Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "Heat Transfer" wg kryterium: Temat


Tytuł:
Subcooled flow boiling of a citric acid aqueous mixture
Autorzy:
Abdolhossein Zadeh, Mohammad Amin
Nakhjavani, Shima
Powiązania:
https://bibliotekanauki.pl/articles/240356.pdf
Data publikacji:
2020
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
flow boiling
heat transfer
citric acid
bubble formation
chen type model
Opis:
In the present research, an experimental investigation was conducted to assess the heat transfer coefficient of aqueous citric acid mixtures. The experimental facility provides conditions to assess the influence of various operating conditions such as the heat flux (0–190 kW/m2), mass flux (353–1059 kg/m2s) and the concentration of citric acid in water (10%–50% by volume) with a view to measure the subcooled flow boiling heat transfer coefficient of the mixture. The results showed that two main heat transfer mechanisms can be identified including the forced convective and nucleate boiling heat transfer. The onset point of nucleate boiling was also identified, which separates the forced convective heat transfer domain from the nucleate boiling region. The heat transfer coefficient was found to be higher in the nucleate boiling regime due to the presence of bubbles and their interaction. Also, the influence of heat flux on the heat transfer coefficient was more pronounced in the nucleate boiling heat transfer domain, which was also attributed to the increase in bubble size and rate of bubble formation. The obtained results were also compared with those theoretically obtained using the Chen type model and with some experimental data reported in the literature. Results were within a fair agreement of 22% against the Chen model and within 15% against the experimental data.
Źródło:
Archives of Thermodynamics; 2020, 41, 1; 193-217
1231-0956
2083-6023
Pojawia się w:
Archives of Thermodynamics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Computational analysis for the effect of the taper angle and helical pitch on the heat transfer characteristics of the helical cone coils
Analiza numeryczna różnic między charakterystykami działania stożkowych wężownic spiralnych i zwykłych wężownic spiralnych stosowanych jako osuszacze w zespołach osuszania i nawilżania w instalacjach odsalania wody
Autorzy:
Abo-Elazm, M
Ragheb, A
Elsafty, A
Teamah, M
Powiązania:
https://bibliotekanauki.pl/articles/139629.pdf
Data publikacji:
2012
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
computational analysis
helical cone coil
heat exchanger
heat transfer
analiza numeryczna
wężownica spiralna stożkowa
wymiennik ciepła
wymiana ciepła
Opis:
This numerical research is devoted to introducing the concept of helical cone coils and comparing the performance of helical cone coils as heat exchangers to the ordinary helical coils. Helical and spiral coils are known to have better heat and mass transfer than straight tubes, which is attributed to the generation of a vortex at the helical coil. This vortex, known as the Dean Vortex, is a secondary flow superimposed on the primary flow. The Dean number, which is a dimensionless number used in describing the Dean Vortex, is a function of Reynolds Number and the square root of the curvature ratio, so varying the curvature ratio for the same coil would vary the Dean Number. Numerical investigation based on the commercial CFD software fluent is used to study the effect of changing the structural parameters (taper angle of the helical coil, pitch and the base radius of curvature changes while the height is kept constant) on the Nusselt Number, heat transfer coefficient and coil outlet temperature. Six main coils having pipe diameters of 10 and 12.5 mm and base radius of curvature of 70, 80 and 90 mm were used in the investigation. It was found that, as the taper angle increases, both Nusselt Number and the heat transfer coefficient increase, also the pitch at the various taper angles was found to have an influence on Nusselt Number and the heat transfer coefficient. A MATLAB code was built to calculate the Nusselt Number at each coil turn, then to calculate the average Nusselt number for all of the coil turns. The MATLAB code was based on empirical correlation of Manlapaz and Churchill for ordinary helical coils. The CFD simulation results were found acceptable when compared with the MATLAB results.
W pracy przedstawiono badania numeryczne mające na celu prezentację koncepcji stożkowych wężownic spiralnych i porównanie charakterystyk ich działania jako wymienników ciepła do charakterystyk zwykłych wężownic spiralnych. Jak wiadomo, wężownice spiralne i stożkowe charakteryzują się lepszym przenoszeniem ciepła i masy niż proste rury, co jest związane z powstawaniem wiru w wężownicy spiralnej. Ten tzw. wir Deana (Dean Vortex) jest przepływem wtórnym, nałożonym na przepływ pierwotny. Bezwymiarowy współczynnik Deana, stosowany do opisu wiru Deana, jest funkcją liczby Reynoldsa i pierwiastka kwadratowego ze współczynnika krzywizny, toteż liczba Deana zmienia się dla danej wężownicy wraz z jej krzywizną. Obliczenia numeryczne wykonano przy użyciu komercyjnego oprogramowania CFD w celu zbadania wpływu zmian parametrów strukturalnych wężownicy spiralnej (kąt zbieżności, skok i promień bazowy krzywizny zmieniały się, podczas gdy wysokość pozostawała stała) na liczbę Nusselta, współczynnik wymiany ciepła i temperaturę na wyjściu wężownicy. W badaniach wykorzystano sześć głównych wężownic, o średnicach rury 10 i 12,5 mm i promieniach bazowych krzywizny 70, 80 i 90 mm. W wyniku badań stwierdzono, że zarówno liczba Nusselta jak współczynnik wymiany ciepła rosną wraz ze wzrostem kąta zbieżności. Stwierdzono również, że przy różnych kątach zbieżności skok spirali ma wpływ na liczbę Nusselta i współczynnik wymiany ciepła. Opracowano program w środowisku MATLAB przy pomocy którego obliczono liczby Nusselta dla każdego zwoju wężownicy; na tej podstawie obliczono następnie wartość średnią liczby Nusselta dla całej wężownicy. Program obliczeniowy był oparty na równaniu empirycznym Manlapaza i Churchilla dla zwykłych wężownic spiralnych. Wyniki symulacji uzyskane przy użyciu oprogramowania CFD okazały się możliwe do przyjęcia w zestawieniu z wynikami obliczeń w programie MATLAB.
Źródło:
Archive of Mechanical Engineering; 2012, LIX, 3; 361-375
0004-0738
Pojawia się w:
Archive of Mechanical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Computer simulation of temperature distribution on a solid target for 201Tl production
Autorzy:
Aboudzadeh Rovais, M. R.
Yousefi, K.
Ardaneh, K.
Mirzaii, M.
Powiązania:
https://bibliotekanauki.pl/articles/147613.pdf
Data publikacji:
2011
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
heat transfer
computer simulation
solid target
thallium-201
Opis:
Thallium-201 is of great interest in nuclear medicine for diagnostic purposes. It is produced by the 203Tl(p,3n)201Pb nuclear reaction. Since the target for 201Tl production is a solid target and the maximum beam current for the irradiation has a direct relation with its temperature surface, therefore, the control of temperature during the irradiation is essential. Designing a proper cooling system is one of the important and determining parameters in radionuclide production efficiency. Non-controlled temperature would cause melting and consequently loss of target materials that could be very costly especially when an isotopically enriched material is used. In this study, the heat transfer and temperature distribution on the target has been simulated based on a computational fluid dynamics (CDF) code for the thermal behavior of the target during the irradiation and under the different beam currents, cooling flow rates and target designing. The results on the routinely used target for the production of 201Tl in AMIRS, showed that there was a good linearity between proton beam currents (in the range of 100–350 mi A) and maximum temperature on the thallium target (345–458 K). The results also showed that the flow rate of the cooling water can be brought down (from routinely used 45 L/min) to 15 L/min without any risk of melting of target material.
Źródło:
Nukleonika; 2011, 56, 4; 283-289
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Application of the similarity theory in model investigations of a ships fluidized bed boiler
Zastosowanie teorii podobieństwa w badaniach modelowych okrętowego kotła fluidalnego
Autorzy:
Adamkiewicz, A.
Zeńczak, W.
Powiązania:
https://bibliotekanauki.pl/articles/359479.pdf
Data publikacji:
2010
Wydawca:
Akademia Morska w Szczecinie. Wydawnictwo AMSz
Tematy:
teoria podobieństwa
współczynnik przejmowanie ciepła
warstwa fluidalna
kocioł okrętowy
theory of similarity
heat transfer coefficient
fluidized bed
ship boiler
Opis:
In model investigation of ship's fluidised bed boiler the similarity theory has been applied, which permits to transfer the investigation results from the model to the real object. For setting the non- dimensional numbers in similar phenomena, the analysis of differential equations describing the examined phenomenon or the dimensional analysis is applied. The article presents an example of the search for the non-dimensional numbers characterising the phenomenon of heat exchange in ship's fluidised bed boiler.
W badaniach modelowych okrętowego kotła fluidalnego wykorzystano teorię podobieństwa pozwalającą na przenoszenie wyników badań z modelu na obiekt rzeczywisty. Dla ustalenia modułów bezwymiarowych w zjawiskach podobnych stosuje się analizę równań różniczkowych, opisujących rozpatrywane zjawisko lub też analizę wymiarową. W artykule przedstawiono przykład poszukiwania modułów bezwymiarowych charakteryzujących zjawisko wymiany ciepła w okrętowym kotle fluidalnym.
Źródło:
Zeszyty Naukowe Akademii Morskiej w Szczecinie; 2010, 23 (95); 5-9
1733-8670
2392-0378
Pojawia się w:
Zeszyty Naukowe Akademii Morskiej w Szczecinie
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Method of estimation of heat transfer coefficient between the fluidized bed and the surface immersed in it on an experimental simulation stand of a ship boiler
Metoda określania współczynnika przejmowania ciepła pomiędzy warstwą fluidalną a powierzchnią w niej zanurzoną na eksperymentalnym stoisku symulacyjnym kotła okrętowego
Autorzy:
Adamkiewicz, A.
Zeńczak, W.
Powiązania:
https://bibliotekanauki.pl/articles/359216.pdf
Data publikacji:
2010
Wydawca:
Akademia Morska w Szczecinie. Wydawnictwo AMSz
Tematy:
współczynnik przejmowania ciepła
warstwa fluidalna
eksperyment
kocioł okrętowy
heat transfer coefficient
fluidized bed
ship boiler
Opis:
The paper defines the meaning of local and average heat transfer coefficient. The most frequently applied experimental methods for its estimation, particularly between the fluidized bed and the surface immersed in it, are presented. The method for the estimation of the influence of position and movement of fluidizing column on heat transfer coefficient is proposed.
W artykule zdefiniowano pojęcie lokalnego i średniego współczynnika przejmowania ciepła. Przedstawiono najczęściej stosowane eksperymentalne metody jego wyznaczania, w szczególności między warstwą fluidalną i zanurzoną w niej powierzchnią, również na tle własnej metody. Zaproponowano sposób określenia wpływu położenia kolumny fluidyzacyjnej, jak i jej ruchu na wartości współczynników przejmowania ciepła.
Źródło:
Zeszyty Naukowe Akademii Morskiej w Szczecinie; 2010, 21 (93); 12-19
1733-8670
2392-0378
Pojawia się w:
Zeszyty Naukowe Akademii Morskiej w Szczecinie
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analyzing temperature changes in the ground massif with a horizontal heat exchanger in the course of the heating season
Autorzy:
Adamovsky, R.
Neuberger, P.
Sed'ova, M.
Powiązania:
https://bibliotekanauki.pl/articles/62442.pdf
Data publikacji:
2010
Wydawca:
Polska Akademia Nauk. Stowarzyszenie Infrastruktura i Ekologia Terenów Wiejskich PAN
Tematy:
temperature change
ground massif
horizontal heat exchanger
heating season
heat pump
ground source heat pump
heat transfer
energy potential
ground temperature
temperature distribution
Opis:
The article is devoted to temperature changes in the ground massif with the horizontal heat exchanger as an energy source for a heat pump. The article was aimed at analyzing temperature changes in the ground massif with the horizontal heat exchanger at the beginning, in the course of and at the end of the heating season. Another aim was to analyze temperature differences in the area of the horizontal exchanger and the reference lot. The heat flow utilized in the evaporator of heat pump was extracted from the ground exchanger (nominal output at the condenser was 10.5 kW). Temperatures of the ground massif with the horizontal heat exchanger were measured in its plane in depths of 0.75 m, 0.5 m and 0.25 m. The temperature inside the ground massif on the reference lot and ambient parameters were measured as well. It is obvious that the difference of energetic potentials inside the ground massif with the heat exchanger and on the reference lot is insignificant at the beginning of the heating season. During the heating season, the difference of ground massif energetic potentials increases; at the end it is constant. The difference of temperatures in horizontal planes was not significant at the beginning of the heating season; however, it gradually increased. Maximum differences were detected in the area of the heat exchanger. In higher strata, the difference between temperatures decreases. During a major part of the heating season, temperatures at pipes of the ground exchanger were negative. This fact affected amounts of heat extracted from the ground massif.
Źródło:
Infrastruktura i Ekologia Terenów Wiejskich; 2010, 11
1732-5587
Pojawia się w:
Infrastruktura i Ekologia Terenów Wiejskich
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Temperature changes in heat pump horizontal ground source
Autorzy:
Adamovsky, R.
Neuberger, P.
Sed'ova, M.
Powiązania:
https://bibliotekanauki.pl/articles/60337.pdf
Data publikacji:
2009
Wydawca:
Polska Akademia Nauk. Stowarzyszenie Infrastruktura i Ekologia Terenów Wiejskich PAN
Tematy:
temperature change
heat pump
ground massif
horizontal heat exchanger
heat potential
soil
thermal potential
heating period
ground temperature
temperature distribution
heat transfer
energy conservation
Opis:
The paper deals with assessment of thermal fields and temperature changes in ground massif with horizontal heat exchanger used as a heat source for a heat pump. Temperatures in the zone of the horizontal ground exchanger are compared with temperatures in a reference land. Changes of heat potential of the soil during the heating period are also assessed. Possibilities of recovery of thermal potential of the ground massif when utilizing vertical and horizontal exchangers are analyzed in the opening part of the paper. The results of the first verification indicated that average temperatures in the horizontal planes of the ground massif did not differ considerably with distance from the exchanger tube. Differences in average temperatures in reference and experimental lands confirmed sufficient heat potential of the ground massif even at the peak of the heating period. The differences in average temperatures reached up to 6.51 K in the end of the heating period while at the beginning of the heating period, the differences in average temperatures dropped to 1.35 K. The differences between maximum and minimum temperatures in the zone of the ground exchanger reached up to 1.9 K at the peak of the heating period and rose to 3.9 K at the beginning and end of the heating period. The first results of our measurements indicate the necessity of accumulation of thermal energy in the soil massif in the summer period like in case of the vertical exchangers.
Źródło:
Infrastruktura i Ekologia Terenów Wiejskich; 2009, 07
1732-5587
Pojawia się w:
Infrastruktura i Ekologia Terenów Wiejskich
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Thermal performance evaluation of an earth-to-air heat exchanger for the heating mode applications using an experimental test rig
Autorzy:
Ahmad, Saif Nawaz
Prakash, Om
Powiązania:
https://bibliotekanauki.pl/articles/2091363.pdf
Data publikacji:
2022
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
heat transfer
earth-to-air heat exchanger
ground heat exchanger
geothermal energy
renewable energy
assive heating
assive cooling
effectiveness
Opis:
This paper presents the experimental investigation of an earth-to-air heat exchanger for heating purposes in the Patna region of India, using an experimental test rig. In the view of the author, real field experiments have several limitations such as lack of repeatability and uncontrolled conditions. It also takes more time for the response of parameters that depends on nature and climate. Moreover, earth-to-air heat exchangers may be expensive to fabricate and require more land area. Thus, in this work authors executed their experimental work in indoor controllable environments to investigate the thermal performance of an earth-to-air heat exchanger. The actual soil conditions were created and maintained the temperature at 26°C throughout the soil in the vicinity of pipes. Three horizontal PVC pipes of equal lengths and diameters of 0.0285 m, 0.038 m and 0.0485 m were installed in the test rig. The experiments were performed for different inlet air velocities at ambient air temperature. This study acknowledges that the maximum rise in outlet temperature occurs at a lower speed for smaller pipes. Also, the maximum effectiveness of 0.83 was observed at 2 m/s for the smallest diameter pipe.
Źródło:
Archives of Thermodynamics; 2022, 43, 1; 185--207
1231-0956
2083-6023
Pojawia się w:
Archives of Thermodynamics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Modeling of heat and mass transfer in LaNi5 matrix during hydrogen absorption-desorption cycle
Autorzy:
Akanji, O. L.
Kolesnikov, A. V.
Powiązania:
https://bibliotekanauki.pl/articles/779125.pdf
Data publikacji:
2012
Wydawca:
Zachodniopomorski Uniwersytet Technologiczny w Szczecinie. Wydawnictwo Uczelniane ZUT w Szczecinie
Tematy:
packed bed
reactor
stress
metal hydride
hydrogen
structural mechanics
heat transfer
mass transfer
Opis:
Packed bed reactors using metal hydride are attracting a lot of attention as potential hydrogen storage systems. Some operational and design variables are major constraints to obtain a proper infl ow/outfl ow of hydrogen into a metal hydride reactor. These variables include packed bed thermal conductivity, porosity, pressure and temperature distributions in the reactor during the absorption/desorption cycle. They also cause a mechanical stress induced by temperature gradient. In this paper, two dimensional models are implemented in COMSOL multiphysics to simulate the hydrogen fl ow, pressure and temperature distributions in the packed bed reactor during absorption/desorption cycle. Also, stresses in porous metal hydride induced by temperature variation in the heating/cooling cycle were evaluated. A possible effect of stress induced, porosity changes on diffusion and heating of hydrogen in both radial and axial direction in packed bed is discussed. The model consists of a system of partial differential equations (PDE) describing structural mechanics of stress, heat and mass transfer of hydrogen in the porous matrix of the packed bed reactor.
Źródło:
Polish Journal of Chemical Technology; 2012, 14, 3; 71-76
1509-8117
1899-4741
Pojawia się w:
Polish Journal of Chemical Technology
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Economic practicability of the implementation of the mine refrigeration technology for normalization of thermal conditions
Autorzy:
Alabiev, Vadim R.
Dozorov, Alexander V.
Savvateeva, Irina A.
Druzyanova, Varvara P.
Sangadzhiev, Mergen M.
Powiązania:
https://bibliotekanauki.pl/articles/220336.pdf
Data publikacji:
2020
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
chłodzenie kopalni
maszyna chłodnicza
warunki termiczne pracy
drilling galleries
heat transfer fluid
mine refrigeration technology
an underground cooling machine
working thermal conditions
economic practicability
Opis:
The purpose of this research is to substantiate a technical solution for improving the working conditions for the thermal factor in the extraction of oil by the thermoshaft method using the mine refrigeration technology. The review of manufacturers and technical characteristics of refrigeration technology in Russia, CIS countries and Western Europe was conducted. It was shown that the use of a water cooling machine in the mine air conditioning system will reduce the air temperature in the oil production gallery to the required values and will allow to abandon the long-term construction of a surface stationary refrigeration station. Normalization of the thermal regime reduces the costs of benefits and compensation for work in harmful labor conditions and improves the quality of service of production wells by operators. The practical significance is that the proposed project for the introduction of air conditioning has a high level of profitability, and its payoff will occur in the second year of operation.
Źródło:
Archives of Mining Sciences; 2020, 65, 2; 271-284
0860-7001
Pojawia się w:
Archives of Mining Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Numerical simulation of flow and heat transfer in hydromagnetic micropolar fluid between two stretchable disks with viscous dissipation effects
Autorzy:
Ali, K.
Ahmad, S.
Ashraf, M.
Powiązania:
https://bibliotekanauki.pl/articles/279778.pdf
Data publikacji:
2016
Wydawca:
Polskie Towarzystwo Mechaniki Teoretycznej i Stosowanej
Tematy:
MHD
micropolar fluid
stretchable disk
viscous dissipation
couple stress
heat transfer rate
Opis:
A study of magnetohydrodynamic (MHD) flow with viscous dissipation and heat transfer in an electrically conducting laminar steady viscous incompressible micropolar fluid between two infinite uniformly stretching disks is presented. The transformed self similar nonlinear ODEs are first linearized using a quasi linearization method and then solved by employing a combination of a direct and an iterative method. The study may be beneficial to flow and thermal control of polymeric processing.
Źródło:
Journal of Theoretical and Applied Mechanics; 2016, 54, 2; 633-643
1429-2955
Pojawia się w:
Journal of Theoretical and Applied Mechanics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Heat transfer in road pavement structure and identification of its layers thermal parameters
Wymiana ciepła w konstrukcji nawierzchni drogowej i identyfikacja parametrów materiałowych tworzących jej warstwy
Autorzy:
Aliawdin, P.
Połczyński, J.
Powiązania:
https://bibliotekanauki.pl/articles/395947.pdf
Data publikacji:
2010
Wydawca:
Uniwersytet Zielonogórski. Oficyna Wydawnicza
Tematy:
nawierzchnia drogowa
wymiana ciepła
konstrukcja nawierzchni drogowej
pavement system
heat transfer problem
boundary conditions identification
road pavement structure
Opis:
A heat transfer problem for the road pavement system "layered plate - embankment - soil base" is formulated. There are suggested mathematical models and their realization with the use of finite element analysis and design software program by solving the layered plate on the ground foundation. Transient thermal state for this road structure is defined by discretization of the system described by different material properties. The theoretical results are compared with the experiment data for the real road pavement of Lubuski province road No 297 on the route Zagan-Kozuchow in Poland. Finally, two inverse problems are formulated, to identify respectively the boundary conditions and heat material parameters of road structure by smooth (least squares) and nonsmooth (minimax) optimization. It was shown that the criterion of least squares does not give trust results and only nonsmooth criterion of minimax lead to a trust result of the identification.
W pracy przedstawiono identyfikację parametów materiałowych oraz warunków granicznych ośrodka niejednorodnego, jaki stanowi konstrukcja nawierzchni drogowej. Problem ten rozwiązano poprzez analizę wymiany ciepła dla układu "płyta wielowarstwowa - nasyp - podłoże gruntowe". Na podstawie wieloletnich badań doświadczalnych rozkładu temperatury sformułowane zostały proste i odwrotne zagadnienia nieustalonego przepływu ciepła, zrealizowane przy pomocy metody elementów skończonych. Dla identyfikacji stosowane były metody gładkiej i niegładkiej optymalizacji z kryterium najmniejszych kwadratów oraz kryterium minimaxu. Druga z metod okazała się skuteczną, ponieważ w odróżnieniu od pierwszej możliwe było wyznaczenie optymalnych wartości wszystkich badanych materiałów tworzących warstwy konstrukcji drogowej. Podane przykłady analizy numerycznej porównane zostały z wynikami badań doświadczalnych uzyskanych z poligonów zlokalizowanych na drodze wojewódzkiej nr 296 w miejscowości Kożuchów w Polsce.
Źródło:
Civil and Environmental Engineering Reports; 2010, 5; 63-78
2080-5187
2450-8594
Pojawia się w:
Civil and Environmental Engineering Reports
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Theoretical and experimental analysis of heat transfer in the layers of road pavement
Analiza teoretyczna i badania doświadczalne wymiany ciepła w warstwach jezdni drogowej
Autorzy:
Aliawdin, P.
Marcinowski, J.
Wilk, P.
Powiązania:
https://bibliotekanauki.pl/articles/396424.pdf
Data publikacji:
2005
Wydawca:
Uniwersytet Zielonogórski. Oficyna Wydawnicza
Tematy:
nawierzchnia drogowa
droga wojewódzka
wymiana ciepła
model matematyczny
road pavement system
embankment
heat transfer problem
mathematical models
experimental and numerical results
Opis:
A heat transfer problem for the road pavement system "layered plate - embankment - soil base" is formulated. There are suggested mathematical models in this work; they are realized with finite element analysis and design software COSMOS/M by solving layer plate on the ground foundation. Transient thermal state for this road structure is defined in numerical analysis by discretization of the system "layered plate – embankment – soil base" with triangular finite elements described by different material properties. The numerical results are compared with the experiment data for the real road pavement of Lubuski province road No 297 on the route Zagan-Kozuchow in Poland.
W pracy został przedstawiony problem wymiany ciepła w nawierzchni drogowej jako w układzie "płyta wielowarstwowa - nasyp - podłoże gruntowe". Podano matematyczne modele zagadnienia, które zostały rozwiazane przy pomocy metody elementów skończonych za pośrednictwem oprogramowania COSMOS/M. Stan termiczny danej konstrukcji drogowej dla nieustalonego przewodzenia ciepła został zdefiniowany w rozwiazaniach numerycznych poprzez dyskretyzacje układu "płyta wielowarstwowa - nasyp - podłoże gruntowe" z trójkatnymi elementami skończonymi opisanymi przez różne właściwosci termiczne materiałów. Obliczenia numeryczne zostały porównane z danymi zmierzonymi w przekroju drogi wojewódzkiej nr 297 na odcinku Żagań-Kożuchów województwa lubuskiego.
Źródło:
Civil and Environmental Engineering Reports; 2005, 1; 7-18
2080-5187
2450-8594
Pojawia się w:
Civil and Environmental Engineering Reports
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Performance Analysis of a Thermoelectric Cooler Placed between Two Thermoelectric Generators for Different Heat Transfer Conditions
Autorzy:
Alsaqoor, Sameh
Powiązania:
https://bibliotekanauki.pl/articles/24201669.pdf
Data publikacji:
2023
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
thermoelectric cooler
sandwich TEC
TEG performance
thermoelectric generator
heat transfer conditions
enhancing power generation
low energy harvesting
renewable energy induction
Opis:
The thermoelectric cooler (TEC) and thermoelectric generator (TEG) modules have several appealing features, including fixed parts, high reliability, low maintenance costs, and seamless connection with other heating equipment, accompaniment, can be powered by a variety of low-energy renewable energy sources such as solar water/air collectors, ground heat exchangers or heat from biomass. The thermoelectric assembly was integrated into the TEC using the TEG in this study. A prototype was developed in which recently developed thermoelectric modules were integrated into a thermoelectric cooler. For this purpose, a TEC sandwiched between two TEGs with different heat transfer conditions was established, to simulate the heat transfer and thermoelectric behavior of both the TEG and the TEC system, and evaluate the effect of the combined TEG-TEC on the performance parameters of the good system by comparing different cooling modes ranging from natural convection, forced convection, and water-cooling tests. It was shown that to the natural convection of heat transfer, as the TEC voltage increases, the hot surface temperature of the upper TEG increases, and the cold surface temperature of the lower TEG decreases, where the lowest TEC temperature reaches 1.36 A. When using forced convection (by using a fan), the temperature profile decreases over time, starting at around 70 °C for 7V, and after almost 60 minutes, the temperature drops to around 45 °C for 3V. This turned out to be a match between experiment and theory in all traces shown, with a voltage difference of 25 mV for 3V TEC and ending at 70 mV for 8V TEC.
Źródło:
Journal of Ecological Engineering; 2023, 24, 4; 27--35
2299-8993
Pojawia się w:
Journal of Ecological Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
A numerical method for viscous flow in a driven cavity with heat and concentration sources placed on its side wall
Autorzy:
Ambethkar, V.
Basumatary, L. R.
Powiązania:
https://bibliotekanauki.pl/articles/122794.pdf
Data publikacji:
2018
Wydawca:
Politechnika Częstochowska. Wydawnictwo Politechniki Częstochowskiej
Tematy:
numerical method
viscous flow
heat source
concentration source
driven square cavity
general algorithm
stability conditions
isotherms
streamlines
geometric center
heat and mass transfer
metoda numeryczna
lepki przepływ
źródło ciepła
warunki stabilności
izotermy
transfer ciepła
transfer masy
Opis:
This paper proposes a method to numerically study viscous incompressible two-dimensional steady flow in a driven square cavity with heat and concentration sources placed on its side wall. The method proposed here is based on streamfunction-vorticity (Ψ-ξ) formulation. We have modified this formulation in such a way that it suits to solve the continuity, x and y-momentum, energy and mass transfer equations which are the governing equations of the problem under investigation in this study. No-slip and slip wall boundary conditions for velocity, temperature and concentration are defined on walls of a driven square cavity. In order to numerically compute the streamfunction Ψ, vorticityfunction ξ , temperature θ, concentration C and pressure P at different low, moderate and high Reynolds numbers, a general algorithm was proposed. The sequence of steps involved in this general algorithm are executed in a computer code, developed and run in a C compiler. We propose that, with the help of this code, one can easily compute the numerical solutions of the flow variables such as velocity, pressure, temperature, concentration, streamfunction, vorticityfunction and thereby depict and analyze streamlines, vortex lines, isotherms and isobars, in the driven square cavity for low, moderate and high Reynolds numbers. We have chosen suitable Prandtl and Schmidt numbers that enables us to define the average Nusselt and Sherwood numbers to study the heat ad mass transfer rates from the left wall of the cavity. The stability criterion of the numerical method used for solving the Poisson, vorticity transportation, energy and mass transfer has been given. Based on this criterion, we ought to choose appropriate time and space steps in numerical computations and thereby, we may obtain the desired accurate numerical solutions. The nature of the steady state solutions of the flow variables along the horizontal and vertical lines through the geometric center of the square cavity has been discussed and analyzed. To check the validity of the computer code used and corresponding numerical solutions of the flow variables obtained from this study, we have to compare these with established steady state solutions existing in the literature and they have to be found in good agreement.
Źródło:
Journal of Applied Mathematics and Computational Mechanics; 2018, 17, 3; 17-30
2299-9965
Pojawia się w:
Journal of Applied Mathematics and Computational Mechanics
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies