Tytuł:
Validation process for computational model of full-scale segment for design of composite footbridge
Autorzy:
Ferenc, Tomasz
Mikulski, Tomasz
Powiązania:
https://bibliotekanauki.pl/articles/259754.pdf
Data publikacji:
2020
Wydawca:
Politechnika Gdańska. Wydział Inżynierii Mechanicznej i Okrętownictwa
Tematy:
validation
numerical modelling
sandwich structure
polymer composites
GFRP laminates
Opis:
Experimental tests and numerical simulations of a full-scale segment of a foot and cycle bridge made of polimer composites are presented in the paper. The analysed structure is made of sandwich panels, which consist of glass fibre reinforced polymer (GFRP) multi-layered laminate faces and a PET foam (obtained from recycling) core. The dimensions of the segment cross-section are the same as for the target footbridge; however, span length was reduced to 3 m. The experimental tests were conducted in a laboratory of the Faculty of Ocean Engineering and Ship Technology at Gdansk University of Technology. A single vertical force was generated by a hydraulic cylinder and was applied to the platform of the structure. The experimental tests were supported by numerical analyses performed in Femap with NX Nastran software by means of the finite element method (FEM). Results obtained in the computational model were compared with results from experiments. Thus, the numerical model was validated and the obtained conclusions were used in the next step of the design process of a composite footbridge with a span length of 14.5 m.
Źródło:
Polish Maritime Research; 2020, 2; 158-167
1233-2585
Pojawia się w:
Polish Maritime Research
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Faults Detection In Layered Composite Structures Using Wavelet Transform
Detekcja uszkodzeń w warstwowych strukturach kompozytowych z zastosowaniem transformacji falkowej
Autorzy:
Katunin, A.
Moczulski, W.
Powiązania:
https://bibliotekanauki.pl/articles/328984.pdf
Data publikacji:
2010
Wydawca:
Polska Akademia Nauk. Polskie Towarzystwo Diagnostyki Technicznej PAN
Tematy:
laminaty polimerowe
detekcja uszkodzeń
transformacja falkowa
GFRP laminates
faults detection
wavelet transform
Opis:
In the paper the authors present their results concerning measurements of frequency responses of cantilever rectangular GFRP plates with intentionally inserted faults of three different types (fiber discontinuities, delaminations and notches for simulating cracks). The preliminary research shows that classical methods of signal conditioning (e.g. FFT or STFT) often do not project changes between damaged and undamaged structures, when faults are inconsiderable. In the experiment the frequency responses of the investigated samples with and without faults were obtained by means of the impact test carried out using LMS SCADAS and TestXPress software. For the approximation in wavelet transform (WT) Morlet and Db8 wavelet functions were applied. The shapes of these functions give the best imitation of the measured signal shape obtained from the impact test. The obtained results allow to assert that the proposed methodology of faults detection in layered structures based on WT can be useful for fault diagnosis even in early damage phase, when other methods are insensitive. In the further work the authors will develop the proposed method for faults identification and localization in layered structures and investigate laminate behavior with faults and self-heating in fatigue processes.
W pracy autorzy przedstawiają wyniki pomiarów odpowiedzi częstotliwościowych jednostronnie utwierdzonych prostokątnych płyt z kompozytu polimerowego zbrojonego włóknem szklanym z celowo wprowadzonymi uszkodzeniami trzech typów (nieciągłości włókien, delaminacje i karby symulujące pęknięcia). Badania wstępne pokazują, że klasyczne metody obróbki sygnałów (jak FFT czy STFT) często nie obrazują zmian pomiędzy strukturą uszkodzoną i nieuszkodzoną, gdy uszkodzenia są nieznaczne. W eksperymencie z zastosowaniem testu impulsowego były otrzymane odpowiedzi częstotliwościowe badanych próbek przy pomocy LMS SCADAS i oprogramowania TestXPress. Do aproksymacji w transformacji falkowej użyto funkcji bazowych Morleta i Db8. Kształt tych funkcji daje najlepsze przybliżenie przebiegu wartości chwilowych zmierzonego sygnału otrzymanego z testu impulsowego. Otrzymane wyniki pozwalają stwierdzić, że zaproponowana metodologia detekcji uszkodzeń w strukturach warstwowych oparta na transformacji falkowej może być użyteczne przy diagnostyce uszkodzeń nawet we wczesnych stadiach degradacji, gdy inne metody są nieczułe. W przyszłych pracach autorzy będą rozwijać zaproponowaną metodę pod kątem identyfikacji i lokalizacji uszkodzeń w strukturach warstwowych oraz badać zachowanie laminatów z uszkodzeniami i temperaturą samowzbudną w procesach zmęczeniowych.
Źródło:
Diagnostyka; 2010, 1(53); 27-32
1641-6414
2449-5220
Pojawia się w:
Diagnostyka
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-2 z 2

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies