Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "LIDAR" wg kryterium: Temat


Tytuł:
Natural water fluorescence characteristics based on lidar investigations of a surface water layer polluted by an oil film; the Baltic cruise - Mai 2000
Autorzy:
Drozdowska, V.
Babichenko, S.
Lisin, A.
Powiązania:
https://bibliotekanauki.pl/articles/48468.pdf
Data publikacji:
2002
Wydawca:
Polska Akademia Nauk. Instytut Oceanologii PAN
Tematy:
oil pollution
surface water
fluorescence
natural sea water
Baltic Sea
lidar investigation
component
Opis:
Several sea and laboratory experiments have been carried out to detect and determine the fluorescence characteristics of seawater and its natural fluorescing components and to analyse the influence of oil in the surface water layer on the lidar-induced return signal. The aim of the laboratory investigations was to create a database of different natural water types and of water polluted with Petrobaltic oil. During the r/v ‘Oceania’ cruise in the southern Baltic Sea two lidar methods were applied simultaneously to detect and analyse the influence of the fluorescence emission of oil on the fluorescence spectrum of seawater. Detection of oil pollution can be used to correct the fluorescent factors of fluorescing components on the basis of natural seawater fluorescence spectra.
Źródło:
Oceanologia; 2002, 44, 3
0078-3234
Pojawia się w:
Oceanologia
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Dependence of the surf zone aerosol on wind direction and wind speed at a coastal site on the Baltic Sea
Autorzy:
Zielinski, T.
Powiązania:
https://bibliotekanauki.pl/articles/48813.pdf
Data publikacji:
2003
Wydawca:
Polska Akademia Nauk. Instytut Oceanologii PAN
Tematy:
meteorological condition
surf zone
aerosol
coastal site
Baltic Sea
lidar
wind
Opis:
Since 1992 lidar-based measurements have been carried out under various meteorological conditions and at various times of the year. The aerosol optical properties were determined in the marine boundary layer as a function of altitude using such factors as wind direction, duration and velocity and aerosol size distribution and concentration. It was confirmed that in all cases, the total aerosol concentration, size distribution and aerosol extinction increase with wind speed but decrease with altitude. In the range of wind velocities from 1 to 15 m s−1 the mean aerosol optical thickness of the atmosphere (VIS) obtained from the lidar varied from 0.1 to 0.38 for offshore winds and from 0.01 to about 0.1 for onshore winds, while the ˚Angstr¨om parameter for VIS oscillated around 0.65 for onshore winds and around 1 for offshore winds. Both parameters depended strongly on the history of the air mass above the Baltic Sea. Such aerosol optical thicknesses are in agreement with those obtained by other researchers in the Baltic Sea area.
Źródło:
Oceanologia; 2003, 45, 3
0078-3234
Pojawia się w:
Oceanologia
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Pozyskiwanie numerycznego modelu powierzchni topograficznej (NMPT) w oparciu o dane wysokościowe pochodzące z lotniczego skanera laserowego
Derivation of digital terrain model (DTM) from elevation laser scanner data
Autorzy:
Marmol, U.
Powiązania:
https://bibliotekanauki.pl/articles/130326.pdf
Data publikacji:
2003
Wydawca:
Stowarzyszenie Geodetów Polskich
Tematy:
LIDAR
algorytm
NMPT
FFT
lidar
algorithm
DTM
Opis:
Lotniczy skaning laserowy (LIDAR – Light Detection And Ranging) jest nową, dynamicznie rozwijającą się metodą pozyskiwania informacji o powierzchni terenu. Pomiar laserowy dostarcza informacji w postaci trójwymiarowej „chmury punktów” nieregularnie próbkowanych, zarówno o powierzchni topograficznej jak również o innych strukturach badanego terenu (budynki, roślinność itp.). W wielu opracowaniach obszarem zainteresowań jest głównie powierzchnia topograficzna. Proces eliminacji punktów pokrycia terenu, zwany także filtracją stanowi jeden z głównych problemów przetwarzania danych laserowych. W ostatnich latach zostały opracowane algorytmy do automatycznej filtracji danych laserowych. Niestety, istniejące metody i oprogramowania posiadają jeszcze widoczne ograniczenia i nadal niezbędny jest znaczący, czasochłonny, interaktywny udział operatora. W niniejszym artykule przedstawiono analizę porównawczą pomiędzy algorytmem filtracyjnym opartym na FFT, badanym obecnie w Zakładzie Fotogrametrii i Informatyki Teledetekcyjnej AGH a filtracją metodą liniowej predykcji opracowaną w Instytucie Fotogrametrii i Teledetekcji Uniwersytetu Technicznego w Wiedniu. Głównym celem badań była kontrola wiarygodności i efektywności algorytmu opartego na FFT. Uzyskane wyniki badań udowodniły, że metoda ta w sposób właściwy eliminuje punkty pokrycia terenu z danych laserowych. Konieczna jest dalsza weryfikacja algorytmu dla różnych form ukształtowania i pokrycia powierzchni topograficznej.
Airborne laser altimetry (LIDAR – Light Detection and Ranging) is a relatively new method for the acquisition of information of terrain surface. A laser scanning system generates a 3-dimensional clouds of points with irregular spacing. The data consists of the mixture of terrain surface and non-surface points (buildings, vegetation). The separation of ground points from the other points located on top of buildings, vegetation or other objects above ground is one of the major problems. Algorithms and software used for the surface reconstruction have limitations that should be studied and overcome. Removing non – ground points from LIDAR data sets i.e. filtering is still a challenging task. The paper presents a comparative analysis of two filtering methods: FFT based algorithm (a new method investigated at the Department of Photogrammetry and Remote Sensing Informatics at the University of Science and Technology in Cracow) and linear prediction method developed at the Institute of Photogrammetry and Remote Sensing at the Vienna University of Technology . The main purpose of this analysis is to verify FFT based method. FFT based algorithm demonstrate promising results of the terrain surface reconstruction (DTM). However, further investigation is required to verify the reliability and accuracy of filtering algorithm on different types of terrain.
Źródło:
Archiwum Fotogrametrii, Kartografii i Teledetekcji; 2003, 13b; 419-426
2083-2214
2391-9477
Pojawia się w:
Archiwum Fotogrametrii, Kartografii i Teledetekcji
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Dokładność opracowań z wykorzystaniem pomiaru metodą skaningu laserowego - LIDAR. Standard ASPRS
Accuracy of mapping production based on laser scanning - LiDAR. ASPRS standards
Autorzy:
Tukaj, R.
Powiązania:
https://bibliotekanauki.pl/articles/129915.pdf
Data publikacji:
2004
Wydawca:
Stowarzyszenie Geodetów Polskich
Tematy:
skaning laserowy
LIDAR
pomiar geodezyjny
laser scanning
geodetic measurement
Opis:
Artykuł traktuje na temat standardów tworzonych z myślą o uporządkowaniu kwestii związanych z dokładnością danych pozyskiwanych metodą skanningu laserowego LiDAR. Szeroko opisany został standard wprowadzany przez 161 American Society for Photogrammetry and Remote Sensing. Podano też przykładowe dokładności uzyskane na projektach realizowanych w firmie Tukaj Mapping Central Europe.
This article intends to point the main idea of creating and classifying problems connected to accuracy o f data from laser scanning technology - LIDAR. It was widely described by American Society for Photogrammetry and Remote Sensing. As samples there is data shown based on projects done by TUKAJ MAPPING CENTRAL EUROPE.
Źródło:
Archiwum Fotogrametrii, Kartografii i Teledetekcji; 2004, 15; 41-47
2083-2214
2391-9477
Pojawia się w:
Archiwum Fotogrametrii, Kartografii i Teledetekcji
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Preliminary results of lidar based studies of the aerosol vertical distribution in the lower troposphere over urban coastal areas
Autorzy:
Halas, M.
Blaszczak, Z.
Grabowski, J.
Papayannis, A.
Zielinski, T.
Powiązania:
https://bibliotekanauki.pl/articles/48171.pdf
Data publikacji:
2004
Wydawca:
Polska Akademia Nauk. Instytut Oceanologii PAN
Tematy:
vertical profile
aerosol
urban area
lidar
troposphere
coastal area
Opis:
The paper reports the results of lidar measurements performed in the lower troposphere during several measurement sessions in Athens (Greece) in 2000. For the sake of comparison, results of a similar study performed in Kołobrzeg (Poland) in 2001 are also given. These data indicate that the exhaust gases produced by motor transportation in the cities resulted in the formation of an inversion layer. The rate of convection of the inversion layer depends on the intensity of sunlight, the strength of winds and the morphology of the land. The inversion layer reaches the highest altitudes in the middle of summer, lower in early and late summer and the lowest in autumn. Over the sea the inversion layer altitude extends to several meters, but on moving inland it rises to a fewh undred meters.
Źródło:
Oceanologia; 2004, 46, 3
0078-3234
Pojawia się w:
Oceanologia
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Kamera cyfrowa Leica ADS40, skaner laserowy Leica ALS50 – doświadczenia produkcyjne
Airborne digital sensor Leica ADS40 and laser scanner ALS50, workshop experiences
Autorzy:
Boczar, S.
Dąbrowski, R.
Fedorowicz-Jackowski, W.
Zych, J.
Powiązania:
https://bibliotekanauki.pl/articles/129870.pdf
Data publikacji:
2006
Wydawca:
Stowarzyszenie Geodetów Polskich
Tematy:
kamera cyfrowa
LIDAR
numeryczny model terenu
ortofotomapa
Opis:
Ostatnie dwie dekady to era rewolucji w fotogrametrii. Począwszy od skanerów fotogrametrycznych poprzez zautomatyzowane i coraz szybsze cyfrowe stacje robocze, obecnie jesteśmy świadkami implementacji kamer cyfrowych o rozdzielczości podobnej lub większej niż kamery analogowe. Ostatni krok przejścia od technik analogowych do cyfrowych można dziś uznać za dokonany. Czołowi producenci kamer lotniczych obrali różne podejścia do zagadnienia cyfrowego obrazowania. Obecnie możemy wyróżnić dwie zasadnicze idee konstrukcji cyfrowych kamer lotniczych: liniową - konstrukcyjnie zbliżona do sensorów satelitarnych, jak np. QuickBird lub powierzchniową - konstrukcyjnie podobna do kamer analogowych, co nie wymaga zasadniczej zmiany oprogramowania. Jedną z ciekawszych konstrukcji kamer dostępnych na rynku oferuje obecnie firma Leica Geosystems. Kamera Leica ADS40 jest skanerem linijkowym, obrazującym powierzchnię ziemi w 8 kanałach spektralnych (2 panchromatyczne, 2 czerwone, 2 zielone, niebieski i podczerwień), w trzech kierunkach (wstecz, nadirowo, w przód). Pozyskane obrazy umożliwiają generowanie kompozycji w barwach naturalnych i w podczerwieni. Kanały panchromatyczne rejestrowane są z wychyleniem sensora wstecz i w przód umożliwiając automatyczne lub manualne pozyskiwanie i edycję lub weryfikację informacji wysokościowej. Wszystkie kanały mają równą rozdzielczość – po 12 000 elementów w każdej linii. Dzięki temu wszystkie zobrazowania są równie szczegółowe, co eliminuje potrzebę stosowania metody wyostrzania (pan-sharpening) obrazów wielospektralnych, często konieczna w przypadku kamer z matrycą powierzchniową. Leica ADS40 jest jedną z najlepiej sprzedających się fotogrametrycznych 'kamer' cyfrowych. Do dziś sprzedano ponad 50 egzemplarzy ADS40. W nowoczesnej fotogrametrii coraz powszechniejsze staje się zastosowanie skanerów laserowych LIDAR. Firma Leica Geosystems również w tym segmencie oferuje narzędzie: skaner laserowy Leica ALS50 rejestrujący nawet do 4 odbić wiązki laserowej. Wielokrotność odbić wiązki pozwala na otrzymanie precyzyjnych modeli wysokościowych. Dzięki filtracji pozyskanych z ALS50 danych możliwe jest wygenerowanie np. numerycznego modelu terenu (NMT) i numerycznego model powierzchni terenu (NMPT). Jednoczesne zastosowanie kamery Leica ADS40 i skanera laserowego Leica ALS50 zapewnia otrzymanie unikalnego zestawu zobrazowań i złożonej informacji wysokościowej. W artykule przedstawiono doświadczenia produkcyjne firmy GEOSYSTEMS Polska sp. z o.o. uzyskane w trakcie realizacji projektu z zastosowaniem skanera Leica ALS50 i kamery Leica ADS40. Przedstawiono cały cykl produkcyjny zrealizowany w środowisku Leica Photogrammetry Suite (LPS). W artykule zamieszczono fragmenty produktów końcowych: różne rodzaje ortofotomap i numerycznych modeli wysokości. Projekt zrealizowany przez GEOSYSTEMS Polska sp. z o.o. był pierwszym projektem w Polsce, w którym jednocześnie wykorzystano obydwa urządzenia firmy Leica Geosystems.
In the last two decades, photogrammetry has undergone a digital revolution. Photogrammetric scanners and digital workstations have greatly advanced image processing. The development of airborne digital cameras in recent years has brought image quality to levels comparable, or sometimes better than, that obtained with analog cameras. The leading manufacturers’ digital imaging systems have sided with two opposing approaches to airborne image capturing: linear sensor, similar to satellite pushbroom sensor, e.g. the one used by the QuickBird satellite, and frame sensor, which eases the software-related transition from analog to digital image capturing. Leica Geosystems has used the linear sensor approach to develop one of the most interesting cameras available on the market today – the Leica ADS40 (Airborne Digital Scanner). The camera acquires images simultaneously in 3 directions (backward, nadir, forward) and in 8 spectral bands (2 panchromatic, 2 red, 2 green, blue and near infrared). This allows for later generation of various types of orthophotomaps: panchromatic, RGB or FCIR (with near infrared band). Panchromatic bands are acquired with backward and forward looking angles. Panchromatic images may be used for DEM/DTM production or verification. All spectral bands have the same resolution – 12 000 pixels per line which eliminates the use of pan sharpening methods commonly applied in digital frame cameras. Leica ADS40 and Leica ALS50 (Airborne Laser Scanner) can be used simultaneously to obtain a unique dataset: complex imagery set and fast and accurate elevation information. Leica ADS40 is already one of the best selling airborne digital sensors. Leica Geosystems have sold over 50 ADS40 cameras worldwide. In modern photogrammetry, laser scanning (LIDAR) is becoming more common. For such applications, Leica Geosystems offers the Leica ALS50 Airborne Laser Scanner. ALS50 allows users to register up to 4 reflections of a laser bundle. Multiple reflection processing gives a unique opportunity to work out various types of elevation models. After filtering the ALS50 data, it is possible to produce accurate DTMs and DEMs. This paper presents the workshop experience Geosystems Polska sp. z o.o. has gathered while processing data produced by Leica ADS40 and Leica ALS50 cameras. The data was captured by TerraDigital GmBH during a photogrammetric flight over Wroclaw for Geosystems Polska sp. z o.o. Both Leica ADS40 and Leica ALS50 were used during the flight. All processing steps using the Leica Photogrammetry Suite (LPS) software environment are shortly presented. There are also a few examples of the final products, i.e. orthophotos, various Digital Elevation Models. The project involving simultaneous use of both Leica ADS40 and Leica ALS50 cameras was the first such undertaking in Poland.
Źródło:
Archiwum Fotogrametrii, Kartografii i Teledetekcji; 2006, 16; 41-51
2083-2214
2391-9477
Pojawia się w:
Archiwum Fotogrametrii, Kartografii i Teledetekcji
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Ocena wpływu rozdzielczości i metody pozyskiwania danych wysokościowych na dokładność numerycznych modeli terenu oraz modeli spadków i ekspozycji
Estimation of resolution influence and methods of acquiring high-altitude data on the accuracy of numeric terrain models and models of slopes and aspects
Autorzy:
Burdziej, J.
Kunz, M.
Powiązania:
https://bibliotekanauki.pl/articles/130878.pdf
Data publikacji:
2006
Wydawca:
Stowarzyszenie Geodetów Polskich
Tematy:
NMT
LIDAR
SRTM
rozdzielczość
ekspozycja
spadek terenu
DTM
digital terrain model (DTM)
lidar
resolution
aspect
slope
Opis:
Jednym z podstawowych i najbardziej rozpowszechnionych źródeł danych o ukształtowaniu terenu są numeryczne modele terenu (NMT). Numeryczne modele terenu są jedynie modelami rzeczywistości, a nie jej idealnym odwzorowaniem. Nieodłącznym elementem modeli terenu, podobnie jak wszystkich innych zbiorów danych przestrzennych są błędy, którymi obarczone są te dane. Istotny wpływ na dokładność NMT ma metoda pozyskiwania danych wysokościowych. Do najpowszechniej wykorzystywanych należą: metoda fotogrametryczna, poziomicowa, laserowa (LiDAR) oraz interferometryczna (InSAR). Każda z nich w odmienny sposób przekształca dane, wykorzystując różne algorytmy. Dodatkowym źródłem błędów w modelach terenu wykorzystujących zapis rastrowy jest wielkość najmniejszego pola, dla którego zapisana została określona wartość wysokości. Rozdzielczość modeli rastrowych jest jedną z głównych cech determinujących dokładność odwzorowania terenu. Celem niniejszej pracy było dokonanie oceny dokładności wybranych modeli terenu pod kątem ich przydatności w badaniach środowiska geograficznego. Analiza ta posłużyła do wykazania wpływu rozdzielczości i metod pozyskiwania danych do NMT na dokładność samego modelu terenu, jak również na obliczane na jego podstawie spadki terenu i ekspozycje. Porównane zostały modele pozyskane czterema wymienionymi wcześniej metodami. Do porównania przyjęto ponadto następujące wielkości pikseli (oczek rastra): 1, 5, 10, 25, 50 i 100 m. Największa rozdzielczość (1 m), zbliżona jest do rzeczywistej dokładności pomiarów laserowych. Najmniejsza natomiast (100 m) odpowiada w przybliżeniu rozdzielczości modelu SRTM. Taki wachlarz analizowanych rozdzielczości pozwala dosyć „płynnie” prześledzić, w jaki sposób zmienia się wielkość i charakter błędów w poszczególnych modelach. Badania zostały przeprowadzone na wybranym fragmencie 2×2 km doliny Wisły pod Toruniem.
Digital terrain models (DTM) have become one of the basic and most commonly used sources of data describing the shape of the Earth. Numeric terrain models are only reality models, not the ideal projections. Inseparable elements of terrain models, like in all other groups of spatial data, are mistakes, which exist in the data. There are different methods of acquiring DTM that contribute errors. Some of the most popular methods are: photogrammetric measurements, contour lines, laser scanning (LIDAR), and interferometric (InSAR). Each of them changes data in some other way, using various algorithms. An additional source of mistakes in terrain models using the raster format is the size of the smallest field for which the specified altitude has been defined. The raster model resolution is one of the main features determining the accuracy of terrain projection. The aim of this study was to evaluate the accuracy of chosen terrain models to their application in environment geography studies. This analysis has been used to show the influence of resolution and models of data acquisition for NTM on the accuracy of the terrain model itself, and also on terrain slopes and expositions calculated on its basis. Created models used for the above-mentioned methods were compared. Moreover, the following raster pixels sizes were used for this comparison: 1, 5, 10, 25, 50 and 100 m. The maximal resolution (1 m), is close to the real accuracy of laser measurements. The minimal resolution (100 m) is close to the resolution of the SRTM model. Such a variation of analyzed resolutions makes it possible to observe quite “fluently” how the size and character of mistakes change in separate models. The study area is a 2×2 km test polygon covering part of the Vistula river and its valley and is located near Torun, Poland. The obtained results show the method of collecting data has an essential influence on the accuracy of DTM, especially for high resolution models. Along with a decrease in resolution, differences between models created using separate methods also decrease. For slope models, the collected results show that models with the biggest possible resolution should be used, not smaller than 10 meters. The most essential errors in the definition of aspect are connected with areas with the smallest slopes and are relatively flat.
Źródło:
Archiwum Fotogrametrii, Kartografii i Teledetekcji; 2006, 16; 111-123
2083-2214
2391-9477
Pojawia się w:
Archiwum Fotogrametrii, Kartografii i Teledetekcji
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wykorzystanie danych lotniczego skaningu laserowego jako osnowy geometrycznej dla korekcji obrazów QuickBird
Use of airborne laser scanning data as the geometric control for correcting QuickBird images
Autorzy:
Wolniewicz, W.
Zaremba, M.
Powiązania:
https://bibliotekanauki.pl/articles/131022.pdf
Data publikacji:
2006
Wydawca:
Stowarzyszenie Geodetów Polskich
Tematy:
fotogrametria satelitarna
QuickBird
LIDAR
GPS
model korekcyjny
satellite photogrammetry
lidar
correction model
Opis:
W pracy przedstawiono analizy przydatności techniki LIDAR do ortorektyfikacji zobrazowań QuickBird bez wykorzystania terenowego pomiaru fotopunktów, dla obszaru miasta Ottawa w Kanadzie i terenów leśnych w Prowincji Alberta. Korekcję geometryczną obrazów QuickBird wykonano metodą wielomianową RPF z wykorzystaniem RPC i metody ścisłej. Przedstawiono właściwości modeli korekcyjnych. Do oceny dokładności generowania ortofotomapy wykorzystywano zarówno NMT jak i NMPT pochodzący z danych uzyskanych ze skaningu laserowego. Do ortorektyfikacji oraz oceny dokładności wykorzystano środowisko PCI Ortho Engine. Uzyskano błędy ortorektyfikacji i poziomie 2-3 pikseli dla obszaru miejskiego a na poziomie jednego piksela dla terenów leśnych. Przedmiotem badania był również wpływ liczby fotopunktów na dokładność procesu ortorektyfikacji. Dokładność powstałej ortofotomapy satelitarnej oceniono na podstawie pomiarów GPS. Otrzymane wyniki potwierdzają znaczenie danych pochodzących z wielu źródeł monitorowania powierzchni Ziemi, które coraz powszechniej są wykorzystywane wróżnorodnych zastosowaniach geoinformatycznych. Wykazano praktycznie, iż dane pochodzące ze skaningu laserowego mogą być dobrym źródłem osnowy fotogrametrycznej do korekcji wysokorozdzielczych zobrazowań satelitarnych.
This paper outlines the results of an analysis of the application of LIDAR technology for orthorectification of QuickBird images without using ground control points for the area of the city of Ottawa in Canada as well as for boreal forest areas in the province of Alberta. Geometrical adjustment of QuickBird images was executed using the RPF multinomial method with the use of RPC and the application of the co-linearity condition method. The effects of adjustment models are described in the paper. In order to evaluate the accuracy of the ortho-photo map generation process, both DCM and DSM obtained from laser scanning data were used. The PCI Ortho Engine environment was used as a tool for ortho-adjustment and the evaluation of accuracy. Errors obtained in the ortho-adjustment process were of the order of 2-3 pixels for municipal areas and 1 pixel for forest areas. The influence of a number of ground control points upon the accuracy of ortho-adjustment process was also investigated. The accuracy of the final satellite ortho-photo map was evaluated by applying GSP surveys. The obtained results show the importance of data coming from different Earth monitoring sources, which are used more and more extensively in a variety of different geometric applications. Since VHRR and LIDAR became operational there has been increasing consumer demand for both elevation models and images. As all data is digital from the beginning, data processing is done relatively quickly and is highly automated (mainly only quality control needs operator support), it was demonstrated in practice that the data from laser scanning may constitute an excellent source of photogrammetrical control for the adjustment of very high resolution satellite images. The spectrum of application for precise elevation data and orthophotomaps is much greater than shown here and includes such applications as power line mapping, precision forest management, and open-pit monitoring.
Źródło:
Archiwum Fotogrametrii, Kartografii i Teledetekcji; 2006, 16; 567-575
2083-2214
2391-9477
Pojawia się w:
Archiwum Fotogrametrii, Kartografii i Teledetekcji
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Lotnicze skanowanie laserowe Krakowa
Airborne laser scanning of Cracow
Autorzy:
Jędrychowski, I.
Powiązania:
https://bibliotekanauki.pl/articles/131155.pdf
Data publikacji:
2007
Wydawca:
Stowarzyszenie Geodetów Polskich
Tematy:
lotnicze skanowanie laserowe
LIDAR
ALS
airborne laser scanning (ALS)
lidar
Opis:
Pozyskanie informacji wysokościowej o istniejących elementach pokrycia terenu, a także o samym terenie jest obecnie czymś oczywistym. Dane te są wręcz niezbędne do właściwego wypełniania zadań samorządu, szczególnie w planowaniu przestrzennym i architekturze, a także w wielu innych dziedzinach. Wiele miast zdecydowało sie na tworzenie trójwymiarowych modeli. Wybrane technologie są różne. W Warszawie wskazano na tworzenie trójwymiarowego modelu miasta na podstawie zdjęć lotniczych. Biuro Planowania Przestrzennego Urzędu Miasta Krakowa zdecydowało sie pozyskać informacje wysokościowe za pomocą lotniczego skanowania laserowego (znanego pod nazwa LIDAR lub ALS). Referat przybliży efekty lotniczego skanowania laserowego Krakowa.
Nowadays, gathering information about existing element’s heights and the terrain itself is obvious. This data is essential to perform a number of tasks dealt with by the public administration, especially in the spatial planning, architecture and other fields. Many cities have decided to create spatial models (3D). The techniques of choice vary from one place to another. In Warsaw, urban spatial model is composed of aerial photographs. The Spatial Planning Office Municipality of Krakow decided to gather spatial information by airborne scanning (called LIDAR or ASL). This lecture gives an overview of airborne scanning of Krakow.
Źródło:
Archiwum Fotogrametrii, Kartografii i Teledetekcji; 2007, 17a; 339-345
2083-2214
2391-9477
Pojawia się w:
Archiwum Fotogrametrii, Kartografii i Teledetekcji
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Seasonal and spatial variability of surface seawater fluorescence properties in the Baltic and Nordic Seas: results of lidar experiments
Autorzy:
Drozdowska, V.
Powiązania:
https://bibliotekanauki.pl/articles/47809.pdf
Data publikacji:
2007
Wydawca:
Polska Akademia Nauk. Instytut Oceanologii PAN
Tematy:
chlorophyll a
fluorescence
spatial variability
blossoming period
sea water
seasonal variation
Baltic Sea
lidar
Nordic Sea
Opis:
The paper analyses experimental measurements of laser-induced fluorescence (LIF) spectra in different seawaters. The fluorescence parameters, calculated from LIF spectra as the ratio of the integrals of fluorescence and Raman signal intensities, provide information about the relative changes in the concentrations of fluorescing molecules. Gathered during several cruises in 1994–2004 in the Baltic and Nordic Seas, all the data are presented as scatter plots of the fluorescence parameters of chlorophyll a (Chl a) and coloured dissolved organic matter (CDOM). Satisfactory correlations between these two parameters were found a) for open Nordic Seas waters, b) for the southern Baltic in blooming periods only, and c) for the Gulf of Gdańsk in non-blooming periods only.
Źródło:
Oceanologia; 2007, 49, 1
0078-3234
Pojawia się w:
Oceanologia
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
LIDAR w leśnictwie
LIDAR in forestry
Autorzy:
Zawiła-Niedźwiecki, T.
Stereńczak, K.
Bałazy, R.
Wencel, A.
Strzeliński, P.
Zasada, M.
Powiązania:
https://bibliotekanauki.pl/articles/132231.pdf
Data publikacji:
2008
Wydawca:
Polskie Towarzystwo Geograficzne
Tematy:
leśnictwo
LIDAR
skaning lotniczy
skaning terenowy
forestry
airborne scanning
terrestrial scanning
Źródło:
Teledetekcja Środowiska; 2008, 39; 59-66
1644-6380
Pojawia się w:
Teledetekcja Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Przetwarzanie lotniczych danych lidarowych dla potrzeb generowania NMT i NMPT
Airborne lidar data processing for digital surface model and digital terrain model generation
Autorzy:
Hejmanowska, B.
Borowiec, N.
Badurska, M.
Powiązania:
https://bibliotekanauki.pl/articles/130018.pdf
Data publikacji:
2008
Wydawca:
Stowarzyszenie Geodetów Polskich
Tematy:
LIDAR
NMT
NMPT
lidar
DSM
DTM
Opis:
Przedmiotem prezentowanych analiz było testowanie metodyki przetwarzania lotniczych danych lidarowych dla potrzeb tworzenia numerycznego modelu terenu (NMT) i numerycznego modelu powierzchni terenu (NMPT). Testowanie przeprowadzono w oparciu o dane lidarowe udostępnione przez instytut badawczy UE. Obszar testowy obejmował okolice Ispry we Włoszech. Do badań wykorzystano oprogramowanie Terrasolid (TerraScan, TerraModeler) oraz Geomedia. Testowano metodykę przetwarzania danych lidarowych i badano dokładność wewnętrzną i zewnętrzną NMT. Optymalna długość trójkąta w TerrScan wynosiła 45 m. Wewnętrzną dokładność NMT (porównanie siatki NMT z danymi pomiarowymi z lidara) oszacowano w zakresie: 10-30 cm. Porównanie NMT z pomiarem GPS wykazało błąd systematyczny 50 cm, a odchylenie standardowe 20-30 cm. W artykule zostały zamieszczone wyniki badań prowadzonych w ramach projektu UE, JRC. Natomiast niniejsza publikacja została przygotowana w ramach projektu AGH nr: 11.11.150.949.
The analysis was aimed at testing of aerial lidar data for Digital Terrain Model (DTM) and Digital Surface Model (DSM) generation. Lidar data wereobtained from The JRC , an EU research institute. The test area was located near Ispra, Italy. There were 5 test areas: 3 of them covered a flat JRC region and 2 covered the urban, modulated surface of Ispra near the lake. The TerraScan and Geomedia software packages were applied for data processing. Lidar data processing algorithms and DTM inner and external accuracy were tested. In the ground point classification using the Terrasolid, the triangle length and interaction angle were tested. The optimal triangle length in the TerraScan was found to amount to 45 m. The first phase involved generation of a DTM; subsequently, a DSM was developed basedon lidar cloud point classification (low, middle and high vegetation, and buildings). The accuracy analysis was performed using a DTM with 0.1 m and 1 m pixel size. The resolution of 0.1 m was chosen to render the DTM as comparable as possible to the density of lidar points. However ,resolution of 1 m was also tested because of its usual application in DTM generation from lidar data. Two kinds of accuracy were tested. We called them the inner (comparison of DTM and lidar data) and the external (comparison of DTM and GPS RTK) accuracy. The inner DTM accuracy was estimated at 10-30 cm. The DTM and GPS comparison allowed to determine the systematic error of 20-30 cm and standard deviation of 50 cm. The accuracy (inner and external) obtained was lower than expected. The future research should explain these phenomena. The work was supported by the AGH project No. 11.11.150.949
Źródło:
Archiwum Fotogrametrii, Kartografii i Teledetekcji; 2008, 18a; 151-161
2083-2214
2391-9477
Pojawia się w:
Archiwum Fotogrametrii, Kartografii i Teledetekcji
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Remote sensing applications - new vistas for measurement and control
Autorzy:
Zaremba, M.
Powiązania:
https://bibliotekanauki.pl/articles/384259.pdf
Data publikacji:
2008
Wydawca:
Sieć Badawcza Łukasiewicz - Przemysłowy Instytut Automatyki i Pomiarów
Tematy:
remote sensing
satellite imagery
lidar
image processing
data fusion
distributed control
modeling and simulation
Opis:
The field of remote sensing is an area of science and technology that has undergone rapid development in recent years. This paper focuses primarily on how to exploit the capabilities made available by remote sensing and how to put them to use by combining them with a sys-temic approach to design and analysis in various measurement and control applications. The emphasis is placed on high-resolution satellite and Lidar sensors – the most prevalent remote sensing technologies. Following the presentation of some general issues related to low- and high-level processing of remote sensing data, such as data dimensionality reduction, data fusion, and change detection, the paper provides examples of control-related applications of remote sensing technologies. It is argued that successful exploitation of new generations of remote sensing technologies will require extensive development of new algorithms based on a variety of approaches, such as machine vision, statistical learning, and artificial intelligence.
Źródło:
Journal of Automation Mobile Robotics and Intelligent Systems; 2008, 2, 3; 3-12
1897-8649
2080-2145
Pojawia się w:
Journal of Automation Mobile Robotics and Intelligent Systems
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analiza zasięgowa i badania laboratoryjne prędkościomierza laserowego
Analysis of maximum measurement range and laboratory research of laser velocimeter
Autorzy:
Zygmunt, M.
Muzal, M.
Młodzianko, A.
Knysak, P.
Gietka, A.
Piotrowski, W.
Powiązania:
https://bibliotekanauki.pl/articles/208571.pdf
Data publikacji:
2009
Wydawca:
Wojskowa Akademia Techniczna im. Jarosława Dąbrowskiego
Tematy:
prędkościomierz laserowy
pomiar prędkości
analiza zasięgowa
technika laserowa
laser speedometer
speed measurement
range analysis
police lidar gun
laser technology
Opis:
W artykule przedstawiono zagadnienia związane z wykorzystaniem promieniowania laserowego do pomiaru prędkości pojazdów. Omówiono sposób pomiaru przyjęty w konstrukcji opracowanego w Instytucie Optoelektroniki Wojskowej Akademii Technicznej prototypu prędkościomierza laserowego oraz przedstawiono wyniki analizy zasięgowej z uwzględnieniem podstawowych parametrów zastosowanych w nim elementów optoelektronicznych. Przeanalizowano problem zwiększenia precyzji pomiaru odległości dzięki wykorzystaniu charakterystyk kształtu sygnału echa. Ponadto zaprezentowano wyniki badań prowadzonych w trakcie opracowania modelu laboratoryjnego oraz badań testowych prototypu.
The article presents basic issues concerning the use of laser radiation in remote measurements of vehicles velocity. It shows measurement principles of the prototype lidar system designed and built at the Military University of Technology, and presents analysis of the maximum range of measurement with consideration to prototype technical specifications. It introduces issues and problems with increasing measurement accuracy using geometrical aspects of the echo signal. Moreover, results of the experiments taken during construction of a prototype, as well as results from the examination of finished prototype are presented.
Źródło:
Biuletyn Wojskowej Akademii Technicznej; 2009, 58, 1; 177-191
1234-5865
Pojawia się w:
Biuletyn Wojskowej Akademii Technicznej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Badania charakterystyk rozproszeniowych wybranych układów aerodyspersyjnych
Analyses of scattering characteristics of chosen aerodispersive systems
Autorzy:
Szopa, M.
Mierczyk, Z.
Zygmunt, M.
Powiązania:
https://bibliotekanauki.pl/articles/208502.pdf
Data publikacji:
2009
Wydawca:
Wojskowa Akademia Techniczna im. Jarosława Dąbrowskiego
Tematy:
rozpraszanie promieniowania
układy aerodyspersyjne
aerozole naturalne
aerozole
light scattering
natural aerosols
anthropogenic aerosols
lidar
Opis:
W artykule przeprowadzono analizę teoretyczną charakterystyk rozproszeniowych wybranych układów aerodyspersyjnych, z uwzględnieniem modelu rozpraszania promieniowania elektromagnetycznego na cząstkach sferycznych oraz niesferycznych. Omówione zostały podstawowe charakterystyki aerozoli naturalnych i sztucznych. Dla wybranych układów aerodyspersyjnych przedstawiono wyniki analiz rozproszeniowych. Wyniki analiz porównane zostały z wynikami badań przeprowadzonymi z zastosowaniem dwubarwnego LIDARA rozproszeniowego, opracowanego w Instytucie Optoelektroniki Wojskowej Akademii Technicznej.
In the article, theoretical analyses of a scattering profile of chosen aerosols were made. For these analyses both a model of scattering from spherical particles and nonspherical particles was used. One discussed natural and anthropogenic aerosols, and results of analyses of chosen aerosols were presented. The obtained theoretical results were compared to the results of research with the use of two-wavelength backscattering LIDAR worked out at the Institute of Optoelectronics of the Military University of Technology.
Źródło:
Biuletyn Wojskowej Akademii Technicznej; 2009, 58, 1; 48-67
1234-5865
Pojawia się w:
Biuletyn Wojskowej Akademii Technicznej
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies