Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "HYSPLIT" wg kryterium: Temat


Wyświetlanie 1-2 z 2
Tytuł:
The concentration level of PM10 in southern Poland (Katowice, Kraków, and Rzeszów) during the year 2018
Autorzy:
Qor-el-aine, Achraf
Béres, András
Géczi, Gábor
Powiązania:
https://bibliotekanauki.pl/articles/2086189.pdf
Data publikacji:
2021
Wydawca:
Państwowa Wyższa Szkoła Zawodowa w Tarnowie
Tematy:
PM10
Coal Mines
HYSPLIT trajectory frequency
analysis
Katowice
Cracow
Rzeszow
kopalnia węgla
częstotliwość trajektorii HYSPLIT
analiza
Kraków
Rzeszów
Opis:
Human health and food quality are greatly affected by the state of the ambient air. In the European Union, Poland is considered as a country that has the most polluted air. The level of PM10 concentration exceeds the EU limit value in almost all the areas of Poland, but higher concentrations are registered in the southern regions, which are considered as the coal heartlands. Katowice, Kraków, and Rzeszów are three big cities in the southern part of Poland and are surrounded by coal mining industries. High PM10 concentrations are usually registered in these three cities, especially in the winter period. In 2018, the peak PM10 daily concentration occurred in the three cities at the same period (04/03/2018 in Rzeszów, 05/03/2018 in Kraków, and 05/03/2018 in Katowice). The aim was to identify the effect of each of the 8 coal mines that exist in Poland on the level PM10 concentration for the first week and March where the highest daily PM10 concentration for the year 2018 was registered. Using HYSPLIT Frequency analysis, the results showed that 100% of the particles coming from Bełchatów, Bolesław Śmiały, Halemba, Jas-Mos, Pniówek and Marcel Coal Mines hit Katowice region, and 10% from Bogdanka. While for Kraków, it was affected by 100% of the particles that are originated from Bolesław Śmiały, Pniówek, Halemba, and Jas-Mos Coal Mines and 10% Bogdanka, Bełchatów, and Marcel Coal Mines. Moreover, Rzeszów was the least affected city by the coal mines, 10% of the particles coming from Bogdanka, Bełchatów, Jas-Mos and Marcel, Halemba, and Pniówek Coal Mines attributed to high PM10 concentration during the first week of March 2018. Katowice and Kraków are more affected by the coal mines industry, Particulate Matter particles originating from the coal mines sites contribute to the high level of PM10 concentration.
Źródło:
Science, Technology and Innovation; 2021, 14, 3; 27--34
2544-9125
Pojawia się w:
Science, Technology and Innovation
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Air quality influence of selected pollutants emitted from a fire of 300 Mg of municipal waste on ambient air quality: an example of modelling with HYSPLIT
Wpływ wybranych zanieczyszczeń powietrza wyemitowanych w pożarze 300 Mg odpadów na jakość powietrza atmosferycznego – przykład wykorzystania HYSPLIT
Autorzy:
Rogula-Kozłowska, Wioletta
Bihałowicz, Jan Stefan
Powiązania:
https://bibliotekanauki.pl/articles/24202649.pdf
Data publikacji:
2022
Wydawca:
Szkoła Główna Służby Pożarniczej
Tematy:
waste fire
environmental impact
exposure to pollutant
atmospheric dispersion
HYSPLIT
fire risk
rescue management
pożary odpadów
oddziaływanie na środowisko
ekspozycja na zanieczyszczenia
rozprzestrzenianie atmosferyczne
ryzyko pożarowe
zarządzanie akcją ratowniczą
Opis:
Reducing the amount of waste disposed of in landfills requires treatment in specialised facilities. Potential threats that can arise both in waste processing and in its storage comprise a fire hazard. Waste fires hold a significant share of the total number of the largest fires in Poland. Fires in landfills and their treatment facilities are related to air quality since during a fire a large number of various pollutants is emitted into the atmosphere in a relatively short time. The paper discusses the impact of a fire taking place at a waste treatment facility on air quality, in which 300 Mg of municipal waste was burnt. Using the HYSPLIT package, the atmospheric dispersion of 23 selected organic and inorganic pollutants was determined and then analysed in GIS software. The concentrations were compared with reference values specified in relevant legal regulations. Of the 23 substances analyzed, the concentration levels were exceeded only for 6 substances at a distance of more than half a kilometre from the fire: benzo(a)pyrene, benzene, styrene, acetaldehyde, PM10, and NO2 . The substance with the greatest range as regards the reference concentration levels was benzo(a)pyrene, a compound with a proven carcinogenic effect, which indicates the importance of reducing landfill fires in the context of public health.
Zmniejszenie ilości odpadów składowanych na wysypiskach wymaga ich przetwarzania w wyspecjalizowanych zakładach. Wśród zagrożeń, które pojawiają się zarówno w przetwarzaniu odpadów, jak i ich składowaniu, znajduje się zagrożenie pożarowe. Pożary odpadów mają znaczący udział w ogólnej liczbie największych pożarów w Polsce. Podczas pożaru duża liczba różnych zanieczyszczeń jest emitowana do atmosfery w stosunkowo krótkim czasie, w związku z czym pożary odpadów są związane z jakością powietrza atmosferycznego. W pracy omówiono wpływ pożaru w zakładzie przetwarzania odpadów na jakość powietrza, w którym spłonęło 300 Mg odpadów komunalnych. Przy wykorzystaniu pakietu HYSPLIT wyznaczono dyspersję atmosferyczną 23 wybranych zanieczyszczeń organicznych i nieorganicznych, a następnie przeanalizowano ją w oprogramowaniu GIS. Stężenia porównano z wartościami referencyjnymi określonymi w odpowiednich aktach prawnych. Spośród 23 analizowanych substancji poziomy odniesienia zostały przekroczone tylko dla 6 substancji w odległości ponad pół kilometra od ognia: benzo(a)pirenu, benzenu, styrenu, aldehydu octowego, PM10 i NO2 . Substancją o największym zakresie, jeśli chodzi o poziomy stężeń referencyjnych, był benzo(a)piren, związek o udowodnionym działaniu rakotwórczym, co wskazuje na znaczenie ograniczenia pożarów składowisk w kontekście zdrowia publicznego.
Źródło:
Zeszyty Naukowe SGSP / Szkoła Główna Służby Pożarniczej; 2022, 83; 33--43
0239-5223
2720-0779
Pojawia się w:
Zeszyty Naukowe SGSP / Szkoła Główna Służby Pożarniczej
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-2 z 2

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies