Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "OCT" wg kryterium: Temat


Tytuł:
Contemporary possibilities in the diagnostics of anterior and posterior eye diseases with the use of new-generation OCT
Współczesne możliwości w diagnostyce chorób przedniego i tylnego odcinka oka przy użyciu OCT nowej generacji
Autorzy:
Paczwa, Katarzyna
Mędrzycka, Justyna
Gołębiewska, Joanna
Różycki, Radosław
Powiązania:
https://bibliotekanauki.pl/articles/2040464.pdf
Data publikacji:
2021-06-21
Wydawca:
Medical Education
Tematy:
OCT
angio-OCT
Opis:
Optical coherence tomography is a non-contact imaging method of the anterior and posterior segments of the eye that is based on laser scanning in spectral domain. This study presents diagnostic possibilities of the new generation Solix FullRange™ OCT&OCTA apparatus (Optovue) to examine meibomian glands, cornea, anterior chamber, as well iridocorneal angles and lens. In the posterior segment of the eye it allows for the precise evaluation of the vitreous body, choroid, retina, optic nerve and blood-flow measurements.
Optyczna koherentna tomografia jest bezkontaktową metodą obrazowania przedniego i tylnego odcinka oka opartą na skaningu laserowym w domenie spektralnej. W niniejszej pracy przedstawiono możliwości diagnostyczne aparatu najnowszej generacji Solix FullRange™ OCT&OCTA (Optovue). Dzięki jego zastosowaniu jest możliwa ocena gruczołów Meiboma, rogówki, kątów przesączania, komory przedniej, a także soczewki. W obrazowaniu tylnego odcinka oka aparat umożliwia dokładne obrazowanie ciała szklistego, siatkówki, naczyniówki oraz nerwu wzrokowego, a także pomiary przepływu naczyniowego.
Źródło:
OphthaTherapy; 2021, 8, 2; 81-86
2353-7175
2543-9987
Pojawia się w:
OphthaTherapy
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Optyczna koherentna tomografia OCT - nowe narzędzie do działań konserwatorskich i inwentaryzacyjnych
Optical coherence tomography OCT - a novel tool for art conservation and cataloguing
Autorzy:
Targowski, P.
Rouba, B.J.
Karaszkiewicz, P.
Iwanicka, M.
Tymińska-Widmer, L.
Łękawa-Wysłouch, T.
Kwiatkowska, E.A.
Sylwestrzak, M.
Powiązania:
https://bibliotekanauki.pl/articles/217772.pdf
Data publikacji:
2009
Wydawca:
Stowarzyszenie Konserwatorów Zabytków
Tematy:
tomografia OCT
konserwacja
inwentaryzacja
OCT tomography
cataloguing
conservation
Opis:
Przedstawione zostaną przykłady obrazowania stratygrafii obrazów olejnych, w tym również w zastosowaniu do oceny autentyczności inskrypcji lub sygnatur. Poza tym omówione zostanie wykorzystanie OCT jako narzędzia wspomagającego stratygrafię LIBS, jak również do oceny zakresu korozji hydrologicznej szkła witrażowego oraz do monitorowania reakcji obiektu (obrazu) na zmianę warunków klimatycznych w jego otoczeniu.
An application of OCT - a noninvasive diagnostic tool for examination of objects of art is discussed on the examples taken from research conducted at Nicolaus Copernicus University in Toruń, Poland. The following subjects have been discussed: stratigraphy of oil paintings on canvas, its specific application to analysis of order and authenticity of inscriptions on paintings, 'absolute' LIBS stratigraphy - OCT aided, application of OCT for examination of corrosion of stained glass, and monitoring of environmental induced deformations of canvas supports.
Źródło:
Wiadomości Konserwatorskie; 2009, 26; 94-107
0860-2395
2544-8870
Pojawia się w:
Wiadomości Konserwatorskie
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Shall intraoperative OCT become standard equipment of modern operating room?
Autorzy:
Kaczmarek, Dorota Maria
Kaczmarek, Radosław
Powiązania:
https://bibliotekanauki.pl/articles/23202392.pdf
Data publikacji:
2023-09-30
Wydawca:
Medical Education
Tematy:
intraoperative OCT
retinal surgery
corneal surgery
vitrectomy
keratoplasty
Opis:
The role of intraoperative OCT (iOCT) in ophthalmic surgery is still a matter of active research and enhancements to integrative technologies. Further research is necessary to better define the specific applications of iOCT that impact surgical decision-making and as such help to achieve better patient outcomes, both in anterior and in posterior segment of the eye. In time to come advancements in integrative systems, OCT-friendly instrumentation, and software algorithms will most likely expand the horizon of iOCT even further.
Źródło:
OphthaTherapy; 2023, 10, 3; 173-177
2353-7175
2543-9987
Pojawia się w:
OphthaTherapy
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Denoising methods for improving automatic segmentation in OCT images of human eye
Autorzy:
Stankiewicz, A.
Marciniak, T.
Dąbrowski, A.
Stopa, M.
Rakowicz, P.
Marciniak, E.
Powiązania:
https://bibliotekanauki.pl/articles/201133.pdf
Data publikacji:
2017
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
optical coherence tomography (OCT)
image denoising
image segmentation
anisotropic diffusion
wavelet thresholding
koherentna tomografia optyczna
OCT
segmentacja obrazu
dyfuzja anizotropowa
Opis:
This paper presents analysis of selected noise reduction methods used in optical coherence tomography (OCT) retina images (the socalled B-scans). The tested algorithms include median and averaging filtering, anisotropic diffusion, soft wavelet thresholding, and multiframe wavelet thresholding. Precision of the denoising process was evaluated based on the results of automated retina layers segmentation, since this stage (vital for ophthalmic diagnosis) is strongly dependent on the image quality. Experiments were conducted with a set of 3D low quality scans obtained from 10 healthy patients and 10 patients with vitreoretinal pathologies. Influence of each method on the automatic image segmentation for both groups of patients is thoroughly described. Manual annotations of investigated retina layers provided by ophthalmology experts served as reference data for evaluation of the segmentation algorithm.
Źródło:
Bulletin of the Polish Academy of Sciences. Technical Sciences; 2017, 65, 1; 71-78
0239-7528
Pojawia się w:
Bulletin of the Polish Academy of Sciences. Technical Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Zastosowanie angio-OCT w diagnostyce i terapii okulistycznej – część I
Angio-OCT in ophthalmological diagnostics and therapy – part I
Autorzy:
Gołębiewska, Joanna
Hautz, Wojciech
Powiązania:
https://bibliotekanauki.pl/articles/1928255.pdf
Data publikacji:
2016
Wydawca:
Medical Education
Tematy:
angio-OCT
choroby naczyniowe
mikrokrążenie siatkówkowe
optyczna koherentna tomografia
Opis:
Angiografia oparta na optycznej koherentnej tomografii (angio-OCT) jest nową, nieinwazyjną metodą obrazowania, umożliwiającą jednoczesną ocenę struktury siatkówki i stanu mikrokrążenia. Metoda ta znalazła zastosowanie w diagnostyce i monitorowaniu chorych ze zwyrodnieniem plamki związanym z wiekiem oraz pacjentów z chorobami naczyniowymi siatkówki, pozwalając na wczesne wykrywanie zmian w obrębie naczyń. Angio-OCT umożliwia ocenę przepływu krwi przez tarczę nerwu wzrokowego i kapilary okołotarczowe, w związku z czym może być użytecznym narzędziem w diagnostyce i monitorowaniu pacjentów z jaskrą.
Optical coherence tomography angiography (angio-OCT) is a new, noninvasive method capable of simultaneously imaging the retinal structure and microvasculature. Angio-OCT is an important tool for diagnostics and for monitoring patients with age-related macular degeneration and different vascular disorders of the retina. It makes it possible to identify early vascular changes and non-perfusion areas. Angio-OCT reveals disturbances in nerve head perfusion and can be a useful technique for diagnosing patients with glaucoma.
Źródło:
OphthaTherapy; 2016, 3, 3; 161-171
2353-7175
2543-9987
Pojawia się w:
OphthaTherapy
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Zastosowanie angio-OCT w diagnostyce i terapii okulistycznej – część II
Angio-OCT in ophthalmological diagnostics and therapy – part II
Autorzy:
Gołębiewska, Joanna
Hautz, Wojciech
Powiązania:
https://bibliotekanauki.pl/articles/1929141.pdf
Data publikacji:
2016
Wydawca:
Medical Education
Tematy:
angio-OCT
choroby naczyniowe
mikrokrążenie siatkówkowe
optyczna koherentna tomografia
Opis:
Angiografia oparta na optycznej koherentnej tomografii (angio-OCT) jest nową, nieinwazyjną metodą obrazowania, umożliwiającą jednoczesną ocenę struktury siatkówki i stanu mikrokrążenia. Metoda ta znalazła zastosowanie w diagnostyce i monitorowaniu chorych ze zwyrodnieniem plamki związanym z wiekiem oraz pacjentów z chorobami naczyniowymi siatkówki, pozwalając na wczesne wykrywanie zmian w obrębie naczyń. Angio-OCT umożliwia ocenę przepływu krwi przez tarczę nerwu wzrokowego i kapilary okołotarczowe, w związku z czym może być użytecznym narzędziem w diagnostyce i monitorowaniu pacjentów z jaskrą.
Optical coherence tomography angiography (angio-OCT) is a new, noninvasive method capable of simultaneously imaging the retinal structure and microvasculature. Angio-OCT is an important tool for diagnostics and for monitoring patients with age-related macular degeneration and different vascular disorders of the retina. It makes it possible to identify early vascular changes and non-perfusion areas. Angio-OCT reveals disturbances in nerve head perfusion and can be a useful technique for diagnosing patients with glaucoma.
Źródło:
OphthaTherapy; 2016, 3, 4; 254-259
2353-7175
2543-9987
Pojawia się w:
OphthaTherapy
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Examination of Sol-Gel Derived Hydroxyapatite Enhanced with Silver Nanoparticles using OCT and Raman Spectroscopy
Autorzy:
Głowacki, M. J.
Gnyba, M.
Strąkowska, P.
Gardas, M.
Kraszewski, M.
Trojanowski, M.
Strąkowski, M. R.
Powiązania:
https://bibliotekanauki.pl/articles/221475.pdf
Data publikacji:
2017
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
hydroxyapatite
sol-gel
nanoparticles
Raman spectroscopy
optical coherence tomography (OCT)
Opis:
Hydroxyapatite (HAp) has been attracting widespread interest in medical applications. In a form of coating, it enables to create a durable bond between an implant and surrounding bone tissues. With addition of silver nanoparticles HAp should also provide antibacterial activity. The aim of this research was to evaluate the composition of hydroxyapatite with silver nanoparticles in a non-destructive and non-contact way. For control measurements of HAp molecular composition and solvent evaporation efficiency the Raman spectroscopy has been chosen. In order to evaluate dispersion and concentration of the silver nanoparticles inside the hydroxyapatite matrix, the optical coherence tomography (OCT) has been used. Five samples were developed and examined ‒ a reference sample of pure HAp sol and four samples of HAp colloids with different silver nanoparticle solution volume ratios. The Raman spectra for each solution have been obtained and analyzed. Furthermore, a transverse-sectional visualization of every sample has been created and examined by means of OCT.
Źródło:
Metrology and Measurement Systems; 2017, 24, 1; 153-160
0860-8229
Pojawia się w:
Metrology and Measurement Systems
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Obecne techniki biometrii oka
Current technologies of ocular biometry
Autorzy:
Turczynowska, Magdalena
Koźlik-Nowakowska, Katarzyna
Gaca-Wysocka, Magdalena
Grzybowski, Andrzej
Powiązania:
https://bibliotekanauki.pl/articles/1928252.pdf
Data publikacji:
2016
Wydawca:
Medical Education
Tematy:
OLCR
PCI
SS-OCT
biometria oka
biometria optyczna
biometry optyczne
Opis:
Operacja zaćmy jest obecnie najczęściej wykonywaną procedurą chirurgiczną w krajach rozwiniętych. Coraz częściej traktowana jest również jako zabieg refrakcyjny, a zastosowanie soczewek z grupy premium (asferycznych, torycznych, wieloogniskowych) pozwala pacjentowi na uniezależnienie się od korekcji okularowej i uzyskanie dobrej jakości widzenia do wszystkich odległości, nawet jeśli przed zabiegiem występowały starczowzroczność czy astygmatyzm. Wraz z poprawą standardów leczenia operacyjnego zwiększają się również oczekiwania pacjentów. Kluczowe jest uzyskanie jak najlepszej refrakcji pooperacyjnej. W tym celu przed operacją należy dokonać precyzyjnych pomiarów biometrycznych gałki ocznej i wybrać optymalną formułę obliczeniową do kalkulacji mocy wszczepianej soczewki. Celem pracy jest przedstawienie aktualnych metod przeprowadzania badań biometrycznych i najnowszych dostępnych w Polsce aparatów służących do biometrii oraz porównanie ich funkcji. Dokładne zrozumienie zalet i ograniczeń dostępnej na rynku aparatury oraz poznanie podstawowych zasad kalkulacji mocy wszczepianych soczewek pozwoli usprawnić procedury przeprowadzania badań i osiągać optymalne wartości refrakcji pooperacyjnej.
Cataract surgery is currently the most frequently performed surgical procedure in developed countries. In some cases it is also regarded as refractive procedure, and the use of premium intraocular lenses (aspheric, toric, multifocal) allows the patient to become spectacle independent. The improvement of surgical treatment results in rising expectations of patients. The key issue is to achieve the desired refractive outcome. Essential for this purpose are precise measurements of the eye, and selection of the optimal IOL calculation formula. The aim of this paper is to present current techniques of ocular biometry and new biometry devices available in Poland, along with a comparison of their functions. Good understanding the advantages and limitations of the current technology allows to perform measurements efficiently and to achieve highly accurate refractive outcomes.
Źródło:
OphthaTherapy; 2016, 3, 2; 132-138
2353-7175
2543-9987
Pojawia się w:
OphthaTherapy
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Optical Fourier Domain Interferometry as a novel tool for biological imaging
Autorzy:
Rumiński, D.
Kowalczyk, A.
Wojtkowski, M.
Powiązania:
https://bibliotekanauki.pl/articles/1396523.pdf
Data publikacji:
2011
Wydawca:
Fundacja na Rzecz Młodych Naukowców
Tematy:
OFDI
swept source
OCT
medical imaging
eye imaging
Michelson interferometer
interferometry
Opis:
Purpose of this work is to introduce results of biological objects measurements with Optical Coherence Tomography system working with swept source laser (OFDI system). This specified source with spectrum centred around 1040 nm is dedicated to measure posterior segment of the eye. OCT with this wavelength is expected to be next generation for this sort of systems. Although commonly used 800 nm source enables imaging retina, deeper tissue layers are not available with this wavelength. Longer wavelengths in range of infrared spectrum (e.g. 1040 nm) are being weakly scattered which enables to go down to the choroid layer [1]. Examination this structure composed mostly from blood vessels might be very important for early diagnosis of eye diseases. In this paper system setup, swept source scheme and eye images would be introduced.
Źródło:
Challenges of Modern Technology; 2011, 2, 1; 16-18
2082-2863
2353-4419
Pojawia się w:
Challenges of Modern Technology
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Current classification of macular neovascularization in the course of AMD based on the Consensus Nomenclature for Reporting Neovascular Age-Related Macular Degeneration Data
Aktualna klasyfikacja neowaskularyzacji w plamce w przebiegu AMD w oparciu o Consensus Nomenclature for Reporting Neovascular Age-Related Macular Degeneration Data
Autorzy:
Piotrowicz, Anna
Paczwa, Katarzyna
Gołębiewska, Joanna
Różycki, Radosław
Powiązania:
https://bibliotekanauki.pl/articles/1928001.pdf
Data publikacji:
2021
Wydawca:
Medical Education
Tematy:
age-related macular degeneration
angio-OCT
classification of macular neovascularization
neovascular membrane
Opis:
Despite the improvement of diagnostic and therapeutic techniques age-related macular degeneration is still one of the main causes of central vision impairment. Throughout the years, the classification of subretinal neovascularization in the course of age-related macular degeneration has changed due to the advancement of diagnostic and therapeutic techniques. In 2020 an expert panel reached consensus on a new nomenclature for neovascularization in the course of age-related macular degeneration introducing the concept of macular neovascularization, which refers to each neovascularization in macula, regardless of the location.
Zwyrodnienie plamki związane z wiekiem (AMD, age-related macular degeneration), mimo postępu w diagnostyce i leczeniu tej choroby, stanowi jedną z najczęstszych przyczyn utraty widzenia centralnego. Na przestrzeni lat klasyfikacja neowaskularyzacji podsiatkówkowej w przebiegu AMD zmieniała się wraz z rozwojem technik diagnostycznych i terapeutycznych. W 2020 r. panel ekspertów opracował konsensus dotyczący nowego nazewnictwa neowaskularyzacji w przebiegu AMD, wprowadzając pojęcie neowaskularyzacji plamkowej, które dotyczy każdej neowaskularyzacji w plamce, niezależnie od jej lokalizacji.
Źródło:
OphthaTherapy; 2021, 8, 1; 5-10
2353-7175
2543-9987
Pojawia się w:
OphthaTherapy
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Improving Segmentation of 3D Retina Layers Based on Graph Theory Approach for Low Quality OCT Images
Autorzy:
Stankiewicz, A.
Marciniak, T.
Dąbrowski, A.
Stopa, M.
Rakowicz, P.
Marciniak, E.
Powiązania:
https://bibliotekanauki.pl/articles/221548.pdf
Data publikacji:
2016
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
Optical Coherence Tomography (OCT)
segmentation of retinal layers
image segmentation
graph theory
Opis:
This paper presents signal processing aspects for automatic segmentation of retinal layers of the human eye. The paper draws attention to the problems that occur during the computer image processing of images obtained with the use of the Spectral Domain Optical Coherence Tomography (SD OCT). Accuracy of the retinal layer segmentation for a set of typical 3D scans with a rather low quality was shown. Some possible ways to improve quality of the final results are pointed out. The experimental studies were performed using the so-called B-scans obtained with the OCT Copernicus HR device.
Źródło:
Metrology and Measurement Systems; 2016, 23, 2; 269-280
0860-8229
Pojawia się w:
Metrology and Measurement Systems
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Common path optical coherence tomography with electronic feedback for improved sensitivity
Autorzy:
Alsnaie, Khalid
Powiązania:
https://bibliotekanauki.pl/articles/27310102.pdf
Data publikacji:
2023
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
optical coherence tomography
frequency domain
OCT
medical imaging
partially coherent interferometers
B-scan
Opis:
Optical coherence tomography (OCT) imaging has become a useful tool in medical diagnosis over the past 25 years, because of its ability to visualize intracellular structures at high resolution. The main objective of this work is to add electronic feedback to the optical coherence tomography setup to increase its sensitivity. Noise added to the measured interferogram obscures some details of examined tissue layered structure. Adjusting signal power level in such a way to improve signal-to-noise ratio can help to enhance image quality. Electronic feedback is added to enhance system sensitivity. A logarithmic amplifier is included in the OCT setup to automatically adapt signal level. Moreover, the resolution of the optical spectrum analyzer is controlled according to the farthest layer detected in the A-scan. These techniques are tested showing an improvement in obtained image of a human nail.
Źródło:
Optica Applicata; 2023, 53, 3; 495--504
0078-5466
1899-7015
Pojawia się w:
Optica Applicata
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Synergistic mechanism of dodecylamine/octanol mixtures enhancing lepidolite flotation from the self-aggregation behaviors at the air/liquid interface
Autorzy:
Bai, Yang
Xu, Mengxu
Wen, Weixiang
Zhu, Shifei
Mo, Weichen
Yan, Pingke
Powiązania:
https://bibliotekanauki.pl/articles/27323641.pdf
Data publikacji:
2023
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
DDA/OCT mixtures
self-aggregation behaviors
flotation foam
molecular dynamics simulations
surface tension
air interface
liquid interface
Opis:
Surface tension measurements and molecular dynamics (MD) simulations were used to explore the flotation foam properties and self-aggregation behaviors of dodecylamine (DDA)/octanol (OCT) mixtures formed with different mole ratios at the air/liquid interface. Based on the surface and thermodynamic parameters, the DDA/OCT mixtures exhibited greater interfacial activities and adsorption capacities than their individual components. The MD simulations showed that DDA and OCT were aggregated through hydrogen bonding, coulombic forces and hydrophobic association. OCT was inserted into the DDA adsorption layer, causing the alkyl chains of both DDA and OCT to extend from water to air at varying heights and angles. The addition of OCT improved the hydration of the amino groups and reduced the overall number of hydrogen bonds. The stability of the flotation foam decreased, and the high viscosity and difficult defoaming of the DDA flotation foam were significantly improved. When the DDA/OCT mole ratio was 2:1, the included angle formed between the alkyl chains and the interface was maximized, leading to enhanced compatibility among the alkyl chains, and the hydrogen bond energy was relatively large, which showed a strong synergistic effect. The MD simulation findings were consistent with the results obtained from the lepidolite flotation and surface tension experiments conducted in this study; our results could provide a theoretical foundation for the selection of superior mixed collectors and frothers.
Źródło:
Physicochemical Problems of Mineral Processing; 2023, 59, 6; art. no. 176510
1643-1049
2084-4735
Pojawia się w:
Physicochemical Problems of Mineral Processing
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Szkiełko czy oko? Nauki ścisłe w badaniach nad rękopisami (manuSciences ’15)
Exact sciences in manuscript research (manuSciences ’15)
Autorzy:
Pludra-Żuk, Paulina
Powiązania:
https://bibliotekanauki.pl/articles/471918.pdf
Data publikacji:
2015
Wydawca:
Uniwersytet Warszawski. Wydział Dziennikarstwa, Informacji i Bibliologii
Tematy:
humanistyka cyfrowa
kodykologia
paleografia
badania materiałowe
spektroskopia
OCT
RTI
obrazowanie multispektralne
IT
digital humanities
codicology
palaeography
spectroscopy
hyperspectral imaging
Opis:
Artykuł zawiera podsumowanie szkoły letniej, zatytułowanej „manuSciences ’15. Manuscripts: From Fragments to Books – From Identification to Interpretation” (6–12 września 2015, Fraueninsel), zorganizowanej przez Freie Universitat Berlin i Ecole Pratique des Hautes Etudes. Założeniem omawianych warsztatów było stworzenie warunków dla wymiany doświadczeń pomiędzy badaczami zajmującymi się analizą źródeł, a specjalistami reprezentującymi nauki ścisłe, starającymi się stworzyć wsparcie techniczne dla tego typu badań. W artykule opisano wybrane narzędzia, wywodzące się z nauk ścisłych, które mogą znaleźć zastosowanie w badaniach źródłoznawczych, umożliwiając m.in. wydobycie dodatkowych informacji na temat średniowiecznego warsztatu (jak rożnego typu badania materiałowe), bezinwazyjne dotarcie do tekstów trudno dostępnych lub nieczytelnych (Reflectance Transformation Imaging, obrazowanie multispektralne, XRF), czy częściowe zautomatyzowanie procesu odczytywania i analizy tekstu źródłowego.
The article contains an extended report from the summer school “manuSciences’15. Manuscripts: From Fragments to Books – From Identifi cation to Interpretation” organised by the Freie Universitat Berlin and Ecole Pratique des Hautes Etudes, and held at Fraueninsel in Bavaria, on 6–12 September, 2015. The main aim of the gathering was to provide an opportunity for exchange of ideas and knowledge between researchers working on historical written sources, who belong to the fi eld of the humanities, and specialists, who represent exact sciences, and who are capable of furnishing new technical potential for manuscript research. P. Pludra-Żuk, herself a representative of the humanities, describes the new technical tools, which can be utilised in primary source research, and which allow for the acquisition of hitherto undisclosed information concerning the medieval scribal workshop (numerous types of materials research), non-invasive methods of reaching text fragments diffi cult to get to, or unreadable (Refl ectance Transformation Imaging, hyperspectral imaging, XRF), or partial automation of the reading and analytic process.
Źródło:
Z Badań nad Książką i Księgozbiorami Historycznymi; 2015, 9; 299-312
1897-0788
2544-8730
Pojawia się w:
Z Badań nad Książką i Księgozbiorami Historycznymi
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Insider understanding of country development: a novel application of Optimal Control Theory and Data Envelopment Analysis for benchmarking performance of Chilean and Brazilian companies
Autorzy:
Alves Junior, Paulo Nocera
Yushimito, Wilfredo F.
Gude, Jorge Pereira
Melo, Isotilia Costa
Rebelatto, Daisy Aparecida do Nascimento
Powiązania:
https://bibliotekanauki.pl/articles/14430662.pdf
Data publikacji:
2019-03-27
Wydawca:
Wyższa Szkoła Bankowa we Wrocławiu
Tematy:
Data Envelopment Analysis (DEA)
Optimal Control Theory (OCT)
Dynamic Efficiency
Developing Countries
Inventory Control
Production-Inventory System
Benchmarking
Best Practices.
Opis:
Aim: If companies manage their inventory inefficiently, inventory costs can increase significantly due to shortages, overstocking, and risks. Inventory management is critical for company’s success which, in turn, impacts on countries’ development. This paper aims to investigate the efficiency of inventory control systems of companies from Brazil and Chile through Optimal Control Theory and Data Envelopment Analysis. Design/Research methods: Data was collected from Chilean and Brazilian companies covering different industries in which both countries are mostly dependent A new approach using OCT and DEA is applied for dealing with inventory, production, and demand in Dynamic DEA model to benchmark companies’ production-inventory systems. Conclusions/findings: The results show efficient companies among evaluated industries. Such companies are related mainly to Brazilian commerce and Chilean exports. Based on findings, it was possible to identify patterns and relationship among companies and its inventory management. Originality/value of the article: This paper fills a gap in studies including demand, production, and inventory in Dynamic DEA by using OCT to forewarn unrealistic results and observing companies’ behavior. Besides that, this approach is particularly useful for developing countries in this context, determining benchmarks for the most inefficient firms in each sector. Implications of the research: The results show (1) which companies should focus more on improving inventory management, (2) which companies should be used as benchmarks, and (3) it highlights the reasons of different performance of companies in each country. Limitations of the research: For future research, it is suggested including variables and analysis of social and environmental impacts.
Źródło:
Central European Review of Economics and Management; 2019, 3, 1; 47-93
2543-9472
Pojawia się w:
Central European Review of Economics and Management
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies