Tytuł:
Force ratio in masticatory muscles after total replacement of the temporomandibular joint
Autorzy:
Vilimek, M.
Horak, Z.
Baca, W.
Powiązania:
https://bibliotekanauki.pl/articles/307085.pdf
Data publikacji:
2016
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
dynamika odwrotna
optymalizacja statyczna
staw skroniowo-żuchwowy
siły mięśniowe
inverse dynamics
static optimization
temporomandibular joint
muscle forces
mastication
FE analyses
Opis:
The temporomandibular (TM) joint is one of the most active joints in the human body, and any defect in this joint has a significant impact on the quality of life. The objective of this study was to analyze changes in the force ratio after TM joint replacement on contralateral TM joint loading. Implantation of an artificial TM joint often requires removal of 3 of the 4 masticatory muscles (activators). In order to perform true loading of the TM joint, loading during mastication was investigated. Input kinematic variables and mastication force were experimentally examined. The inverse dynamics approach and static optimization technique were used for solution of the redundant mechanism. Muscle forces, and reactions in the TM joint were calculated. We modified the model for several different tasks. The m. temporalis and m. masseter were removed individually and together and the forces of mastication on the TM joint were calculated for each variation. To evaluate the results, a parametric numerical FE analysis was created to compare the magnitude of the TM joint loading during the bite process for four different muscle resections. The results show an influence relative to the extent of muscle resection on contralateral TM joint loading in a total TM joint replacement. The biggest increase in the loading magnitude on the contralateral TM joint is most evident after m. masseter and m. temporalis resection. The results from all simulations support our hypothesis that the greater the extent of muscle resection the greater the magnitude of contralateral TM joint overloading.
Źródło:
Acta of Bioengineering and Biomechanics; 2016, 18, 3; 131-136
1509-409X
2450-6303
Pojawia się w:
Acta of Bioengineering and Biomechanics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Fracture analysis of the pulley of a bucket wheel boom hoist system
Analiza pęknięć koła pasowego układu wciągarki Wysięgnika koła czerpakowego
Autorzy:
Bošnjak, S.
Arsić, M.
Savićević, S.
Milojević, G.
Arsić, D.
Powiązania:
https://bibliotekanauki.pl/articles/301935.pdf
Data publikacji:
2016
Wydawca:
Polska Akademia Nauk. Polskie Naukowo-Techniczne Towarzystwo Eksploatacyjne PAN
Tematy:
bucket wheel excavator
pulley fracture
experimental investigations
FE stress analyses
koparka kołowa
pęknięcie koła pasowego
badania doświadczalne
analiza naprężeń metodą elementów skończonych
Opis:
This paper presents the results of the pulley fracture analysis. Experimental investigations confirmed that the chemical composition and basic mechanical properties of the pulley material, except the impact energy at a temperature of –20°C, meet the requirements of the corresponding standard. The impact energy value at the temperature of –20°C is for ≈45% lower than the prescribed value which has considerable influence on the appearance of the brittle fracture, especially having in mind the fact that the bucket wheel excavators operate at low temperatures. Metallographic examinations as well as magnetic particle inspections indicated that initial cracks in the welded joints occurred during the manufacture of the pulleys. Characteristic levels of the rope load cycle are obtained by using in-house software which includes the dynamic effects of the resistance-to-excavation. The FEA results pointed out that in the representative load cases the combinations of the mean stress and the alternating stress in the pulley critical zone lie considerably below the limit line of the modified Goodman’s diagram. The conclusion, based on the presented results, is that the fracture of the pulley appeared as the result of the ‘manufacturing-in’ defects.
Artykuł przedstawia wyniki analizy pęknięć koła pasowego. Badania doświadczalne potwierdziły, że skład chemiczny oraz podstawowe właściwości mechaniczne materiału, z którego zostało wykonane koło pasowe, za wyjątkiem energii udaru w temperaturze –20°C, były zgodne z odpowiednią normą. Wartość energii udaru w temperaturze –20°C była o ≈45% niższa od wartości zalecanej, co ma znaczący wpływ na występowanie pękania kruchego, zwłaszcza gdy weźmie się pod uwagę fakt, że koparki kołowe są przeznaczone do pracy w niskich temperaturach. Badania metalograficzne oraz badania magnetyczno-proszkowe wykazały, że pęknięcie pierwotne w połączeniu spawanym pojawiło się już w fazie produkcji koła pasowego. Charakterystyczne poziomy cyklu obciążenia liny uzyskano stosując własne oprogramowanie, które uwzględnia dynamiczne oddziaływanie odporności na urabianie. Wyniki MES pokazały, że w przypadku obciążeń reprezentatywnych, wartości średniego naprężenia w funkcji naprężenia zmiennego w strefie krytycznej koła pasowego były znacznie niższe niż wartości graniczne wyznaczone na podstawie zmodyfikowanego wykresu Goodmana. Na podstawie otrzymanych wyników stwierdzono, że pęknięcie koła pasowego powstało wskutek wad produkcyjnych.
Źródło:
Eksploatacja i Niezawodność; 2016, 18, 2; 155-163
1507-2711
Pojawia się w:
Eksploatacja i Niezawodność
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-2 z 2

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies