Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "Fenton reagent" wg kryterium: Temat


Tytuł:
Możliwość zastosowania odczynnika Fentona w procesach usuwania formaldehydu ze ścieków pochodzących z przemysłu drzewnego
Application of Fenton reagent in the process of formaldehyde removal from the timber industry wastewater
Autorzy:
Dębowski, M.
Zieliński, M.
Dudek, M.
Grala, A.
Powiązania:
https://bibliotekanauki.pl/articles/1819294.pdf
Data publikacji:
2012
Wydawca:
Politechnika Koszalińska. Wydawnictwo Uczelniane
Tematy:
degradation
Fenton's reagent
constant magnetic field
Opis:
The aim of this study was to determine the possibility of degradation of formaldehyde in the effluents from the timber industry with Fenton's reagent. Effluent from the timber industry are characterized by a high concentration of organic compounds and formaldehyde as an obstacle to the purification of wastewater using microorganisms and therefore an alternative to biological methods is the use of solutions based on chemical methods. In recent years, considerable attention is given to testing and implementation of the so-called advanced oxidation methods (Advanced Oxidation Processes - AOPs). A common feature of these systems is that they allow the generation of highly reactive hydroxyl radicals OH center dot with 2,8 V oxidation potential, which react with almost all organic compounds. Fast-paced distribution of impurities, versatility and high efficiency make advanced oxidation methods are now increasingly considered as a promising alternative compared to conventional methods, techniques, wastewater and sludge treatment Wastewater used in the study came from the wood of an industrial plant where the business is the manufacture of chipboard. The study was conducted in three phases with different type of chemical reactants introduced into the technological system. In the first stage reactor was dosed only iron ions Fe3+, H2O2 in the second stage, while the third part of an experiment to test the Fenton reagent treatment was introduced Fe3+ /H2O2. Each stage is divided into five variants. The criterion for division of the variants was the dose of chemical reagents. The study confirmed the applicability of advanced oxidation technologies based on Fenton's reagent in the process of degradation of formaldehyde. It was found that the efficiency of removal of contaminants from wastewater was directly connected with the dose of chemical reagents introduced into the technological system. It was also noted that increasing the dose above the Fenton reagent Fe3+ 0,3 g /l and 3,0 g H2O2/l does not significantly affect the final results of the purification process. The highest results were obtained in the technology used in doses of 0,3 g Fe 3+/l and 3,0 g H2O2 /l to 0,6 g Fe3+/l and 6,0 g H2O2/l. Limiting values of COD in the experimental variants was approximately 70,0% while the concentration of formaldehyde close to 60,0%. If dispensing the water only Fe3+ ions obtained the highest efficiency and reduce the COD concentration of formaldehyde was 28,3% sequentially and 14,5%. The final concentrations of the analyzed indicators of pollution, if only H2O2 dosing were similar to their concentrations in raw wastewater.
Źródło:
Rocznik Ochrona Środowiska; 2012, Tom 14; 587-596
1506-218X
Pojawia się w:
Rocznik Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The Efficiency of Landfill Leachate Treatment Using the Fenton’s Reagent
Autorzy:
Koc-Jurczyk, J.
Jurczyk, Ł.
Powiązania:
https://bibliotekanauki.pl/articles/124411.pdf
Data publikacji:
2015
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
wastewater treatment
landfill leachate
Fenton's reagent
Opis:
In this studies the influence of the dose and ratio of chemical reagents (Fe2+ and H2O2) on the efficiency of COD removal and changes of BOD5/COD ratio in landfill leachate was analysed. The molar Fe2+/H2O2 ratio was lower than 1 and amounted to: 1:10, 1:5, 1:3, three research series with 1; 2.5 and 5 g/L Fe2+ concentration. A higher efficiency in removing BOD than COD, and therefore the decrease of BOD5/COD ratio in effluent was stated. The efficiency of COD removal from leachate was from 58.34% (Fe2+ 0.5 g/L, Fe22+/H2O2 1:5) to 8.33% (Fe2+ = 0.1 g/L, Fe2+/H2O2 = 1:10), while the efficiency of BOD removal ranged from 62 to 77%. With the molar ratio Fe2+/H2O2 equal 1:5 the BOD5/COD ratio was the largest for each of the analysed Fe2+ doses. The lowest BOD5/COD ratio was observed for the Fe2+ dose 0.1 g/L and molar ratio of reagents 1:3.
Źródło:
Journal of Ecological Engineering; 2015, 16, 3; 70-76
2299-8993
Pojawia się w:
Journal of Ecological Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Influence of pH in AOP on Humic Compounds Removal from Municipal Landfill Leachate Concentrate after Reverse Osmosis
Autorzy:
Koc-Jurczyk, Justyna
Jurczyk, Łukasz
Powiązania:
https://bibliotekanauki.pl/articles/125093.pdf
Data publikacji:
2019
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
AOP
Fenton's reagent
RO retentate
landfill leachate
Opis:
The choice of the optimal method of municipal waste landfill leachate treatment should take into account such factors as: the variability of their composition and quantity over time, requirements for effluent or economic capacity. Due to the variety of compounds found in landfill leachate, it is advised to use a combination of different treatment processes. Biological methods are effective in the treatment of leachates from young landfills, but generally their efficiency declines significantly with the age of the landfill. Therefore, the physicochemical methods, i.e. advanced oxidation, adsorption, membrane methods or a combination of the mentioned, are preferred. The aim of the study was the assessment of the Fenton’s reagent utilization to process reverse osmosis concentrate of leachates collected from municipal non-hazardous waste landfill. The research was focused on the influence of pH on the process. Additionally, the effectiveness of organic compounds removal, increasing the biodegradability, as well as humic substances transformations were determined. The concentrations of humic compounds were measured by means of optical density at the wavelengths: 254, 265, 280, 320, 465 and 665 nm. In the experiment, the H2O2/Fe2+ 10: 1 ratio was tested at with a dose of H2O2 equal to 3.4 g/l (0.1 M). It was found that the pH affects the efficiency of COD removal and the increase of the biodegradability of the landfill leachate retentate, as well as the removal of humic substances and its transformation. It was found that at pH 3, the highest removal of COD occurs, with simultaneous increase in biodegradability, and decrease of absorbance caused by humic compounds.
Źródło:
Journal of Ecological Engineering; 2019, 20, 2; 161-168
2299-8993
Pojawia się w:
Journal of Ecological Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Treatment of Laboratory Wastewater by Using Fenton Reagent and Combination of Coagulation-Adsorption as Pretreatment
Autorzy:
Arita, Susila
Agustina, Tuty Emilia
Ilmi, Nurul
Pranajaya, Violanda Dwi Wulandari
Gayatri, Rianyza
Powiązania:
https://bibliotekanauki.pl/articles/2173343.pdf
Data publikacji:
2022
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
laboratory wastewater
fenton reagent
coagulation
adsorption
heavy metal
Opis:
Laboratory wastewater contains organic and inorganic compounds that are harmful to the environment when disposed of without prior treatment. Besides the high COD and BOD values, the laboratory wastewater also contains metals such as iron (Fe), zinc (Zn), copper (Cu), chromium (Cr), and lead (Pb) which is categorized as dangerous waste material and can pollute the groundwater. Although the quantity of wastewater produced by the laboratory is relatively small, it has a real impact on the environment around the laboratory. However, the wastewater has to be treated properly before being discharged into the environment. The aim of the research was to study the laboratory wastewater treatment by using Fenton’s reagent with coagulation and adsorption pretreatment. In the pretreatment with coagulation, three types of coagulants are used, namely PAC (Poly Aluminum Chloride), ACH (Aluminum Chlorohydrate) and Aluminum Sulfate (AS) with their respective concentrations of 10–80 ppm. The highest percentage of average pollutant removal of 58.21% was found when 80 ppm of AS was applied. The pretreatment was continued by adsorption with activated carbon and zeolite adsorbents within 60–120 minutes of mixing time. It was detected that the most optimum adsorbent was activated carbon with average pollutant removal of 50.22% within 1 hour of mixing time. Processing was extended by utilized Fenton’s reagent using a variation of the molar ratio between 1:100 and 1:400. It was obtained that the best molar ratio to degrade the laboratory wastewater is 1:300 with an average removal of pollutant of 43.45%. As a result of laboratory wastewater treatment using combine Fenton’s reagent and coagulation-adsorption pretreatment, an average pollutant removal of 90.81% was obtained. The final content of COD, BOD, TSS, as well as Cu and Pb metal has met the environmental quality standard.
Źródło:
Journal of Ecological Engineering; 2022, 23, 8; 211--221
2299-8993
Pojawia się w:
Journal of Ecological Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Zastosowanie procesu głębokiego utleniania z wykorzystaniem odczynnika Fentona do usuwania formaldehydu ze ścieków przemysłowych
Using the deep oxidation process with Fenton’s reagent to remove formaldehyde from industrial wastewater
Autorzy:
Łodyga, A.
Minda-Data, D.
Kozioł, M.
Tyński, P.
Powiązania:
https://bibliotekanauki.pl/articles/1216299.pdf
Data publikacji:
2013
Wydawca:
Stowarzyszenie Inżynierów i Techników Przemysłu Chemicznego. Zakład Wydawniczy CHEMPRESS-SITPChem
Tematy:
utlenianie
odczynnik Fentona
formaldehyd
oxidation
Fenton's reagent
formaldehyde
Opis:
Reakcja utleniania z zastosowaniem odczynnika Fentona jest jedną z najbardziej efektywnych i powszechnych metod usuwania zanieczyszczeń organicznych ze ścieków przemysłowych. Odczynnik Fentona to mieszanina jonów Fe2+ i H2O2, która jest źródłem rodników hydroksylowych (OH) o wysokim potencjale utleniającym. Przedstawiono badania nad wydajnością procesu Fentona w zależności od pH roztworu, temperatury i czasu utleniania,a także od stosunku H2O2/Fe2+ dodawanego odczynnika Fentona.
Oxidation reaction with use of Fenton’s reagent is one of the most efficient and common methods of removing organic compounds from industrial wastewater. Fenton’s reagent is a mixture of Fe2+ and H2O2 ions and a source of hydroxyl radicals (OH) with a high oxidizing potential. The paper presents examinations of Fenton process efficiency depending on solution pH, temperature and oxidation duration as well as on H2O2/Fe2+ ratio of the added Fenton’s reagent.
Źródło:
Chemik; 2013, 67, 7; 648-653
0009-2886
Pojawia się w:
Chemik
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Alternative Treatment Strategy for Different Streams of Tannery Wastewater
Autorzy:
Przywara, L.
Powiązania:
https://bibliotekanauki.pl/articles/124452.pdf
Data publikacji:
2017
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
tannery wastewater
Fenton's reagent
catalytic oxidation
COD
sulphide
Opis:
This article discusses the results of laboratory tests aimed to determine the effectiveness of tannery wastewater treatment in the process of enhanced oxidation using Fenton reagent. The general sewage from the tannery located in Mazowieckie Province was used for the research. The process was carried out using two doses of iron of 0.45 g Fe2+/dm3. and 0.56 g Fe2+/dm3, and H2O2 from 2.21 g/dm3 to 4.08 g/dm3. All the tests were performed for a constant optimum pH of 3.0. Wastewater was characterized by basic physico-chemical indicators (pH, conductivity, COD, chromium, ammonium nitrogen). The efficiency of the process was determined mainly on the basis of changes in the organic pollutants identified as COD. The efficacy of the Fenton process for different doses of Fe2+ and Fe2+ / H2O2 ratio of 1: 5, 1: 6 and 1: 7 was from 69 to 80% COD reduction in relation to raw sewage. Another aspect of the study was determining the possibility of removing sulphides from the wastewater by catalytic oxygenation with oxygen from air in the presence of manganese. In this case, the wastewater produced during leather manufacture in tanneries located in the southern part of Poland was examined. The subject of the study described in the paper was to determine the optimum manganese dose and oxidation time to simultaneously remove the sulphides and organic pollutants expressed as COD. The change in pollutant content in the wastewater over time indicates that the reduction of parameters takes place within one hour after the addition of manganese. Using the process of catalytic oxidation with 0.1 g/dm3 to 0.6 g/dm3 manganese and a reaction time of 1, 3, 24 h, the sulphides were removed in the range of 50 to 99% and organic compounds in 12 to 65%.
Źródło:
Journal of Ecological Engineering; 2017, 18, 4; 160-168
2299-8993
Pojawia się w:
Journal of Ecological Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Zastosowanie reakcji Fentona do rozkładu utleniającego eteru etylowo-t-butylowego (ETBE) w wodnych ekstraktach benzyn
Application of the Fentons reaction for oxidative destruction of ETBE contained in water extracts of petrol
Autorzy:
Kędzierska, E.
Konopka, M.
Kardasz, K.
Piotrowska, K.
Powiązania:
https://bibliotekanauki.pl/articles/256398.pdf
Data publikacji:
2006
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Technologii Eksploatacji - Państwowy Instytut Badawczy
Tematy:
Fenton's reaction
ethyl-t-butyl ether
ETBE
petrol
Fenton's reagent
Opis:
W pracy podjęto próbę usuwania eteru etylowo-t-butylowego (ETBE) z wodnych ekstraktów benzyn poprzez utlenianie nadtlenkiem wodoru w reakcji Fentona. Zdolność ETBE do rozkładu pod wpływem nadtlenku wodoru w temperaturze otoczenia stanowi potencjalną możliwość usuwania tego eteru z wody zanieczyszczonej benzyną, która zawiera ETBE jako komponent.
Ethyl-t-butyl ether (ETBE) is commonly used as a fuel component, which sometimes results in its introduction into the environment, especially to ground water. The aim of this research study is to investigate the activity of Fenton's reagent with the water extracts of the fuels containing ETBE. The ETBE removal was successfully accomplished at ambient temperature in the presence of more than 0,3 g of FeSO4 catalyst per 100 cm3 of the extract.
Źródło:
Problemy Eksploatacji; 2006, 3; 223-231
1232-9312
Pojawia się w:
Problemy Eksploatacji
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wpływ czasu regeneracji na zdolności sorpcyjne węgla aktywnego WD-extra
Effect of regeneration time on adsorption capacity of activated carbon WD-extra
Autorzy:
Bezak-Mazur, E.
Adamczyk, D.
Powiązania:
https://bibliotekanauki.pl/articles/125697.pdf
Data publikacji:
2013
Wydawca:
Towarzystwo Chemii i Inżynierii Ekologicznej
Tematy:
węgiel aktywny
barwniki
regeneracja
reagent Fentona
activated carbon
dyes
regeneration
Fenton's reagent
Opis:
Zużyte lub zestarzałe węgle aktywne zaliczane są do odpadów niebezpiecznych i należy poddawać je procesowi utylizacji lub odzysku. Obecnie poszukuje się prostych, skutecznych i ekonomicznych metod regeneracji zużytych sorbentów węglowych. W pracy zaprezentowano badania regeneracji zużytego w procesie adsorpcji barwników węgla aktywnego WD-extra. Zaproponowano regenerację przy użyciu reagenta Fentona, który jest doskonałym utleniaczem. W celu wyznaczenia optymalnych warunków regeneracji została ona przeprowadzona w różnym czasie, tj. 30, 60, 120, 180, 300 i 480 min. Dla zregenerowanego tym odczynnikiem węgla aktywnego zbadano jego zdolności sorpcyjne w odniesieniu do wybranych barwników. Do badań wybrano dwa barwniki kwasowe, tj. zieleń naftolową B i błękit metylowy. Stężenie obu barwników wynosiło 400 mg/dm3. Cykl adsorpcja - regeneracja został powtórzony 6-krotnie. Badaniom zdolności sorpcyjnych węgla aktywnego wyrażonych adsorpcją właściwą towarzyszyła kontrola ubytku masy adsorbentu. Wyniki przeprowadzonych badań pozwoliły na stwierdzenie, iż wraz ze wzrostem czasu regeneracji zwiększa się ubytek masy węgla aktywnego. Po VI regeneracjach w czasie 30 min odnotowano ubytek masy ok. 5% i ok. 8%, odpowiednio dla zieleni naftolowej B i błękitu metylowego. Natomiast 6-krotna regeneracja w czasie 480 min spowodowała ubytek masy o ok. 13% (zieleń naftolowa B) i ok. 21% (błękit metylowy). Izotermy sorpcji otrzymane dla węgli regenerowanych w zróżnicowanym czasie są bardzo podobne, a odnotowany ubytek masy wraz z wydłużeniem czasu regeneracji pozwolił na stwierdzenie, że optymalnym czasem regeneracji może być 30 min.
Worn or grown old activated carbons are classified as hazardous waste and they should be disposal or recovery. Currently simple, efficient and economical methods of regeneration of spent carbon sorbents is looked for. The paper presents a study in the regeneration of spent activated carbon WD-extra adsorption of dyes. Proposed regeneration using Fenton's reagent, which is an excellent oxidant. To determine the optimal conditions for regeneration has been carried out at different times 30, 60, 120, 180, 300 and 480 min. For this reagent’s regeneration, activated carbon adsorption capacity was examined in its relation to the selected dyes. The study selected two acid dyes such as naphthol green B and methylene blue. The concentration of both dyes was 400 mg/dm3. Cycle of adsorption - regeneration was repeated 6-times. The study of the sorption capacity of activated carbon adsorption, expressed proper control of the weight loss was accompanied by the adsorbent. Results of this study has established that with increasing regeneration time increases the mass loss of activated carbon. After VI regenerations for 30 min was recorded weight loss of about 5 and 8%, respectively, for naphthol green B and methylene blue. While 6-times during regeneration of 480 min resulted in weight loss by about 13% (naphthol green B), and approximately 21% (methylene blue). Sorption isotherms obtained for carbon regenerated in different time are very similar, and the observed weight loss with prolonged regeneration time has established that the optimal recovery time can be 30 min.
Źródło:
Proceedings of ECOpole; 2013, 7, 2; 539-545
1898-617X
2084-4557
Pojawia się w:
Proceedings of ECOpole
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Efektywność oczyszczania koncentratu odcieków po odwróconej osmozie odczynnikiem Fentona
The efficiency of reverse osmosis landfill leachate concentrate treatment by aop
Autorzy:
Koc-Jurczyk, J.
Powiązania:
https://bibliotekanauki.pl/articles/400499.pdf
Data publikacji:
2012
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
odcieki składowiskowe
odwrócona osmoza
odczynnik Fentona
leachate
RO
Fenton's reagent
Opis:
W pracy badano wpływ różnych stosunków molowych reagentów chemicznych odczynnika Fentona na efektywność oczyszczania koncentratu odcieków składowiskowych po odwróconej osmozie. Odcieki pobrano ze składowiska odpadów komunalnych w Kozodrzy koło Rzeszowa. W badaniach zastosowano stosunki H2O2/Fe(II) wynoszące 13,3; 6,6; 5 i 3,3. Proces odwróconej osmozy nie wpłynął znacząco na poprawę jakości odcieków. Dalsze zastosowanie odczynnika Fentona nie spowodowało poprawy biodegradowalności odcieków oczyszczonych. Najmniejszy wpływ reagentów na koncentrat stwierdzono przy proporcji H2O2/Fe(II) wynoszącej 6,6. Efektywność usuwania ChZT wyniosła 12,6%, a BZT5 – 61,6%. Najwyższą efektywność usuwania ChZT zaobserwowano w przypadku stosunku H2O2/Fe(II) – 13,3 (84,8%). W przypadku BZT5 najwyższą sprawność oczyszczania stwierdzono przy stosunku molowym reagentów wynoszącym 13,3 (89,7%) oraz 3,3 (89,5%).
In this paper the influence of chemical reagents ratios in Fenton’s reaction on the efficiency of reverse osmosis landfill leachate concentrate treatment was investigated. The leachate were sampled from the community landfill in Kozodrza (Poland; Podkarpacie Province). In the study 13,3; 6,6; 5 and 3,3 ratios of H2O2/Fe(II) was verified. The process of reverse osmosis did not influence significantly the quality of leachate, and further application of the Fenton's reagents did not increase the biodegradability of effluent. The slightest effect of the reactants on concentrate was H2O2/Fe (II) was observed with the 6,6 ratio. The efficiency of the COD removal was 12,6%, and BOD5 – 61,6%. The highest COD removal efficiency was observed for the proportion H2O2/Fe(II)- 13.3 (84.8%) while the highest efficiency of BOD5 removal was found for the proportion of 13.3 (89.7%) and 3.3 (89.5%).
Źródło:
Inżynieria Ekologiczna; 2012, 31; 72-79
2081-139X
2392-0629
Pojawia się w:
Inżynieria Ekologiczna
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Optymalizacja warunków procesu pogłębionego utleniania odcieków składowiskowych odczynnikiem Fentona
Optimization of advanced oxidation process of the municipal landfill leachate by Fenton’s reagent
Autorzy:
Koc-Jurczyk, J.
Jurczyk, Ł.
Powiązania:
https://bibliotekanauki.pl/articles/357266.pdf
Data publikacji:
2015
Wydawca:
Politechnika Śląska
Tematy:
odcieki składowiskowe
odczynnik Fentona
temperatura
landfill leachate
Fenton's reagent
temperature
Opis:
W badaniach analizowano wpływ temperatury i proporcji reagentów chemicznych (Fe2+ i H2O2) na efektywność usuwania ChZT i zmiany proporcji BZT5/ChZT w odciekach składowiskowych pochodzących z 21-letniego składowiska odpadów komunalnych (Polska, województwo podkarpackie). Przetestowano cztery temperatury prowadzenia procesu: 30, 40, 50 i 60˚C. Badania prowadzono przy stałej dawce H2O2 – 1 g/dm3 i zmieniającej się proporcji Fe2+:H2O2: 1:3, 1:2 i 1:1. Stwierdzono, że najniższa efektywność oczyszczania odcieków zachodziła w temperaturze 40˚C niezależnie od zastosowanej proporcji reagentów chemicznych. Najbardziej efektywną okazała się proporcja Fe2+:H2O2 1:1 i temperatura 30˚C.
In this paper the influence of temperature and proportions of chemical reactants (Fe2+ i H2O2) on efficiency of COD removal and changes of BOD/COD ratios in leachate form 21 years old municipal landfill have been analyzed (Poland, Podkarpackie province). Four temperature variants: 30, 40, 50 i 60˚C. The process was conducted in constant H2O2 dose of 1 g/dm3, and variable proportions of Fe2+/H2O2: 1:3, 1:2 i 1:1. It was stated that in temperature of 40˚C treatment was most ineffective regardless of reactant doses. The most efficient conditions for examined wastewater was dose 1:1 at the temperature of 30˚C.
Źródło:
Archiwum Gospodarki Odpadami i Ochrony Środowiska; 2015, 17, 3; 1-8
1733-4381
Pojawia się w:
Archiwum Gospodarki Odpadami i Ochrony Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies