Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "Metoda Wilsona" wg kryterium: Temat


Wyświetlanie 1-7 z 7
Tytuł:
The application of the Wilson plot method to convective heat transfer - last achievements
Zastosowanie metody Wilsona w zagadnieniach konwekcyjnej wymiany ciepła - omówienie
Autorzy:
Tychanicz-Kwiecień, Maria
Powiązania:
https://bibliotekanauki.pl/articles/2204385.pdf
Data publikacji:
2022
Wydawca:
Politechnika Rzeszowska im. Ignacego Łukasiewicza. Oficyna Wydawnicza
Tematy:
Wilson plot
convective heat transfer
thermal characteristics
heat exchanger
metoda Wilsona
wymiana ciepła
charakterystyka cieplna
wymiennik ciepła
Opis:
The paper discusses and presents the application of the Wilson plot method to the variety of issues related to convective heat transfer. The Wilson plot is a remarkable calculation procedure, which enables the analysis and estimation of convection heat transfer coefficient on the basis of experimental measurements of heat exchanger thermal and flow parameters and the evaluation of corresponding correlation equations. The main facility of the Wilson method is that the heat transfer coefficient can be obtained without the requirement of determining the surface temperature. Much attention was paid to clarify the concept of the standard, original Wilson method as well as its modified versions. The issue was presented in the form of the latest literature review, which featured the investigation of convection coefficients obtained by the Wilson method in the following cases: the flow of nanofluids, refrigerants and other working media in conventional and mini/micro channels and micro-tubes as well as heat transfer under boiling/condensation conditions. The validity of the method utilization has been presented and its future prospects have been specified.
W artykule omówiono i przedstawiono zastosowanie metody Wilsona w różnorodnych zagadnieniach związanych z wymianą ciepła na drodze konwekcji. Metoda Wilsona pozwala na analizę i określenie konwekcyjnego współczynnika przejmowania ciepła na podstawie eksperymentalnych pomiarów parametrów cieplnych i przepływowych badanego wymiennika ciepła oraz zastosowanie lub opracowanie odpowiednich zależności korelacyjnych. Szczególnym atutem metody Wilsona jest możliwość określenia współczynnika przejmowania ciepła bez konieczności pomiaru temperatury powierzchni badanego wymiennika ciepła Dużo uwagi poświęcono wyjaśnieniu koncepcji standardowej, oryginalnej metody Wilsona oraz jej zmodyfikowanych wersji. Zagadnienie zostało przedstawione w formie przeglądu literatury, w którym uwzględniono podsumowanie wyników badań współczynników przejmowania ciepła uzyskanych metodą Wilsona w następujących przypadkach: przepływu nanocieczy, czynników chłodniczych i innych mediów roboczych w kanałach konwencjonalnych i mini/mikrokanałach oraz mikrorurkach, jak również wymianę ciepła podczas wrzenia/kondensacji. Przedstawiono zasadność wykorzystania metody oraz określono jej perspektywy na przyszłość.
Źródło:
Zeszyty Naukowe Politechniki Rzeszowskiej. Mechanika; 2022, z. 94; 77--89
0209-2689
2300-5211
Pojawia się w:
Zeszyty Naukowe Politechniki Rzeszowskiej. Mechanika
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Heat transfer and pressure drop characteristics of the silicone-based plate heat exchanger
Autorzy:
Muszyński, Tomasz
Andrzejczyk, Rafał
Park, Il Wong
Dorao, Carlos Alberto
Powiązania:
https://bibliotekanauki.pl/articles/240347.pdf
Data publikacji:
2019
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
heat transfer coefficient
heat exchangers
enhanced surface
Wilson plot method
współczynnik wnikania ciepła
wymienniki ciepła
czynnik chłodniczy
metoda Wilsona
Opis:
The paper presents an experimental investigation of a silicone based heat exchanger, with passive heat transfer intensification by means of surface enhancement. The main objective of this paper was to experimentally investigate the performance of a heat exchanger module with the enhanced surface. Heat transfer in the test section has been examined and described with precise measurements of thermal and flow conditions. Reported tests were conducted under steady-state conditions for single-phase liquid cooling. Proposed surface modification increases heat flux by over 60%. Gathered data presented, along with analytical solutions and numerical simulation allow the rational design of heat transfer devices.
Źródło:
Archives of Thermodynamics; 2019, 40, 1; 127-143
1231-0956
2083-6023
Pojawia się w:
Archives of Thermodynamics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Heat transfer in helical coil heat exchanger:An experimental parametric study
Autorzy:
Kowalski, Krzysztof
Downarowicz, Dorota
Powiązania:
https://bibliotekanauki.pl/articles/185443.pdf
Data publikacji:
2019
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
helical coil
heat exchanger
condensation
Wilson method
laminar flow
pressure drop
wymiennik ciepła
kondensacja
Metoda Wilsona
przepływ laminarny
Spadek ciśnienia
Opis:
Helical coil heat exchangers are widely used in a variety of industry applications such as refrigerationsystems, process plants and heat recovery. In this study, the effect of Reynolds number and theoperating temperature on heat transfer coefficients and pressure drop for laminar flow conditions wasinvestigated. Experiments were carried out in a shell and tube heat exchanger with a copper coiledpipe (4 mm ID, length of 1.7 m and coil pitch of 7.5 mm) in the temperature range from 243 to 273 K.Air – propan-2-ol vapor mixture and coolant (methylsilicone oil) flowed inside and around the coil,respectively. The fluid flow in the shell-side was kept constant, while in the coil it was varied from 6.6to 26.6 m/s (the Reynolds number below the critical value of 7600). Results showed that the helicalpipe provided higher heat transfer performance than a straight pipe with the same dimensions. Theconvective coefficients were determined using the Wilson method. The values for the coiled pipe werein the range of 3–40 W/m2·K. They increased with increasing the gas flow rate and decreasing thecoolant temperature.
Źródło:
Chemical and Process Engineering; 2019, 40, 1; 101--114
0208-6425
2300-1925
Pojawia się w:
Chemical and Process Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Effect of nanofluid concentration on two-phase thermosyphon heat exchanger performance
Autorzy:
Cieśliński, J. T.
Powiązania:
https://bibliotekanauki.pl/articles/240904.pdf
Data publikacji:
2016
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
two-phase thermosyphon
heat exchanger
nanofluid
Wilson method
termosyfon dwufazowy
wymiennik ciepła
metoda Wilsona
Opis:
An approach – relaying on application of nanofluid as a working fluid, to improve performance of the two-phase thermosyphon heat exchanger (TPTHEx) has been proposed. The prototype heat exchanger consists of two horizontal cylindrical vessels connected by two risers and a downcomer. Tube bundles placed in the lower and upper cylinders work as an evaporator and a condenser, respectively. Distilled water and nanofluid water-Al2O3 solution were used as working fluids. Nanoparticles were tested at the concentration of 0.01% and 0.1% by weight. A modified Peclet equation and Wilson method were used to estimate the overall heat transfer coefficient of the tested TPTHEx. The obtained results indicate better performance of the TPTHEx with nanofluids as working fluid compared to distilled water, independent of nanoparticle concentration tested. However, increase in nanoparticle concentration results in overall heat transfer coefficient decrease of the TPTHEx examined. It has been observed that, independent of nanoparticle concentration tested, decrease in operating pressure results in evaporation heat transfer coefficient increase.
Źródło:
Archives of Thermodynamics; 2016, 37, 2; 23-40
1231-0956
2083-6023
Pojawia się w:
Archives of Thermodynamics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Heat transfer in plate heat exchanger channels: Experimental validation of selected correlation equations
Autorzy:
Cieśliński, J. T.
Fiuk, A.
Typiński, K.
Siemieńczuk, B.
Powiązania:
https://bibliotekanauki.pl/articles/240555.pdf
Data publikacji:
2016
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
PHEx
Wilson method
correlations
metoda Wilsona
korelacje
Opis:
This study is focused on experimental investigation of selected type of brazed plate heat exchanger (PHEx). The Wilson plot approach was applied in order to estimate heat transfer coefficients for the PHEx passages. The main aim of the paper was to experimentally check ability of several correlations published in the literature to predict heat transfer coefficients by comparison experimentally obtained data with appropriate predictions. The results obtained revealed that Hausen and Dittus-Boelter correlations underestimated heat transfer coefficient for the tested PHEx by an order of magnitude. The Aspen Plate code overestimated heat transfer coefficient by about 50%, while Muley-Manglik correlation overestimated it from 1% to 25%, dependent on the value of Reynolds number and hot or cold liquid side.
Źródło:
Archives of Thermodynamics; 2016, 37, 3; 19-29
1231-0956
2083-6023
Pojawia się w:
Archives of Thermodynamics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Recuperator with microjet technology as a proposal for heat recovery from low-temperature sources
Autorzy:
Wajs, J.
Mikielewicz, D.
Fornalik-Wajs, E.
Bajor, M.
Powiązania:
https://bibliotekanauki.pl/articles/240624.pdf
Data publikacji:
2015
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
heat exchanger
microjet technology
heat recovery
Wilson plot method
wymiennik ciepła
odzysk ciepła
metoda Wilsona
Opis:
A tendency to increase the importance of so-called dispersed generation, based on the local energy sources and the working systems utilizing both the fossil fuels and the renewable energy resources is observed nowadays. Generation of electricity on industrial or domestic scale together with production of heat can be obtained for example through employment of the ORC systems. It is mentioned in the EU directive 2012/27/EU for cogenerative production of heat and electricity. For such systems the crucial points are connected with the heat exchangers, which should be small in size but be able to transfer high heat fluxes. In presented paper the prototype microjet heat exchanger dedicated for heat recovery systems is introduced. Its novel construction is described together with the systematical experimental analysis of heat transfer and flow characteristics. Reported results showed high values of the overall heat transfer coefficient and slight increase in the pressure drop. The results of microjet heat exchanger were compared with the results of commercially available compact plate heat exchanger.
Źródło:
Archives of Thermodynamics; 2015, 36, 4; 49-64
1231-0956
2083-6023
Pojawia się w:
Archives of Thermodynamics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Optymalizacja bioprodukcji kwasu cytrynowego w hodowli wgłębnej Aspergillus niger prowadzonych w obecności Tweenu 80
Optimization of citric acid bioproduction in Aspergillus niger submerged cultures supplemented with Tween 80
Autorzy:
Kałuża, M.
Sadowski, Z.
Powiązania:
https://bibliotekanauki.pl/articles/2072426.pdf
Data publikacji:
2013
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
optymalizacja
metoda Boxa-Wilsona
kwas cytrynowy
Tween 80
Aspergillus niger
optimization
Box-Wilson method
citric acid
Opis:
Celem badań była maksymalizacja bioprodukcji kwasu cytrynowego w wgłębnych hodowlach A. niger prowadzonych w obecności Tweenu 80. Przeprowadzono optymalizację składu podłoża hodowlanego i warunków procesu fermentacji cytrynowej, korzystając z metody zaproponowanej przez Boxa i Wilsona. Wynikiem eksperymentu optymalizacyjnego był wzrost stężenia kwasu cytrynowego w prowadzonych hodowlach z 47,01 do 66, 37 g/dm3 oraz obniżenie zawartości białego cukru w nowo zdefiniowanym podłożu fermentacyjnym.
The aim of these experiments was to enhance the citric acid bioproduction in Aspergillus niger submerged cultures supplemented with Tween 80. To maximize the effect of citric acid fermentation, the optimization of culture medium and fermentation conditions was performed using a method proposed by Box and Wilson. The optimization result was the enhancement of citric acid concentration in fermentation broths from 47.01 to 66.37 g/dm3 and the reduction of sucrose in redefined fermentation medium.
Źródło:
Inżynieria i Aparatura Chemiczna; 2013, 4; 332--333
0368-0827
Pojawia się w:
Inżynieria i Aparatura Chemiczna
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-7 z 7

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies