Tytuł:
Verification of the use of GEANT4 and MCNPX Monte Carlo codes for calculations of the depth-dose distributions in water for the proton therapy of eye tumours
Autorzy:
Grządziel, M.
Konefał, A.
Zipper, W.
Pietrzak, R.
Bzymek, E.
Powiązania:
https://bibliotekanauki.pl/articles/147530.pdf
Data publikacji:
2014
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
depth-doses
GEANT4
MCNPX
therapeutic protons
Opis:
Verification of calculations of the depth-dose distributions in water, using GEANT4 (version of 4.9.3) and MCNPX (version of 2.7.0) Monte Carlo codes, was performed for the scatterer-phantom system used in the dosimetry measurements in the proton therapy of eye tumours. The simulated primary proton beam had the energy spectra distributed according to the Gauss distribution with the cut at energy greater than that related to the maximum of the spectrum. The energy spectra of the primary protons were chosen to get the possibly best agreement between the measured relative depth-dose distributions along the central-axis of the proton beam in a water phantom and that derived from the Monte Carlo calculations separately for the both tested codes. The local depth-dose differences between results from the calculations and the measurements were mostly less than 5% (the mean value of 2.1% and 3.6% for the MCNPX and GEANT4 calculations). In the case of the MCNPX calculations, the best fit to the experimental data was obtained for the spectrum with maximum at 60.8 MeV (more probable energy), FWHM of the spectrum of 0.4 MeV and the energy cut at 60.85 MeV whereas in the GEANT4 calculations more probable energy was 60.5 MeV, FWHM of 0.5 MeV, the energy cut at 60.7 MeV. Thus, one can say that the results obtained by means of the both considered Monte Carlo codes are similar but they are not the same. Therefore the agreement between the calculations and the measurements has to be verified before each application of the MCNPX and GEANT4 codes for the determination of the depth-dose curves for the therapeutic protons.
Źródło:
Nukleonika; 2014, 59, 2; 61-66
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Monte Carlo simulation of the positron implantation profiles in the layered samples
Autorzy:
Dryzek, J.
Horodek, P.
Powiązania:
https://bibliotekanauki.pl/articles/146332.pdf
Data publikacji:
2010
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
positron implantation
implantation profile
GEANT4 tool kit
Opis:
Theoretical studies of the positron implantation profiles in the layered samples are presented. Simulations performed using a GEANT4 tool kit revealed accumulation of positrons in denser layer embedded by less dens environment. This effect is significant for implantation profiles of slow positrons formed in a beam. Nevertheless, it is also present in conventional experiments, where positrons are emitted from radioactive nuclei. In some cases the diffusion process, which follows the implantation and thermalization processes, can smear this effect. However, defects on the interfaces or differences in the positron affinity can sustain it.
Źródło:
Nukleonika; 2010, 55, 1; 13-16
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
GEANT4 simulation of implantation profiles for positrons injected in solids from radioactive sources 22Na and 68Ge/68Ga
Autorzy:
Horodek, P.
Dryzek, J.
Powiązania:
https://bibliotekanauki.pl/articles/146334.pdf
Data publikacji:
2010
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
positron annihilation
implantation profile
absorption coefficient
GEANT4 tool kit
Opis:
We calculated theoretically the mass absorption coefficients for positrons emitted from the commonly used sources 22Na and 68Ge/68Ga in numerous materials. For this purpose, we used the tool kit GEANT4 which allows to generate the implantation profile. An excellent agreement between the experimental profile and the calculated one was achieved. The calculated values of the mass absorption coefficients coincide well with the experimental values determined by the DSIP method.
Źródło:
Nukleonika; 2010, 55, 1; 17-19
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-3 z 3

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies