Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "Knee" wg kryterium: Temat


Tytuł:
Computer Aided Design and Structural Analysis of the Endoprosthesis of the Knee Joint
Autorzy:
Zubrzycki, J.
Karpiński, R.
Górniak, B.
Powiązania:
https://bibliotekanauki.pl/articles/118225.pdf
Data publikacji:
2016
Wydawca:
Polskie Towarzystwo Promocji Wiedzy
Tematy:
knee joint
endoprosthesis
finite elements analysis
Opis:
The paper presents results of the preliminary structural analysis of model of the endoprosthesis of the knee joint. Basics of anatomy and biomechanics of the knee joint were introduced. Based on data from computed tomography, the model of knee joint was constructed. The prototype of the endoprosthesis of the knee joint was designed. After determining physical properties of structural materials, the Finite Elements Analysis of the model was conducted under various load conditions. Finally the results of analysis are presented.
Źródło:
Applied Computer Science; 2016, 12, 2; 84-95
1895-3735
Pojawia się w:
Applied Computer Science
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Study on the Influence of Elastic Compression Pants Elasticity and Movement Speed on Human Joint Protection
Autorzy:
Zhang, Ningfeng
Liu, Chengxia
Powiązania:
https://bibliotekanauki.pl/articles/2200750.pdf
Data publikacji:
2022
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Biopolimerów i Włókien Chemicznych
Tematy:
fabric
movement speed
protective performance
knee joint
3D motion capture
Opis:
The aim of this study was to clarify how human movement speed and pants elasticity affect the athletic performance of knee joint protection by testing pants with different elastic properties: CP1 (tight pants) and CP2&CP3 (elastic compression pants), which reinforce the knee joint. In addition, CS (cotton sport pants) was developed as a control garment. Three subjects wore CP1, CP2, CP3 and CS while running on the treadmill at three kinds of human movement speed. A three-dimensional motion capture instrument was used to capture the three-dimensional trajectory of the marked points of lower limbs. As a result, the influence of the movement speed on the kinematic parameters (AKJ & gait cycle) was more obvious than the fabric elasticity. If elastic pants are worn during running, the change of AKJ will be stable with the increase of speed. When non-elastic pants are worn, the effect is opposite. Not only that, elastic compression pants are efficient in reducing the motion amplitude of the knee joint during the suspension period as far as 41°, making it highly practical in terms of stability. That is, the elastic fabric can protect the joints when the lower limbs are in motion. Moreover, with the increase of speed and elasticity, the elastic pants can reduce the gait cycle by up to 22% compared with non-elastic pants alone. Through the kinematics mechanism of human joints, these findings may translate into an effect on protective performance and a reduction in sport injuries. Therefore, it is necessary to wear elastic pants, especially compression pants, when running at higher speed, as the average gait cycle gradually decreases. This research shows that the knee joint protection functions of elastic compression garments differ according to the level of elasticity and differential movement speed, providing theoretical support for designing and producing elastic compression pants. It also acts as a guide for the research of lower limb joint protection.
Źródło:
Fibres & Textiles in Eastern Europe; 2022, 6 (151); 80--90
1230-3666
2300-7354
Pojawia się w:
Fibres & Textiles in Eastern Europe
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The effectiveness of deep transverse friction massage for the treatment of medial meniscotibial ligament injury in a female football player: a case study
Skuteczność głębokiego masażu poprzecznego w leczeniu uszkodzenia więzadła łąkotkowo-piszczelowego przyśrodkowego u zawodniczki piłki nożnej: studium przypadku
Autorzy:
Zaworski, K.
Powiązania:
https://bibliotekanauki.pl/articles/2048964.pdf
Data publikacji:
2020
Wydawca:
Akademia Bialska Nauk Stosowanych im. Jana Pawła II w Białej Podlaskiej
Tematy:
knee joint
massage
ligament
meniscotibial ligament
injury
staw kolanowy
masaż
więzadło
więzadło łąkotkowo-piszczelowe
uraz
Opis:
Background. The injury to medial meniscotibial ligament (MTL) is a cause of pain in the medial articulatio genus which is rarely discussed in the literature. The paper examines the effectiveness of deep transverse friction massage (DTFM) in the treatment of injury to the medial meniscus-tibial ligament in a female football player. Material and methods. A case study concerned a patient ( 22 years old) who is a football player on the position of striker. She has been complaining about the pain in the right, medial articulatio genus for five days. Deep transverse friction massage (DTFM) was applied in the treatment. A total of 9 procedures was conducted (3 times a week) throughout three weeks. The first DTFM session lasted 2 minutes and the time was systematically extended during further sessions until it reached 15 minutes. Visual Analogue Scale (VAS), modified Laitinen Pain Questionnaire and countermovement jump test (CMJ) on the dynamometric platform were applied to evaluate the effectiveness of the treatment. Results. Having completed the treatment, a decrease of pain measured by the means of VAS and Laitinen Pain Questionnaire was reported. There was also improvement in limb symmetry index in all phases of the test carried out on the dynamometric platform. Conclusions. The results demonstrate that DTFM may be an effective method of treatment for MTL injuries. Conducting further research on a bigger study group is necessary.
Wprowadzenie. Rzadko opisywaną w literaturze przyczyną bólu strony przyśrodkowej stawu kolanowego jest uszkodzenie więzadła łąkotkowo-piszczelowego przyśrodkowego (MTL). Celem artykułu jest przedstawienie skuteczność głębokiego masażu poprzecznego (GMP) w leczeniu uszkodzenia więzadła łąkotkowo-piszczelowego przyśrodkowego u zawodniczki piłki nożnej. Materiał i metody. Studium przypadku dotyczyło pacjentki (22 lata) będącej zawodniczką piłki nożnej na pozycji napastniczki. Od pięciu dni skarżyła się na ból przyśrodkowej strony stawu kolanowego prawego. W leczeniu wykorzystano głęboki masaż poprzeczny (GMP). Łącznie wykonano 9 zabiegów (3 razy w tygodniu) przez okres trzech tygodni. Czas GMP w trakcie pierwszej sesji wynosił 2 minuty i był systematycznie wydłużany w trakcie kolejnych spotkań do 15 min. Do oceny skuteczności zastosowanej metody wykorzystano skalę VAS, zmodyfikowany kwestionariusz Laitinena oraz test skoku pionowego (CMJ) na platformie dynamometrycznej. Wyniki. Po zakończeniu leczenia odnotowano spadek dolegliwości bólowych mierzony za pomocą VAS i kwestionariusza Laitinena oraz poprawę wskaźnika symetryczności we wszystkich fazach testu przeprowadzonego na platformie dynamometrycznej. Wnioski. Uzyskane wyniki w badaniach własnych wskazują, że GMP może być skuteczną metodą leczenia uszkodzeń MTL. Istnieje potrzeba prowadzenia dalszych badań na większej grupie badanej.
Źródło:
Health Problems of Civilization; 2020, 14, 2; 141-147
2353-6942
2354-0265
Pojawia się w:
Health Problems of Civilization
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Bioorteza robotyczna jako skuteczne urządzenie diagnostyczne i wspomagające rehabilitację
Autorzy:
Wysocki, M.
Stachurski, R.
Dzwończyk, S.
Powiązania:
https://bibliotekanauki.pl/articles/2063829.pdf
Data publikacji:
2016
Wydawca:
Międzynarodowe Stowarzyszenie na rzecz Robotyki Medycznej
Tematy:
orteza
urządzenia do rehabiltacji
rehabilitacja stawu kolanowego
orthosis
medical devices for rehabilitation
knee rehabilitation system
Opis:
ExoLimbs umożliwia optymalizację i zintensyfikowanie procesu usprawniania, skrócenie rekonwalescencji i zmniejszenie niepełnosprawności oraz zmniejszenie kosztów leczenia. Bioorteza kończyny dolnej wykorzystuje aktualne możliwości monitorowania i mechanicznego wspomagania pracy stawów z jednoczesną elektrodiagnostyką i stymulacją pracy mięśni. Jest to urządzenie o bardzo szerokim zastosowaniu w traumatologii, neurologii a przede wszystkim w fizjoterapii i rehabilitacji. Zapewnia pełne bezpieczeństwo terapii przy stałym kontakcie online z fizjoterapeutą. Jest urządzeniem stabilizującym, diagnostycznym oraz mobilnym robotem rehabilitacyjnym, szeroko dostępnym umożliwiającym dostęp do nowoczesnej rehabilitacji kolan. Dodatkowo umożliwia zdalne śledzenie parametrów terapii na ekranie komputera lub urządzenia mobilnego.
ExoLimbs makes it possible to optimize and intensify the recovery process, shorten convalescence and reduce disability, as well as the cost of treatment. Bioorthosis of the lower limb utilizes the current monitoring capabilities and mechanical support of joint operation wit simultaneous electrodiagnostics and stimulation of muscle work. It is a device with a very broad application in traumatology, neurology and above all in physiotherapy and rehabilitation. It provides complete safety of the therapy with regular online contact with a physiotherapist. It is a stabilizing, diagnostic and mobile rehabilitation robot widely accessible for modern knee rehabilitation. Additionally, it enables remote tracking of therapy parameters on the computer screen or mobile device.
Źródło:
Medical Robotics Reports; 2016, 5; 12--16
2299-7407
Pojawia się w:
Medical Robotics Reports
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wspomaganie planowania alloplastyki stawu kolanowego przy pomocy nowoczesnych metod inżynierskich
Supporting of planning total knee replacement with modern engineering methods
Autorzy:
Wojnarowska, Wiktoria
Miechowicz, Sławomir
Powiązania:
https://bibliotekanauki.pl/articles/985955.pdf
Data publikacji:
2019
Wydawca:
Indygo Zahir Media
Tematy:
planowanie zabiegów
alloplastyka
szybkie prototypowanie
rekonstrukcja
inżynieria odwrotna
planning procedures
total knee replacement
rapid prototyping
reconstruction
reverse engineering
Opis:
W pracy zaprezentowano możliwości stosowania nowoczesnych metod inżynierskich w planowaniu zabiegu operacyjnego całkowitej wymiany stawu kolanowego. Został omówiony proces wykonywania wirtualnych i fizycznych modeli stawu kolanowego przy użyciu metod inżynierii odwrotnej. Obiektem wejściowym do realizacji procesu były obrazy DICOM, które pochodziły z badania tomograficznego. Przedstawiono także potencjalne korzyści wynikające z użycia tych technik.
The paper presents the possibility of using modern engineering methods in planning total knee replacement surgery. It was discussed the process of making virtual and physical knee models using methods of reverse engineering. The input object for the process were DICOM images that came from a computed tomography scan. The potential benefits of using these techniques were also presented.
Źródło:
Inżynier i Fizyk Medyczny; 2019, 8, 5; 413-416
2300-1410
Pojawia się w:
Inżynier i Fizyk Medyczny
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Physiotherapeutic management of a patient with patellofemoral pain syndrome – a case report
Autorzy:
Ustarbowska, Katarzyna
Trybulec, Bartosz
Powiązania:
https://bibliotekanauki.pl/articles/454991.pdf
Data publikacji:
2018
Wydawca:
Uniwersytet Rzeszowski. Wydawnictwo Uniwersytetu Rzeszowskiego
Tematy:
patellofemoral pain syndrome excessive lateral pressure syndrome
runner’s knee
physiotherapy
kinesiotaping
Opis:
Introduction. Patellofemoral pain syndrome (PFPS) is a disorder of the front compartment of the knee joint with incompletely investigated, probably multifactorial pathogenesis. It mostly affects young people and runners. In patients with PFPS conservative management is a therapy of choice with fundamental importance of physiotherapeutic procedures. Therapy should be highly individualized and considering all possible factors that may cause PFPS symptoms. Aim. The aim of this report was presentation of management of a 23 year old female patient with PFPS that developed secondary to a knee sprain. The medical history, diagnostic and therapeutic procedures were thoroughly described, then obtained results were presented and thereafter discussed. Methods. Clinical assessment included functional and provocative tests of the patellofemoral joint as well as thigh and calf muscles tests, range of motion measurement of the knee joint and pain assessment using the VAS scale. Therapeutic management included 5 sessions of post-isometric muscle relaxation (PIR), mobilizations of the patella and applications of elastic tapes. Results. After 5 sessions of therapeutic management PFPS symptoms were significantly reduced. Pain did not occur during normal activity, whereas in heavy joint loading, it occurred later and was of lower intensity. Range of motion as well as subjective sense of joint stability was also improved. Conclusions. Individually adjusted conservative management based on PIR techniques, mobilizations of patella and kinesiotaping seems to be effective form of therapy for PFPS of functional nature
Źródło:
European Journal of Clinical and Experimental Medicine; 2018, 1; 68-75
2544-2406
2544-1361
Pojawia się w:
European Journal of Clinical and Experimental Medicine
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Study of CPM device used for rehabilitation and effective pain management following knee alloplasty
Autorzy:
Trochimczuk, R.
Kuźmierowski, T.
Anchimiuk, P.
Powiązania:
https://bibliotekanauki.pl/articles/265585.pdf
Data publikacji:
2017
Wydawca:
Uniwersytet Zielonogórski. Oficyna Wydawnicza
Tematy:
CPM device
rehabilitation robot
effective pain management
knee alloplasty
FEM analysis
robot rehabilitacyjny
leczenie bólu
alloplastyka kolana
Opis:
This paper defines the design assumptions for the construction of an original demonstration of a CPM device, based on which a solid virtual model will be created in a CAD software environment. The overall dimensions and other input parameters for the design were determined for the entire patient population according to an anatomical atlas of human measures. The medical and physiotherapeutic community were also consulted with respect to the proposed engineering solutions. The virtual model of the CPM device that will be created will be used for computer simulations of changes in motion parameters as a function of time, accounting for loads and static states. The results obtained from computer simulation will be used to confirm the correctness of the design adopted assumptions and of the accepted structure of the CPM mechanism, and potentially to introduce necessary corrections. They will also provide a basis for the development of a control strategy for the laboratory prototype and for the selection of the strategy of the patient's rehabilitation in the future. This paper will be supplemented with identification of directions of further research.
Źródło:
International Journal of Applied Mechanics and Engineering; 2017, 22, 1; 241-251
1734-4492
2353-9003
Pojawia się w:
International Journal of Applied Mechanics and Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Evaluating measurement accuracy and repeatability with a new device that records spatial knee movement
Autorzy:
Tian, Fei
Huang, Qiuyue
Zheng, Zhi
Li, Ningwei
Zhu, Ting
Dai, Wei
Wang, Shaobai
Powiązania:
https://bibliotekanauki.pl/articles/27324129.pdf
Data publikacji:
2020
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
gait analysis
repeatability
motion analysis
three-dimensional
knee joint
analiza chodu
powtarzalność
analiza ruchu
trójwymiarowy
staw kolanowy
Opis:
Purpose: A novel portable system has been used to evaluate spatial knee movement, but its accuracy and repeatability is not known. The aim of this study was to investigate the accuracy and repeatability of the measurement. Methods: Ten healthy participants were included, and the knee motion trajectory during walking were assessed. Six evaluations were conducted (three days by two raters) for each participant. The motion parameters at the key points and the range of motion were statistically analyzed. Intraclass correlation coefficients (ICC), standard error of the measurement (SEM), and the Bland–Altman method were used. Results: For intra-rater repeatability, 1) the ICC values range from 0.75 to 0.9 for rotations; and 0.64 to 0.96 for translations. Among the ICC values, 100% of rotations and 90% of translations were not less than 0.70; 2) among the SEM values, 100% of rotations were not more than 5°, while 73.3% of translations were less than 3 mm. For inter-rater repeatability, 1) the ICC values range from 0.68 to 0.99 for rotations; and 0.57 to 0.93 for translations. Among the ICC values, 95.6% of rotations and 82.2% of translations were not less than 0.70; 2) among the SEM values, 100% of rotations were not more than 5°, and 48.9% of translations were less than 3 mm. The Bland–Altman plots showed good agreement for intra- and inter-repeatability. Conclusions: The results indicated that the accuracy and repeatability of the measurement were acceptable, except for the inter-rater repeatability for translation. This may help researchers and physicians better interpret the measurement data.
Źródło:
Acta of Bioengineering and Biomechanics; 2020, 22, 3; 55--67
1509-409X
2450-6303
Pojawia się w:
Acta of Bioengineering and Biomechanics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analiza wytrzymałościowa endoprotezy stawu kolanowego
Strength analysis of total knee prosthesis
Autorzy:
Tejszerska, D
Długoszewski, T.
Gąsiorek, D
Powiązania:
https://bibliotekanauki.pl/articles/99077.pdf
Data publikacji:
2010
Wydawca:
Politechnika Śląska. Katedra Biomechatroniki
Tematy:
analiza wytrzymałościowa
endoproteza
staw kolanowy
ANSYS
strength analysis
endoprosthesis
knee joint
Opis:
W artykule przedstawiono analizę wytrzymałościową endoprotezy stawu kolanowego z wyłączeniem elementu udowego dla kilku wariantów obciążenia. Analiza ta pozwala na obserwację wpływu obciążenia na stan naprężeń i odkształceń w kości i endoprotezie. Model i jego analizę przeprowadzono metodą elementów skończonych w programie Ansys Workbench.
Numerical strength analysis of total knee prosthesis without femur element for few variants of load was presented in this paper. This analysis allow us observe the influence of load on the state of stress and strain in tibia bone and prosthesis . The model and its finite element analysis was performed in ANSYS Workbench.
Źródło:
Aktualne Problemy Biomechaniki; 2010, 4; 213-218
1898-763X
Pojawia się w:
Aktualne Problemy Biomechaniki
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The Incidence of Knee Pain Among Healthy People Engage in Tai Chi and Jogging as Measured by the Western Ontario Osteoarthritis and McMaster Universities Arthritis Index (WOMAC)
Autorzy:
Sutjiadi, Shelly
Haryono, Ignatio Rika
Powiązania:
https://bibliotekanauki.pl/articles/2036809.pdf
Data publikacji:
2020-08-15
Wydawca:
Fundacja Edukacji Medycznej, Promocji Zdrowia, Sztuki i Kultury Ars Medica
Tematy:
Jogging
Knee Pain
Osteoarthritis
OA index
Tai Chi
Opis:
Background. Exercise has been recognized to improve functional limitation and pain in knee osteoarthritis (OA). However, exercise has also been reported to induce exercise-related knee pain. This study aimed to compare the effect of Tai Chi and jogging on knee pain in healthy and related factors. Material and methods. This cross-sectional study involved male and female 180 participants aged 40-60-years. The participant consisted of Tai Chi (n=60), jogging (n= 60), and sedentary (n=60) as control. Weight height and body mass index (BMI) were measured. The pain was evaluated using The Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC). Risk factors of knee OA were included. ANOVA followed with post hoc test, Chi-square, Pearson and Spearman correlation, and logistic regression were applied to compute statistical analysis tests. Results. There are 4 participants (2.5%) with the WOMAC score index at high risk of knee OA. Seventy-six participants (63%) engaged in Tai Chi and jogging had knee pain. The possible risk factors of knee pain, which significantly correlated with knee pain were age, weight, BMI, family history of rheumatoid arthritis, and spine alignment. A linear regression indicated both Tai Chi and jogging did not significant different compared to control (OR 1.23, CI 95% 0.59-2.25, p=0.58 and OR 0.69, CI 95% 0.32-1.47, p=0.34, respectively) Conclusion. The incidence of knee pain in Tai Chi and jogging is quite high. However, the WOMAC score index is mostly normal. Tai Chi tends to aggravate knee pain than jogging in people with risk factors.
Źródło:
Polish Journal of Sports Medicine; 2020, 36(1); 1-6
1232-406X
2084-431X
Pojawia się w:
Polish Journal of Sports Medicine
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Poziom rozwijanego statycznego momentu siły a wysokość skoku CMJ studentów AWF we Wrocławiu
The level of the static moment of force and cmj height of university school of physical education students
Autorzy:
Struzik, A.
Pietraszewski, B.
Powiązania:
https://bibliotekanauki.pl/articles/99255.pdf
Data publikacji:
2010
Wydawca:
Politechnika Śląska. Katedra Biomechatroniki
Tematy:
moment siły
staw kolanowy
własności biomechaniczne
moment of force
knee joint
biomechanical properties
Opis:
W pracy poszukiwano związku między statycznym momentem siły prostowników i zginaczy stawu kolanowego (sumy prostowników i sumy zginaczy) a wysokością skoku CMJ. Rejestracji sił reakcji podłoża dokonano używając platformy dynamometrycznej firmy Kistler i oprogramowania BioWare. Badania przeprowadzono na grupie 30 studentów IV roku AWF we Wrocławiu w Pracowni Analiz Biomechanicznych. Badanymi były osoby uprawiające sport wyczynowo od minimum 5 lat. Badania miały na celu ocenę własności biomechanicznych (mierzonych w działaniach statycznych i dynamicznych) kończyn dolnych człowieka.
The purpose of the research was to determine the relationship between the static moment of force of knee joint flexors and extensors (sum of flexors and sum of extensors) and the height of CMJ jump. Dynamometric Kistler plate and BioWare software were applied to record the ground reaction force. 30 University School of Physical Education students participated in the study. The research was conducted in the Laboratory of Biomechanical Analysis in Wroclaw. Subjects have been performing professional sport no less than 5 years. The purpose of the research was to assess the biomechanical properties of the lower limbs (measured during static and dynamic exercises).
Źródło:
Aktualne Problemy Biomechaniki; 2010, 4; 179-184
1898-763X
Pojawia się w:
Aktualne Problemy Biomechaniki
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Ratios of torques of antagonist muscle groups in female soccer players
Autorzy:
Struzik, A.
Siemieński, A.
Bober, T.
Pietraszewski, B.
Powiązania:
https://bibliotekanauki.pl/articles/307148.pdf
Data publikacji:
2018
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
staw kolanowy
asymetria
ścięgna
asymmetry
knee joint
hamstring-to-quadriceps ratio
Opis:
An increase in the value of the hamstring-to-quadriceps (H/Q) ratio with an increase in angular velocity may effectively prevent injuries of the back of the thigh. Previous studies have found that the conventional H/Q ratio was unaltered along with an increasing angular velocity in females. Therefore, this study aimed to investigate the relationships between the conventional H/Q ratio and angular velocity in a group of female soccer players. Methods: The study was carried out on a group of 16 female soccer players (age: 20.7 ± 3.9 years, body height: 166.1 ± 5.8 cm, body mass: 58.4 ± 6.2 kg, training experience: 8.8 ± 4.1 years). Measurements of peak torque of extensors and flexors of the knee joint under static conditions and under isokinetic conditions (at angular velocities of 30°/s, 60°/s, 90°/s and 120°/s) were carried out using a Biodex dynamometer. Results: There was a statistically significant increase in the conventional H/Q ratio with an increase in angular velocity. These differences occurred between measurements at angular velocities of 0°/s and 30°/s, and 30°/s and 60°/s. Conclusions: As previously found for males, an increase in conventional H/Q ratio with increased angular velocity was also present in this group of female players. This phenomenon should reduce the number of injuries of the muscles of back of the thigh. Coaches should pay attention to increasing the level of strength in the group of knee joint flexor muscles so as to make the value of the H/Q ratio appropriately high and increasing with increasing angular velocity.
Źródło:
Acta of Bioengineering and Biomechanics; 2018, 20, 1; 153-158
1509-409X
2450-6303
Pojawia się w:
Acta of Bioengineering and Biomechanics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analysis of fatigue loads of the knee joint during gait
Autorzy:
Stępniewski, Andrzej
Powiązania:
https://bibliotekanauki.pl/articles/306291.pdf
Data publikacji:
2019
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
staw kolanowy
chód
kości
zmiany strukturalne
knee joint
support phase
gait
accumulation of lesions
structural changes in the bone
Opis:
The aim of the work was to show that the fatigue load of bone tissue causes permanent structural changes in it. Methods: On the basis of the movie recording of gait, the time courses of angular changes in the joints of the lower limb were determined. Using the method of transforming Denavit–Hartenberg coordinate systems, the course of force loading the hip joint and, after that, the course of normal contact reaction of the femoral head of the knee joint during gait for the support phase were determined. On the basis of the Hertz formula, the course of contact stresses in the femoral joint head and the damage coefficient were determined according to the Palmgren–Miner damage accumulation hypothesis. Results: A calculation example was made using own software. The course of the obtained damage factor was compared to the image fixed in the X-ray image after its appropriate processing. The thesis of the work has been confirmed to a satisfactory degree. Conclusions: The nature of the lesions is similar to the image of structural changes in the head of the joint. It should be assumed that the image fixed in the bone is the result of the stored history of loads. Analysis of the obtained image can be used to determine the state of bone strength.
Źródło:
Acta of Bioengineering and Biomechanics; 2019, 21, 3; 159-167
1509-409X
2450-6303
Pojawia się w:
Acta of Bioengineering and Biomechanics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analiza geometryczna i ruchowa stawu kolanowego człowieka
Geometrical and mobility analysis of knee joint of man
Autorzy:
Stępniewski, A. A.
Powiązania:
https://bibliotekanauki.pl/articles/972139.pdf
Data publikacji:
2009
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
analiza strukturalna
analiza kinematyczna
staw kolanowy
structural analysis
kinematical analysis
knee joint
Opis:
W pracy przeprowadzono analizę strukturalną i geometryczno-ruchową płaskiego modelu stawu kolanowego. Wyznaczono ruchliwość i zidentyfikowano więzy bierne. Określono podstawowe wymiary, konieczne do opisania geometrii stawu. Do analizy ruchowej przyjęto uproszczony model płaski. Wykorzystując przekształcenia układów współrzędnych Denavita-Hartenberga, wyznaczono wektory położeń charakterystycznych punktów kości udowej względem kości piszczelowej. Wyznaczono linię styku kości piszczelowej z udową dla pełnego zakresu ruchu w stawie. Opracowano algorytm wyznaczania współrzędnych położenia punktu przytwierdzenia więzadeł pobocznych do kości udowej dla zadanego położenia punktu przytwierdzenia względem kości piszczelowej. Zamieszczono przykład obliczeniowy będący ilustracją omówionego algorytmu.
The paper presents the structural, geometric and mobility analysis of flat mechanism of the knee joint model. The mobility was determined and passive bonds were identified. The basic dimensions, necessary for description of the joint geometry, were defined. The simplified flat model was assumed for the mobility analysis. Using the transformation of Denavit-Hartenberg systems of coordinates, vectors of position of the femoral bone characteristic points in relation to the tibial bone were determined. The shape of the tibial bone pan assuring solid contact of the bone during full range of movement in the joint was defined. There was worked out an algorithm for determining the position coordinates of the point of attaching marginal ligaments to the femoral bone for the given position of the attaching point in relation to the tibial bone. The example of computations illustrating the algorithm discussed is presented in the paper. It can be stated that in the joint flat model there appear three passive fetters: the point of the bone junction, two marginal ligaments along with the kinematic pair. The relative movement along circle of marginal ligaments ends is loaded with the radial error equal to 0,7 mm.
Źródło:
Pomiary Automatyka Kontrola; 2009, R. 55, nr 6, 6; 342-345
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analiza strukturalna, geometryczna i statyczna mechanizmu stawu kolanowego
Analysis of structural, geometrical and static of knee-joint mechanism
Autorzy:
Stępniewski, A.
Powiązania:
https://bibliotekanauki.pl/articles/386350.pdf
Data publikacji:
2010
Wydawca:
Politechnika Białostocka. Oficyna Wydawnicza Politechniki Białostockiej
Tematy:
staw kolanowy
biomechanika
analiza strukturalna
knee joint
biomechanics
structural analysis
Opis:
W pracy przeprowadzono analizę strukturalną, geometryczną i statyczną mechanizmu wzorowanego na budowie stawu kolanowego człowieka. Wyznaczono ruchliwość, zidentyfikowano więzy bierne i sklasyfikowano mechanizm stawu. Określono podstawowe wymiary, konieczne do opisania geometrii stawu. Do analizy przyjęto uproszczony model płaski. Wykorzystując przekształcenia układów współrzędnych Denavita-Hartenberga, wyznaczono wektory położeń charakterystycznych punktów kości udowej i rzepki względem kości piszczelowej. Wyznaczono obciążenia elementów stawu. Zamieszczono przykład obliczeniowy będący ilustracją omówionego algorytmu obliczeniowego.
This article shows structural, geometrical and static analysis of the knee-joint. Mobility was determined and passive bonds were identified. The basic dimensions were defined, neces- sary for description of geometry of joint. Simplified flat model was accepted for mobility analysis. Using the transformation of arrangement co-ordinate Denavit-Hartenberg, vectors of sites characteristic of bones of femoral bone, according to tibial bone were defined. Loads of elements of the pond were set. Computational being example was put illustration of discussed algorithm.
Źródło:
Acta Mechanica et Automatica; 2010, 4, 1; 80-85
1898-4088
2300-5319
Pojawia się w:
Acta Mechanica et Automatica
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies