Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "Hollow Core" wg kryterium: Temat


Wyświetlanie 1-12 z 12
Tytuł:
Control of the transmission length in the prestressed hollow-core slabs using values of the strand end slip
Kontrola wartości długości zakotwienia cięgien w sprężonych płytach kanałowych przy użyciu wartości poślizgu splotów
Autorzy:
Tur, V
Fic, S.
Powiązania:
https://bibliotekanauki.pl/articles/390877.pdf
Data publikacji:
2013
Wydawca:
Politechnika Lubelska. Wydawnictwo Politechniki Lubelskiej
Tematy:
Hollow-core slabs
transmission length
slippage
strand
płyta kanałowa
długość zakotwienia
poślizg
splot
Opis:
It is shown [1] that even though the production of precast pre-tensioned concrete elements started more than 50 years ago, no one has ever succeeded in determining the real transmission length or in obtaining adequate measures to control it, due to the quality of the production. These arrears are confirmed by the study of existing standards. In general, it is assumed that the measurement of the magnitude of the slippage of strand at the end of hollow core prestressed slab is an indirect method of estimation and control of the value of the transmission length. One should mention that EN1168 and EN13369 that regulate requirements of designing and production of hollow-core slabs are applied as the method of control. Based on a particular bond-slip relation for strands, a nonlinear equation is developed for the transmission length and for the slippage of prestressed strand, taking into account such factors as the concrete strength at transfer, the degree of the initial prestress type and diameter of tendons. These equations have been used for the control of transmission length of the strands calculated by different methods available recently, including a code provision. Then they were compared to measured data, obtained in production control of the hollow-core slabs.
Bazując na szczególnej relacji przyczepność – poślizg dla splotów, opracowano równania nieliniowe dla długości zakotwienia i dla poślizgu sprężonych splotów przy uwzględnieniu czynników: wytrzymałości betonu, efektywności początkowego sprężenia i rozmiaru splotu. Te równania zostały użyte do skontrolowania długości zakotwienia sprężonych splotów obliczonych za pomocą różnych metod dostępnych w ostatnim czasie, uwzględniając zalecenia normowe, które zostały porównane z wynikami pomiarów uzyskanych podczas kontroli procesu produkcyjnego płyt kanałowych.
Źródło:
Budownictwo i Architektura; 2013, 12, 1; 171-178
1899-0665
Pojawia się w:
Budownictwo i Architektura
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Niezamierzony efekt częściowego zamocowania stropów ze sprężonych płyt kanałowych
Autorzy:
Derkowski, W.
Powiązania:
https://bibliotekanauki.pl/articles/162629.pdf
Data publikacji:
2014
Wydawca:
Polski Związek Inżynierów i Techników Budownictwa
Tematy:
strop
płyta strunobetonowa
płyta kanałowa
podparcie
zamocowanie
nośność na ścinanie
floor
prestressed concrete slab
hollow core slab
support
fixing
shear load capacity
Źródło:
Przegląd Budowlany; 2014, R. 85, nr 1, 1; 24-27
0033-2038
Pojawia się w:
Przegląd Budowlany
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Nośność płyt kanałowych na ścinanie w konstrukcjach typu Slim Floor
Load-bearing capacity of hollow slabs to cutting in Slim Floor constructions
Autorzy:
Bodzak, P.
Powiązania:
https://bibliotekanauki.pl/articles/162294.pdf
Data publikacji:
2018
Wydawca:
Polski Związek Inżynierów i Techników Budownictwa
Tematy:
strop
konstrukcja
Slim Floor
płyta kanałowa
oparcie
odporność na ścinanie
floor
structure
hollow core slab
supporting
shear resistance
Opis:
W artykule na podstawie wyników badań modeli w skali naturalnej przeanalizowano wpływ zastosowania stalowych belek kapeluszowych WQ oraz Deltabeam w układach stropów typu Slim Floor na nośność na ścinanie sprężonych płyt kanałowych. Wykazano, że oprócz podatności belek istotny wpływ na siły niszczące mają warunki podparcia płyt HC na pasach dolnych stalowych belek kapeluszowych.
Based on results of research of models in the natural scale, the article analyzes the impact of application of steel WQ hat beams as well as Deltabeam in layouts of Slim Floor constructions on the load-bearing capacity to cutting of prestressed hollow slabs. The research has indicated that apart from susceptibility of the beams, a significant impact on the destructive forces is exerted by conditions of support of the HC slabs on lower bands of steel hat beams.
Źródło:
Przegląd Budowlany; 2018, 89, 7-8; 34-39
0033-2038
Pojawia się w:
Przegląd Budowlany
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Polski rynek rozwiązań stropowych – najpopularniejsze systemy, cz.2
Popularity and criteria for the selection of floor systems in Poland, part 2
Autorzy:
Kisiołek, A.
Powiązania:
https://bibliotekanauki.pl/articles/160344.pdf
Data publikacji:
2018
Wydawca:
Polski Związek Inżynierów i Techników Budownictwa
Tematy:
system stropowy
popularność
strop gęstożebrowy
Teriva 4 0/1
płyta prefabrykowana
płyta kanałowa
płyta żelbetowa
płyta sprężona
Filigran
wybór systemu
floor system
popularity
rib-and-slab floor
prefabricated slab
hollow core slab
reinforced concrete slab
prestressed slab
system selection
Opis:
W tej części publikacji podjęty został temat niezgodności z eurokodem powszechnie stosowanych stropów Teriva 4,0/1, a następnie zaprezentowane zostaną stropy z kanałowych płyt prefabrykowanych (żelbetowych i strunobetonowych) z uwzględnieniem lekkiego stropu panelowego Smart oraz zespolony strop typu Filigran.
This part of the publication presents the aspect of non-compliance with the Eurocode of common Teriva flooring types (4.0 /1), followed by the hollowcore concrete slabs (reinforced and prestressed concrete elements) including Smart lightweight floors and Filigran-type composite slab systems.
Źródło:
Przegląd Budowlany; 2018, 89, 1; 22-26
0033-2038
Pojawia się w:
Przegląd Budowlany
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Popularność oraz kryteria wyboru systemów stropowych w Polsce, cz.1
Popularity and selection criteria of ceiling systems in Poland, part 1
Autorzy:
Kisiołek, A.
Powiązania:
https://bibliotekanauki.pl/articles/162946.pdf
Data publikacji:
2017
Wydawca:
Polski Związek Inżynierów i Techników Budownictwa
Tematy:
strop
system konstrukcyjny
strop monolityczny
strop gęstożebrowy
strop zespolony
strop kanałowy
strop sprężony
popularność
kryteria doboru
floor
structural system
monolithic floor
beam and block floor
composite floor
hollow core slab floor
prestressed slab floor
popularity
selection criteria
Opis:
Rynek systemowych produktów stropowych stanowi tematykę o charakterze techniczno-ekonomicznym, praktycznie nie podejmowaną przez ekonomistów. O ile publikuje się na tematy związane z kierunkami i trendami we współczesnym budownictwie, to dla menedżerów działających w tym segmencie rynku znana autorowi literatura nie dostarcza wielu danych. W części I artykułu przedstawiono wybrane wyniki badań dotyczące popularności poszczególnych systemów stropowych oferowanych na rynku polskim.
The market of systemic ceiling products constitutes a technical as well as economic subject, which is virtually ignored by economists. There are publications devoted to issues regarding directions and trends in modern building industry, for managers working in this market segment. Part I of the article presents selected test results regarding popularity of particular ceiling systems offered on the Polish market.
Źródło:
Przegląd Budowlany; 2017, 88, 5; 28-32
0033-2038
Pojawia się w:
Przegląd Budowlany
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Praca statyczna stropów z płyt kanałowych w warunkach czterokrawędziowego oparcia
Static work of floor slabs made of hollow core slabs in conditions four-edge backrest
Autorzy:
Zając, Jakub
Drobiec, Łukasz
Jasiński, Radosław
Grzyb, Krzysztof
Kisiołek, Artur
Powiązania:
https://bibliotekanauki.pl/articles/2202690.pdf
Data publikacji:
2022
Wydawca:
Polski Związek Inżynierów i Techników Budownictwa
Tematy:
płyta kanałowa
strop sprężony
praca statyczna
efekt długotrwały
badanie eksperymentalne
model badawczy
analiza obliczeniowa
hollow core slab
prestressed slab floor
statical work
long-term effect
experimental investigation
test model
computational analysis
Opis:
Stropy z płyt kanałowych pomimo ponad stu lat historii i miliarda metrów kwadratowych wykonanych tego typu konstrukcji w samej Europie nadal w pewnych aspektach projektowych budzą wątpliwości. W artykule przedstawiono wyniki wpływu krótkotrwałych i długotrwałych obciążeń na pełnoskalowy strop z płyt kanałowych o wymiarach 6,31 x 6,31 m. Badanie przeprowadzono pod niesymetrycznym obciążeniem grawitacyjnym, a ostatni pomiar wykonano po 665 dniach. Wykonana analiza obliczeniowa wykazała ponad trzykrotne przeszacowanie ugięć modelu płyty jednokierunkowej w odniesieniu do badań doświadczalnych. Przedstawiono uproszczone przestrzenne modele obliczeniowe, wraz z podaniem kryteriów stosowania. Badania i analizy wykazały, że powszechnie stosowana metoda obliczeniowa prowadzi do bardzo konserwatywnych wyników - nie oddając rzeczywistej charakterystyki pracy stropów z płyt kanałowych.
Despite over a hundred years of history and a billion square meters made in Europe alone, hollow-core slabs still raise doubts in some design aspects. The article presents the results of the short-term and long-term loads on a full-scale hollow-core slab with dimensions of 6.31 x 6.31 m. The test was carried out under an unsymmetrical gravity load, and the last measurement was carried out after 665 days. The computational analysis indicates over three times overestimated deflections of the one-way slab model compared to the experimental tests. Simplified spatial computational models are presented, along with application criteria. The research and the presented analyses have shown that the commonly used calculation method leads to very conservative results, without reflecting the actual performance characteristics of hollow-core slabs.
Źródło:
Przegląd Budowlany; 2022, 93, 11-12; 127--132
0033-2038
Pojawia się w:
Przegląd Budowlany
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Prawidłowość wykonywania wycięć w strunobetonowych płytach kanałowych oraz konsekwencje błędów w tym zakresie i sposoby naprawynadal
The correctness of making cut-outs in prestressed concrete hollow-core slabs, the consequences of errors and methods of repair
Autorzy:
Błaszczyński, Tomasz Z.
Gwozdowski, Błażej
Sinacki, Dawid
Powiązania:
https://bibliotekanauki.pl/articles/128808.pdf
Data publikacji:
2020
Wydawca:
PWB MEDIA Zdziebłowski
Tematy:
awaria
płyta kanałowa
strop strunobetonowy
wycięcie
projektowanie
otwór
płyta z otworem
błąd
naprawa
failure
hollow core slab
prestressed slab
cutout
designing
hole
plate with hole
error
repair
Opis:
Stosowanie prefabrykowanych płyt strunobetonowych stało się tak powszechne, że zajmują się nimi już wszyscy, uważając te elementy za nieskomplikowane. Dotyczy to również wykonawstwa oraz modernizacji już zrealizowanych obiektów budowlanych. Pomimo szczegółowych wytycznych producentów i projektantów tego rodzaju płyt problemem wciąż jest zbyt duża dowolność w ich wycinaniu i wykonywaniu otworów, zwłaszcza na etapie realizacji lub zmian sposobu użytkowania w trakcie istnienia obiektów budowlanych. W pracy przedstawiono ogólne zasady bezpiecznego wycinania i otworowania prefabrykowanych płyt strunobetonowych oraz przypadki błędów popełnionych przy projektowaniu i realizacji stropów płytowych, prowadzące do stanów awaryjnych.
The usage of prefabricated prestressed hollow-core slabs has become so widespread that everyone is already considering these elements as simple. This also concerns the execution and modernization of already realized buildings. Despite the detailed guidelines for designers of this type of slabs, still is a problem with incorrectly make cut-offs and holes, especially at the stage of implementation or changes in the way of use during the existence of buildings. The paper presents general principles for safe cutting and opening of prefabricated prestressed hollow-core slabs and cases of errors made in the design and implementation of slab floors, leading to emergency conditions.
Źródło:
Builder; 2020, 24, 9; 36-40
1896-0642
Pojawia się w:
Builder
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Reinforcement of cracked hollow-core slabs during the construction of the building
Autorzy:
Szeląg, Romuald
Powiązania:
https://bibliotekanauki.pl/articles/2172410.pdf
Data publikacji:
2022
Wydawca:
Centrum Rzeczoznawstwa Budowlanego Sp. z o.o.
Tematy:
hollow-core slabs
scratches
cracks
damage
reinforcements
płyta kanałowa
zadrapanie
pęknięcie
szkoda
wzmocnienie
Opis:
During the implementation of investment processes with the use of ready-made prefabricated elements, undesirable situations may occur that cause scratches, excessive deflections or damage. This is due to the fact that defects occur during transport, storage or incorrect loading of the elements. The conducted tests and technical assessments often allow the use of built-in elements, however, under the conditions of the need to make their reinforcements. This may be due to the scale of damage or defects made during molding and, as a consequence, the implementation of prefabricated elements with too low load capacity. Taking action each time should allow for the implementation of reinforcements of the elements, limiting the need to dismantle them, which would result in their irretrievable destruction. The implementation of reinforcements allows to reduce the generation of waste from new elements and allows for the proper management of already produced prefabricated elements. Used elements with reinforcements should be subject to technical inspection in the same periods as other structural elements. Proper implementation of repairs allows for the final effect to be similar to the parameters of elements free of technical defects. Due to the existing problem of damage to new elements of prefabricated channel ceilings, solutions have been developed that can be used to reinforce the elements without the need to dismantle them from the places of installation, while reducing the time spent on the process.
Źródło:
Inżynieria Bezpieczeństwa Obiektów Antropogenicznych; 2022, 4; 54--62
2450-1859
2450-8721
Pojawia się w:
Inżynieria Bezpieczeństwa Obiektów Antropogenicznych
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Statyczna praca kanałowych płyt stropowych opartych na dźwigarach podatnych
Statical work of hollow core slabs on flexible support
Autorzy:
Surma, Mateusz
Derkowski, Wit
Powiązania:
https://bibliotekanauki.pl/articles/161390.pdf
Data publikacji:
2019
Wydawca:
Polski Związek Inżynierów i Techników Budownictwa
Tematy:
płyta kanałowa
płyta stropowa
praca statyczna
Slim Floor
podpora podatna
hollow core slab
floor slab
static work
flexible support
Opis:
Artykuł koncentruje się na wybranych aspektach statycznej pracy prefabrykowanych sprężonych płyt wielokanałowych wspartych na wspornikach elastycznych, tzw. struktury typu Slim Floor. Pierwsza część przedstawia zarys historyczny pojawienia się i rozwoju różnych rodzajów stalowych, betonowych i stalowo-betonowych belek zespolonych, wykorzystywanych w prefabrykowanych płaskich stropach, dla których wysokość belki jest tylko nieznacznie większa niż nominalna wysokość płyt. Opisano ponadto ogólną procedurę obliczania wytrzymałości na ścinanie płyt wielokanałowych według zaleceń fib. Wytrzymałość na ścinanie płyt wielokanałowych jest znacząco zredukowana przez odkształcenie poprzeczne systemu płyt stropowych w wyniku odchylenia wiotkiej belki.
The paper is focused on selected aspects of static work of prestressed precast hollow core slabs supported on flexible supports, so-called Slim Floor structures. The first part presents a historical review of the emergence and development of various types of steel, concrete and steel-concrete composite beams, used in precast flat floors, for which the height of the beam is only slightly bigger than the nominal height of the slabs. A general procedure for calculating the shear capacity of hollow core slabs according to the fib recommendations is also described. The shear capacity of hollow core slabs is significantly reduced by the transverse deformation of the floor slab system due to the deflection of the slender beam.
Źródło:
Przegląd Budowlany; 2019, 90, 3; 8-13
0033-2038
Pojawia się w:
Przegląd Budowlany
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Strunobetonowe płyty kanałowe w stropie o nośności qk = 10 i 15 kN/m2 z równoczesnym ruchem dwóch wózków widłowych Qk = 20 kN każdy
Prestressed concrete hollow core slabs in the floor with the load capacity of qk = 10 and 15 kN/m2 with simultaneous movement of two forklift trucks Qk = 20 kN each
Autorzy:
Michałek, Jarosław
Łodo, Aleksy
Kozioł, Piotr
Powiązania:
https://bibliotekanauki.pl/articles/2142047.pdf
Data publikacji:
2022
Wydawca:
Polski Związek Inżynierów i Techników Budownictwa
Tematy:
płyta kanałowa
strop
płyta strunobetonowa
wzmocnienie
eksploatacja
nośność
obciążenie graniczne
wózek widłowy
nadbeton
hollow core slab
prestressed concrete slab
floor
strengthening
exploitation
load capacity
limit load
forklift truck
concrete topping
Opis:
Przedmiotem artykułu jest weryfikacja nośności stropu magazynu surowców o wymiarach 90,0×12,5 m wykonanego z kanałowych płyt strunobetonowych o wysokości 265 mm i modularnej szerokości 1,20 m. Po ułożeniu płyt kanałowych na ścianach zewnętrznych i wewnętrznych piwnicy oraz wykonaniu wieńców i złączy podłużnych między płytami zauważono, że w obliczeniach do projektu stropu uwzględniono obciążenia zmienne qk = 10 i 15 kN/m2, zapominając o siłach skupionych wywoływanych przez dwa wózki widłowe o udźwigu Qk = 20 kN każdy. Wstrzymano prace wykończeniowe stropu w celu opracowania sposobu przystosowania go do przenoszenia obciążeń wymienionych wyżej. W artykule przedstawiono analizy, wnioski i zalecenia dotyczące możliwości uzyskania żądanej przez inwestora nośności stropu z równoczesną eksploatacją wózków widłowych. Wyniki analiz wykorzystano do opracowania projektu wzmocnień konstrukcji stropu na ścinanie i zginanie poprzez zespolenie płyt z nadbetonem będącym posadzką magazynu oraz dodatkowo na ścinanie przez wypełnienie betonem części przypodporowej kanałów w płytach na długości obliczeniowej lpt2 = 0,90 m przekazywania siły sprężającej z cięgien na beton.
The subject of the paper is verification of the load capacity of the floor of the raw material warehouse with dimensions of 90,0×12,5 m made of hollow-core prestressed concrete slabs 265 mm high and a modular width of 1,20 m. After placing the hollow-core slabs on the external and internal walls of the basement and making the tie beams and longitudinal joints between the slabs, it was noticed that in calculations for the detailed design of the floor with the live load qk = 10 and 15 kN/m2 no account was taken of the concentrated forces caused by two forklifts with a load capacity of Qk = 20 kN each. Finishing works of the ceiling were stopped in order to work out how to adapt it to transfer the loads mentioned above. The paper presents analyses, conclusions and recommendations concerning the possibility of obtaining the floor load capacity required by the investor with simultaneous use of forklifts. The results of the analysis has been used to strengthen the floor structure for shear and bending by joining the slabs with the 80 mm thick concrete topping. Additionally, higher shear capacity has been obtained by filling the supporting part of the channels (lpt2 = 0.90 m) with concrete at tendon transmission length.
Źródło:
Przegląd Budowlany; 2022, 93, 5-6; 105--111
0033-2038
Pojawia się w:
Przegląd Budowlany
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wpływ nadbetonu na pracę sprężonych płyt stropowych HC na podporach podatnych
Influence of concrete topping on behaviour of prestressed Hollow Core floor slabs on flexible supports
Autorzy:
Derkowski, W.
Surma, M.
Powiązania:
https://bibliotekanauki.pl/articles/390107.pdf
Data publikacji:
2013
Wydawca:
Politechnika Lubelska. Wydawnictwo Politechniki Lubelskiej
Tematy:
Hollow Core
konstrukcje Slim Floor
nadbeton
podatność podpór
stropy prefabrykowane
flexible support
Slim Floor Structures
concrete topping
precast slabs
Opis:
Stropy Slim Floor (SF), to konstrukcje z płyt kanałowych (HC) opartych na smukłych belkach, w których wysokość dźwigara zazwyczaj nieznacznie przekracza wysokość prefabrykatu stropowego. Wraz ze wzrostem ugięcia podpór następuje deformacja układu płyt stropowych, w konsekwencji czego w prefabrykacie pojawiają się dodatkowe poprzeczne naprężenia normalne i styczne, mogące spowodować ukośne zarysowanie i w konsekwencji zniszczenie zewnętrznych żeberek płyt. Może również dojść do podłużnego zarysowania dolnej powierzchni płyty. Pomimo częstych realizacji tego typu konstrukcji, w obowiązującej normie EN 1168 znalazł się jedynie lakoniczny zapis o potrzebie uwzględnienia redukcji obliczeniowej nośności na ścinanie - nie podano jednak żadnej procedury obliczeniowej. Powszechnie uważa się, że zmniejszenie niekorzystnego wpływu stycznych naprężeń ścinających w żeberku płyty można osiągnąć poprzez wypełnienie betonem kanałów w skrajnych fragmentach płyty HC lub ułożenie monolitycznej warstwy nadbetonu. Wytyczne fib są praktycznie jedynym dokumentem pozwalającym określić nośność stropów SF z uwzględnieniem wpływu nadbetonu lub wypełnienia kanałów – w referacie skrótowo opisano ten model obliczeniowy. W celu określenia wpływu nadbetonu na pracę sprężonych płyt HC na podporach podatnych, wykonano szereg analiz obliczeniowych uwzględniających m.in. wpływ grubości nadbetonu, wartość współczynnika tarcia między nadbetonem a prefabrykatem, kolejności betonowania styków pionowych i warstwy nadbetonu, a także ilości zbrojenia w betonie uzupełniającym. Wyniki przeprowadzonych obliczeń, wraz z wnioskami z nich wynikającymi, przedstawiono w niniejszym artykule.
Slim Floors (SF) are the structures made of the Hollow Core (HC) slabs supported on the slender beams, where the beam height is usually slightly greater than the height of precast slab element. With the increase of the supports' deflection, the deformation of the HC slab occurs, and in consequence, additional transverse normal and shear stresses appear in the precast element, which can cause a diagonal cracking and destruction of external webs of this element. It may also result in longitudinal cracks on bottom surface of the slab. Despite the frequent implementation of this type of structures, the existing standard EN 1168 gave only a brief record of the need to take the reduction in design shear capacity into account, but is not given any calculation procedure. It is widely believed that reduction of unfavourable effects of shear stress in the HC slab’s web can be achieved by filling the cores with concrete or arrangement of the monolithic layer or concrete topping. The fib guidelines are practically the only one document which allows to determine the shear capacity of SF slabs, including the influence of concrete topping or core filling – brief description of this design model is presented in the paper. In order to determine the effect of concrete topping on the behaviour of prestressed HC slabs on the flexible supports, a number of calculation analyzes were performed, which take into account the effects of thickness of the concrete topping, the value of the friction coefficient between the concrete topping and the precast element, the sequence of concreting of vertical joints and topping layer and the amount of supplementary reinforcement in the topping. The results of the calculations, and the conclusions derived from them, are presented in the article.
Źródło:
Budownictwo i Architektura; 2013, 12, 1; 107-114
1899-0665
Pojawia się w:
Budownictwo i Architektura
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wpływ sposobu podparcia sprężonych płyt kanałowych z wypełnionymi kanałami na ich nośność na ścinanie
The effect of the support type on shear capacity of prestressed hollow core slabs with and without filled cores
Autorzy:
Bodzak, P.
Sowa, Ł.
Powiązania:
https://bibliotekanauki.pl/articles/105389.pdf
Data publikacji:
2017
Wydawca:
Politechnika Rzeszowska im. Ignacego Łukasiewicza. Oficyna Wydawnicza
Tematy:
ścinanie
płyta kanałowa
podpora sprężysta
płyta
kanał
wypełnienie
hollow-core slabs
flexible supports
filled core
shear
Opis:
Norma dotycząca sprężonych płyt kanałowych, jako sposób zwiększenia wytrzymałości płyty na ścinanie, podaje możliwość uwzględnienia wypełnienia wnętrza kanałów betonem. Dotychczasowe wyniki badań wykazały, że nośność na ścinanie płyt kanałowych ulega znacznej redukcji, nawet o 50% w wyniku podparcia na podporach sprężystych. W artykule zaprezentowano wyniki badań eksperymentalnych, których celem było określenie wpływu wypełnienia przedskrajnych kanałów płyt opartych na podporze sztywnej i odkształcalnej na ich nośność na ścinanie.
According to the Standard recommendation it is possible to take into account the filling of the hollow core in order to improve shear capacity. Recent test results showed that shear capacity of the hollow core slabs supported on flexible support are much lower in comparison with those resting on non-flexible supports. In the paper experimental tests results of the hollow core slabs with and without filling supported on non-flexible and flexible supports are presented.
Źródło:
Czasopismo Inżynierii Lądowej, Środowiska i Architektury; 2017, 64, 3/I; 333-340
2300-5130
2300-8903
Pojawia się w:
Czasopismo Inżynierii Lądowej, Środowiska i Architektury
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-12 z 12

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies