Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "IMS" wg kryterium: Temat


Wyświetlanie 1-15 z 15
Tytuł:
Intelligent manufacturing systems - automatic speech recognition system
Autorzy:
Gregor, M.
Michulek, T
Powiązania:
https://bibliotekanauki.pl/articles/117839.pdf
Data publikacji:
2009
Wydawca:
Polskie Towarzystwo Promocji Wiedzy
Tematy:
manufacturing processes
IMS
ASR
Opis:
The University of Žilina and the Central European Institute of Competitiveness have been conducting research in development of Intelligent Manufacturing System. One of areas researched was Automatic Speech Recognition (ASR) and control of manufacturing processes through voice control. This paper presents chosen results from research done at the University of Zilina and at the Central European Institute of Technology.
Źródło:
Applied Computer Science; 2009, 5, 1; 55-68
1895-3735
Pojawia się w:
Applied Computer Science
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Contribution of the IMS global network of hydroacoustic stations for monitoring the CTBT
Autorzy:
Bitnner, P.
Jonathan, E.
Villarroel, M.
Powiązania:
https://bibliotekanauki.pl/articles/331513.pdf
Data publikacji:
2008
Wydawca:
Polskie Towarzystwo Akustyczne
Tematy:
CTBT
IMS
hydroacoustics
Opis:
The International Monitoring System (IMS) of the Comprehensive Nuclear-Test-Ban Treaty Organization (CTBTO) Preparatory Commission, in Vienna operates a global network of 321 monitoring stations and 16 radionuclide laboratories that monitors the earth for evidence of nuclear explosions within the atmosphere, underwater and underground. The IMS uses a network of four verification technologies: seismic, hydroacoustic, infrasound and radionuclide. All the data recorded by the IMS network are transmitted to the International Data Centre (IDC) of the CTBTO in Vienna. The data are then received, processed, resulting data and products distributed and archived by the IDC. This study will give an overview of the contribution of the IMS hydroacoustic network and will highlight that for areas not well covered with the seismic network this part of the IMS can be very valuable for detecting events, improving the location obtained from the seismic network and providing information about the nature of sources.
Źródło:
Hydroacoustics; 2008, 11; 19-26
1642-1817
Pojawia się w:
Hydroacoustics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Detection of volatile organic compounds with a differential ion mobility spectrometry
Wykrywanie lotnych związków organicznych za pomocą różnicowej spektrometrii ruchliwości jonów
Autorzy:
Maziejuk, M.
Sikora, T.
Lisowski, W.
Powiązania:
https://bibliotekanauki.pl/articles/258322.pdf
Data publikacji:
2016
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Technologii Eksploatacji - Państwowy Instytut Badawczy
Tematy:
spectrometry
VOCs
IMS
DMS
spektrometria
LZO
Opis:
Recently growing importance of control of indoor air. The requirements for such detectors are very high: a sensitivity of several tens of ppb; the detection of a large number of substances or to indicate the total amount of volatile organic compounds (VOCs), work in high humidity ranges. A very good solution for the determination of the VOCs is to use IMS (Ion Mobility Spectrometers) or DMS (ang. Differential Mobility Spectrometry) technology, which has a relatively low price while meeting the above requirements. The most important difference between classical spectrometer IMS and the DMS is the electric field. For the IMS it is a constant magnetic field of low intensity – around several hundred volts per cm, meanwhile for the DMS it is at least several kilovolts per cm and is a field with a relatively high frequency from 1 up to several MHz. Another area in which the detection of VOC is becoming increasingly important, is early diagnosis of serious diseases of civilization, eg. diabetes, lung or liver disease – the diagnosis can be made based on the analysis of exhaled air, preferably in conjunction with the study of emissions substances from the skin. Issues related to the prevention and early detection of the above mentioned diseases are rapidly developed, eg. in the US or in the UK. Given the scale of the problem and the challenges of a potential diagnostic method, the proposed technology DMS/IMS begins to be considered as possible to apply. Spectrometers of this type are also developed in Poland by WIChiR. Research results on the selected VOCs are showed in this presentation.
Coraz większego znaczenia nabiera kontrola powietrza wewnątrz pomieszczeń. Wymagania na takie detektory są bardzo wysokie: czułość na poziomie kilkudziesięciu ppb; wykrywanie dużej liczby substancji lub wskazywanie sumarycznej ilości lotnych związków organicznych (LZO), praca w wysokich zakresach wilgotności. Bardzo dobrym rozwiązaniem do oznaczania LZO jest zastosowanie technologii IMS (ang. Ion Mobility Spektrometry) i DMS (ang. Differential Mobility Spectrometry), które charakteryzują się relatywnie niską ceną spełniając jednocześnie powyższe wymagania. Najistotniejszą różnicą pomiędzy klasycznym spektrometrem IMS-em, a DMS-em jest pole elektryczne. Dla IMS-a jest to pole stałe o niewielkim natężeniu – kilkaset volt na cm, natomiast dla DMS-a jest to co najmniej kilkanaście kilowoltów na cm, przy czym jest to pole o dość wysokiej częstotliwości od 1 do kilku MHz. Kolejna dziedzina, w której wykrywanie LZO nabiera coraz większego znaczenia to wczesna diagnoza groźnych chorób cywilizacyjnych, np. cukrzyca, choroby płuc czy wątroby – diagnoza ta może być dokonana na podstawie analizy wydychanego powietrza najlepiej w połączeniu z badaniem emisji ze skóry. Zagadnienia związane z zapobieganiem i wczesnym wykrywaniem ww. chorób są bardzo raptownie rozwijane np. w USA i Wielkiej Brytanii. Biorąc pod uwagę skalę problemu oraz wyzwania stawiane potencjalnej metodzie diagnostycznej, proponowana technologia DMS/IMS zaczyna być rozważana jako możliwa do zastosowania. Spektrometry tego typu są opracowane również w Polsce w WIChiR. Wyniki badań dla przykładowych LZO zostały przedstawione w niniejszej prezentacji.
Źródło:
Problemy Eksploatacji; 2016, 2; 173-182
1232-9312
Pojawia się w:
Problemy Eksploatacji
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Design of integrated management systems according to the revised ISO standards
Model zintegrowanych systemów zarządzania według zmienionych standardów ISO
Autorzy:
Majernik, M.
Daneshjo, N.
Chovancova, J.
Sanciova, G.
Powiązania:
https://bibliotekanauki.pl/articles/405346.pdf
Data publikacji:
2017
Wydawca:
Politechnika Częstochowska
Tematy:
management system
integration
standardization
algorithm of implementation
designing IMS
HLS structure
system zarządzania
integracja
standaryzacja
algorytm implementacji
projektowanie IMS
struktura HLS
Opis:
An implementation of international standards in the management systems of organizations is increasingly promoted in non-regulated sector in globalized markets. Authors of the paper present the partial results of the research in the area of projecting and implementation of integrated management systems according to international standards ISO 9001, ISO 14001, OHSAS 18001, ISO 27001 etc. Based on an analysis of the latest standards for management sub-systems with HLS structure implementation, an innovative concept of model for an implementation and maintaining of integrated management systems is introduced. The proposed process algorithm on Deming’s PDCA cycle of the implementation is applicable to any type of organization and economic sector according to the NACE codes and with the respect to newly adopted requirements of ISO standards, e.g. documented information on IMS.
Wdrożenie międzynarodowych standardów w zakresie systemów zarządzania organizacji jest coraz częściej promowane w nieregulowanym sektorze w zglobalizowanych rynkach. Autorzy niniejszego artykułu przedstawiają częściowe wyniki badań w zakresie projektowania i wdrażania zintegrowanych systemów zarządzania zgodnie z międzynarodowymi normami ISO 9001, ISO 14001, OHSAS 18001, ISO 27001 itd. W oparciu o analizę najnowszych standardów dla podsystemów zarządzania z wdrożeniem struktury HLS, wprowadzono innowacyjną koncepcję modelu wdrożenia i utrzymania zintegrowanych systemów zarządzania. Proponowany algorytm procesu w cyklu wdrażania PDCA Deminga, który uwzględnia nowo przyjęte wymagania norm ISO, np. udokumentowane informacje o IMS, ma zastosowanie do każdego rodzaju organizacji i sektora gospodarki według kodów NACE.
Źródło:
Polish Journal of Management Studies; 2017, 15, 1; 135-143
2081-7452
Pojawia się w:
Polish Journal of Management Studies
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Detektory do wykrywania skażeń chemicznych dla bezzałogowej platformy lądowej (strażak)
Detectors For the Detection of Chemical Contaminations for the Unmanned Mobile Platform (Strażak)
Autorzy:
Harmata, W.
Maziejuk, M.
Ceremuga, M.
Powiązania:
https://bibliotekanauki.pl/articles/373700.pdf
Data publikacji:
2014
Wydawca:
Centrum Naukowo-Badawcze Ochrony Przeciwpożarowej im. Józefa Tuliszkowskiego
Tematy:
detekcja
spektrometria ruchliwości jonów
detection
Ion Mobility Spectrometry (IMS)
Opis:
Cel: Celem artykułu jest prezentacja budowy oraz wyników działania detektora do wykrywania skażeń chemicznych zainstalowanego na bezzałogowej platformie lądowej (BPL) „Strażak”, którą zaprezentowano w artykule przeglądowym BiTP Vol. 30, Issue 2, 2013, pp. 81-90. Wprowadzenie: Obecny stan zaawansowania techniki pożarniczej wymaga uwzględnienia w planach realizacji akcji ratowniczogaśniczych starannego rozpoznania zagrożeń, jakie mogą zaistnieć w trakcie wykonywania zadania. Oczywista jest konieczność rozpoznania wynikająca z charakteru gaszonego obiektu. Przygotowując środki do zdławienia pożaru, należy brać pod uwagę te niebezpieczne substancje chemiczne, jakie na danym obiekcie występują oraz ich charakter (bojowe środki trujące, toksyczne środki przemysłowe, materiały wybuchowe, gazy tworzące mieszanki łatwopalne lub samozapalne, źródła promieniotwórcze itp.). Do niedawna PSP nie dysponowała odpowiednim sprzętem, który umożliwiałby zdalną detekcję. Obecnie w dyspozycji CNBOP jest bezzałogowa platforma lądowa pn. „Strażak”, która została wyposażona w odpowiedni detektor monitorujący zagrożenie oraz generujący sygnał alarmowy w momencie wykrycia zagrożenia. Przyrząd taki jest elementem wspomagającym decyzje osób kierujących akcją ratowniczo-gaśniczą. Metodologia: Detekcja zagrożeń realizowana jest za pomocą wieloczujnikowego układu pomiarowego pn. „FireChem”. Układ pomiarowy został zainstalowany jako integralny element BPL „Strażak”. Służy on do detekcji emisji zanieczyszczeń niebezpiecznymi substancjami chemicznymi. Składa on się z trzech modułów: modułu z czujnikami elektrochemicznymi, spektrometru optycznego oraz spektrometru ruchliwości jonów (IMS). Dzięki tak unikalnej budowie układ ten jest w stanie wykrywać substancje chemiczne (toksyczne środki przemysłowe) z niekontrolowanych uwolnień oraz bojowe środki trujące, które mogą się pojawić w przypadku ataku terrorystycznego lub znaleziska. Istotną częścią układu detekcji jest spektrometr optyczny, który służy przede wszystkim do ostrzegania o wejściu w strefę zagrożoną wybuchem. Za jego pomocą można bardzo skutecznie wykrywać węglowodory alifatyczne (metan oraz mieszaninę propanu z butanem). W pracy przedstawiono podstawowe informacje na temat budowy i zasady działania detektora IMS oraz wyniki pomiarów wybranych substancji przez detektor „FireChem”. Wnioski: Podstawowe cele sformułowane w nazwie projektu badawczo-rozwojowego nr OR00004812 pt. „Technologia zmniejszania zagrożenia wywołanego niekontrolowanym uwalnianiem substancji niebezpiecznych” zostały zrealizowane poprzez budowę BPL „Strażak” oraz wyposażenie go w m.in. detektor „FireChem”. Pojazd oddany do użytku jest wszechstronnie testowany i poddany szeregom prób terenowych. Po okresie prób na terenie CNBOP przewidziane jest jego przekazanie do wytypowanej JRG i użycie w warunkach realnej akcji ratowniczo-gaśniczej. Projekt traktuje zbudowanie BPL „Strażak” jako demonstratora technologii. Oznacza to, że po okresie prób i testów sporządzone zostanie sprawozdanie przedstawiające wnioski na temat dalszych losów tej konstrukcji. Autorzy żywią nadzieję, że konstrukcja po uwzględnieniu tych wniosków będzie mogła zostać wdrożona do produkcji seryjnej i wejdzie na wyposażenie jednostek PSP.
Objective: The aim of the article is to present the structure and performance of the detector for the chemical contamination detection, installed on the unmanned mobile platform “Strażak” (Fireman) presented in the review article BiTP Vol. 30 Issue 2, 2013, pp. 81-90. Introduction: The current advancement state of the firefighting techniques requires to take into account in rescue and firefighting action plans a thorough diagnosis of the risks that may appear during the execution of the task. The need to recognize the type of burning object is obvious. Preparing means to suppress the fire, one should take into account dangerous chemicals that are present on the site (chemical warfare agents, toxic industrial agents, explosives, gases forming a flammable mixture, radioactive sources, etc.). Until now, the PSP did not have appropriate equipment that would enable remote detection. Currently at the disposal of CNBOP is an unmanned platform “Strażak”, which was equipped with a detector for monitoring risk and generating an alarm signal when the threat is detected. Methodology: The detection of the threats was done by the multi-sensing measuring set: “FireChem”. This device was mounted as an integral part of “Strażak”. It is used to detect the emission of hazardous chemicals. It consists of three modules: electrochemical sensors, optical spectrometer and ion mobility spectrometer (IMS). With such a unique design this system is able to detect chemicals (toxic industrial compounds) with uncontrolled releases and chemical warfare that may arise in the event of a terrorist attack. An important part of the detection system is an optical spectrometer, which is primarily used to warn of entry into the hazardous zone. Using it, aliphatic hydrocarbons may be detected with high precision (methane, propane and butane mixture). This paper presents basic information about the construction and operation of the IMS detector and the results of measurements of selected substances by the detector “FireChem”. Conclusions: Main objectives in the R&D project no. OR00004812 “Technology for decreasing threat caused by uncontrolled releasing hazardous substances” were achieved by developing “Strażak” and equipping it with detector “FireChem”. The vehicle has been thoroughly tested and subjected to a series of field trials. After a period of testing CNBOP is anticipated to transfer to JRG and use under real emergency response. The project takes to build a BPL “Strażak” as a demonstrator of technology. This means that after a period of trial and testing, the report will be submitted with applications for the further aspects of the construction.
Źródło:
Bezpieczeństwo i Technika Pożarnicza; 2014, 1; 93-105
1895-8443
Pojawia się w:
Bezpieczeństwo i Technika Pożarnicza
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Survey of NGN migration profiles deployed by selected carriers in Europe, North America and Asia
Autorzy:
Michalski, W.
Powiązania:
https://bibliotekanauki.pl/articles/308118.pdf
Data publikacji:
2008
Wydawca:
Instytut Łączności - Państwowy Instytut Badawczy
Tematy:
NGN
IMS
softswitch based solution
NGN migration strategies
network evolution
Opis:
The paper presents the alternative migration profiles to next generation carrier network architecture. It describes the paths of development of fixed public network in- frastructure for five selected service providers. The carriers are selected as being in advanced stage of migration towards NGN. Moreover, examples of varying strategies ranging from full PSTN replacement and NGN overlay to constructing an NGN network from the ground up as well as examples of various migration strategies, especially based on IMS and softswitch solutions are presented.
Źródło:
Journal of Telecommunications and Information Technology; 2008, 3; 60-64
1509-4553
1899-8852
Pojawia się w:
Journal of Telecommunications and Information Technology
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Studies on FOX-7 Based Melt Cast High Explosive Formulations
Autorzy:
Mishra, V. S.
Vadali, S. R.
Garg, R. K.
Joshi, V. S.
Wasnik, R. D.
Asthana, S.
Powiązania:
https://bibliotekanauki.pl/articles/358915.pdf
Data publikacji:
2013
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Przemysłu Organicznego
Tematy:
melt cast
FOX-7
LOVEX
shock sensitivity
VOD
impulse
IMs
Opis:
The key driving force in modern explosive research is the development of low vulnerable high explosive (LOVEX) compositions for future applications in insensitive munitions (IMs). The increasing demand for LOVEX has led to exhaustive studies on low vulnerable explosives as a replacement for conventional cyclo-1,3,5-trimethylene-2,4,6-trinitramine (RDX) in 2,4,6-trinitrotoluene (TNT) melt cast high explosive formulations. In the present study, 1,1-diamino-2,2dinitroethene (FOX-7) has been evaluated as a possible RDX replacement in TNT based, non-aluminized as well as aluminized, melt cast formulation. FOX-7 based melt cast formulations were characterized for their sensitivity to mechanical/shock stimuli, velocity of detonation (VOD), blast parameters and thermal decomposition behavior. These characteristics are compared with the corresponding RDX based compositions as reference standard. The studies show that with little sacrifice on performance parameters, FOX-7 based, non-aluminized and aluminized, melt cast formulations are found to be less vulnerable, compared with the corresponding RDX based formulations.
Źródło:
Central European Journal of Energetic Materials; 2013, 10, 4; 569-580
1733-7178
Pojawia się w:
Central European Journal of Energetic Materials
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Using JAIN SLEE as an Interaction and Policy Manager for Enabler-based Services in Next Generation Networks
Autorzy:
Tsietsi, M.
Terzoli, A.
Wells, G.
Powiązania:
https://bibliotekanauki.pl/articles/226904.pdf
Data publikacji:
2010
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
service broker
SCIM
policy enforcer
NGN
IMS
JAIN SLEE
3GPP
OMA
Opis:
The IP Multimedia Subsystem is a telecommunications framework with a standard architecture for the provision of services. While the services themselves have not been standardised, standards do exist for basic technologies that can be re-used and aggregated in order to construct more complex services. These elements are called service capabilities by the 3GPP and service enablers by the OMA, both of which are reputable standards bodies in this area. In order to provide re-usability, there is a need to manage access to the service capabilities. Also, in order to build complex services, there is a further need to be able to manage and coordinate the interactions that occur between service capabilities. The 3GPP and the OMA have separately defined network entities that are responsible for handling aspects of these requirements, and are known as a service capability interaction manager (SCIM) and a policy enforcer respectively. However, the internal structure of the SCIM and the policy enforcer have not been standardised by the relevant bodies. In addition, as the SCIM and the policy enforcer have been defined through complementary yet separate processes, there is an opportunity to unify efforts from both bodies. This paper builds on work and standards defined by the bodies, and proposes the design of an interaction manager with features borrowed from both the SCIM and the policy enforcer. To help validate the design, we have identified a platform known as JAIN SLEE which we believe conforms to the model proposed, and we discuss how JAIN SLEE can be used to implement our ideas.
Źródło:
International Journal of Electronics and Telecommunications; 2010, 56, 2; 117-124
2300-1933
Pojawia się w:
International Journal of Electronics and Telecommunications
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Comparative Research of the Dynamic Youngs Module of Fibres
Badania porównawcze dynamicznego modułu Younga włókien
Autorzy:
Więcek, T.
Konecki, W.
Powiązania:
https://bibliotekanauki.pl/articles/232544.pdf
Data publikacji:
2012
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Biopolimerów i Włókien Chemicznych
Tematy:
włókna
dynamiczny moduł Younga
Impusowy Spektrometr Mechaniczny (IMS)
fibres
mechanical spectroscopy
dynamic modulus
Opis:
This work presents an investigation of the dynamic Young's modulus for fibres of varied thickness performed on an Impulse Mechanical Spectrometer (IMS) and Dynamic Mechanical Analyser (DMA). The IMS was designed and built by the authors and the DMA instrument was produced by TA Instrument Co (USA). Because different methods are applied for determination of the dynamic Young's modulus it was necessary to perform a comparison analysis of the results received from the IMS and DMA, which are currently the most frequently used testers. This analysis shows that an IMS can be used when a DMA cannot be applied. The parameter set comprising the dynamic Young's modulus for longitudinal vibrations can find application in material engineering in industry. The DMA method does not require the application of mathematical formulas to determine Young's modulus but requires calibration as apposed to IMS. Measurements of the elasticity modulus were carried out under automatically stabilised climatic conditions. The compliance of the results obtained allows us to evaluate positively the performance of the Impulse Mechanical Spectrometer. Comparison of the results makes it possible to determine the measuring possibilities of the DMA and IMS and show the advantages of IMS over DMA.
Praca przedstawia badania dynamicznego modułu Younga włókien zróżnicowanych grubością za pomocą opracowanego i wykonanego przez autorów nowego Impulsowego Spektrometru Mechanicznego ( IMS) oraz Dynamicznego Analizatora Mechanicznego (DMA) produkcji TA Instrument Co, (USA). Z uwagi na stosowanie różnych metod do pomiaru dynamicznego modułu Younga nastąpiła konieczność przeprowadzenia analizy porównawczej otrzymanych wyników z IMS i DMA który obecnie jest najbardziej popularnym przyrządem. Analiza pokazuje, że spektrometr może być użyty w sytuacjach gdy DMA nie może być już wykorzystany. Poszerzone charakteryzowanie włókien o dynamiczny moduł sprężystości podłużnej ma zastosowanie w inżynierii materiałowej w przemyśle. Metoda DMA nie wymaga stosowania zależności matematycznych do wyznaczania modułu Younga, jednak samo urządzenie wymaga kalibracji przed pomiarem w przeciwieństwie do IMS. Badania modułu sprężystości zostały przeprowadzone w automatycznie stabilizowanych warunkach klimatycznych. Zgodność uzyskanych wyników pozwala pozytywnie ocenić działanie Impulsowego Spektrometru Mechanicznego. Porównanie wyników pozwala na określenie możliwości pomiarowych DMA i IMS i wykazanie zalet IMS w odniesieniu do DMA.
Źródło:
Fibres & Textiles in Eastern Europe; 2012, 5 (94); 36-40
1230-3666
2300-7354
Pojawia się w:
Fibres & Textiles in Eastern Europe
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
A Hybrid Extension for IP Multicasting in Push-to-talk over Cellular Systems
Autorzy:
Gębarowski, T.
Powiązania:
https://bibliotekanauki.pl/articles/226638.pdf
Data publikacji:
2012
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
Push To Talk (PTT)
PoC
OMA PoC
PTT
IMS
SIP
RTP
IP Multicasting
VoIP
Opis:
OMA Push-to-talk over Cellular (abbr. PoC or PTT) as an IP-based service can be considered the first Voice-over-IP technology delivered in a broad manner in cellular networks world wide. Two key differences between PoC and regular voice communication systems are its half-duplex nature, which converts it into 'walkie-talkie' style of service and ability to establish group sessions between large groups of participants. As a matter of fact, majority of available PoC solutions are inefficient in handling groups of large size because they rely on IP unicasting for delivering media streams. This introduces not only redundancy and greater packet loss, but also increases computational and transmission effort. This paper proposes a hybrid IP multicasting extension for Push-to-talk technology allowing to reduce group size limitation significantly and increase the performance of large scale Push-to-talk systems. The proposed enhancement is elaborated and verified basing on an automatic testing framework feedback and some statistical measurements.
Źródło:
International Journal of Electronics and Telecommunications; 2012, 58, 1; 77-83
2300-1933
Pojawia się w:
International Journal of Electronics and Telecommunications
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Augmented speed control scheme of dual induction motors with mutual flux angle control loop
Autorzy:
Kondratenko, Dmytro
Lewicki, Arkadiusz
Łuksza, Krzysztof
Powiązania:
https://bibliotekanauki.pl/articles/27309952.pdf
Data publikacji:
2023
Wydawca:
Polska Akademia Nauk. Czasopisma i Monografie PAN
Tematy:
dual-motor drive
induction motors
IMs
five-leg voltage source inverter
FLVSI
rotor angle control
sensorless control
Opis:
This paper proposes an augmented speed control scheme of dual induction motors fed by a five-leg voltage source inverter (VSI) with a common/shared-leg. An additional control loop is proposed here and based on the mutual flux angle – the difference between flux angular positions of the IMs. The main purpose of this research is to minimize the energy losses in the common inverter leg by controlling the mutual flux angle, at equal angular speeds of both motors. Simulation and experimental studies were carried out and the effectiveness of the proposed control method was proven. The PLECS software package was used for the simulation tests. The laboratory prototypewas prepared for the experimental validation. All results were provided and discussed in this paper.
Źródło:
Archives of Electrical Engineering; 2023, 72, 4; 915--930
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Mobilne chromatografy gazowe łączone ze spektrometrami ruchliwości jonów do zastosowań w analizie zanieczyszczeń środowiska
Portable gas chromatographs joint with ion mobility spectrometers for analysis of environmental pollutants
Autorzy:
Grabka, M.
Budzyńska, E.
Witkiewicz, Z.
Puton, J.
Jasek, K.
Powiązania:
https://bibliotekanauki.pl/articles/270849.pdf
Data publikacji:
2017
Wydawca:
Centralny Ośrodek Badawczo-Rozwojowy Aparatury Badawczej i Dydaktycznej, COBRABiD
Tematy:
spektrometria ruchliwości jonów
chromatografia gazowa
GC-IMS
analityczne techniki łączone
ion mobility spectrometry
gas chromatography
analytical hyphenated techniques
Opis:
W ostatnich latach w analizie zanieczyszczeń środowiska obserwuje się silną tendencję do prowadzenia analiz w miejscu występowania analitów (on-site). Podejście takie minimalizuje problemy przechowywania i transportu próbek z miejsca ich pobrania do laboratorium stacjonarnego, jak również skraca czas od pobrania próbki do uzyskania wyniku analizy. Obecnie do prowadzenia analiz polowych stosowane są między innymi mobilne urządzenia będące połączeniem chromatografu gazowego ze spektrometrem ruchliwości jonów (ang. Gas Chromatography – Ion Mobility Spectrometry – GC-IMS). Zalety techniki GC-IMS i możliwość jej potencjalnego wykorzystania w urządzeniach przenośnych dostrzeżono już w latach 70. XX wieku. W praktyce połączenie chromatografu gazowego ze spektrometrem IMS nastręczało wiele problemów technicznych. Dopiero wprowadzenie licznych rozwiązań konstrukcyjnych dedykowanych dla GC-IMS oraz miniaturyzacja chromatografów gazowych i spektrometrów ruchliwości jonów, o względnie prostej budowie i małym zużyciu energii, umożliwiły konstrukcję hybrydowych przyrządów przenośnych. Kompaktowe urządzenia są wykorzystywane w miejscach, w których przyrządy stacjonarne nie mają zastosowania, np. w polowych analizach zanieczyszczeń środowiska, sygnalizatorach skażeń bojowymi środkami trującymi czy w sondach kosmicznych. W dziedzinie analitycznych urządzeń przenośnych przyrządy GC-IMS stanowią alternatywę dla urządzeń GC-MS, przewyższając je pod względem mobilności, prostoty konstrukcji oraz niektórych właściwości analitycznych (np. bardzo dobrej wykrywalności). Urządzenia tego typu charakteryzują się jednak niższą selektywnością niż przyrządy GC-MS. W pracy zawarto opis rozwoju mobilnych urządzeń GC-IMS od koncepcji poprzez pierwsze konstrukcje aż do obecnie dostępnych rozwiązań.
In the chemical analysis of environmental pollutions there is a strong tendency to perform fast on-site analysis using portable devices. This approach minimizes the problem of sample storage and transport from the place of collection to the stationary laboratory as well as reduces sampling-to-result time. Recently on-site analysis are often performed using mobile devices which are a combination of a gas chromatograph and ion mobility spectrometer (GC-IMS). Advantages of GC-IMS technique and its suitability for application as portable devices has already been noticed in the seventies of the twentieth century. As the first attempts have shown, the combination of a gas chromatograph and IMS detector in one device posed numerous technical issues. The gradual introduction of dedicated design solution and miniaturization of gas chromatographs and ion mobility spectrometers, allowed the construction of portable devices based on the joint technique. Compact devices are used in places where stationary instruments do not fit, e.g.: on-site analysis of environmental pollutions, portable CWA detectors or space probes. In the field of mobile analytical devices GC-IMS technique constitutes an alternative to GC-MS. GC-IMS devices exceeds GC-MS instruments in terms of mobility, simplicity, and some certain analytical characteristics (e.g. significantly lower detection limits). However device based on GC-IMS technique have a much lower selectivity than GC-MS instruments. This study presents an overview of the development of mobile GC-IMS devices from conception through the first constructions to currently available solutions in this domain.
Źródło:
Aparatura Badawcza i Dydaktyczna; 2017, 22, 2; 107-116
2392-1765
Pojawia się w:
Aparatura Badawcza i Dydaktyczna
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Strategie migracji sieci telekomunikacyjnych w kierunku sieci NGN w wybranych krajach
Migration strategies of PSTN to NGN in selected countries
Autorzy:
Michalski, W.
Powiązania:
https://bibliotekanauki.pl/articles/317546.pdf
Data publikacji:
2008
Wydawca:
Instytut Łączności - Państwowy Instytut Badawczy
Tematy:
NGN
IMS
sieć użytku publicznego
sieć stała
sieć ruchoma
strategie modernizacji sieci
PSTN
fixed network
mobile network
network transformation paths
Opis:
Zaprezentowano kierunki rozwoju publicznych sieci stałych w czterech krajach, wyróżniających się stopniem zaawansowania działań związanych z transformacją sieci klasycznych (PSTN) w sieci NGN. Przedstawiono strategie informatyzacji sieci oparte na systemie IMS oraz na urządzeniach typu softswitch. Podano przykłady różnych rodzajów modernizacji sieci telekomunikacyjnych, od zastępowania istniejącej infrastruktury nowymi rozwiązaniami technicznymi do budowania nakładkowych sieci NGN.
In this paper, the directions of development of PSTN network in four countries are presented. The countries selected have the most advanced transformation process of their existing network to IP-based architecture. The possibilities of adoption of softswitch as well as IP multimedia system - based architecture solutions to transfer subscribers to IP-based session are discussed. Examples of alternative NGN migration paths ranging from PSTN replacement to NGN overlay are also presented.
Źródło:
Telekomunikacja i Techniki Informacyjne; 2008, 1-2; 51-57
1640-1549
1899-8933
Pojawia się w:
Telekomunikacja i Techniki Informacyjne
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Approximation of message inter-arrival and inter-departure time distributions in IMS/NGN architecture using phase-type distributions
Autorzy:
Kaczmarek, S.
Sac, M.
Powiązania:
https://bibliotekanauki.pl/articles/308647.pdf
Data publikacji:
2013
Wydawca:
Instytut Łączności - Państwowy Instytut Badawczy
Tematy:
call processing performance
IMS
message interarrival time distributions
message inter-departure time distributions
NGN
phase type distributions
traffic model
Opis:
Currently it is assumed that requirements of the information society for delivering multimedia services will be satisfied by the Next Generation Network (NGN) architecture, which includes elements of the IP Multimedia Subsystem (IMS) solution. In order to guarantee Quality of Service (QoS), NGN has to be appropriately designed and dimensioned. Therefore, proper traffic models should be proposed and applied. This requires determination of queuing models adequate to message inter-arrival and interdeparture time distributions in the network. In the paper the above mentioned distributions in different points of a single domain of NGN are investigated, using a simulation model developed according to the latest standards and research. Relations between network parameters and obtained message inter-arrival as well as interdeparture time distributions are indicated. Moreover, possibility of approximating the above mentioned distributions using phase-type distributions is investigated, which can be helpful in identifying proper queuing models and constructing an analytical model suitable for NGN.
Źródło:
Journal of Telecommunications and Information Technology; 2013, 3; 9-18
1509-4553
1899-8852
Pojawia się w:
Journal of Telecommunications and Information Technology
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Scenariusze ewolucji Międzynarodowego Systemu Walutowego w świetle teorii pieniądza
Scenarios for the evolution of the International Monetary System in the light of the theories of money
Autorzy:
Chrzonstowski, Antoni
Powiązania:
https://bibliotekanauki.pl/articles/485457.pdf
Data publikacji:
2018-06-29
Wydawca:
Bankowy Fundusz Gwarancyjny
Tematy:
Międzynarodowy System Walutowy,
MSW
Międzynarodowy Fundusz Walutowy
MFW
specjalne prawa ciągnienia
SDR
standard złota
parytet gospodarczy
The International Monetary System
IMS
the International Monetary Fund
IMF
special drawing rights
SD
the gold standard
the economic parity
Opis:
W artykule zostały przeanalizowane trzy scenariusze rozwoju międzynarodowego systemu walutowego z punktu widzenia trzech teorii pieniądza – metalizmu, teorii zaczepu oraz nowoczesnej teorii monetarnej. Najbardziej obiecujący scenariusz z punktu widzenia efektywności MSW wiąże się z wprowadzeniem odrębnej waluty światowej na bazie umownej jednostki monetarnej Międzynarodowego Funduszu Walutowego, jaką stanowią specjalne prawa ciągnienia – SDR. Odrębna waluta światowa swojej wartości i stabilności nie może czerpać z siły władz monetarnych jakiegokolwiek państwa. Może swoją siłę budować na podwójnym zaczepie: np. z parytetu kruszcowego, który mógłby podlegać okresowym zmianom oraz z parytetu gospodarczego, który mógłby odnosić się do wszystkich gospodarek krajowych poprzez wycenę ustanowionych limitów emisji dwutlenku węgla.
The article analysed three scenarios for the development of the International Monetary System (IMS) in light of the three theories of money – precious metals as money, theory of hitch and modern monetary theory. The most promising scenario in view of effectiveness of the IMS involves the introduction of a separate global currency based on the contractual monetary unit of the International Monetary Fund, which are the Special Drawing Rights – SDR. The value and the stability of the newly introduced world currency cannot derive from the strength of the monetary authorities of any sovereign country. Its strength, however, could be built upon a double hitch: e.g. from the gold standard, which could be subject to periodic change and the economic parity, which would apply to all national economies by introducing of the valuation of carbon dioxide emission limits.
Źródło:
Bezpieczny Bank; 2018, 1 (70); 34-51
1429-2939
Pojawia się w:
Bezpieczny Bank
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-15 z 15

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies