Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "Heat Recovery" wg kryterium: Temat


Tytuł:
Alignment of the heat recovery potential with the local area heat demand for selected industrial entities in the city of Gliwice
Autorzy:
Banasik, Aleksandra
Kostowski, Wojciech
Powiązania:
https://bibliotekanauki.pl/articles/41185413.pdf
Data publikacji:
2023
Wydawca:
Politechnika Warszawska, Instytut Techniki Cieplnej
Tematy:
waste heat
heat recovery
district heating system
residential sector
energy management
strata ciepła
odzysk ciepła
system ciepłowniczy
sektor mieszkaniowy
zarządzanie energią
Opis:
Waste heat plays a significant role in obtaining the 4th and 5th generation of District Heating (DH) System in cities. This article presents the possibilities of integrating selected waste heat emitters into DH, with the objective of meeting the demand for heat for the selected residential area (approx. 4000 inhabitants) in the city of Gliwice (180 000 inhabitants). The total heating demand of the studied area was estimated at 19 800 GJ including both space heating and domestic hot water. The maximum thermal power was estimated at approx. 2.45 MW. The demand was calculated on the basis of registered metering values for individual buildings which were processed and summarized due to the lack of collective meters for the district. A detailed data classification, correction and completion procedure was elaborated to deal with non-uniform and low-quality data registration. Two industrial objects with waste heat generation were examined to be integrated with the local DH network. The waste heat generation potential equals 9.0 MW for plant #1 and 0.9 MW for plant #2. Apart from the constant generation declared by the industrial entities, realistic profiles including possible shaft-work and maintenance periods were created. It has been shown that the total heat demand for selected residential areas can be covered by integrating waste heat into the current DH network. Depending on the waste heat generation profile, the local area heat demand can be covered entirely or to a large degree (coverage factor ranges from 72 to 100%). The waste heat utilization factor ranges from 6.3 to 8.3%. To manage the remaining waste heat potential, it is required to build additional district heating pipelines and nodes connecting to the existing network to receive an additional 7.45 MW thermal power. The potential of waste heat recovery is significant at the scale of a medium sized city: integrating two large industrial emitters allows up to 13% decarbonization of heats production in the local district heating plan.
Źródło:
Journal of Power Technologies; 2023, 103, 2; 104-117
1425-1353
Pojawia się w:
Journal of Power Technologies
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Assessing the financial benefits of using a shower drain heat recovery system - a case study
Ocena korzyści finansowych z wykorzystania instalacji odzyskiwania ciepła z odpływu spod prysznica - studium przypadku
Autorzy:
Janaszek, Agata
Kowalik, Robert
Powiązania:
https://bibliotekanauki.pl/articles/27314911.pdf
Data publikacji:
2023
Wydawca:
Politechnika Świętokrzyska w Kielcach. Wydawnictwo PŚw
Tematy:
wastewater heat recovery
grey wastewater
heat exchangers
odzysk ciepła ze ścieków
ścieki szare
wymienniki cieplne
Opis:
The production of hot water for bathing in Poland accounts for around 15% of the total energy consumption of a typical household. According to EU data, final energy consumption for lighting and appliances is similar to final energy consumption for hot water preparation. This makes it a significant contributor to housing and utility costs, exceeded only by heating expenses. Research has indicated that only about 10% of the water utilized during a shower is necessary for hygiene purposes. Consequently, around 90% of the hot water supplied to the shower is ultimately discharged into the sewage system. By harnessing the primary energy from wastewater, we can effectively conserve heat energy and reduce the overall expenditure associated with hot water. The objective of this article is to explore the utilization of heat recovery from domestic wastewater as a means to enhance the energy efficiency of residential buildings.
Wytwarzanie ciepłej wody w Polsce do kąpieli stanowi około 15% całkowitego zużycia energii w typowym gospodarstwie domowym. Według danych UE, końcowe zużycie energii na oświetlenie i urządzenia jest zbliżone do końcowego zużycia energii na przygotowanie ciepłej wody użytkowej. To sprawia, że jest to znaczący czynnik wpływający na koszty mieszkaniowe i użytkowe, przewyższany jedynie przez wydatki na ogrzewanie. Badania wykazały, że tylko około 10% wody zużywanej podczas kąpieli pod prysznicem jest niezbędna do celów higienicznych. W rezultacie około 90% ciepłej wody dostarczanej do prysznica jest ostatecznie odprowadzane do kanalizacji. Wykorzystując energię pierwotną ze ścieków, możemy skutecznie oszczędzać energię cieplną i zmniejszyć ogólne wydatki na ciepłą wodę. Celem tego artykułu jest zbadanie wykorzystania odzysku ciepła ze ścieków domowych jako sposobu na zwiększenie efektywności energetycznej budynków mieszkalnych.
Źródło:
Structure and Environment; 2023, 15, 3; 168--172
2081-1500
Pojawia się w:
Structure and Environment
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Exploration of a model thermoacoustic turbogenerator with a bidirectional turbine
Autorzy:
Korobko, Volodymyr
Serbin, Serhiy
Le, Huu Cuong
Powiązania:
https://bibliotekanauki.pl/articles/34604689.pdf
Data publikacji:
2023
Wydawca:
Politechnika Gdańska. Wydział Inżynierii Mechanicznej i Okrętownictwa
Tematy:
waste heat recovery
ship power plant
thermoacoustics
thermoacoustic engine
bidirectional turbine
Opis:
The utilisation of the thermal emissions of modern ship power plants requires the development and implementation of essentially new methods of using low-temperature waste heat. Thermoacoustic technologies are able to effectively use lowtemperature and cryogenic heat resources with a potential difference of 500–111 K. Thermoacoustic heat machines (TAHMs) are characterised by high reliability, simplicity and environmental safety. The wide implementation of thermoacoustic energy-saving systems is hampered by the low specific power and the difficulties of directly producing mechanical work. An efficient approach to converting acoustic energy into mechanical work entails the utilisation of axial pulse bidirectional turbines within thermoacoustic heat engines. These thermoacoustic turbogenerators represent comprehensive systems that consist of thermoacoustic primary movers with an electric generator actuated by an axial-pulse bidirectional turbine. The development of such a thermoacoustic turbogenerator requires several fundamental issues to be solved. For this purpose, a suitable experimental setup and a 3D computational fluid dynamics (CFD) model of a thermoacoustic engine (TAE) with bidirectional turbines were created. The research program involved conducting physical experiments and the CFD modelling of processes in a TAE resonator with an installed bidirectional turbine. The boundary and initial conditions for CFD calculations were based on empirical data. The adequacy of the developed numerical model was substantiated by the results of physical experiments. The CFD results showed that the most significant energy losses in bidirectional turbines are manifested in the output grid of the turbine.
Źródło:
Polish Maritime Research; 2023, 4; 102-109
1233-2585
Pojawia się w:
Polish Maritime Research
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Modular heat storage in waste heat recovery installations
Autorzy:
Górszczak, Piotr
Rywotycki, Marcin
Hojny, Marcin
Filo, Grzegorz
Powiązania:
https://bibliotekanauki.pl/articles/27312237.pdf
Data publikacji:
2023
Wydawca:
Polska Akademia Nauk. Czasopisma i Monografie PAN
Tematy:
heat storage
heat recovery
waste heat
CFD
Opis:
The paper presents the methodology of designing a system for accumulating waste heat from industrial processes. The research aimed to analyse the fluid’s movement in the heat accumulator to unify the temperature field in the volume of water constituting the heat buffer. Using the computer program Ansys Fluent, a series of computational fluid dynamics simulations of the process of charging the heat storage with water at 60◦C, 70◦C, and 80◦C was carried out. The selected temperatures correspond to the temperature range of unmanaged waste heat. In the presented solution, heat storage is loaded with water from the cooling systems of industrial equipment to store excess heat and use it at a later time. The results of numerical calculations were used to analyse the velocity and temperature fields in the selected structure of the modular heat storage. A novelty in the presented solution is the use of smaller modular heat storage units that allow any configuration of the heat storage system. This solution makes it possible to create heat storage with the required heat capacity.
Źródło:
Archives of Thermodynamics; 2023, 44, 3; 301--323
1231-0956
2083-6023
Pojawia się w:
Archives of Thermodynamics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Rekuperacja ciepła z istniejących i budowanych składowisk odpadów pogórniczych w aspekcie profilaktycznym i odzysku energii
Heat recovery from old and under construction coal waste dumps in terms of prevention and energy recovery
Autorzy:
Korski, Jacek
Powiązania:
https://bibliotekanauki.pl/chapters/2232654.pdf
Data publikacji:
2023
Wydawca:
Instytut Techniki Górniczej KOMAG
Tematy:
składowiska odpadów górniczych
odzysk ciepła
pożary składowisk odpadów
prewencja pożarowa
coal waste dumps
heat recovery
waste dump fires
fire prevention
Opis:
W rozdziale przedstawiono, w oparciu o dostępne źródła, analizy podstawowych czynników wywołujących pożary składowisk odpadów pogórniczych z kopalń węgla. Na podstawie analizy dostępnej wiedzy o przyczynach pożarów składowisk odpadów pogórniczych z kopalń węgla przedstawiono koncepcję rozwiązania technicznego łączącego w sobie funkcjonalność w zakresie prewencji pożarowej i możliwości odzysku ciepła z naturalnych procesów powodujących jego wydzielanie. Zaproponowane rozwiązanie ma charakter zintegrowany, bowiem obejmuje cykl spójnych w całym cyklu życia składowiska ciąg działań i rozwiązań technicznych, którego efektem ma być najpierw niedopuszczenie do powstania ognisk pożarowych i jednocześnie zapewnienie późniejszej możliwości wykorzystania składowiska jako źródło ciepła do lokalnego wykorzystania.
In chapter were analyzed, basing on available sources a literature and practical experiences main factors of coal mining waste dumps. O this knowledge is presented new idea of technical solution integrating functionality in waste dumps fire prevention and heat recovery from this dump in full life cycle. As first proposed solution ought to be a fire prevention and to give availability for heat recover for local use.
Źródło:
KOMEKO Konferencja Naukowo-Techniczna Przemysł Przyjazny dla Środowiska; 33-42
9788365593320
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Reliability and availability modelling of a retrofitted Diesel-based cogeneration system for heat and hot water demand of an isolated Antarctic base
Autorzy:
Coronado, Miguel
Kadoch, Benjamin
Contreras, Jorge
Kristjanpoller, Fredy
Powiązania:
https://bibliotekanauki.pl/articles/27312786.pdf
Data publikacji:
2023
Wydawca:
Polska Akademia Nauk. Polskie Naukowo-Techniczne Towarzystwo Eksploatacyjne PAN
Tematy:
reliability
availability
waste heat recovery
combined heat and power
Opis:
The reduction of greenhouse gas emissions is a relevant challenge for a sustainable development. Waste heat could be used to produce hot water by using a recovery system. This article studies the availability of a combined heat and power systems (CHP) in extreme area (Antarctic) through the integration of a waste heat recovery system with a diesel generator to produce hot water. The reliability and availability principles are incorporated to explore how the profile of hot water consumption and the hot water storage tank size affect system availability. Different combined heat and power systems are thus classified, and their availability indexes modelled by adopting the continuous Markov approach and the state space model. The results indicate that the CHP systems availability is strongly influenced by the daily hot water demand profile. As a useful recommendation, one of the considerations for increasing availability, reducing costs and greenhouse gas emissions with the CHP system is to include a hot water tank in the analysis.
Źródło:
Eksploatacja i Niezawodność; 2023, 25, 3; art. no. 169779
1507-2711
Pojawia się w:
Eksploatacja i Niezawodność
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wykorzystanie wody dołowej w odbiorze i wykorzystaniu ciepła skraplania z podziemnych układów klimatyzacji w kopalniach
Using Underground Water for Condensation Heat Rejection and Recovery in UndergroundRefrigeration Plants of Mines
Autorzy:
Szlązak, Nikodem
Obracaj, Dariusz
Korzec, Marek
Powiązania:
https://bibliotekanauki.pl/articles/28756767.pdf
Data publikacji:
2023
Wydawca:
Polskie Towarzystwo Przeróbki Kopalin
Tematy:
zagrożenie klimatyczne
klimatyzacja kopalń
agregaty chłodnicze
ciepło skraplania
wykorzystanie ciepła odpadowego
harsh climate conditions
mine cooling systems
mine refrigerant plant,
ondensation heat
waste heat recovery
Opis:
Stosowanie różnych systemów chłodzenia powietrza w kopalniach podziemnych wynika z trudnych warunków klimatycznych panujących na stanowiskach pracy. Podziemne instalacje chłodnicze z agregatami sprężarkowymi są szeroko stosowane w systemach chłodzenia powietrza. Sprawne działanie agregatów chłodniczych zależy od właściwego odprowadzania ciepła skraplania. Moc chłodnicza i lokalizacja instalacji chłodniczej mają największy wpływ na podjęcie decyzji o odprowadzeniu ciepła skraplania do powietrza lub wody. W artykule skoncentrowano się na zastosowaniu urządzeń chłodniczych zabudowanych w wyrobiskach podziemnych. Przedstawiono rozważania dotyczące ograniczeń przekazywania ciepła skraplania do powietrza kopalnianego oraz warunki sprzyjające wykorzystaniu wody dołowej w odbiorze ciepła skraplania z układów klimatyzacji. Omówiono uwarunkowania i możliwości wykorzystania ciepła odpadowego zawartego w pompowanej na powierzchnię wodzie dołowej.
Using various air cooling systems in underground mines results from harsh climatic conditions at workplaces. Underground refrigeration plants with compressor chillers are widely used in air cooling systems. The efficient operation of refrigeration units depends on the proper condensation heat rejection. Cooling capacity and localization of a refrigeration plant have the most significant influence on deciding of rejecting condensation heat to air or water. The limitation of the heat rejection capacity of return air streams in a typical mine and conditions facilitative to using underground water from an underground mine dewatering system is presented. Determinants and opportunities for heat recovery from water discharged to the surface are also discu
Źródło:
Inżynieria Mineralna; 2023, 1; 225--234
1640-4920
Pojawia się w:
Inżynieria Mineralna
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
An innovative method for waste heat recovery from flue gas treatment system through an additional economizer
Autorzy:
Iliev, Iliya Krastev
Kowalczyk, Tomasz
Beloev, Hristo Kvanov
Terziev, Angel Kostadinov
Jesionek, Krzysztof Jan
Badur, Janusz
Powiązania:
https://bibliotekanauki.pl/articles/2091368.pdf
Data publikacji:
2022
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
waste heat recovery
flue gases
feasibility study
battery emulsifier second generation
bag filters
Opis:
The usage of wet methods for flue gas dedusting from coalfired boilers is associated with significant heat losses and water resources. Widespread emulsifiers of the first and second generation are satisfactory in terms of flue gas cleaning efficiency (up to 99.5%), but at the same time do not create conditions for deeper waste heat recovery, leading to lowering the temperature of gases. Therefore, in the paper, an innovative modernization, including installing an additional economizer in front of the scrubber (emulsifier) is proposed, as part of the flue gas passes through a parallel bag filter. At the outlet of the emulsifier and the bag filter, the gases are mixed in a suitable ratio, whereby the gas mixture entering the stack does not create conditions for condensation processes in the stack.
Źródło:
Archives of Thermodynamics; 2022, 43, 2; 37--59
1231-0956
2083-6023
Pojawia się w:
Archives of Thermodynamics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wybrane rozwiązania instalacyjne w nowoczesnym proekologicznym budynku biurowym
Installation solutions in the modern ecological office building
Autorzy:
Błaszczyński, Tomasz
Wojciechowski, Michał
Powiązania:
https://bibliotekanauki.pl/articles/2055996.pdf
Data publikacji:
2022
Wydawca:
Polski Związek Inżynierów i Techników Budownictwa
Tematy:
instalacja
system wentylacji
system klimatyzacji
budynek biurowy
budynek proekologiczny
komfort klimatyczny
klasyfikacja
CAV
VAV
sufit chłodzący
odzysk ciepła
installation
office building
ventilation system
air-conditioning system
pro-ecological building
climatic comfort
classification
cooling ceiling
heat recovery
Opis:
W artykule przedstawiono nowoczesne systemy instalacyjne, ze szczególnym uwzględnieniem wentylacji i klimatyzacji. Przedstawiane systemy są najczęściej stosowanymi rozwiązaniami w budynkach proekologicznych, czyli takich, które są poddawane certyfikacji ekologicznej i muszą spełniać odpowiednie kryteria. Przedstawiono ocenę nowoczesnych systemów instalacyjnych wraz z ich klasyfikacją. Szczegółowo przedstawiono wentylacje zmienno- i stałostrumieniowe, klimatyzatory i klimakonwektory. Poruszono również niezbędny element dla budynku proekologicznego, jakim jest odzysk ciepła z systemów.
In the article modern installation systems, with particular reference to the ventilation and the air-conditioning was presented. Introduced systems are most often applied solutions in ecological buildings, which are subjected to the ecological certification and must fulfil suitable criteria. The estimation of modern installation systems together with their classification was represented. In detail was introduced ventilations with variable and constant-stream-oriented, air conditioners and fan coils. The indispensable element for the ecological building, which is the warm salvage of systems was also presented.
Źródło:
Przegląd Budowlany; 2022, 93, 1-2; 25--31
0033-2038
Pojawia się w:
Przegląd Budowlany
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analysis of Heat Recovery from Wastewater Using a Heat Pump on the Example of a Wastewater Treatment Plant in the Świętokrzyskie Voivodeship in Polish
Analiza odzysku ciepła ze ścieków przy wykorzystaniu pompy ciepła na przykładzie oczyszczalni ścieków województwa świętokrzyskiego
Autorzy:
Kowalik, Robert
Bąk-Patyna, Paulina
Powiązania:
https://bibliotekanauki.pl/articles/2055089.pdf
Data publikacji:
2021
Wydawca:
Politechnika Świętokrzyska w Kielcach. Wydawnictwo PŚw
Tematy:
heat pumps
heat recovery
waste water as a source of heat pump supply
pompy ciepła
odzysk ciepła
ścieki jako źródło zasilania pomp ciepła
Opis:
Currently, sources from which renewable energy could be generated are being sought worldwide. One of these sources could be wastewater. This article shows how heat can be recovered from wastewater, using a small wastewater treatment plant in Świętokrzyskie voivodeship as an example. It analyses the temperature of wastewater in the reactor, in the sewage system and the ambient temperature for each month. The principle of heat pump operation was presented. Then, the amount of heat energy that can be recovered from wastewater was calculated for each month.
Obecnie na całym świecie poszukuje się źródeł, z których można by wytworzyć energię odnawialną. Jednym z takich czynników mogą być ścieki. W niniejszym artykule przedstawiono, jak można odzyskać ciepło ze ścieków na przykładzie niewielkiej oczyszczalni pracującej na terenie województwa świętokrzyskiego. Dokonano analizy temperatury ścieków znajdujących się w reaktorze, w kanalizacji oraz temperatury otoczenia dla każdego miesiąca. Przedstawiono zasadę działania pomp ciepła. Następnie policzono ilość energii cieplnej, jaka może być odzyskana ze ścieków dla każdego miesiąca.
Źródło:
Structure and Environment; 2021, 13, 3; 90--95
2081-1500
Pojawia się w:
Structure and Environment
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Ekologiczne rozwiązania w magazynach
Ecological solutions in warehouses
Autorzy:
Mardeusz, Ewa
Powiązania:
https://bibliotekanauki.pl/articles/1818689.pdf
Data publikacji:
2021
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
zielona logistyka
zielony magazyn
odzysk ciepła
destratyfikator powietrza
diody elektroluminescencyjne
automatyzacja magazynu
green logistics
green warehouse
heat recovery
air destratificator
light emitting diodes
warehouse automation
Opis:
W poniższym artykule przedstawiona została koncepcja zielonej logistyki ze zwróceniem szczególnej uwagi na obszary magazynowe. Wyodrębniono podstawowe informacje z zakresu certyfikacji zielonych magazynów. Głównym celem pracy było scharakteryzowanie wybranych rozwiązań ekologicznych stosowanych we współczesnych magazynach. Wymienione zostały systemy, których działanie koncertuje się na odzysku ciepła. Ponadto opisano zalety destratyfiaktorów powietrza, diod elektroluminescencyjnych oraz automatyzacji magazynu jako skuteczne narzędzia ekologiczne.
The following paper presents the concept of green logistics with special attention to warehouse areas. Basic information on the certification of green warehouses was extracted. The main objective of the study was to characterize selected ecological solutions used in modern warehouses. The systems whose operation is based on heat recovery are mentioned. In addition, the advantages of air destratifiers, LEDs and warehouse automation as effective ecological tools are described.
Źródło:
Journal of TransLogistics; 2021, 7, 1; 9--18
2450-5870
Pojawia się w:
Journal of TransLogistics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Ekologiczne rozwiązania w magazynach
Ecological solutions in warehouses
Autorzy:
Mardeusz, Ewa
Powiązania:
https://bibliotekanauki.pl/articles/1818712.pdf
Data publikacji:
2021
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
zielona logistyka
zielony magazyn
odzysk ciepła
destratyfikator powietrza
diody elektroluminescencyjne
automatyzacja magazynu
green logistics
green warehouse
heat recovery
air destratificator
light emitting diodes
warehouse automation
Opis:
W poniższym artykule przedstawiona została koncepcja zielonej logistyki ze zwróceniem szczególnej uwagi na obszary magazynowe. Wyodrębniono podstawowe informacje z zakresu certyfikacji zielonych magazynów. Głównym celem pracy było scharakteryzowanie wybranych rozwiązań ekologicznych stosowanych we współczesnych magazynach. Wymienione zostały systemy, których działanie koncertuje się na odzysku ciepła. Ponadto opisano zalety destratyfiaktorów powietrza, diod elektroluminescencyjnych oraz automatyzacji magazynu jako skuteczne narzędzia ekologiczne.
The following paper presents the concept of green logistics with special attention to warehouse areas. Basic information on the certification of green warehouses was extracted. The main objective of the study was to characterize selected ecological solutions used in modern warehouses. The systems whose operation is based on heat recovery are mentioned. In addition, the advantages of air destratifiers, LEDs and warehouse automation as effective ecological tools are described.
Źródło:
Journal of TransLogistics; 2021, 7, 1; 9--18
2450-5870
Pojawia się w:
Journal of TransLogistics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Płytki ceramiczne. Badania mikroskopowe tekstur w odniesieniu do wytrzymałości na zginanie
Autorzy:
Gąsiński, Arkadiusz
Ducka, Agnieszka
Tymowicz-Grzyb, Paulina
Kamiński, Jacek
Powiązania:
https://bibliotekanauki.pl/articles/36105225.pdf
Data publikacji:
2021
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Ceramiki i Materiałów Budowlanych
Tematy:
wentylacja
wentylacja mechaniczna z ceramicznym odzyskiem ciepła
zmiany środowiskowe
zapylenie
stężenie CO2
komfort
ventilation
mechanical ventilation with ceramic heat recovery
environmental changes
dust
CO2 concentration
comfort
Opis:
Płytki gresowe są wytwarzane głównie z glinki kaolinowej, kwarcu i skaleni. Wiele właściwości technicznych, w tym odporność na zginanie, są związane z teksturą materiału w skali mikroskopowej. Najważniejszymi cechami są: zawartość, rozmiar i kształt różnych ziaren, w tym większych ziaren kwarcu, kryształów mullitu, fazy amorficznej bogatej w krzemionką i porowatości. Zrozumienie zależności pomiędzy mikrostrukturą a odpornością na zginanie może prowadzić do opracowania efektywniejszych metod wytwarzania cieńszych płytek o większych wymiarach.
Porcelain tiles are sintered ceramic material made mainly from ball clays, quartz and feldspars. Many technical feateurs, including bending strength, are related to the microtexture of porcelain stoneware. Most important features are content, size and shape of different grains. These include large particles of filler (quartz), mullite crystals, a silica-rich amorphous phase and porosity. The understanding of the relationship between the microstructure and the bending strength of porcelain stoneware can lead to the development the manufacturing of thinner tiles with higher dimensions.
Źródło:
Szkło i Ceramika; 2021, 72, 3; 40-43
0039-8144
Pojawia się w:
Szkło i Ceramika
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Waste Heat Recovery from Servers Using an Air to Water Heat Pump
Autorzy:
Lipiński, Seweryn
Duda, Michał
Górski, D.
Powiązania:
https://bibliotekanauki.pl/articles/2069738.pdf
Data publikacji:
2021
Wydawca:
Uniwersytet Warmińsko-Mazurski w Olsztynie
Tematy:
air-water heat pump
server cooling
waste heat
heat recovery
domestic hot water
Opis:
The analysis of advisability and profitability of using an air to water heat pump for the purpose of waste heat recovery from servers being used as cryptocurrency mining rigs, was performed. To carry out such an analysis, the cooling unit of the computing server was connected to the heat pump, and the entire system was adequately equipped with devices measuring parameters of the process. Performed experiments proves that the heat pump coefficient of performance (COP) reaches satisfactory values (i.e., an average of 4.21), what is the result of stable and high-temperature source of heat at the pump inlet (i.e., in the range of 29.9-34.1). Economic analysis shows a significant reduction in the cost of heating domestic hot water (by nearly 59-61%). The main conclusion which can be drawn from the paper, is that in a case of having a waste heat source in a form of a server or similar, it is advisable to consider the purchase of air-to-water heat pump for the purpose of domestic hot water heating.
Źródło:
Technical Sciences / University of Warmia and Mazury in Olsztyn; 2021, 24(1); 105--113
1505-4675
2083-4527
Pojawia się w:
Technical Sciences / University of Warmia and Mazury in Olsztyn
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wykorzystanie wkładów ceramicznych w systemach rekuperacji ciepła
Autorzy:
Grzebielec, Andrzej
Szelągowski, Adam
Bruzi, Krzysztof
Powiązania:
https://bibliotekanauki.pl/articles/36090959.pdf
Data publikacji:
2021
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Ceramiki i Materiałów Budowlanych
Tematy:
wentylacja
wentylacja mechaniczna z ceramicznym odzyskiem ciepła
zmiany środowiskowe
zapylenie
stężenie CO2
komfort
ventilation
mechanical ventilation with ceramic heat recovery
environmental changes
dust
CO2 concentration
comfort
Opis:
Zajęcia dydaktyczne prowadzone są w salach wykładowych zwykle dostosowanych od strony technicznej do prezentowanych treści. Zainstalowane są systemy audiowizualne i nagłaśniające. Niestety w wielu przypadkach sale lekcyjne projektuje się pod kątem klimatyzacji i wentylacji, podobnie jak pomieszczenia biurowe. W efekcie, podczas zajęć, nawet w pomieszczeniach z klimatyzacją, warunki zmieniają się na tyle niekorzystnie, że zarówno nauczyciel, jak i uczniowie odczuwają dyskomfort. W pracy przeanalizowano zmiany temperatury, stężenia CO2, stężenia PM2,5 i wilgotności względnej w pomieszczeniu, w którym zyski ciepła od ludzi i urządzeń oraz zyski wilgoci przekraczają wartości projektowe. W pracy wykorzystano bezkanałowy rekuperator Respireco o pracy cyklicznej. Najpierw sprawdzono właściwości termodynamiczne samego rekuperatora, a następnie przetestowano go w wybranej polskiej szkole podstawowej. Wyniki pokazują, że tego typu rekuperatory są w stanie zapewnić prawidłowe warunki klimatyczne w salach wykładowych. Zastosowanie wentylacji mechanicznej z wykorzystaniem rekuperatora z ceramicznym odzyskiem ciepła spowodowało, że podczas zajęć stężenie CO2 w pomieszczeniu spadło o 50%. Stężenie PM2,5 utrzymywało się na poziomie trzykrotnie niższym niż w pomieszczeniu bez wentylacji mechanicznej. Należy zatem stwierdzić, że zastosowanie wentylacji mechanicznej z rekuperacją nie tylko obniża koszty ogrzewania, ale także znacząco poprawia jakość powietrza.
Classes are conducted in lecture rooms usually technically adapted to the content presented. Audio-visual and sound systems are installed. Unfortunately, in many cases, classrooms are designed for air conditioning and ventilation, just like offices. As a result, during classes, even in air-conditioned rooms, the conditions change so badly that both the teacher and the students feel discomfort. The study analyzed changes in temperature, CO2 concentration, PM2.5 concentration and relative humidity in a room where heat gains from people and devices as well as moisture gains exceed the design values. The work uses a channelless Respireco recuperator with cyclical operation. First, the thermodynamic properties of the recuperator itself were checked, and then it was tested in a selected Polish primary school. The results show that this type of recuperator is able to provide proper climatic conditions in lecture halls. The use of mechanical ventilation with the use of a recuperator with ceramic heat recovery resulted in the reduction of CO2 concentration in the room by 50% during the classes. The concentration of PM2.5 remained three times lower than in the room without mechanical ventilation. Therefore, it should be stated that the use of mechanical ventilation with recuperation not only reduces heating costs, but also significantly improves air quality.
Źródło:
Szkło i Ceramika; 2021, 72, 2; 32-36
0039-8144
Pojawia się w:
Szkło i Ceramika
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies