Tytuł:
Optimization of induced voltage on buried pipeline from HV power lines using grasshopper algorithm (GOA)
Autorzy:
Bouallag, Khadidja
Djekidel, Rabah
Bessedik, Sid Ahmed
Powiązania:
https://bibliotekanauki.pl/articles/1840901.pdf
Data publikacji:
2021
Wydawca:
Polska Akademia Nauk. Polskie Towarzystwo Diagnostyki Technicznej PAN
Tematy:
buried pipeline
grasshopper optimization algorithm
GOA
HV power lines
AC induced voltage
rurociąg podziemny
linie wysokich napięć
napięcie indukowane
Opis:
The buried metallic pipeline which parallels to the HV power line is subject to induced voltages from the AC currents flowing in the conductors, these voltages can affect the operating personnel, pipeline associated equipment, and the pipeline integrity. This paper analyses the induced voltage and current on the buried pipeline running parallel to HV power lines. It also presents an optimization procedure of different parameters that affect the level of the induced voltage in the pipeline during normal operating conditions. A comparison study between the proposed optimization algorithms (GOA, GE, DE and PSO) is done with a maximization of a given objective function. The simulation results establish that the GOA algorithm provides a faster convergence and better solution than the other optimization algorithms. Thus, the statistical analysis according to Friedman’s rank test confirmed the superiority of this proposed algorithm. Furthermore, the results show that the parameters optimization of the metallic pipeline is an effective approach to provide the best performance for mitigation which is generally sufficient to reduce the induced voltage experienced by the buried metallic pipeline to enforce the safety limit.
Źródło:
Diagnostyka; 2021, 22, 2; 105-115
1641-6414
2449-5220
Pojawia się w:
Diagnostyka
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Narażenia piorunowe oraz wyłączenia napowietrznych linii przesyłowych wysokiego napięcia spowodowane bezpośrednimi wyładowaniami atmosferycznymi
Lightning hazard and shut-downs of overhead hv electric power transmission lines caused by direct lightning strikes
Autorzy:
Łoboda, M.
Lenarczyk, K.
Powiązania:
https://bibliotekanauki.pl/articles/266406.pdf
Data publikacji:
2014
Wydawca:
Politechnika Gdańska. Wydział Elektrotechniki i Automatyki
Tematy:
doziemne wyładowania piorunowe
wyłączenia piorunowe linii elektroenergetycznych NN
rejestracja parametrów prądu piorunowego
system rejestracji wyładowań piorunowych LINET
CG lightning intensity
HV overhead power transmission lines
faults and shut-downs of line
lightning current
parameters
Opis:
Artykuł dotyczy korelacji między doziemnymi wyładowaniami piorunowymi a wyłączeniami napowietrznych linii przesyłowych NN w Polsce. W opracowaniu przedstawiono analizę spodziewanych częstości bezpośrednich trafień wyładowań atmosferycznych w linie przesyłowe 220 kV i 400 kV, w zależności od aktywności burzowej w różnych rejonach kraju i dla różnych konstrukcji linii. Na podstawie danych Polskich Sieci Elektroenergetycznych (PSE) opracowano statystyki wyłączeń linii przesyłowych zarejestrowane w latach 2008–2013. Dla wybranych linii 220 kV i 400 kV wykonano szczegółowe analizy określonych wyłączeń linii, porównano ich skutki z parametrami wyładowań piorunowych, a także ich lokalizacją w różnych regionach Polski. Dane o miejscu i parametrach doziemnych wyładowań atmosferycznych pochodzą z systemu rejestracji wyładowań piorunowych LINET obejmującego swym zasięgiem cały obszar Polski. Oszacowano także prawdopodobieństwo spowodowania wyłączenia linii przez bezpośrednie wyładowania piorunowe oraz wartości przepięć atmosferycznych dla wybranych przypadków wyłączeń linii 220 kV i 400 kV.
The paper is addressed to analysis of shut-downs and reclosures occurred in high voltage transmission lines caused by cloud to ground lightning discharges in Poland. The problem is focused on 220 kV and 400 kV overhead lines and lightning outages in years 2008-2013. The lightning data were recorded by lightning location system LINET while faults data of transmission lines were collected by the Polish Transmission System operator. The analysis correlates the individual lightning discharge parameters and technical characteristics of selected 220 kV and 400 kV transmission lines located in different regions of Poland, which are characterised by different intensity of cloud to ground lightning discharges. Some detailed analysis includes the probability of line shut-downs and estimation of overvoltage values for typical cases of 220 kV and 400 kV lines outages in Poland. Presented analysis are quite new in Poland methodology of lightning data application useful for improvement oh HV transmission lines lightning performance.
Źródło:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej; 2014, 39; 23-28
1425-5766
2353-1290
Pojawia się w:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Kompensacja linii kablowych 110 kV wyprowadzających moc z farm wiatrowych
Compensation of 110 kV cable lines connecting wind farms with the grid
Autorzy:
Kacejko, P.
Pijarski, P.
Adamek, S.
Powiązania:
https://bibliotekanauki.pl/articles/269192.pdf
Data publikacji:
2015
Wydawca:
Politechnika Gdańska. Wydział Elektrotechniki i Automatyki
Tematy:
kompensacja mocy biernej
farmy wiatrowe
linie kablowe WN
reactive power compensation
HV cable lines
wind farms
Opis:
W referacie omówiono problemy kompensacji mocy biernej linii kablowych 110 kV o długościach kilkudziesięciu kilometrów. Linie takie są obecnie budowane głównie w celu przyłączenia farm wiatrowych, jako konsekwencja trudności w uzyskaniu pozwoleń na budowę linii napowietrznych. Praktyczne problemy projektowe wiążą się z faktem nieokreśloności pojemności kabla i reaktancji dławika (urządzenia niestandardowe produkowane jednostkowo) oraz zmiennością napięć w miejscu przyłączenia. Stosując podejście probabilistyczne zaproponowano możliwe rozwiązania w zakresie doboru urządzeń kompensacyjnych.
Application of 110 kV cable lines with length bigger than a few kilometers, is a standard engineering practice now. These cables are used mainly by wind farm developers for connecting them to power system in PCCs (Points of Common Coupling). Because of infrastructure limitations, it is impossible to built the new overhead lines, so cables occur to be one and only solution. As it is well known, HV cables are significant sources of the reactive power. It should be controlled and coordinated with general requirements of the grid operators. Application of a shunt reactor with fixed reactance (FSR), seems to be theoretically an easy task. On the other hand variability of power system parameters (voltage in PCC, active power in WF), constructional uncertainness of cable and reactor nominal parameters, forced us to look for more flexible solutions. As the alternative, the reactor with on load tap changer (OLTC) called Variable SR can be taken into account. In the paper two alternative methods of FSR versus VSR adjustment are considered.
Źródło:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej; 2015, 42; 151-154
1425-5766
2353-1290
Pojawia się w:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-3 z 3

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies