Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "MPP" wg kryterium: Temat


Wyświetlanie 1-7 z 7
Tytuł:
Efficiency of maximum power point tracking in photovoltaic system under variable solar irradiance
Autorzy:
Marańda, W.
Piotrowicz, M.
Powiązania:
https://bibliotekanauki.pl/articles/200627.pdf
Data publikacji:
2014
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
photovoltaics
MPP-tracking
inverter efficiency
fotowoltaika
śledzenie
MPP
sprawność falownika
Opis:
Field conditions decrease the energy output of photovoltaic (PV) systems, mainly due to excessive temperatures. However, in regions with moderate ambient temperatures, as in Poland, solar energy is commonly delivered with highly fluctuating irradiance. This introduces yet another source of energy losses due to the non-ideal tracking of actual position of Maximum Power Point (MPP). Majority of PV-systems are equipped with DC/AC and grid-connected inverter. Since the solar energy flux is variable, an adequate MPP-tracking algorithm is required to handle a wide range of load levels and face rapid changes of input power. Along with the essential DC/AC conversion, the quality of MPP-tracking must also be taken into account in evaluation of inverter efficiency. The tracking in dynamic conditions has been addressed only recently. Several algorithms has been studied theoretically, experimentally or in laboratory conditions by applying artificial input test-patterns. This work takes the opposite approach by applying the recorded real-life solar irradiance and simulating the tracking behavior to study the problem for true field conditions in Poland. The simulation uses the unique high-quality irradiance data collected with 200 ms time resolution. The calculation of both static and dynamic MPP-tracking efficiency has been performed for representative variable-cloudy day, applying commonly used Perturb&Observe tracking algorithm.
Źródło:
Bulletin of the Polish Academy of Sciences. Technical Sciences; 2014, 62, 4; 713-721
0239-7528
Pojawia się w:
Bulletin of the Polish Academy of Sciences. Technical Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Układy śledzące punkt maksymalnej mocy w inwerterach stosowanych w instalacjach fotowoltaicznych
Systems follow the maximum power point in inverters used in photovoltaic installations
Autorzy:
Trzmiel, G.
Powiązania:
https://bibliotekanauki.pl/articles/377415.pdf
Data publikacji:
2016
Wydawca:
Politechnika Poznańska. Wydawnictwo Politechniki Poznańskiej
Tematy:
instalacja fotowoltaiczna
PV
inwerter
MPP tracker
punkt maksymalnej mocy
Opis:
W pracy przedstawiono możliwości stosowania różnych algorytmów poszukiwania punktów maksymalnej mocy w instalacjach fotowoltaicznych (PV). Wspomniano o różnych sposobach zwiększania sprawności systemów PV i uzysków energii elektrycznej. Dokonano przeglądu stosowanych inwerterów (falowników) ze względu na kilka kryteriów. Przedstawiono również celowość stosowania oraz funkcjonalność układów śledzących punkt maksymalnej mocy, które wchodzą w skład inwerterów. Zwrócono uwagę na podstawowe zasady doboru różnych rodzajów inwerterów. Główną częścią pracy jest charakterystyka najczęściej stosowanych algorytmów pracy układów śledzących punkt maksymalnej mocy.
The paper presents the possibility of using different algorithms to search for the point of maximum power in installations of photovoltaic (PV). Mentioned about different ways to increase the efficiency of PV systems and electricity yields. Overview of the inverters due to several criteria was made. Also presented the desirability of the use and functionality of the systems tracking the maximum power point, which are included in the inverters. Attention was drawn to the basic principles for the selection of different types of inverters. The main part of the paper is the characteristic of the most commonly used circuits tracking the maximum power point algorithms.
Źródło:
Poznan University of Technology Academic Journals. Electrical Engineering; 2016, 87; 23-35
1897-0737
Pojawia się w:
Poznan University of Technology Academic Journals. Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Study of Single Sensor Based Maximum Power Point Tracking Techniques for Solar Water Pumping System
Autorzy:
Daoud, A.
Midoun, A.
Powiązania:
https://bibliotekanauki.pl/articles/262773.pdf
Data publikacji:
2009
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie
Tematy:
MPP
buck converter
microcontroller
motor-pump
tachometer
pressure sensor
Opis:
This paper describes new techniques of maximum power point (MPP) tracking for solar water pumping system. The latter system consists of a PV array, a DC/DC buck converter and a universal motor coupled to a centrifugal pump. A conventional hill climbing method is employed to seek the MPP using the motor-pump rotation speed or the pump outlet pressure information. Experimental results are presented and a comparison with conventional algorithm which requires both voltage and current sensors is provided.
Źródło:
Electrical Power Quality and Utilisation. Journal; 2009, 15, 2; 23-27
1896-4672
Pojawia się w:
Electrical Power Quality and Utilisation. Journal
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Sensitivity analysis of a new approach to photovoltaic parameters extraction based on the total least squares method
Autorzy:
Mesbahi, Oumaima
Tlemçani, Mouhaydine
Janeiro, Fernando M.
Hajjaji, Abdeloawahed
Kandoussi, Khalid
Powiązania:
https://bibliotekanauki.pl/articles/2052125.pdf
Data publikacji:
2021
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
photovoltaic modules
parameter extraction
total least squares
MPP
sensitivity analysis
Opis:
The degradation of photovoltaic modules and their subsequent loss of performance has a serious impact on the total energy generation potential. The lack of real-time information on the output power leads to additional losses since the panels may not be operating at their optimal point. To understand the behaviour, numerically simulate the characteristics and identify the optimal operating point of a photovoltaic cell, the parameters of an equivalent electrical circuit must first be identified. The aim of this work is to develop a total least-squares based algorithm which can identify those parameters from the output voltage and current measurements, taking into consideration the uncertainties on both measured quantities. This work presents a comparative study of the Ordinary Least Squares (OLS) and Total Least Squares (TLS) approaches to the estimation of the parameters of a photovoltaic cell.
Źródło:
Metrology and Measurement Systems; 2021, 28, 4; 751-765
0860-8229
Pojawia się w:
Metrology and Measurement Systems
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Optimisation of Multistep Cavity Configuration to Extend Absorption Bandwidth of Micro Perforated Panel Absorber
Autorzy:
Falsafi, I.
Ohadi, A.
Powiązania:
https://bibliotekanauki.pl/articles/176825.pdf
Data publikacji:
2018
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
micro perforated panel
MPP
multistep cavity
absorption bandwidth
optimisation
impedance tube
Opis:
Micro perforated panel (MPP) absorber is a new form of acoustic absorbing material in comparison with porous ones. These absorbers are considered as next generation ones and the best alternative for traditional porous materials like foams. MPP combined with a uniform air gap constructs an absorber which has high absorption but in a narrow bandwidth of frequency. This characteristic makes MPPAs insufficient for practical purposes in comparison with porous materials. In this study instead of using a uniform air gap behind the MPP, the cavity is divided into several partitions with different depth arrangement which have parallel faces. This method improves the absorption bandwidth to reach the looked for goal. To achieve theoretical absorption of this absorber, equivalent electro-acoustic circuit and Maa’s theory (MAA, 1998) are employed. Maa suggested formulas to calculate MPP’s impedance which show good match with experimental results carried out in previous studies. Electro-acoustic analogy is used to combine MPP’s impedance with acoustic impedances of complex partitioned cavity. To verify the theoretical analyses, constructed samples are experimentally tested via impedance tube. To establish the test, a multi-depth setup facing a MPP is inserted into impedance tube and the absorption coefficient is examined in the 63-1600 Hz frequency range. Theoretical results show good agreement compared to measured data, by which a conclusion can be made that partitioning the cavity behind MPP into different depths will improve absorption bandwidth and the electro-acoustic analogy is an appropriate theoretical method for absorption enhancement research, although an optimisation process is needed to achieve best results to prove the capability of this absorber. The optimisation process provides maximum possible absorption in a desired frequency range for a specified cavity configuration by giving the proper cavity depths. In this article numerical optimisation has been done to find cavity depths for a unique MPP.
Źródło:
Archives of Acoustics; 2018, 43, 2; 187-195
0137-5075
Pojawia się w:
Archives of Acoustics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Static and dynamic MPP-tracking efficiency of PV-inverter using recorded irradiance
Autorzy:
Marańda, W.
Piotrowicz, M.
Powiązania:
https://bibliotekanauki.pl/articles/397987.pdf
Data publikacji:
2013
Wydawca:
Politechnika Łódzka. Wydział Mikroelektroniki i Informatyki
Tematy:
photovoltaics
MPP-tracking
PV inverter
tracking efficiency
fotowoltaika
śledzenie punktu mocy maksymalnej
przekształtnik PV
efektywność śledzenia
Opis:
This paper investigates the energy losses introduced by Maximum Power Point Tracking operation of photovoltaic (PV) inverter. In contrast to other studies, this evaluation has been done with the recorded real-life solar irradiance data applied to the simulation of the PV-generator and tracking algorithm. The true MPP output of photovoltaic generator has been calculated with electro-thermal model and the simulation has been carried out with 1 s time resolution. The efficiency results have been presented for both static and dynamic MPP-tracking investigated With basic and simplified Perturb&Observe algorithm with several tracking speed rates. In addition to the simulation, the inverter efficiency measurements for field- installed inverter have been presented.
Źródło:
International Journal of Microelectronics and Computer Science; 2013, 4, 4; 181-185
2080-8755
2353-9607
Pojawia się w:
International Journal of Microelectronics and Computer Science
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-7 z 7

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies