziak, M.
Matera, K.
Grzelak, P.
Powiązania:
https://bibliotekanauki.pl/articles/112333.pdf
Data publikacji:
2018
Wydawca:
Indygo Zahir Media
Tematy:
dawka powierzchniowa
dawka skuteczna
fluoroskopia
operacje ortopedyczne
diagnostyczne poziomy referencyjne
DRL
dose area product
effective dose
fluoroscopy
orthopaedic surgery
Opis:
Uzasadnienie. Ważnym aspektem w ochronie radiologicznej jest zapewnienie bezpieczeństwa dzieciom w czasie operacji ortopedycznych z użyciem fluoroskopii. Ze względu na wysoką promieniowrażliwość dzieci, bardzo ważna jest kontrola dawek oraz zapewnienie im odpowiedniej ochrony radiologicznej. Cel. Celem tej pracy było oszacowanie dawki powierzchniowej oraz czasu ekspozycji z fluoroskopii wykonywanych w czasie operacji ortopedycznych dzieci oraz wyznaczenie lokalnych diagnostycznych poziomów referencyjnych na podstawie tych parametrów. Materiał i metody. W badaniu uwzględniono 501 pacjentów (mediana 11 lat), którzy przeszli operacje ortopedyczne z użyciem fluoroskopii. Pomiaru dawek dokonano w czasie zabiegów ortopedycznych celowanych na kończyny dolne i górne z użyciem mobilnego ramienia C (Ziehm-8000) pomiędzy marcem a sierpniem 2017 roku. Dawki zebrano na podstawie wskazań miernika kompatybilnego z aparatem. Wyniki. Średnia dawka powierzchniowa przypadająca na obszar kończyny górnej (73,65%) w badanej populacji wynosi 25,82 ± 58,10 cGycm2, dawka dla obszaru kończyn dolnych (26,35%) jest równa 91,07 ± 217,27 cGycm2. Lokalne poziomy referencyjne dawki w przedziałach wiekowych: 1-5, 5 ≥ 10 oraz 10 ≥ 15 i powyżej 15. roku życia wynoszą odpowiednio: 22,15, 24,76, 40,08, 55,04 cGycm2. Poziomy referencyjne czasów naświetlania w odniesieniu do podanej kolejności przedziałów są następujące: 60,75, 82,75, 124,50, 108,00 s. Wnioski. Wyniki pokazują, iż kończyny dolne otrzymują znacznie wyższe dawki niż kończyny górne w czasie operacji. Wynika to głównie z tego, że kończyny dolne mają większą objętość względem górnych. Otrzymane poziomy referencyjne układają się w tendencji wzrostowej zarówno dla DAP, jak i czasu ekspozycji. Wyjątkiem jest przedział wiekowy > 15 lat, gdzie DRL czasów ekspozycji jest niższy niż u młodszych dzieci. Podsumowanie. Na podstawie pomiaru rzeczywistych dawek powierzchniowych możliwe jest zdefiniowanie lokalnych poziomów referencyjnych. Ich określenie pozwala na kontrolowanie warunków ekspozycji w czasie operacji ortopedycznych. Ma to znaczenie zarówno dla ochrony radiologicznej pacjentów, jak i dla usystematyzowania pracy operatorów fluoroskopii, którzy mogą świadomie dobierać odpowiednie dla wieku pacjenta warunki ekspozycji.
Background. Radiological protection of the patient during fluoroscopy procedures is an important topic due to the wide scope of its use during orthopaedic surgery. Children are especially sensitive to radiation, thus it is important to control dose and ensure them special radiological protection. Objective. The aim of this study was to estimate DAP and exposure time from fluoroscopy during orthopaedic surgical procedures and to establish DRLs for these parameters. Material and methods. We involved 501 paediatric patients (median age 11) who went orthopaedic surgery with targeted fluoroscopy acquisition. The ionizing radiation was assayed using Dose Area Product Meter. This was done during orthopaedic procedures of lower and upper extremities with using mobile C-arm device (Ziehm-8000) performed between March 2017 and August 2017. Results. As the radiation dose depends on the size of the child, the children were assigned to four different age groups: 1-5, 5-10, 10-15 and > 15 years. The mean, median and third-quartile DAP and the exposure time were calculated for each group. The mean DAP for upper extremities (73.65%) was 25.82 58.10 cGcm2 and for lower extremities (26.35%) was 90.40 216.59 cGcm2. The third-quartile values were used to establish the DRLs. For this age selection the DRLs of the DAP were: 22.15, 24.76, 40.08, 55.04 cGcm2 respectively. The third-quartile the time of exposure for above mentioned age selection were as follows: 60.75, 82.75, 124.50, 108.00 s. Conclusions. The dose from fluoroscopy-guided orthopaedic surgery is higher for lower than upper extremities. It’s came from the size of a lower parts, which have larger volume than the upper parts. The DRLs of DAP and exposure time are collected with upward trend to arising age. Only the children group older than 15 years have DRLs of exposure time higher than the age group between 10-15 years. Discussion. Measurement of the dose area product in narrow group of patients allow to assessed dose reference levels. This procedure enable to control the fluoroscopy parameters during the orthopaedic surgeries. It is important both for the radiological protection of patients and to systematize the work of fluoroscopy operators, who can consciously choose age-appropriate patient exposure conditions.
Źródło:
Inżynier i Fizyk Medyczny; 2018, 7, 5; 323-327
2300-1410
Pojawia się w:
Inżynier i Fizyk Medyczny
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-6 z 6

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies