Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "Fenton reagent" wg kryterium: Temat


Tytuł:
Treatment of Laboratory Wastewater by Using Fenton Reagent and Combination of Coagulation-Adsorption as Pretreatment
Autorzy:
Arita, Susila
Agustina, Tuty Emilia
Ilmi, Nurul
Pranajaya, Violanda Dwi Wulandari
Gayatri, Rianyza
Powiązania:
https://bibliotekanauki.pl/articles/2173343.pdf
Data publikacji:
2022
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
laboratory wastewater
fenton reagent
coagulation
adsorption
heavy metal
Opis:
Laboratory wastewater contains organic and inorganic compounds that are harmful to the environment when disposed of without prior treatment. Besides the high COD and BOD values, the laboratory wastewater also contains metals such as iron (Fe), zinc (Zn), copper (Cu), chromium (Cr), and lead (Pb) which is categorized as dangerous waste material and can pollute the groundwater. Although the quantity of wastewater produced by the laboratory is relatively small, it has a real impact on the environment around the laboratory. However, the wastewater has to be treated properly before being discharged into the environment. The aim of the research was to study the laboratory wastewater treatment by using Fenton’s reagent with coagulation and adsorption pretreatment. In the pretreatment with coagulation, three types of coagulants are used, namely PAC (Poly Aluminum Chloride), ACH (Aluminum Chlorohydrate) and Aluminum Sulfate (AS) with their respective concentrations of 10–80 ppm. The highest percentage of average pollutant removal of 58.21% was found when 80 ppm of AS was applied. The pretreatment was continued by adsorption with activated carbon and zeolite adsorbents within 60–120 minutes of mixing time. It was detected that the most optimum adsorbent was activated carbon with average pollutant removal of 50.22% within 1 hour of mixing time. Processing was extended by utilized Fenton’s reagent using a variation of the molar ratio between 1:100 and 1:400. It was obtained that the best molar ratio to degrade the laboratory wastewater is 1:300 with an average removal of pollutant of 43.45%. As a result of laboratory wastewater treatment using combine Fenton’s reagent and coagulation-adsorption pretreatment, an average pollutant removal of 90.81% was obtained. The final content of COD, BOD, TSS, as well as Cu and Pb metal has met the environmental quality standard.
Źródło:
Journal of Ecological Engineering; 2022, 23, 8; 211--221
2299-8993
Pojawia się w:
Journal of Ecological Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Influence of pH in AOP on Humic Compounds Removal from Municipal Landfill Leachate Concentrate after Reverse Osmosis
Autorzy:
Koc-Jurczyk, Justyna
Jurczyk, Łukasz
Powiązania:
https://bibliotekanauki.pl/articles/125093.pdf
Data publikacji:
2019
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
AOP
Fenton's reagent
RO retentate
landfill leachate
Opis:
The choice of the optimal method of municipal waste landfill leachate treatment should take into account such factors as: the variability of their composition and quantity over time, requirements for effluent or economic capacity. Due to the variety of compounds found in landfill leachate, it is advised to use a combination of different treatment processes. Biological methods are effective in the treatment of leachates from young landfills, but generally their efficiency declines significantly with the age of the landfill. Therefore, the physicochemical methods, i.e. advanced oxidation, adsorption, membrane methods or a combination of the mentioned, are preferred. The aim of the study was the assessment of the Fenton’s reagent utilization to process reverse osmosis concentrate of leachates collected from municipal non-hazardous waste landfill. The research was focused on the influence of pH on the process. Additionally, the effectiveness of organic compounds removal, increasing the biodegradability, as well as humic substances transformations were determined. The concentrations of humic compounds were measured by means of optical density at the wavelengths: 254, 265, 280, 320, 465 and 665 nm. In the experiment, the H2O2/Fe2+ 10: 1 ratio was tested at with a dose of H2O2 equal to 3.4 g/l (0.1 M). It was found that the pH affects the efficiency of COD removal and the increase of the biodegradability of the landfill leachate retentate, as well as the removal of humic substances and its transformation. It was found that at pH 3, the highest removal of COD occurs, with simultaneous increase in biodegradability, and decrease of absorbance caused by humic compounds.
Źródło:
Journal of Ecological Engineering; 2019, 20, 2; 161-168
2299-8993
Pojawia się w:
Journal of Ecological Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Removal of Azo Dye Acid Red 27 from Aqueous Solutions Using Classical and Modified Fenton Reagent with Zero-Valent Iron
Usuwanie barwnika azowego czerwień kwasowa 27 z roztworów wodnych przy zastosowaniu odczynnika Fentona modyfikowanego żelazem zero wartościowym
Autorzy:
Kliś, Simona
Thomas, Maciej
Barbusiński, Krzysztof
Gołombek, Klaudiusz
Krzemiński, Łukasz
Chyc, Marek
Powiązania:
https://bibliotekanauki.pl/articles/234298.pdf
Data publikacji:
2019
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Biopolimerów i Włókien Chemicznych
Tematy:
Acid Red 27
Fenton reagent
modified Fenton reagent
zero-valent iron
wastewater treatment
czerwień kwasowa 27
odczynnik Fentona
zmodyfikowany odczynnik Fentona
żelazo o zerowej wartościowości
oczyszczanie ścieków
Opis:
The article compares the classic Fenton reagent (Fe2+/H2O2) with its modification with zero-valent iron (ZVI/ H2O2) to remove azo dye Acid Red 27 from aqueous solutions at a concentration of 100 mg/L. For both methods, the most favorable parameter values were determined at which visual discoloration of the solutions tested was obtained (for Fe2+/ H2O2:pH 3.5, H2O2=60 mg/L, Fe2+/ H2O2=0.3, t=15 min, and for ZVI/ H2O2pH = 3, H2O2=40 mg/L, ZVI=80 mg/L, t=15 min). Under these conditions, the COD value was reduced by 71.5% and 69.2% for the classic Fenton and its modification, respectively. A reduction in toxicity was also obtained for Vibrio fischeri bacteria to below 25% by using the Microtox test. ZVI digestion at acidic pH for 10 minutes allowed to shorten the reaction time by about four times - from 15 to 4 minutes. BET analysis showed that the specific surface area increases with the digestion time, which significantly accelerates the reaction. The visual discoloration of aqueous solutions was obtained, and the final COD values were very small, ranging from 49-53 mg O2/L. According to the Aliivibrio fischeri toxicity classification test for water samples, all solutions of dyes tested can be considered as non-toxic (toxicity value <25%). In the study presented, results of decreasing the COD value and concentration of the dye in the ZVI/ H2O2 method obtained are slightly worse compared to the Fe2+/ H2O2method. However, taking the decolorisation time as a criterion, a four times faster decolorisation time was obtained in the ZVI/ H2O2 method, compared to the Fe2+/ H2O2 method.
W artykule porównano klasyczny odczynnik Fentona (Fe2+/H2O2) z jego modyfikacją żelazem o zerowej wartościowości (ZVI/ H2O2), w celu usunięcia barwnika azowego czerwień kwasowa 27 z wodnych roztworów, o stężeniu 100 mg/L. Dla obu metod wyznaczono najkorzystniejsze wartości parametrów, przy których uzyskano wizualne odbarwienie badanych roztworów (dla (Fe2+/H2O2): pH 3,5, H2O2=60 mg/L, Fe2+/ H2O2=0,3, t=15 min. i dla ZVI/H2O2: pH 3, H2O2=40 mg/L, ZVI=80 mg/L, t=15 min. W tych warunkach wartość ChZT spadła o 71,5% i 69,2% dla klasycznego Fentona i jego modyfikacji. Zmniejszenie toksyczności uzyskano również dla bakterii Aliivibrio fischeri (poniżej 25%) przy zastosowaniu testu Microtox. Trawienie ZVI w kwasowym pH przez 10 minut pozwoliło skrócić czas reakcji około cztery razy z 15 do 4 minut. Analiza BET wykazała, że powierzchnia właściwa wzrasta wraz z czasem trawienia, co znacznie przyspiesza reakcję. Uzyskano wizualne odbarwienie roztworów wodnych, a końcowe wartości ChZT były bardzo małe i mieściły się w zakresie 49-53 mg O2/L. Zgodnie z testem klasyfikacji toksyczności wobec Vibrio fischeri dla próbek wodnych, wszystkie testowane roztwory barwników można uznać za nietoksyczne (wartość toksyczności <25%).
Źródło:
Fibres & Textiles in Eastern Europe; 2019, 5 (137); 100-106
1230-3666
2300-7354
Pojawia się w:
Fibres & Textiles in Eastern Europe
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Zastosowanie odczynnika Fentona modyfikowanego nanożelazem do rozkładu barwników azowych (AR27 i RB5) w roztworach wodnych
Application of Fenton reagent modified with nano zero-valent iron to removal of azo dyes (AR27 and RB5) from aqueous solutions
Autorzy:
Barbusiński, K.
Kliś, S.
Thomas, M.
Kudlek, E.
Powiązania:
https://bibliotekanauki.pl/articles/237608.pdf
Data publikacji:
2018
Wydawca:
Polskie Zrzeszenie Inżynierów i Techników Sanitarnych
Tematy:
barwniki
oczyszczanie ścieków
utlenianie
rozkład
odczynnik Fentona
modyfikacja reakcji Fentona
nanożelazo
dyes
Acid Red 27
Reactive Black 5
wastewater treatment
oxidation
degradation
the Fenton reagent
modified Fenton reaction
nano zero-valent iron
Opis:
Badano skuteczność rozkładu dwóch barwników azowych (Acid Red 27 – AR27 oraz Reactive Black 5 – RB5) w roztworach wodnych o stężeniu 100 mg/dm3 poddanych działaniu odczynnika Fentona modyfikowanego nanożelazem (H2O2/nFeo). W przypadku każdego barwnika określono najkorzystniejsze wartości parametrów procesu, przy których uzyskano widoczne odbarwienie roztworu (barwnik AR27: pH=3, dawka H2O2 40 mg/dm3, dawka nFeo 60 mg/dm3, czas reakcji 15 min, barwnik RB5: pH=3, dawka H2O2 50 mg/dm3, dawka nFeo 20 mg/dm3, czas reakcji 15 min). W tych warunkach zmniejszenie wartości ChZT roztworów barwników AR27 i RB5 wynosiło odpowiednio 82,6% i 86,5, a zmniejszenie ich toksyczności (mierzonej testem Microtox) – odpowiednio 100% i 92,7%. W celach porównawczych do rozkładu barwników zastosowano także klasyczny odczynnik Fentona (H2O2/Fe2+). Widoczne odbarwienie wodnego roztworu barwnika AR27 uzyskano w tym przypadku przy pH=3,5, dawce H2O2 60 mg/dm3, stosunku [Fe2+]/[H2O2]=0,3 w czasie 15 min, a barwnika RB5 pH=3,5, dawce H2O2 40 mg/dm3, stosunku [Fe2+]/[H2O2]=0,75 w czasie 15 min. Zmniejszenie wartości ChZT roztworów AR27 i RB5 wynosiło odpowiednio 71,5% i 71,8%, a zmniejszenie ich toksyczności – 100% i 84,4%. Obie zastosowane metody utleniania, poza odbarwieniem roztworów wodnych, pozwoliły na zmniejszenie wartości ChZT roztworów barwników do 21÷49 mgO2/dm3. Zgodnie z klasyfikacją toksyczności próbek wodnych, wszystkie badane roztwory barwników z klasy próbek wysokotoksycznych (toksyczność >75%), po poddaniu ich działaniu odczynnika Fentona można uznać za nietoksyczne (toksyczność <25%).
Effectiveness of two azo dyes decomposition (Acid Red 27 – AR27 and Reactive Black 5 – RB5) with the Fenton reagent modified with nanoiron (H2O2/nFeo) was studied in aqueous solutions at a concentration of 100 mg/L. For each dye, the most favorable process parameters were determined to obtain visual discoloration of tested solutions (AR27: pH = 3, H2O2 = 40 mg/L, nFeo = 60 mg/L, t = 15 min; RB5: pH = 3, H2O2 = 50 mg/L, nFeo = 20 mg/L, t = 15 min). Under these conditions, the decrease in COD values for AR27 and RB5 was 82.6% and 86.5, respectively and in toxicity (Microtox test) – 100% and 92.7%, respectively. For comparative purposes, classic Fenton reagent (H2O2/Fe2+) was also used for the dye decomposition. For AR27, the visual discoloration of the aqueous solution was obtained within 15 min at pH = 3.5, H2O2 = 60 mg/L, [Fe2+]/[H2O2]=0.3 and for RB5 – within 15 min at pH = 3.5, H2O2 = 40 mg/L, [Fe2+]/[H2O2]=0.75. The decrease in COD values for AR27 and RB5 was 71.5% and 71.8%, respectively and in toxicity – 100% and 84.4%, respectively. Both oxidation methods applied, beside visual discoloration of the aqueous solutions, allowed for the COD reduction to the level of 21–49 mgO2/L. According to the toxicity classification for water samples, all the highly toxic samples of dye solutions tested (toxicity >75%) could be considered non-toxic (toxicity <25%) after the Fenton reagent application.
Źródło:
Ochrona Środowiska; 2018, 40, 3; 35-39
1230-6169
Pojawia się w:
Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Alternative Treatment Strategy for Different Streams of Tannery Wastewater
Autorzy:
Przywara, L.
Powiązania:
https://bibliotekanauki.pl/articles/124452.pdf
Data publikacji:
2017
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
tannery wastewater
Fenton's reagent
catalytic oxidation
COD
sulphide
Opis:
This article discusses the results of laboratory tests aimed to determine the effectiveness of tannery wastewater treatment in the process of enhanced oxidation using Fenton reagent. The general sewage from the tannery located in Mazowieckie Province was used for the research. The process was carried out using two doses of iron of 0.45 g Fe2+/dm3. and 0.56 g Fe2+/dm3, and H2O2 from 2.21 g/dm3 to 4.08 g/dm3. All the tests were performed for a constant optimum pH of 3.0. Wastewater was characterized by basic physico-chemical indicators (pH, conductivity, COD, chromium, ammonium nitrogen). The efficiency of the process was determined mainly on the basis of changes in the organic pollutants identified as COD. The efficacy of the Fenton process for different doses of Fe2+ and Fe2+ / H2O2 ratio of 1: 5, 1: 6 and 1: 7 was from 69 to 80% COD reduction in relation to raw sewage. Another aspect of the study was determining the possibility of removing sulphides from the wastewater by catalytic oxygenation with oxygen from air in the presence of manganese. In this case, the wastewater produced during leather manufacture in tanneries located in the southern part of Poland was examined. The subject of the study described in the paper was to determine the optimum manganese dose and oxidation time to simultaneously remove the sulphides and organic pollutants expressed as COD. The change in pollutant content in the wastewater over time indicates that the reduction of parameters takes place within one hour after the addition of manganese. Using the process of catalytic oxidation with 0.1 g/dm3 to 0.6 g/dm3 manganese and a reaction time of 1, 3, 24 h, the sulphides were removed in the range of 50 to 99% and organic compounds in 12 to 65%.
Źródło:
Journal of Ecological Engineering; 2017, 18, 4; 160-168
2299-8993
Pojawia się w:
Journal of Ecological Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Badania skuteczności usuwania wybranych barwników ze ścieków farbiarskich na węglu aktywnym regenerowanym reagentem Fentona
Efficacy testing of selected dye removal from textile effluents by active carbon regenerated with Fenton’s reagent
Autorzy:
Bezak-Mazur, E.
Surga, W.
Adamczyk, D.
Powiązania:
https://bibliotekanauki.pl/articles/237760.pdf
Data publikacji:
2017
Wydawca:
Polskie Zrzeszenie Inżynierów i Techników Sanitarnych
Tematy:
textile effluent
dyes
active carbon
adsorption
regeneration
Fenton's reagent
ścieki farbiarskie
barwniki
węgiel aktywny
adsorpcja
regeneracja
reagent Fentona
Opis:
The impact of Fenton’s reagent was investigated on changes in sorption capacity of the active WD-extra carbon applied to dye removal from the textile effluent. The wastewater contained three dyes, i.e. Bemacid Red NT-F, Bemacid Yellow NT-F and Bemaplex Black D-R. Adsorption jar tests demonstrated dye removal at the level of 52–62% for fresh carbon and reduced sorption capacity of carbon regenerated with Fenton’s reagent. It was established that dye removal efficacy of the five-fold reactivated material was at the level of 23–49%. Reduced sorption capacity resulted from the changes in surface structure and chemistry of the active carbon. Following successive regenerations, the active carbon was characterized by lower specific surface area, higher concentration of surface acidic groups and lower basic groups content. Loss in weight was an unfavourable phenomenon accompanying carbon reactivation that limited its fold.
Przedmiotem badań był wpływ reagenta Fentona na zmiany zdolności adsorpcyjnych węgla aktywnego WD-extra stosowanego do usuwania barwników ze ścieków farbiarskich. Badane ścieki rzeczywiste zawierały trzy barwniki, tj. Bemacid Red NT-F, Bemacid Yellow NT-F i Bemaplex Black D-R. Przeprowadzone testy adsorpcji w warunkach nieprzepływowych wykazały, że świeży węgiel usuwał barwniki ze skutecznością 52÷62%, przy czym po regeneracji reagentem Fentona jego zdolności sorpcyjne uległy zmniejszeniu. Stwierdzono, że po pięciokrotnej regeneracji węgla aktywnego analizowane barwniki były usuwane ze skutecznością 23÷49%. Zmniejszenie zdolności adsorpcyjnych wynikało ze zmiany struktury i chemizmu powierzchni węgla aktywnego. Po kolejnych regeneracjach węgiel aktywny charakteryzował się mniejszą powierzchnią właściwą oraz większą zawartością powierzchniowych grup kwasowych i mniejszą zawartością grup zasadowych. Niekorzystnym zjawiskiem towarzyszącym regeneracji węgla aktywnego był ubytek masy, ograniczający krotność jego regeneracji.
Źródło:
Ochrona Środowiska; 2017, 39, 1; 3-9
1230-6169
Pojawia się w:
Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Odbarwianie roztworów zawierających Acid Green 16 za pomocą odczynnika Fentona z nadtlenkiem wapnia
Discoloration of solutions containing Acid Green 16 using of Fentons reagent with calcium peroxide
Autorzy:
Płonka, I.
Pieczykolan, B.
Barbusiński, K.
Magiera, A.
Kocot, A.
Powiązania:
https://bibliotekanauki.pl/articles/126010.pdf
Data publikacji:
2017
Wydawca:
Towarzystwo Chemii i Inżynierii Ekologicznej
Tematy:
barwniki
odbarwianie
odczynnik Fentona
procesy pogłębionego utleniania
dye
discoloration
Fenton reagent
advanced oxidation processes
Opis:
Barwniki należą do organicznych związków chemicznych i są zbudowane z pochodnych aromatycznych benzenu, naftalenu, antracenu i związków heterocyklicznych posiadających luźno związane z cząsteczką elektrony π. Kolor zawdzięczają występowaniu podstawników, np. chromoforów. Barwnik Acid Green 16 wykorzystywany jest do celów przemysłowych. Posiada zastosowanie do barwienia drewna, jedwabiu naturalnego, wełny i skóry, a także w środkach wykorzystywanych w gospodarstwie domowym. Barwniki występujące w ściekach przemysłowych sprawiają wiele problemów ze względu na swoją toksyczność, niską podatność na biodegradację oraz intensywny kolor. Dlatego tego typu ścieki są oczyszczane z wykorzystaniem metod pogłębionego utleniania chemicznego (Advanced Oxidation Processes - AOPs), w których generowane są rodniki hydroksylowe - OH, charakteryzujące się bardzo wysoką reaktywnością w stosunku do większości zanieczyszczeń organicznych. Przeprowadzono badania nad odbarwianiem roztworu zawierającego barwnik Acid Green 16, stosując modyfikację klasycznej reakcji Fentona. W badaniach wykorzystano alternatywne źródło nadtlenku wodoru, jakim jest nadtlenek wapnia - Ixper® 75C. Dodatkowo proces był wspomagany promieniowaniem UV przy użyciu nisko- i średniociśnieniowej lampy UV. Efektywność odbarwiania oceniano na podstawie analizy stężenia barwnika Acid Green 16. W trakcie badań ustalano wpływ poszczególnych parametrów procesu: dawki nadtlenku wapnia, wartości pH, stosunku Fe2+ / Ixper® oraz czasu naświetlania. Uzyskane wyniki badań wykazały, że proces modyfikacji odczynnika Fentona umożliwił efektywne odbarwienie roztworu. W przypadku zastosowania lampy niskociśnieniowej najlepsze efekty odbarwienia otrzymano dla dawki nadtlenku wapnia wynoszącej 250 mg Ixper® 75C /dm3, stosunku Fe2+ / Ixper® wynoszącego 0,4, przy czasie naświetlania 10 minut oraz odczynie pH = 3. Wówczas w roztworze barwę zredukowano w 98,5% do poziomu 1,50 mg/dm3. Z kolei dla lampy średniociśnieniowej i najkorzystniejszych parametrów prowadzenia procesu odbarwiania obniżono stężenie barwnika w roztworze do 0,80 mg/dm3 dla dawki Ixper® 75C wynoszącej 200 mg/dm3 i uzyskano redukcję w 99,2% (stosunek Fe2+/ Ixper® = 0,4, czas naświetlania t = 10 min, pH = 2).
Dyes are organic chemicals and are made up of aromatic derivatives of benzene, naphthalene, anthracene and heterocyclic compounds having π electrons which are loosely bounded with a molecule. Dyes owe their color from occurring substituents eg. chromophores. Acid Green 16 dye is used for industrial purposes. It is intended for coloring wood, natural silk, wool and leather, as well as the means used in the household. Dyes occurring in industrial wastewater cause a lot of problems due to its toxicity, low biodegradability and intense color. For this reason, this type of wastewater is treated using the methods of advanced chemical oxidation (Advanced Oxidation Processes - AOPs) in which hydroxyl radicals are generated - OH having a very high reactivity of most of organic contaminants. Studies have been performed in order to discolor wastewater containing Acid Green 16 using a modification of the classical Fenton reaction. During the study an alternative source of hydrogen peroxide was used (calcium peroxide, which is - Ixper® 75C). Additionally, the process was assisted by UV radiation using medium and low pressure UV lamp. The efficiency of wastewater treatment was assessed by analyzing the concentration of the dye Acid Green 16. During the tests the influence of individual parameters of the process on the discoloration effectiveness was determined: the dose of calcium peroxide, pH, ratio Fe2+ / Ixper® 75C and the irradiation time. The results obtained showed that the modifications of Fenton reagent enabled effective discoloration of wastewater. In the case of the process by the low-pressure lamp the best results of discoloration obtained with a dose of calcium peroxide - Ixper® 75C 250 mg/dm3, ratio Fe2+ / Ixper® 75C equaled to 0.4, a irradiation time of 10 minutes and pH = 3. Then, the treated the concentration of Acid Green 16 in wastewater was reduced in 98.5% (up to 1.50 mg/dm3). While in the case of the medium-pressure lamp dye concentration was reduced in 99.2% (up to 0.80 mg/dm3). It was obtained when the following parameters were used: the dose of calcium peroxide of 200 mg/dm3, the ratio of Fe2+/Ixper® 75C = 0.4, t = 10 min, pH = 2.
Źródło:
Proceedings of ECOpole; 2017, 11, 1; 249-258
1898-617X
2084-4557
Pojawia się w:
Proceedings of ECOpole
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Odbarwianie roztworów zawierających Acid Green 16 za pomocą odczynnika Fentona z nadwęglanem sodu
Discoloration of solutions containing Acid Green 16 using Fentons reagent with sodium percarbonate
Autorzy:
Pieczykolan, B.
Płonka, I.
Barbusiński, K.
Jędrys, M.
Lesik, M.
Powiązania:
https://bibliotekanauki.pl/articles/127497.pdf
Data publikacji:
2017
Wydawca:
Towarzystwo Chemii i Inżynierii Ekologicznej
Tematy:
barwniki
odbarwianie
odczynnik Fentona
procesy pogłębionego utleniania
dye
discoloration
Fenton reagent
advanced oxidation processes
Opis:
W badaniach zastosowano dwie modyfikacje odczynnika Fentona z nadwęglanem sodu (jako alternatywnym źródłem H2O2) przy zastosowaniu różnego rodzaju źródła Fe2+: FeSO4·7H2O oraz wiórków stalowych. Efektywność oczyszczania roztworów oceniano na podstawie analizy stężenia barwnika Acid Green 16 (zieleń kwasowa czysta V). W trakcie badań ustalano wpływ poszczególnych parametrów zmodyfikowanego procesu Fentona (wartości pH, dawki nadwęglanu sodu, zawartości jonów żelaza pochodzących z FeSO4 oraz z wiórków stalowych, czasu reakcji przy modyfikacji z siarczanem żelaza oraz czasu kontaktu przy modyfikacji z wiórkami stalowymi) na efektywność odbarwiania. Ponadto w przypadku układu z wiórkami stalowymi określano wpływ tzw. „dodatkowego czasu reakcji”, którym jest czas, po jakim alkalizowano próbki przefiltrowanych roztworów przez złoże wypełnione wiórkami. Wynosił on „0” (filtraty alkalizowano od razu po przefiltrowaniu), 10, 20 i 30 minut. Przeprowadzone badania wykazały, że obie modyfikacje odczynnika Fentona umożliwiły efektywne odbarwienie ścieków. W przypadku układu z zastosowaniem nadwęglanu sodu i siarczanu żelaza(II) najlepsze efekty otrzymano przy dawce nadwęglanu sodu = 350 mg/dm3, stosunku Fe2+ / nadwęglanu sodu = 0,4, czasie reakcji = 15 minut oraz pH = 3. W przypadku systemu z wiórkami stalowymi wymagana dawka nadwęglanu sodu do skutecznego usunięcia barwy wynosiła 600 mg/dm3 przy czasie kontaktu z wiórkami = 39,6 sekund i dodatkowym czasie reakcji = 0 minut (roztwory alkalizowane bezpośrednio po przefiltrowaniu), pH = 2 oraz wiórków o masie = 0,5 g.
During the study two modifications Fenton reagent with sodium percarbonate (as an alternative source of H2O2) were used. There were using different kinds of sources of Fe2+ : FeSO4 and steel swarf. The efficiency of wastewater treatment was determined on the basis of the dye Acid Green 16 concentration. During the tests the influence of the individual parameters of modified Fenton process on the effectiveness of discoloration was examined (value of initial pH, dose of sodium percarbonate, the quantity of iron ions originating from FeSO4 or steel swarf, the reaction time - for modification sodium percarbonate-FeSO4 and so-called: additional reaction time for modification sodium percarbonate-steel swarf). The additional reaction time is the time after which the samples (of dye solution) filtered through the bed (filled with steel swarf) were alkalized. That time was equaled to "0" (filtrate was alkalized immediately after the filtration) 10, 20 and 30 minutes. The study showed that both modifications of Fenton reagent enabled effectively discolor the solutions. For a system with the sodium percarbonate and iron sulfate(II), the best results were obtained with a dose of sodium percarbonate = 350 mg/dm3, the ratio of Fe2+ / sodium percarbonate = 0.4, reaction time = 15 min, and pH = 3. In the case of systems with steel swarf, higher dose of sodium percarbonate was required to efficiently remove the color (600 mg/dm3), a contact time with swarf of 39.6 seconds, and additional reaction time = 0 minutes (solutions alkalized immediately after filtration), pH = 2, and quantity of swarf = 0.5 g.
Źródło:
Proceedings of ECOpole; 2017, 11, 1; 241-248
1898-617X
2084-4557
Pojawia się w:
Proceedings of ECOpole
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Optimization of the Fenton Oxidation of Synthetic Textile Wastewater Using Response Surface Methodology
Optymalizacja utleniania odczynnikiem Fentona syntetycznych ścieków z produkcji tekstyliów przy zastosowaniu metody powierzchni odpowiedzi
Autorzy:
Thomas, M.
Barbusiński, K.
Kalemba, K.
Piskorz, P. J.
Kozik, V.
Bąk, A.
Powiązania:
https://bibliotekanauki.pl/articles/234451.pdf
Data publikacji:
2017
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Biopolimerów i Włókien Chemicznych
Tematy:
textile wastewater
Fenton reagent
Response Surface Methodology
Anilan Blue
Sodium Lauryl Sulphate
ścieki tekstylne
odczynnik Fentona
metodologia powierzchni reakcji
siarczan laurylowy
Opis:
This article presents the possibility of using the classical Fenton process (Fe(II)/H2O2) to purify synthetic textile wastewater (COD=1872 mg O2/dm3, TOC=660 mg/dm3) containing azo dye Anilan Blue GRL 250% (200 mg/dm3) and Sodium Lauryl Sulphate (SLS) as anionic surfactant at a concentration of 95 mg/dm3. Model studies were carried out using RSM, obtaining a good fit of approximated values to experimental values (R2=0.9461 and R2adj=0.7379). For optimal process parameters (pH 3, Fe(II) 0.85 g/dm3, H2O2 14.5 g/dm3), complete decolourisation (3) was achieved as well as a reduction in COD, TOC and SLS concentrations to 83%, 44% and 98%, respectively.
W artykule przedstawiono możliwość zastosowania klasycznego procesu Fentona (Fe(II)/ H2O2) do oczyszczania syntetycznych ścieków tekstylnych (COD=1872 mg O2/dm3, TOC=660 mg/dm3), zawierających barwnik azowy Anilan Blue GRL 250% (200 mg/dm3) oraz surfaktant anionowy Sodium Lauryl Sulphate (SLS) o stężeniu 95 mg/dm3. Badania modelowe prowadzono z zastosowaniem RSM, otrzymując dobre dopasowanie wartości aproksymowanych do wartości doświadczalnych (R2=0.8795 oraz R2adj=0.7992). Dla optymalnych parametrów procesu (pH 3, Fe(II) 0,85 g/dm3, H2O2 14,5 g/dm3) uzyskano całkowite odbarwienie ścieków (3) oraz zmniejszenie wartości COD, TOC i stężenia SLS odpowiednio o 83%, 44% i 98%.
Źródło:
Fibres & Textiles in Eastern Europe; 2017, 6 (126); 108-113
1230-3666
2300-7354
Pojawia się w:
Fibres & Textiles in Eastern Europe
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Zastosowanie procesu Fentona do oczyszczania ścieków garbarskich
Application of Fenton’s process for treatment of tannery wastewater
Autorzy:
Przywara, L.
Powiązania:
https://bibliotekanauki.pl/articles/401972.pdf
Data publikacji:
2017
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
ścieki garbarskie
zanieczyszczenia organiczne
odczynnik Fentona
tannery wastewater
COD removal
Fenton's reagent
Opis:
W artykule omówiono badania, których celem było określenie efektywności oczyszczania ścieków garbarskich w procesie pogłębionego utleniania z zastosowaniem odczynnika Fentona. Proces przeprowadzono stosując różne dawki żelaza zmieniane w zakresie od 0,056 g Fe2+/dm3 do 0,56 g Fe2+/dm3, H2O2od 0,34 g/dm3 do 5,44 g/dm3 i w zakresie pH od 2,5 do 3,5. Ścieki scharakteryzowano wykonując oznaczenia podstawowych wskaźników fizyko-chemicznych (pH, przewodność, ChZT, chrom, azot amonowy). Badano także możliwość zastosowania procesu koagulacji przy użyciu koagulantu SAX 18. Efektywność procesu określono w oparciu o zmiany głównie wartości zanieczyszczeń organicznych określonych jako ChZT. Skuteczność procesu Fentona prowadzonego dla dawki Fe2+ na poziomie 0,56 g Fe2+/dm3i H2O2 4,08 g/ dm3 wynosiła 80% zmniejszania ChZT w stosunku do ścieków surowych i była wyraźnie wyższa niż w przypadku procesu koagulacji.
The aim of this study was to treat of tannery wastewater with the chemical advanced oxidation using Fenton reagent. Advanced oxidation process was carried out using different doses of iron (Fe2+) changes from 0.056 g Fe2+/dm3to 0.56 g Fe2+/dm3and H2O2from 0.34 g/dm3 to 5.44 g/ dm3. The wastewater samples were characterized for the concentration of chemical oxygen demand (COD), chromium, ammonia and pH, conductivity. The possibility of using the coagulation process using SAX 18 was also investigated. The efficiency of the applied processes was monitored by change mainly of chemical oxygen demand (COD). The maximum COD removal was 80% for Fenton’s oxidation process at pH 3.0, Fe2+ (0.56 g Fe2+/ dm3) and H2O2 (4.08 g/ dm3) and significantly higher than in the case of the coagulation process.
Źródło:
Inżynieria Ekologiczna; 2017, 18, 2; 117-122
2081-139X
2392-0629
Pojawia się w:
Inżynieria Ekologiczna
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Adsorption of Mixture of Two Dyes on Activated Carbon
Adsorpcja mieszaniny dwóch barwników na węglu aktywnym
Autorzy:
Bezak-Mazur, E.
Adamczyk, D.
Powiązania:
https://bibliotekanauki.pl/articles/388434.pdf
Data publikacji:
2016
Wydawca:
Towarzystwo Chemii i Inżynierii Ekologicznej
Tematy:
Dye adsorption
activated carbon
Fenton's reagent
methyl blue
naphthol green B
adsorpcja barwników
węgiel aktywny
odczynnik Fentona
błękit metylowy
zieleń naftolowa B
Opis:
Activated carbon is known as adsorbent of various contaminants from wastewater and air. The aim of the work was to estimate sorptive capacity of activated carbon in the removal of dyes, which are contaminants from textile wastewaters. The mixture of two dyes, methyl blue and naphthol green B was selected for investigations and WDex activated carbon, virgin and regenerated, was chosen as adsorbent. The dye concentration, in both cases, was 200 mg/dm3. Sorptive capacities of activated carbon were expressed as values of surface sorption, which in case of fresh activated carbon was 60 mg/g, and after regeneration – ranged from 8 mg/g to 13 mg/g. The experimental data adsorption isotherms were defined and adsorption theoretical model, such as that of Freundlich or Langmuir, was selected. The highest removal efficiency in case of methyl blue was 94% for virgin carbon, the lowest – 75% (carbon after the fourth regeneration). The highest removal efficiency in case of naphthol green B was 78% for carbon after the fourth regeneration, the lowest – 55% (carbon after the first regeneration). The experimental data show that activated carbon can be used for the decontamination of dyes from textile wastewater. Model tests, however, need to be verified on real wastewater samples.
Węgiel aktywny jest znany jako adsorbent różnych zanieczyszczeń znajdujących się w ściekach i powietrzu. W pracy podjęto próbę oceny zdolności sorpcyjnych węgla aktywnego w odniesieniu do barwników będących zanieczyszczeniami ścieków farbiarskich. Do badań wybrano mieszaninę dwóch barwników, błękitu metylowego i zieleni naftolowej B, a jako sorbent węgiel aktywny WDex świeży i regenerowany. Stężenie obu barwników wynosiło 200 mg/g. Zdolności sorpcyjne węgla świeżego wyrażone wielkością adsorpcji właściwej wyniosły 60 mg/g, a po regeneracji – od 8 mg/g do 13 mg/g. Z danych eksperymentalnych wykreślono izotermy sorpcji oraz dopasowano teoretyczny model adsorpcji tj. model Freundlicha lub Langmuira. Najwyższy procent usunięcia dla błękitu metylowego wyniósł 94% dla węgla świeżego, a najniższy – 75% (węgiel po IV regeneracji). Najwyższy procent usunięcia dla zieleni naftolowej B wyniósł 78% dla węgla po IV regeneracji, a najniższy – 55% (węgiel po I regeneracji). Uzyskane wyniki wskazują, iż zastosowany sorbent zarówno w postaci świeżej, jak i zregenerowanej może być stosowany w procesach usuwania barwników ze ścieków farbiarskich. Jednak badania modelowe muszą zostać sprawdzone na realnych próbkach ścieków.
Źródło:
Ecological Chemistry and Engineering. A; 2016, 23, 2; 161-171
1898-6188
2084-4530
Pojawia się w:
Ecological Chemistry and Engineering. A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Fenton reagent and titanium dioxide nanoparticles as antifungal agents to control leaf spot of sugar beet under field conditions
Autorzy:
Hamza, A.
El-Mogazy, S.
Derbalah, A.
Powiązania:
https://bibliotekanauki.pl/articles/65947.pdf
Data publikacji:
2016
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
Fenton's reagent
titanium dioxide
nanoparticle
antifungal agent
disease control
leaf spot
sugar-beet
field condition
toxicity
Opis:
In this study, foliar sprays of Fenton solutions (Fenton reaction, Fenton-like reaction and Fenton complex), titanium dioxide (TiO2) and the recommended fungicide (chlorothalonil) were estimated in the control of sugar beet leaf spot caused by Cercospora beticola under field conditions in two growing seasons. In addition, the impacts of these treatments on some crop characters (leaf dry weight, root fresh weight, soluble solid content, sucrose content and purity of sugar) were examined. Biochemical and histological changes in the livers and kidneys of treated rats compared to an untreated control were utilized to assess the toxicity of the examined curative agents. Overall, chlorothalonil and Fenton complex were the most effective treatments for disease suppression in both tested seasons followed by Fenton-like reagent, Fenton’s reagent and TiO2, respectively. Growth and yield characters of treated sugar beet significantly increased in comparison to an untreated control. There were mild or no (biochemical and histological) changes in the livers and kidneys of treated rats compared to the control. Fenton solutions and TiO2 may offer a new alternative for leaf spot control in sugar beet.
Źródło:
Journal of Plant Protection Research; 2016, 56, 3
1427-4345
Pojawia się w:
Journal of Plant Protection Research
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wpływ sposobu stabilizacji chemicznej na zmiany form Zn i Cu w osadach przefermentowanych
Effect of Chemical Stabilisation Method on Zn and Cu Forms in Digested Sewage Sludge
Autorzy:
Wiśniowska, E.
Włodarczyk-Makuła, M.
Nowak, R.
Powiązania:
https://bibliotekanauki.pl/articles/1818068.pdf
Data publikacji:
2016
Wydawca:
Politechnika Koszalińska. Wydawnictwo Uczelniane
Tematy:
osady ściekowe
stabilizacja
CaO
odczynnik Fentona
kwas nadoctowy
sewage sludge
stabilization
Fenton's reagent
peracetic acid
Opis:
The aim of the study was to evaluate the bioavailability of Zn and Cu in digested sewage sludge chemically stabilised with CaO, Fenton’s reagent or peracetic acid. Sewage sludge samples were taken from closed fermentation chamber of municipal wastewater treatment plant. Calcium oxide (CaO), Fenton’s reagent or peracetic acid were added into the sludge. Total reaction time was equal to 24 h. After stabilisation, total Zn and Cu content in the sludge was analysed. Speciation of chemical forms of heavy metals was also done. Speciation of heavy metals was done by modified Tessier method. Five fractions were separated. Total concentration of Zn in sewage sludge was equal to 863.5 mg Zn/kg s.m. Zn in control sludge was mainly present in fraction II (74%). Total concentration of Cu in sewage sludge was equal to 190.8 mg/kg s.m. Cu in control sludge was mainly present in fractions IV (42.5%) and II (37%). Chemical stabilisation with CaO did not cause important changes in Zn and Cu content in individual fractions. Stabilisation with Fenton’s reagent and peracetic acid decreased these metals content in fraction II (bonded with carbonates). The use of advanced oxidation processes did not release Zn and Cu from fractions IV and V.
Źródło:
Rocznik Ochrona Środowiska; 2016, Tom 18, cz. 2; 783-793
1506-218X
Pojawia się w:
Rocznik Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Zastosowanie pogłębionego utleniania odczynnikiem Fentona w połączeniu ze strippingiem powietrzem do oczyszczania ścieków pochodzących z procesu zgazowania biomasy
The application of advanced oxidation with the Fenton’s reagent and air stripping combined in the treatment of tar water from the biomass gasification
Autorzy:
Gościniak, Ł.
Powiązania:
https://bibliotekanauki.pl/articles/1208700.pdf
Data publikacji:
2016
Wydawca:
Stowarzyszenie Inżynierów i Techników Przemysłu Chemicznego. Zakład Wydawniczy CHEMPRESS-SITPChem
Tematy:
zgazowanie biomasy
ścieki
stripping
odczynnik Fentona
biomass gasification
tar water
Fenton's reagent
Opis:
Frakcja wodna, powstająca w instalacjach zgazowania stanowi złożoną mieszaninę zawierającą w swym składzie zarówno zanieczyszczenia fizyczne, jak i szereg substancji o różnej budowie chemicznej; jest uciążliwym produktem ubocznym procesu termicznego przetwórstwa biomasy. W pracy dokonano oceny możliwości zastosowania strippingu powietrzem do usuwania zanieczyszczeń z frakcji ściekowych oraz jego wpływu na skuteczność procesów pogłębionego utleniania przy zastosowaniu nadtlenku wodoru lub odczynnika Fentona.
The water fraction coming from the gasification installations, due to being a complex mixture of physical pollutions and various chemicals, remains as a burdensome by-product of the process of the biomass thermal processing. As a part of this paper, the evaluation of the possibilities of using air stripping in order to remove the pollution from the tar water fraction, as well as, its influence on the processes of advanced oxidation with the Fenton’s reagent or with hydrogen peroxide has been made.
Źródło:
Chemik; 2016, 70, 4; 209-218
0009-2886
Pojawia się w:
Chemik
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Optymalizacja warunków procesu pogłębionego utleniania odcieków składowiskowych odczynnikiem Fentona
Optimization of advanced oxidation process of the municipal landfill leachate by Fenton’s reagent
Autorzy:
Koc-Jurczyk, J.
Jurczyk, Ł.
Powiązania:
https://bibliotekanauki.pl/articles/357266.pdf
Data publikacji:
2015
Wydawca:
Politechnika Śląska
Tematy:
odcieki składowiskowe
odczynnik Fentona
temperatura
landfill leachate
Fenton's reagent
temperature
Opis:
W badaniach analizowano wpływ temperatury i proporcji reagentów chemicznych (Fe2+ i H2O2) na efektywność usuwania ChZT i zmiany proporcji BZT5/ChZT w odciekach składowiskowych pochodzących z 21-letniego składowiska odpadów komunalnych (Polska, województwo podkarpackie). Przetestowano cztery temperatury prowadzenia procesu: 30, 40, 50 i 60˚C. Badania prowadzono przy stałej dawce H2O2 – 1 g/dm3 i zmieniającej się proporcji Fe2+:H2O2: 1:3, 1:2 i 1:1. Stwierdzono, że najniższa efektywność oczyszczania odcieków zachodziła w temperaturze 40˚C niezależnie od zastosowanej proporcji reagentów chemicznych. Najbardziej efektywną okazała się proporcja Fe2+:H2O2 1:1 i temperatura 30˚C.
In this paper the influence of temperature and proportions of chemical reactants (Fe2+ i H2O2) on efficiency of COD removal and changes of BOD/COD ratios in leachate form 21 years old municipal landfill have been analyzed (Poland, Podkarpackie province). Four temperature variants: 30, 40, 50 i 60˚C. The process was conducted in constant H2O2 dose of 1 g/dm3, and variable proportions of Fe2+/H2O2: 1:3, 1:2 i 1:1. It was stated that in temperature of 40˚C treatment was most ineffective regardless of reactant doses. The most efficient conditions for examined wastewater was dose 1:1 at the temperature of 30˚C.
Źródło:
Archiwum Gospodarki Odpadami i Ochrony Środowiska; 2015, 17, 3; 1-8
1733-4381
Pojawia się w:
Archiwum Gospodarki Odpadami i Ochrony Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies