Tytuł:
Splenic abcesses as infectious complication following implantation of left ventricular asssist device - case report
Autorzy:
Gajda, Sławomir
Szczepanik, Anna M
Religa, Grzegorz
Misiak, Andrzej
Szczepanik, Andrzej B
Powiązania:
https://bibliotekanauki.pl/articles/1393452.pdf
Data publikacji:
2017
Wydawca:
Index Copernicus International
Tematy:
splenic abscesses
splenectomy
left ventricular assist device (LVAD)
infection
Opis:
Left ventricular assist device (LVAD) is one of the modern management therapies in patients with advanced heart failure, and it serves as a bridge to heart transplantation or even as destination therapy. However, it is burdened with a high risk of thromboembolic, hemorrhagic, and infectious complications despite prophylactic management. Splenic abscesses, as septic complications following implantation of mechanical ventricular support, have not yet been described in the literature. We report of a patient with severe left ventricular insufficiency (NYHA II/III), pulmonary hypertension, and arrhythmia who underwent implantation of the Heart Ware® pump for left ventricular support with simultaneous tricuspidvalvoplasty, as a bridge therapy to heart transplantation. During two years after LVAD implantation, the patient had three MRSA skin infections, localized at the exit site of the drive-line connecting the artificial ventricle with external unit, that were complicated by sepsis and treated with broad-spectrum antibiotics. A few months later, abdominal CT revealed two abscesses in the spleen, and the patient was qualified for splenectomy. Open splenectomy was performed under full-dose anticoagulant therapy with continuous intravenous infusions of unfractionated heparin (UFH). The intra- and postoperative course was uneventful. UFH therapy was continued for 6 days, and oral anticoagulation was re-administered on day 4 after surgery. The patient was discharged on day 7 after surgery with primary healed wound. Open splenectomy, performed with full-dose anticoagulant therapy, proved to be an effective and definitive method of treatment without any complications.
Źródło:
Polish Journal of Surgery; 2017, 89, 1; 61-65
0032-373X
2299-2847
Pojawia się w:
Polish Journal of Surgery
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
A new hybrid (hydro-numerical) model of the circulatory system
Autorzy:
Darowski, M.
Kozarski, M.
Ferrari, G.
Zieliński, K.
Górczyńska, K.
Szczepanowski, A.
Pałko, K. J.
Fresiello, L.
Di Molfetta, A.
Powiązania:
https://bibliotekanauki.pl/articles/199804.pdf
Data publikacji:
2013
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
lumped parameter circulatory model
hybrid hydro-numerical models
impedance transformers
LVAD assistance
variable elastance
Opis:
The paper presents a hybrid (hydro-numerical) circulatory model built to be used as a complementary tool for clinical purposes. It was developed at the Institute of Biocybernetics and Biomedical Engineering - Polish Academy of Sciences (Poland) in co-operation with the Institute of Clinical Physiology - National Council of Research (Italy). Main advantages of the model are: 1) high accuracy and repeatability of parameters setting, characteristic of numerical solutions, 2) maximum flexibility achieved by implementing the largest possible number of the model’s elements in the numerical way, 3) ability to test mechanical heart assist devices provided by special computer applications; in the model two physically different signal environments - numerical and hydraulic - are connected by special impedance transformers interfacing physical and numerical parts of the model; 4) eliminating flowmeters, as the voltage controlled flow sources embedded in the system provide information on flows. In vitro tests were performed to evaluate the circulatory model: a) modelling and simulation of physiological and pathological states parameters vs. left ventricular end-systolic elastance (Emax l) and rest volume (Vol) variations, b) testing the effect of LVAD counterpulsation on circulatory hemodynamics and ventricular energetics; it resulted in the increase of total cardiac output (COLV tot) from pathological value 3.8 to 5.4 l·min−1, mean aortic pressure mPas from 67.8 to 96.1 mmHg and in the decrease of left atrial pressure mPla from 15.7 to 7.7 mmHg and External Work nEW by 37.5%. The model was verified based on literature data.
Źródło:
Bulletin of the Polish Academy of Sciences. Technical Sciences; 2013, 61, 4; 993-1003
0239-7528
Pojawia się w:
Bulletin of the Polish Academy of Sciences. Technical Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Modelowanie układu krążenia z możliwością równoległego wspomagania pracy komór serca w pakiecie programowym PExSim
Modeling of circulatory system with parallel assist device using PExSim software platform
Autorzy:
Golnik, A.
Fajdek, B.
Janiszowski, K.
Powiązania:
https://bibliotekanauki.pl/articles/277634.pdf
Data publikacji:
2010
Wydawca:
Sieć Badawcza Łukasiewicz - Przemysłowy Instytut Automatyki i Pomiarów
Tematy:
modelowanie układu krążenia
modelowanie urządzeń wspomagających pracę komory serca
LVAD
PExSim
modelling of human circulatory system
modelling of ventricular assist device
Opis:
Niniejszy artykuł zawiera opis modelu układu krążenia wykonany w pakiecie programowym PExSim. Pozwala on na przeprowadzenie symulacji numerycznych pracy układu krążenia. Jest to celowe w wielu zagadnieniach badawczych, może być przydatne do celów testowania urządzeń wspomagających, jak i użyteczne w zastosowaniach edukacyjnych. Opisane zostały modele urządzenia wspomagającego pracę serca oraz poszczególnych elementów układu krążenia. Przedstawiono wyniki symulacji pracy układu krążenia dla stanów: fizjologicznego prawidłowego, patologicznego oraz przy wspomaganiu lewokomorowym.
The paper presents a numerical model of human circulatory system implemented as a part of PExSim application. Individual components of the human circulatory system and ventricular assist device are described. The examples of typical application are presented and the results of simulations for healthy, pathological and pathological with heart support conditions are included.
Źródło:
Pomiary Automatyka Robotyka; 2010, 14, 11; 100-105
1427-9126
Pojawia się w:
Pomiary Automatyka Robotyka
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-3 z 3

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies