Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "LCL filter" wg kryterium: Temat


Wyświetlanie 1-5 z 5
Tytuł:
Research on interaction of APFs based on relative gain array
Autorzy:
Feng, X.
Sun, T.
Ma, W.
Powiązania:
https://bibliotekanauki.pl/articles/141523.pdf
Data publikacji:
2018
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
interaction effect
relative gain array
active power filter
Norton equivalent
LCL filter
Opis:
Different APFs (Active Power Filter) interact with each other when multiple APFs are connected to the grid, and the interactions deteriorate the control performance of APFs and even lead to system instability. This paper presents a method to analyze the dynamic interaction of multiple APFs in a weak grid. This method uses the Norton equivalent principle to establish the mathematical model of a single APF. The mathematical model of the multiple APFs connected to the grid is set up based on the single APF mode. The RGA (Relative Gain Array) principle is used to analyze the interactions among multiple APFs. Besides, this paper analyzes the effect of changing circuit parameters and controller parameters on the change of the interactions. The strategy of weakening and eliminating the interaction is proposed based on rational selection and combination of parameters. Analysis, along with time domain simulation and experimental results, is presented to verify the feasibility and effectiveness of the proposed method and strategy.
Źródło:
Archives of Electrical Engineering; 2018, 67, 1; 165-177
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Efficiency comparison between the LLCL and LCL-filters based single-phase grid-tied inverters
Autorzy:
Wu, W.
Huang, M.
Blaabjerg, F.
Powiązania:
https://bibliotekanauki.pl/articles/140537.pdf
Data publikacji:
2014
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
LCL filter
LLCL-filter
efficiency power loss
modulation
single-phase grid-tied inverter
Opis:
An LLCL-filter is becoming more attractive than an LCL-filter as the interface between the grid-tied inverter and the grid due to possibility of reducing the copper and the magnetic materials. The efficiency of the LLCL-filter based single-phase grid-tied inverter also excites interests for many applications. The operation of the switches of the VSI is various with different modulation methods, which lead to different efficiencies for such a single-phase grid-tied inverter system, and therefore important research has been carried out on the effect of the choice of PWM schemes. Then power losses and efficiencies of the LLCL-filter and the LCL-filter based single-phase grid-tied inverters are analyzed and compared under the discontinuous unipolar, the dual-buck and the bipolar modulations. Results show that the efficiency of LLCL-filter based inverter system is higher than the LCL- filter based independent on the modulation method adopted. Experiments on a 2 kW prototype are in good agreement with results of the theoretical analysis.
Źródło:
Archives of Electrical Engineering; 2014, 63, 1; 63-79
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Properties of active rectifier with LCL filter in the selection process of the weighting factors in finite control set-MPC
Autorzy:
Falkowski, P.
Sikorski, A.
Kulikowski, K.
Korzeniewski, M.
Powiązania:
https://bibliotekanauki.pl/articles/200718.pdf
Data publikacji:
2020
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
model predictive control (MPC)
active front end converters
inductive-capacitive-inductive (LCL) filter
weighting factors selection
Opis:
One of the main problems of multivariable cost functions in model predictive control is the choice of weighting factors. Two finite control set model predictive control algorithms, applied to the three-phase active rectifier with an LCL filter, are described in the paper. The investigated algorithms, i.e. PCicuc and PCigicuc, implement multivariable approaches applying line (grid) current, capacitor voltage and converter current. The main problem dealt with in the paper is the choice of optimum values of the cost function weighting factors. The values of the factors calculated using the method proposed in the paper are very close to the values represented by the lowest THDi of the line current. Moreover, simulations verifying the equations used in the prediction of controlled values, i.e. line current, capacitor voltage and converter current, are presented. Both simulation and experimental results are presented to verify effectiveness of the investigated control strategies under change of the load (P = 5 kW and 2.5 kW), during transient states, under unbalanced and balanced line voltage.
Źródło:
Bulletin of the Polish Academy of Sciences. Technical Sciences; 2020, 68, 1; 51-60
0239-7528
Pojawia się w:
Bulletin of the Polish Academy of Sciences. Technical Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Finite control set MPC of LCL-filtered grid-connected power converter operating under grid distortions
Autorzy:
Falkowski, P.
Godlewska, A.
Powiązania:
https://bibliotekanauki.pl/articles/201460.pdf
Data publikacji:
2020
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
finite control set model predictive control FCS-MPC
grid-connected converters (GCCs)
inductive-capacitive-inductive (LCL) filter
unbalanced grid
higher harmonics
Opis:
Most of the basic control methods of the grid-connected converter (GCC) are defined to work with a sine wave grid voltage. In that case if the grid voltage is distorted by higher harmonics, the grid current may be distorted too, which, in consequence, may increase the value of the THD of the grid voltage. The paper deals with an improved finite control set model predictive control (FCS-MPC) method of an LCL-filtered GCC operating under distorted grid conditions. The proposed method utilizes supplementary grid current feedback to calculate the reference converter current. The introduced signal allows to effectively improve the operation when the grid is subject to harmonic distortion. The paper shows a simulation analysis of the proposed control scheme operating with and without additional feedback under grid distortions. To validate the practical feasibility of the proposed method an algorithm was implemented on a 32-bit microcontroller STM32F7 with a floating point unit to control a 10 kW GCC. The laboratory test setup provided experimental results showing properties of the introduced control scheme.
Źródło:
Bulletin of the Polish Academy of Sciences. Technical Sciences; 2020, 68, 5; 1069-1076
0239-7528
Pojawia się w:
Bulletin of the Polish Academy of Sciences. Technical Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Investigation of a High-efficiency and High-frequency 10-kW/800-V Three-phase PWM Converter with Direct Power Factor Control
Autorzy:
Barlik, Roman
Grzejszczak, Piotr
Leszczyński, Bernard
Szymczak, Marek
Powiązania:
https://bibliotekanauki.pl/articles/226672.pdf
Data publikacji:
2019
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
three-phase PWM rectifier
reactive power compensator
silicon carbide MOSFET
bidirectional power flow
direct power control (DPC)
DC voltage regulation
power factor correction (PFC)
LCL filter
Opis:
The paper presents a concept of a control system for a high-frequency three-phase PWM grid-tied converter (3x400 V / 50 Hz) that performs functions of a 10-kW DC power supply with voltage range of 600÷800 V and of a reactive power compensator. Simulation tests (in PLECS) allowed proper selection of semiconductor switches between fast IGBTs and silicon carbide MOSFETs. As the main criterion minimum amount of power losses in semiconductor devices was adopted. Switching frequency of at least 40 kHz was used with the aim of minimizing size of passive filters (chokes, capacitors) both on the AC side and on the DC side. Simulation results have been confirmed in experimental studies of the PWM converter, the power factor of which (inductive and capacitive) could be regulated in range from 0.7 to 1.0 with THDi of line currents below 5% and energy efficiency of approximately 98.5%. The control system was implemented in Texas Instruments TMS320F28377S microcontroller.
Źródło:
International Journal of Electronics and Telecommunications; 2019, 65, 4; 619-624
2300-1933
Pojawia się w:
International Journal of Electronics and Telecommunications
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-5 z 5

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies