Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "Nitrogen Oxides Emissions" wg kryterium: Temat


Tytuł:
Technologies for the Reduction of Nitrogen Oxides Emissions
Autorzy:
Arsenie, P.
Martinas, G.
Gheorghe, C.
Arsenie, A.
Powiązania:
https://bibliotekanauki.pl/articles/117532.pdf
Data publikacji:
2015
Wydawca:
Uniwersytet Morski w Gdyni. Wydział Nawigacyjny
Tematy:
Nitrogen Oxides
Nitrogen Oxides Emissions
Reduction of Nitrogen Oxides Emissions
Environment Protection
ecology
Pollution at Sea
Primary Combustion Zone
MARPOL
Opis:
When it comes to gas turbines, their main problem concerning pollutant emissions is represented by nitric oxides. Among other emissions, sulphur oxides being much reduced due to the use of liquid distilled and gas fuels with a low content of sulphur. Using water or steam injection became the favourite method during the '80s and especially the '90s since "dry" methods and catalytic reduction were both at the beginning of the development phase. Catalytic convertors have been used since the '80s and they are still used although the costs of renewing the catalyst are very high. In the last twenty years a gradual decrease has been registered on the limits of nitric oxides from 75 ppm to 25 ppm, and now the target is oriented towards the 9 ppm level. The evolution of burning technologies of combustion makes it possible to control the level of production of nitric oxides even from the source without being necessary to use "humid" methods. This, of course, opened the market for gas turbines because they can function even in areas with limited quality water reserves, such as maritime platforms and in the desert. In this paper, we are going to show that, although water injection is still used, "dry" control technologies of burning became favourite methods for the majority of users on the industrial power generators market. The great dependency between the creation of nitric oxides and the temperature reveals the effect of direct water or steam injection on reducing nitric oxides. Recent research showed that a reduction up to 85% of nitric oxides may be obtained by using the water or steam injection all together with the improvement of aerodynamic character of the burning room.
Źródło:
TransNav : International Journal on Marine Navigation and Safety of Sea Transportation; 2015, 9, 2; 251-256
2083-6473
2083-6481
Pojawia się w:
TransNav : International Journal on Marine Navigation and Safety of Sea Transportation
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Potential non-toxic aqueous emulsion as a diesel fuel
Autorzy:
Haller, P.
Jankowski, A.
Kolanek, C.
Walkowiak, W.
Powiązania:
https://bibliotekanauki.pl/articles/244342.pdf
Data publikacji:
2015
Wydawca:
Instytut Techniczny Wojsk Lotniczych
Tematy:
emulsions
water
diesel engine
nitrogen oxides
emissions
Opis:
Natural processes occurring on Earth (fires, volcanic eruptions) and human activity in the area of acquisition and processing of energy, is the cause of the continuous contaminating the atmosphere of combustion products. The combustion of fuels is and will be in the near future primary means of generating energy, including for transportation purposes. Transport is the cause of many environmental threats - emits dust and particles along with many of gaseous harmful substances and also noise and vibration. Power sources used for transport are almost exclusively equipped with internal combustion engines, among which is dominated by a diesel engines. In view of the known advantages of these motors such as high efficiency and relatively low emissions of toxic compounds in the exhaust gas, they have been accepted as the most preferred source of power motor vehicles in the coming decades, assuming that meet the requirements of future regulations regarding environmental protection. The problem to be solved in internal combustion engines is the emission of nitrogen oxides. In this paper are contained an overview of proven methods and results in the reduction of nitrogen oxides in exhaust gases by means of emulsion fuels, and forming an opinion concerning of the usefulness of such solutions in the future.
Źródło:
Journal of KONES; 2015, 22, 3; 43-48
1231-4005
2354-0133
Pojawia się w:
Journal of KONES
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Zastosowanie przemysłowe technologii reburningu
Industrial application of reburning technology
Autorzy:
Majewski, K.
Powiązania:
https://bibliotekanauki.pl/articles/109250.pdf
Data publikacji:
2013
Wydawca:
AXIS MEDIA
Tematy:
technologia reburningu
emisja tlenków azotu
proces spalania
Stany Zjednoczone
Japonia
zanieczyszczenie atmosfery
reburning technology
emissions of nitrogen oxides
combustion process
United States
Japan
atmospheric pollution
Opis:
W artykule przedstawiono ideę, wdrożenie do praktyki przemysłowej, rozwój oraz nowe możliwe kierunki zastosowania technologii reburningu - jednej z pierwotnych metod ograniczenia emisji tlenków azotu, powstających w procesach spalania. Z powodu dominującej roli Stanów Zjednoczonych i Japonii w badaniach, rozwoju i udoskonalaniu technologii reburningu,skoncentrowano się na doświadczeniach tych krajów. Wzmiankowano również o spadkowym trendzie poziomu zanieczyszczenia atmosfery tlenkami azotu, wynikającej z postępu technicznego i stymulującej roli zaostrzania przepisów prawnych w tym zakresie.
This article contains the idea, implementation into practical use, development and new possible fields of applying of reburning technology - one of primary control technologies of reduction in emissions of nitrogen oxides from combustion processes. Because of dominate role of US and Japan into technical research, development and improvement of reburnig technology main focus is putting on experiences of above countries. There is also mentioned of NO emissions decline trend as a result of technological progress and stimulating role of more srticted regulations.
Źródło:
Piece Przemysłowe & Kotły; 2013, 9-10; 13-18
2082-9833
Pojawia się w:
Piece Przemysłowe & Kotły
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wtrysk balastu wodnego jako metoda zmniejszenia emisji tlenków azotu
Injection of Water Ballast as a Method to Reduce Nitrogen Oxide Emissions
Autorzy:
Szkarowski, A.
Janta-Lipińska, S.
Orłowska, M.
Mamedov, S.
Powiązania:
https://bibliotekanauki.pl/articles/1813913.pdf
Data publikacji:
2017
Wydawca:
Politechnika Koszalińska. Wydawnictwo Uczelniane
Tematy:
emisja
wtrysk wilgoci
kocioł
tlenki azotu
emissions
injection of humidity
boiler
nitrogen oxides
Opis:
Metoda wtrysku balastu wodnego jest jednym z najbardziej perspektywistycznych rozwiązań naukowo-technicznych. Skierowana jest ona przede wszystkim na zmniejszenie zanieczyszczeń atmosfery szkodliwymi produktami spalania paliwa organicznego. Przeprowadzona analiza pokazuje, że metoda wtrysku charakteryzuje się unikalnymi energo-ekologicznymi i techniczno-ekonomicznymi wskaźnikami spośród innych technologii ochrony atmosfery. Przesłanką do uzasadnienia tej metody jest zjawisko niejednorodności płomienia wzdłuż paleniska zarówno ze względu na jego skład jak i temperaturę. Przy czym różne strefy płomienia w różnym stopniu „odpowiedzialne” są za powstawanie poszczególnych składników. Temperaturowe warunki i koncentracje komponentów reakcji chemicznych w tych strefach wyznaczają intensywność generacji tlenków azotu (NOx) i ich końcowe stężenie w spalinach. Wtrysk wilgoci do dokładnie określonych stref płomienia obniża ich temperaturę będącą głównym czynnikiem przyśpieszającym generację NOx. Ponadto metoda ta pozwala zapewnić zupełne spalanie przy obniżonym stężeniu wolnego tlenu, co również przyczynia się do zdławienia powstawania tlenków azotu. Opracowanie wykonane zostało dla dwóch kotłów PTVM-50 z palnikami DKZ (rys. 1) zainstalowanych w Drugiej Krasnogwadiejskiej kotłowni w Sankt-Petersburgu. Wstępne obliczenia wykazały, że metoda ta zapewnić może zmniejszenie emisji NOx o 25 do 30% przy wtryskiwaniu balastu w ilości do 1% ekwiwalentnej wydajności parowej kotła. Z kolei zmniejszenie nadmiaru powietrza i towarzyszące temu obniżenie strat ciepła spalinowych powinno pozwolić na zwiększenie sprawności kotła brutto o około 1%. Powyższe założenia zrealizowane zostały w trakcie badań. Ponadto opracowana została optymalna konstrukcja głowicy do wtryskiwania wilgoci, która nakręcana była w miejscu głowicy rozpylającej mazut (rys. 3). Wykorzystanie takiego rozwiązania pozwoliło na pomiary emisji NOx w spalinach, które zaprezentowane zostały w pracy (rys. 4 i rys. 5). W trakcie przeprowadzonej analizy uwzględniane zostały trzy poziomy ewentualnego wpływu emisji ze spalinami kotłów na zanieczyszczenie atmosfery.
The water ballast injection method is one of the most prospective scientific and technical solutions. Its chief purpose is to reduce the pollution of air with harmful products of organic fuel combustion. The analysis conducted demonstrates that the injection method is characterized by unique energy efficiency and environmental friendly indices as compared to other air quality protection methods. The phenomenon of the heterogeneity of the flame along the furnace considering both its composition and temperature constitutes the grounds of this method. Various flame areas are “responsible” to a different extent for the occurrence of individual components. The temperature conditions and the concentrations of the components of chemical reactions in these areas determine the intensity of the generation of nitrogen oxides (NOx) and their final concentration in fumes. An injection of humidity into accurately specified flame areas lowers their temperature, which constitutes the main factor that accelerates the generation of NOx. Furthermore, this method guarantees complete combustion with a reduced concentration of free oxygen, which also contributes to a suppressed occurrence of nitrogen oxides. The present study was performed for two PTVM-50 boilers with DKZ burners (Fig. 1) that are installed in the Second Krasnogwadiejski Boiler Plant in Sankt-Petersburg. Preliminary calculations demonstrated that this method may guarantee a reduction of NOx emissions by 30 per cent with a balance injection in a quantity up to 1 per cent of the equivalent steam boiler performance. A reduction of excess air and the accompanying reduction of fume heat loss should permit an increased gross boiler efficiency by ca. 1 per cent. The aforementioned assumptions were realized during the studies. Furthermore, an optimal design was developed of a head for humidity injection, which was installed in the place of a head that sprays mazut (Fig. 3). The use of this solution permitted measurements of NOx emission in fumes, which are presented in the study (Fig. 4 and Fig. 5). In the analysis conducted, three levels were taken into account of the possible impact of the emissions of fumes from boiler on air pollution.
Źródło:
Rocznik Ochrona Środowiska; 2017, Tom 19; 497-510
1506-218X
Pojawia się w:
Rocznik Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Obniżenie emisji tlenków azotu z kotłów DKVR
Reducing Emissions of Nitrogen Oxides from DKVR Boilers
Autorzy:
Szkarowski, A.
Janta-Lipińska, S.
Gawin, R.
Powiązania:
https://bibliotekanauki.pl/articles/1813933.pdf
Data publikacji:
2016
Wydawca:
Politechnika Koszalińska. Wydawnictwo Uczelniane
Tematy:
obniżenie emisji
tlenki azotu
kotły parowe
reduction in emissions
nitrogen oxides
steam boilers
Opis:
Standardowe bilansowe próby kotła pokazują, że maksymalną jego sprawność notuje się przy zauważalnej niezupełności spalania. Tlenki azotu, które powstają w maksymalnej temperaturze, czyli przy braku chemicznej niezupełności spalania są substancjami o wiele bardziej toksycznymi niż np. tlenek węgla. Z tego też powodu zespół autorów podjął się opracowania i wdrożenia środków mających na celu obniżenie emisji toksycznych tlenków azotu dla atmosfery na przykładzie kotła DKVR-20-13 z trzema palnikami gazowo-mazutowymi GMGB-5,6. Skomplikowany charakter tego zagadnienia powoduje konieczność jego indywidualnego rozwiązania w każdym konkretnym przypadku nastawiania kotła z uwzględnieniem charakterystyk i szczegółów wszystkich składowych urządzeń całego zespołu kotłowo-paleniskowego. Zasadniczym problemem, na który natknął się zespół autorów już w trakcie prowadzenia prac badawczych okazała się kwestia poziomu odniesienia względem, którego określane powinno być obniżenie emisji. Autorzy podjęli w związku z tym decyzję, żeby za taki poziom odniesienia przyjmować faktyczną maksymalną emisję, weryfikując ją uprzednio z maksymalną dopuszczalną emisją tlenków azotu dla omawianych typów urządzeń. W swojej pracy autorzy przedstawili i przeanalizowali szereg wariantów służących zmniejszeniu emisji tlenków azotu do atmosfery. Wśród analizowanych sposobów znalazła się m.in. recyrkulacja spalin, wtrysk pary wodnej oraz inwentaryzacja kotłowni. Wstępna analiza teoretyczna a także doświadczenie zespołu badawczego pozwoliło polecić jako efektywną metodę zmniejszenia emisji tlenków azotu dla kotłów DKVR pracujących w trybie przemysłowo-grzewczym: metodę wtryskiwania pary do strefy spalania lub recyrkulację spalin. Pożądany efekt to co najmniej 30% obniżenie emisji tlenków azotu. Uzyskane przez autorów wyniki emisji NOx zaprezentowane zostały w pracy w dwojaki sposób: w przeliczeniu na masową emisję tlenków azotu (rys. 1) oraz jako wartość obiektywna w przeliczeniu na α = 1 (rys. 2). W trakcie prowadzonej analizy uwzględniano trzy poziomy ewentualnego wpływu emisji ze spalinami kotłów na zanieczyszczenie atmosfery, co uwzględniono i przedstawiono na rysunku 1. Zestawienie głównych mierzonych i obliczanych wartości, które charakteryzują działanie kotła zestawiono w tabeli 1. W niniejszej publikacji ponadto określone zostały faktyczne poziomy emisji tlenków azotu dla kotłów w stanie eksploatacyjnym a także opracowany został a następnie wdrożony układ zmniejszenia emisji NOX metodą wtryskiwania pary. Dodatkowo autorom udało się określić optymalny tryb pracy systemu zmniejszenia emisji, który pozwolił osiągnąć wymagane zakładane na wstępie 30% zmniejszenie. Zalecany w praktyce tryb pracy kotłów z włączonym systemem zmniejszenia emisji tlenków azotu nie powoduje obniżenia sprawności samego zespołu kotłowego.
The standard sample balance of the boiler showed that the maximum efficiency has been observed in noticeable incompleteness of combustion. The nitrogen oxides which are formed at the highest temperature that is in the absence of chemical incompleteness of combustion are substances that are much more toxic than eg. carbon monoxide. For this reason the team of authors undertook the development and implementation of measures to the reduction of toxic emissions of nitrogen oxides to the atmosphere using boiler DKVR-20-13 with three gas/fuel oil burners GMGB-5.6. The complicated nature of the issue makes it necessary to have an individual solution in each case, in relation to the adjustment of the boiler, taking into account the characteristics and details of all components of the whole boiler-furnace mechanism. The principal problem which was encountered by a team of authors already in the process of conducting research turned out to be a matter of respect to a reference level, which should be referred to the reduction in emissions. The authors have therefore decided to be the reference for the actual take maximum emissions, verifying it previously with a maximum nitrogen oxide emission for these types of devices. In their paper the authors presented and analyzed a number of options to reduce emissions of nitrogen oxides into the atmosphere. Among the methods which were analyzed among others exhaust gas recirculation, injection of steam and boiler room inventory. Preliminary analysis of theoretical as well as experience has allowed the research team to recommend as an effective way to reduce emissions of nitrogen oxides DKVR for boilers operating in industrial and heating mode: a method of injecting steam into the combustion zone or flue gas recirculation. The desired effect is at least 30% reduction in nitrogen oxide emissions. The results obtained by the authors of the NO emission results were presented at work in two ways: in terms of mass emissions of nitrogen oxides (Figure 1) and as an objective value per at alpha = 1 (Figure 2). In the course of their analysis takes into consideration three levels the possible impact of emissions from the flue gas boilers atmospheric pollution, which take into account and are shown in Figure 1. Selection of the main measured or calculated values that characterize the operation of the boiler are summarized in Table 1. This publication also sets forth the actual levels of emissions of nitrogen oxides for boiler in operating condition and has been developed and then implemented the system to reduce emissions NOx using steam injection. In addition, the authors were able to determine the optimal mode of operation of the system to reduce emissions, which helped achieve the required, presupposed a 30% decrease. Recommended in practice mode enabled system boilers to reduce emissions of nitrogen oxides does not reduce the efficiency of the boiler.
Źródło:
Rocznik Ochrona Środowiska; 2016, Tom 18, cz. 1; 565-578
1506-218X
Pojawia się w:
Rocznik Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Legal aspects of low-emission shipping in the light of provisions of “sulphur directive” adopted by the European Union
Autorzy:
Madejska, B.
Powiązania:
https://bibliotekanauki.pl/articles/259460.pdf
Data publikacji:
2013
Wydawca:
Politechnika Gdańska. Wydział Inżynierii Mechanicznej i Okrętownictwa
Tematy:
ship emissions
sulphur dioxide
nitrogen oxides
sulphur directive
MARPOL Annex VI
protection of the environment
control on sulphur emissions
Opis:
Shipping emits a variety of air pollutants: sulphur dioxide (SOx), nitrogen oxides (NOx ), carbon dioxide (CO2 ) and particulate matter PM. Air pollutant emissions from maritime transport can be transported over long distances and thus increasingly contribute to air quality problems. Key environmental regulations (international and European) coming into force in this decade address emissions of SOx , NOx , CO2 and PM to control and limit their impact in the atmosphere. In the European Union, accordingly to the legal regulations, in the sulphur emission control areas the required SOx content of fuel will be reduced from 1.5 % to 0.1 % beginning January 2015. Globally, from 2020 onwards, ships operating in all other European Sea areas will have to use fuels with sulphur content of 0.5 % or less.
Źródło:
Polish Maritime Research; 2013, 4; 87-94
1233-2585
Pojawia się w:
Polish Maritime Research
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Selektywna redukcja katalityczna tlenków azotu w pojazdach spełniających normę emisji Euro VI
Selective Catalytic Reduction of nitrogen oxides in vehicles complaint to Euro VI emission limit
Autorzy:
Sala, R.
Krasowski, J.
Dzida, J.
Powiązania:
https://bibliotekanauki.pl/articles/315641.pdf
Data publikacji:
2017
Wydawca:
Instytut Naukowo-Wydawniczy "SPATIUM"
Tematy:
tlenek azotu NOx
norma Euro VI
spaliny
pojazdy samochodowe
nitrogen oxides NOx
Euro VI
emissions
car vehicles
Opis:
W artykule omówiony został system selektywnej redukcji tlenków azotu w układzie oczyszczania spalin silnika o zapłonie samoczynnym, spełniającym limity normy emisji Euro VI i przeznaczonym do napędu pojazdów ciężarowych oraz autobusów. Przedstawiono wyniki badań emisji tlenków azotu uzyskane w teście homologacyjnym WHTC, który został przeprowadzony w warunkach zimnego oraz ciepłego rozruchu silnika. Układ oczyszczania spalin składał się z reaktora utleniającego (DOC), filtra cząstek stałych (DPF) oraz z systemu selektywnej redukcji katalitycznej (SCR) wraz z układem dozowania wodnego roztworu mocznika. Podczas badań poddano analizie sprawność systemu SCR, określaną jako stopień redukcji szkodliwych tlenków azotu w spalinach, w warunkach dynamicznych zmian obciążeń silnika w teście WHTC. Przedmiotem analizy było ponadto określenie okresu czasu niezbędnego do uzyskania gotowości systemu do rozpoczęcia dozowania mocznika i podjęcia efektywnej pracy po rozruchu zimnego silnika. Zwrócono także uwagę na występujące problemy eksploatacyjne związane z użytkowaniem systemu SCR, takie jak formowanie się osadów stałych mocznika wewnątrz układu i emisja amoniaku za reaktorem. Uzyskane wyniki badań omówiono w aspekcie określenia najlepszej metody oczyszczania spalin z tlenków azotu w silnikach o zapłonie samoczynnym, pod kątem planowego wprowadzenia testów emisji spalin pojazdów w rzeczywistych warunkach drogowych (testy RDE).
The NOx emission aftertreatment of compressed ignition engines has always been a point of concern. The legislative emission limits for heavy duty vehicles constantly tighten the requirements for emissions of NOx. Nowadays it is believed that the most effective and reliable method of NOx reduction is a Selective Catalytic Reduction (SCR) system. The reducing agent of the system is ammonia, delivered and stored on a vehicle as Adblue, an aqueous urea solution. As all catalyst based clean-up systems, SCR activates only when a certain temperature is achieved. Nevertheless, once the system is started, the reduction efficiency of up to 99% can be achieved.
Źródło:
Autobusy : technika, eksploatacja, systemy transportowe; 2017, 18, 6; 1052-1056, CD
1509-5878
2450-7725
Pojawia się w:
Autobusy : technika, eksploatacja, systemy transportowe
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Estimating shipping emissions – A case study for cargo Port of Zadar, Croatia
Autorzy:
Knezević, V.
Pavin, Z.
Čulin, J.
Powiązania:
https://bibliotekanauki.pl/articles/2063981.pdf
Data publikacji:
2021
Wydawca:
Uniwersytet Morski w Gdyni. Wydział Nawigacyjny
Tematy:
Port of Zadar
air pollutant emission
estimating shipping emissions
nitrogen oxides
particulate matter
volatile organic compounds
carbon dioxide
green port
Opis:
Reducing air pollutant emissions and energy consumption, as a necessary step to make ports more sustainable, is one of the crucial tasks and challenges of port management. Some of the port strategies to meet the term “green port” usually include reducing fuel consumption from vessels and vehicles in ports. This paper estimates the emission inventory of maritime traffic for the cargo Port of Zadar. For this research, emissions from cargo ships are estimated in the period from January 01. 2018 until October 01. 2019. The “bottom-up” methodology has been applied for estimating emissions, which includes detailed data on the ship’s characteristics (engine power, the load factor, fuel type, the emission factor) and time spent cruising and hotelling. The emissions from cargo ships have been estimated for three ship’s activities: cruising in the reduced speed zone, hotelling (time spent at berth), and maneuvering. The emission results (tons/year) refer to the pollutants such as nitrogen oxides (NOx), sulphur oxides (SOx), particulate matter (PM), volatile organic compounds (VOC), and carbon dioxide (CO2) which represents greenhouse gases. Estimating emission inventory is the first step for planning effective port air quality control. Some recommendations for reducing emissions in port areas are emphasized in this paper.
Źródło:
TransNav : International Journal on Marine Navigation and Safety of Sea Transportation; 2021, 15, 3; 615--620
2083-6473
2083-6481
Pojawia się w:
TransNav : International Journal on Marine Navigation and Safety of Sea Transportation
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Problems of Nitrogen Oxides Emission Decreasing from Marine Diesel Engines to Fulfill the Limit of Tier 3
Problemy zmniejszenia emisji tlenków azotu z okrętowych silników wysokoprężnych w celu spełnienia limitu emisji 3
Autorzy:
Herdzik, Jerzy
Powiązania:
https://bibliotekanauki.pl/articles/1811800.pdf
Data publikacji:
2019
Wydawca:
Politechnika Koszalińska. Wydawnictwo Uczelniane
Tematy:
nitrogen oxides
marine engine
emissions to the atmosphere
Tier 3 limit
tlenki azotu
silnik wysokoprężny
emisja do atmosfery
poziom emisji 3
Opis:
The paper presents problems of limitation the nitrogen oxides emission from marine diesel engines. The emission of noxious substances from combustion of marine fuels is restricted in respect of the atmosphere protection, International Maritime Organization (IMO) regulations and others. The IMO requirements were determined by time of being in force. The first tier started in 2000 year, the second in 2011, the third is being valid from 2016 on USA waters and in some chosen port areas (from 2021 will be obligatory on Baltic Sea, North Sea and English Channel) and it is a necessity to comply those last requirements. In case of NOx – between the first and second tier the emission was limited 20%, while the third step was limited 80% of the first one. This is a very great challenge, because in nowadays marine diesel engines and marine heavy and diesel oils generally applied, it would seem impossible comply those requirements. It was formed environmental controlled areas of NOx emission (ECA) and they will extend. Governments of some countries (USA, Norway) were introduced on own territorial waters the requirements of NOx and SOx emission. In case of exceeding the limits (or a lack of the proper certificates) it was imposed an ecological charge (a form of tax) or the interdict of entrance on regulated water zones. In the paper it was given an attention to the new challenges for engine producers and ship-owners of fulfilling tier 3 standards or search new substitute solutions. The applying solutions for nitrogen oxides emission limitations cause the decreasing of engine efficiency and increasing the fuel consumption (and carbon dioxide emission) up to ten percent. Due to regulations of marine environment protection they generate additional investment and operation cost for ship-owners and charterers.
W artykule przedstawiono problemy ograniczania emisji tlenków azotu z okrętowych silników wysokoprężnych. W celu ochrony atmosfery przed emisją szkodliwych substancji z procesu spalania paliw okrętowych wprowadzono regulacje Międzynarodowej Organizacji Morskiej (IMO) i inne. Wymagania IMO określają czas wejścia w życie (obowiązywania). Pierwsze ograniczenie emisji tlenków azotu (Tier 1) obowiązuje od 2000 roku, drugie (Tier 2) od 2011, natomiast trzecie (Tier 3) obowiązuje od 2016 roku na wodach amerykańskich i wybranych obszarach portowych (od 2021 roku będzie obowiązywać na Morzu Bałtyckim i Północnym oraz Kanale La Manche) oraz zachodzi konieczność spełnienia tych wymagań. Dla tlenków azotu (NOx) – pomiędzy pierwszym a drugim limitem jest różnica 20%, podczas gdy trzeci limit jest o 80% mniejszy od pierwszego. Jest to wielkie wyzwanie, ponieważ w okrętowych silnikach wysokoprężnych stosuje się paliwa ciężkie i oleje napędowe, wydaje się niemożliwe spełnienie tych wymagań. Utworzono obszary kontroli emisji (ECA) tlenków azotu i te obszary będą się powiększać. Rządy niektórych krajów (USA, Norwegia) wprowadziły własne wymagania na ich wodach terytorialnych odnośnie emisji tlenków azotu i tlenków siarki. W artykule zwrócono uwagę na nowe wyzwania dla producentów silników i armatorów statków w celu spełnienia standardów emisji w limicie Tier 3 lub poszukiwania innych równoważnych rozwiązań. Stosowane rozwiązania ograniczenia emisji tlenków azotu zmniejszają sprawność silników oraz zwiększają zużycie paliwa (i emisji dwutlenku węgla) nawet o dziesięć procent. Z powodu wprowadzenia regulacji chroniących środowisko morskie, generują one dodatkowe koszty inwestycyjne i eksploatacyjne dla armatorów i czarterujących.
Źródło:
Rocznik Ochrona Środowiska; 2019, Tom 21, cz. 1; 659-671
1506-218X
Pojawia się w:
Rocznik Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Technical and environmental assessment of selected heat pump configurations. A case study
Autorzy:
Bugaj, A.
Miniewicz, M.
Powiązania:
https://bibliotekanauki.pl/articles/207176.pdf
Data publikacji:
2014
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
geothermal heat pump
air heat pump
primary energy
simulation model
sulfur dioxide emissions
carbon dioxide emissions
emissions of nitrogen oxides
energy efficiency indicators
environmental impact assessment
gruntowa pompa ciepła
powietrzna pompa ciepła
energia pierwotna
model symulacyjny
emisja dwutlenku siarki
emisja dwutlenku węgla
emisja tlenków azotu
wskaźniki efektywności energetycznej
ocena oddziaływania na środowisko
Opis:
Two heat pump systems with the highest energy performance indicators were chosen for an analysis. Those most efficient systems for heating and cooling are ground source heat pumps (GSHP) and the exhaust air heat pumps (EAHP). Consequently, two cases (case A and case B) with different pump configurations were related to a reference case R represented by gas-fired boilers covering heating needs and compression refrigeration units ensuring cooling needs. Technical assessment in the form of coefficients of performance as well as primary energy ratings were completed. An environmental impact taking into account CO2, SO2 and NOx emissions of analysed heat pump systems was also evaluated.
Źródło:
Environment Protection Engineering; 2014, 40, 2; 143-157
0324-8828
Pojawia się w:
Environment Protection Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies