Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "GEM detector" wg kryterium: Temat


Wyświetlanie 1-5 z 5
Tytuł:
Into the fast tomographic postprocessing in tokamaks
Wprowadzenie do zagadnienia tomografii w algorytmach postprocessingu dla reaktorów typu tokamak
Autorzy:
Krawczyk, R.
Kolasiński, P.
Linczuk, P.
Zabołotny, W.
Poźniak, K.
Zienkiewicz, P.
Romaniuk, R.
Wojeński, A.
Kasprowicz, G.
Czarski, T.
Chernyshova, M.
Powiązania:
https://bibliotekanauki.pl/articles/408058.pdf
Data publikacji:
2017
Wydawca:
Politechnika Lubelska. Wydawnictwo Politechniki Lubelskiej
Tematy:
plasma sciences
fast tomography
GEM detector
data processing
fizyka plazmy
tomografia szybka
detektor GEM
przetwarzanie danych
Opis:
The collaboration of authors led to implementing advanced and fast systems for diagnostics of plasma content in tokamaks. During the development of systems it is planned to add new functionalities, in particular, the algorithms of tomographic reconstruction to obtain information on three dimensional distribution of plasma impurities. In the article the idea of tomographic reconstruction is introduced and issues of performance and adequate hardware selection are presented.
Wieloletnia współpraca autorów przyczyniła się do powstania zaawansowanych, szybkich mechanizmów diagnostyki składu gorącej plazmy tokamakowej. W ramach rozbudowy systemów zamierza wprowadzić się szereg nowych funkcjonalności, w tym algorytmy rekonstrukcji tomograficznej. Pozwoli to na uzyskanie informacji o przestrzennym rozkładzie nieczystości plazmy w reaktorze. Praca przedstawia koncepcję tomografii tego typu oraz przeprowadzona jest dyskusja nad zagadnieniami wydajności i doboru sprzętu.
Źródło:
Informatyka, Automatyka, Pomiary w Gospodarce i Ochronie Środowiska; 2017, 7, 3; 15-18
2083-0157
2391-6761
Pojawia się w:
Informatyka, Automatyka, Pomiary w Gospodarce i Ochronie Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Multiboard trigger link synchronization and diagnostics
Autorzy:
Wojenski, A.
Pozniak, K.
Mazon, D.
Chernyshova, M.
Powiązania:
https://bibliotekanauki.pl/articles/114174.pdf
Data publikacji:
2017
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
data quality monitoring
FPGA
GEM detector
soft X-ray plasma diagnostics
trigger distribution
measurement system
Opis:
Soft X-ray (SXR) plasma measurements are important type of diagnostics especially in tokamak facilities. Main output products are energy and topology spectra distributed in time. In case of Gas Electron Multiplier (GEM) detectors, used as radiation sensors, large number of analog readout channels must be provided. For this purpose Field-Programmable Gate Arrays (FPGAs) are used. Data quality monitoring (DQM) is important topic in case of asynchronous events registered by the measurement unit. Due to numerous FPGAs used it is necessary to provide advanced trigger synchronization between them. In the paper is proposed an algorithmic approach for the trigger link training and diagnostics. It is a key component in order to provide consistent measurement data for DQM analysis. The contents of the article covers the plasma experiments and related DQM topics. In following chapters explanation of the synchronization problem is described. The proposed algorithm will be used for trigger link synchronization and diagnostics aspects. The simulations are also discussed. Currently, the proposed ideas are at the stage of implementation and tests on real hardware. Simulation were successfully performed. Summary of the work carried out is presented at the end of the paper.
Źródło:
Measurement Automation Monitoring; 2017, 63, 6; 223-225
2450-2855
Pojawia się w:
Measurement Automation Monitoring
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Soft X-ray Diagnostic System Upgrades and Data Quality Monitoring Features for Tokamak Usage
Autorzy:
Wojenski, Andrzej
Linczuk, Paweł
Piotr, Kolasinski
Chernyshova, Maryna
Mazon, Didier
Kasprowicz, Grzegorz
Pozniak, Krzysztof T.
Gaska, Michał
Czarski, Tomasz
Krawczyk, Rafał
Powiązania:
https://bibliotekanauki.pl/articles/1844595.pdf
Data publikacji:
2021
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
data quality monitoring
FPGA
Verilog/VHDL
HDL
GEM detector
SXR plasma diagnostics
modular measurement system
data evaluation
tokamak
Opis:
The validation of the measurements quality after on-site diagnostic system installation is necessary in order to provide reliable data and output results. This topic is often neglected or not discussed in detail regarding measurement systems. In the paper recently installed system for soft X-ray measurements is described in introduction. The system is based on multichannel GEM detector and the data is collected and sent in special format to PC unit for further postprocessing. The unique feature of the system is the ability to compute final data based on raw data only. The raw data is selected upon algorithms by FPGA units. The FPGAs are connected to the analog frontend of the system and able to register all of the signals and collect the useful data. The interface used for data streaming is PCIe Gen2 x4 for each FPGA, therefore high throughput of the system is ensured. The paper then discusses the properties of the installation environment of the system and basic functionality mode. New features are described, both in theoretical and practical approach. New modes correspond to the data quality monitoring features implemented for the system, that provide extra information to the postprocessing stage and final algorithms. In the article is described also additional mode to perform hardware simulation of signals in a tokamak-like environment using FPGAs. The summary describes the implemented features of the data quality monitoring features and additional modes of the system.
Źródło:
International Journal of Electronics and Telecommunications; 2021, 67, 1; 109-114
2300-1933
Pojawia się w:
International Journal of Electronics and Telecommunications
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Advanced Real-time Evaluation and Data Quality Monitoring Model Integration with FPGAs for Tokamak High-performance Soft X-ray Diagnostic System
Autorzy:
Wojenski, A.
Poźniak, K.
Mazon, D.
Chernyshova, M.
Powiązania:
https://bibliotekanauki.pl/articles/227260.pdf
Data publikacji:
2018
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
data quality monitoring
system modeling
FPGA
Verilog/VHDL
HDL
GEM detector
SXR plasma diagnostics
modular measurement system
data evaluation
Opis:
Based on the publications regarding new or recent measurement systems for the tokamak plasma experiments, it can be found that the monitoring and quality validation of input signals for the computation stage is done in different, often simple, ways. In the paper is described the unique approach to implement the novel evaluation and data quality monitoring (EDQM) model for use in various measurement systems. The adaptation of the model is made for the GEM-based soft X-ray measurement system FPGA-based. The EDQM elements has been connected to the base firmware using PCI-E DMA real-time data streaming with minimal modification. As additional storage, on-board DDR3 memory has been used. Description of implemented elements is provided, along with designed data processing tools and advanced simulation environment based on Questa software.
Źródło:
International Journal of Electronics and Telecommunications; 2018, 64, 4; 473-479
2300-1933
Pojawia się w:
International Journal of Electronics and Telecommunications
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Modern micropattern gas detectors
Autorzy:
Bochenek, M.
Koperny, S.
Kowalski, T. Z.
Powiązania:
https://bibliotekanauki.pl/articles/148102.pdf
Data publikacji:
2008
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
microstructure detector
microstrip
GEM
MICROMEGAS
capillary plate
Opis:
In all measurement systems of radiation, the detector is the most important part. We can say that it is the heart of these systems. Gas detectors are still the most popular type of detector. Modern technologies allow manufacturing gas detectors having a very good energy and position (2D) resolution, high efficiency, large effective area, small count rate effect, radiation hardness, good signal-to-noise ratio and not complicated structure. These detectors are very fast and can stably work for a long period of time. One advantage of gas detectors is the possibility to read not only charge, but also UV light generated in the detector. In this paper we want to make a review of construction, mechanical properties, performance and possible applications of the following so-called micropattern gas detectors (MPGD): microstrip gas chamber (MSGC), gas electron multiplier (GEM), MICRO-MEsh GAseous Structure (MICROMEGAS) and capillary plate detector (CP).
Źródło:
Nukleonika; 2008, 53, suppl. 2; 25-28
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-5 z 5

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies