Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "FAAS" wg kryterium: Temat


Wyświetlanie 1-8 z 8
Tytuł:
Simultaneous adsorption of heavy metals from water by novel lemon-peel based biomaterial
Autorzy:
Šabanović, Elma
Memić, Mustafa
Sulejmanović, Jasmina
Selović, Alisa
Powiązania:
https://bibliotekanauki.pl/articles/778437.pdf
Data publikacji:
2020
Wydawca:
Zachodniopomorski Uniwersytet Technologiczny w Szczecinie. Wydawnictwo Uczelniane ZUT w Szczecinie
Tematy:
lemon peel
heavy metals
biosorption
FAAS
Opis:
Simultaneous adsorption of heavy metals in complex multi metal system is insuffnciently explored. This research gives results of key process parameters optimization for simultaneous removal of Cd(II), Co(II), Cr(III), Cu(II), Mn(II), Ni(II) and Pb(II) from aqueous solution (batch system). New lemon peel-based biomaterial was prepared and characterized by infrared spectroscopy with Fourier transformation (FTIR), scanning electron microscopy (SEM), electron dispersive spectroscopy (EDS), while the quantifi cation of metals was made by atomic absorption spectrometry (AAS). Simultaneous removal of seven metals ions was favorable at pH 5 with 300 mg/50 mL solidliquid phase ratio, within 60 min at room temperature with total obtained adsorption capacity of 46.77 mg g–1. Kinetic modeling showed that pseudo-second order kinetic and Weber-Morris diffusion models best describe the adsorption mechanism of all seven heavy metals onto lemon peel.
Źródło:
Polish Journal of Chemical Technology; 2020, 22, 1; 46-53
1509-8117
1899-4741
Pojawia się w:
Polish Journal of Chemical Technology
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Evaluation of the Content of Selected Heavy Metals in Samples of Polish Honeys
Autorzy:
Sitarz-Palczak, E.
Kalembkiewicz, J.
Galas, D.
Powiązania:
https://bibliotekanauki.pl/articles/123800.pdf
Data publikacji:
2015
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
bee products
heavy metals
FAAS
Opis:
This paper presents the result of the determination of the total content of Cu, Pb and Zn by the method of atomic absorption spectrometry with atomization in an air-acetylene flame in Polish honeys samples. The research material was a honeydew, monofloral honey and buckwheat honey. For the mineralization of samples, the following solutions were applied: 1) HNO3(conc), 2) HNO3(conc) and H2O2(conc) in the volume ratio equal to 4:1 and 3:1. On the basis of the results and recommended food standards the percentage of the recommended dietary allowances (RDA) in connection with the consumption of 100 g of product were estimated. To verify the results validation of analytical method used was carried out. It was included defining the following validation parameters values: the limit of detection and quantification; linearity and measurement range; repeatability and accuracy of the results. The contamination of the analyzed honeys by Pb is higher than the acceptable level of contamination of this element. The highest contents of Cu and Zn were characterized by monofloral honeys.
Źródło:
Journal of Ecological Engineering; 2015, 16, 3; 130-138
2299-8993
Pojawia się w:
Journal of Ecological Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analysis of some heavy metals and physicochemical parameters of textile sludge sample in the Bahir Dar textile industry, Northern Amhara, Ethiopia
Autorzy:
Talema, Alemu
Abebaw, Alemayehu
Getahun, Addisu
Powiązania:
https://bibliotekanauki.pl/articles/1046523.pdf
Data publikacji:
2019
Wydawca:
Przedsiębiorstwo Wydawnictw Naukowych Darwin / Scientific Publishing House DARWIN
Tematy:
FAAS
Textile sludge
contaminated soil
heavy metals
physicochemical parameters
Opis:
The present study was conducted to characterize the solid sludge from the Bahir Dar textile industry.The concentration of heavy metals (Cr, Cd, Zn, Fe, Pb, Cu and Mn) in the samples were found to be 37.433-50.967, ND, 244.8-279.9, 2868.633-2886.667, 4.567-7.83, 242.767-282.133 and 160.9-212.8 (mg/Kg) respectively. The range of the pH, EC (%), OM (%), OC (%), MC (%), VS (%) and FS (%) in the sludge samples were found to be in the ranges of 7.317-7.771, 1.466-1.872, 12.302-12.778, 7.136-7.412, 9.211-11.576, 44.598-47.778 and 52.222-55.402 respectively. The results of the heavy metals in the textile sludge sample showed that the concentration levels of Cu metal was above the standard guide lines for maximum limit proposed for agricultural soil set by FAO /WHO and in the case of other metals (Pb, Zn, Mn, Fe, Cr), their concentration levels were found below the standard guide lines for maximum limit proposed for agriculture soil set by this organization, but the concentration levels of Cd was not detected in this present study. Finally, the study concluded that pre-treatment process for reducing the amount of some heavy metal is mandatory before the sludge can be used as a soil conditioner / fertilizer in the agricultural soil.
Źródło:
World Scientific News; 2019, 136; 33-51
2392-2192
Pojawia się w:
World Scientific News
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Diody LED - odpady niebezpieczne dla środowiska
LED diodes - environmentally hazardous waste
Autorzy:
Sokołowska, W.
Karaś, A.
Zalewska, I.
Harasimowicz-Siemko, J.
Powiązania:
https://bibliotekanauki.pl/articles/192226.pdf
Data publikacji:
2011
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Technologii Materiałów Elektronicznych
Tematy:
dioda LED
ICP-OES
FAAS
ochrona środowiska
recykling
light-emitting diodes
environmental protection
recycling
Opis:
W Laboratorium Charakteryzacji Materiałów Wysokiej Czystości ITME przeprowadzono analizę składu chemicznego kilku rodzajów diod LED obecnych na polskim rynku [2]. Omówiono zawartość metali kancerogennych oraz metali niebezpiecznych dla środowiska . Porównano je z rezultatami uzyskanymi w UCI (Uniwersytet Kalifornia) opisanymi w [1] i normami TTCL.
An analysis of the chemical composition of several types of light-emitting diodes available on the Polish market was conducted in the Department of High Purity Materials Characterization of ITME [2]. In the course of the analysis, the content of carcinogenic metals and environmentally hazardous metals was explored. The findings were compared with the results achieved at the University of California, Irvine, described in [1], and with TTCL standards.
Źródło:
Materiały Elektroniczne; 2011, T. 39, nr 2, 2; 23-26
0209-0058
Pojawia się w:
Materiały Elektroniczne
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
A modified nanoporous stir bar for simultaneous determination of Cu(II) and Cd(II) ions in natural samples prior to flame atomic absorption spectroscopy
Autorzy:
Karimi, M.
Aboufazeli, F.
Zadeh Zhad, H. R. L.
Sadeghi, O.
Najafi, E.
Powiązania:
https://bibliotekanauki.pl/articles/780050.pdf
Data publikacji:
2013
Wydawca:
Zachodniopomorski Uniwersytet Technologiczny w Szczecinie. Wydawnictwo Uczelniane ZUT w Szczecinie
Tematy:
stir bar sorptive extraction
nanoporous structure
Cd(II) and Cu(II) determination
FAAS
Opis:
In this work, the application of stir bar sorptive extraction (SBSE), as a fast and conventional method, has been investigated for the simultaneous preconcentration and determination of trace amounts of Cd(II) and Cu(II) ions in natural samples. For this purpose, the surface of stir bar was functionalized by amine functionalized nanoporous silica and characterized by IR spectroscopy, X-ray powder diffraction (XRD), Atomic force microscopy (AFM) and N2 adsorption. In this approach, after the preconcentration of Cd(II) and Cu(II) ions and removing the matrix interferences using modified stir bar, the amounts of these ions were determined in eluent by flame atomic absorption spectroscopy (FAAS). Various parameters on adsorption and elution steps including pH of sample, adsorption kinetic, eluent parameters (type, volume and concentration) and elution time, have been optimized in this study. The limits of detection (LOD) were 1.6 and 13.8 ng mL-1 (recovery of 83.5 and 88.1%) for cadmium and copper ions, respectively. The preconcentration factors were 133 and 137 and the relative standard deviations (RSD) of the method were 5.7 and 4.6% for Cd(II) and Cu(II) ions, respectively. As the key point in this study seems to be stir bar nanoporous structure, the analytical performance of this stir bar was compared to non-porous ones. The accuracy of this novel method has been confirmed using some standard references materials. Finally the potential of this method was investigated by determination of Cd(II) and Cu(II) ions in some real samples with complicated matrixes.
Źródło:
Polish Journal of Chemical Technology; 2013, 15, 2; 86-93
1509-8117
1899-4741
Pojawia się w:
Polish Journal of Chemical Technology
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Oznaczanie zawartości Y, Al, Nd oraz zanieczyszczeń w próbkach Y4Al2O9 (YAM) niedomieszkowanych i domieszkowanych neodymem
The determination of Y, Al, Nd and impurities in Y4Al2O9 (YAM) undoped and neodymium-doped samples
Autorzy:
Harasimowicz-Siemko, J.
Karaś, A.
Sokołowska, W.
Dąbrowska, D.
Powiązania:
https://bibliotekanauki.pl/articles/192228.pdf
Data publikacji:
2011
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Technologii Materiałów Elektronicznych
Tematy:
YAM
Y
Al
Nd
oznaczanie zanieczyszczeń
FAAS
ICP-OES
spektrografia
spektrofotometria UV-VIS
determination of impurities
UV-VIS spectrophotometre
spectrograph
Opis:
Celem niniejszej pracy było oznaczenie głównych pierwiastków (Y, Al, Nd) kryształów YAM niedomieszkowanych i domieszkowanych neodymem oraz zanieczyszczeń śladowych. Pierwszym etapem pracy było dobranie odpowiednich warunków pracy urządzenia do mikrofalowego roztwarzania w celu przeprowadzenia próbek do fazy ciekłej. Następnie wykonano analizę jakościową i półilościową z wykorzystaniem spektrografu emisyjnego w celu określenia poziomu zanieczyszczeń. Oznaczono za pomocą FAAS Al i Nd przy zastosowaniu 0,1% chlorku cezu (bufor jonizacyjny) i 0,2% chlorku lantanu (bufor chemiczny) oraz oznaczono itr za pomocą ICP-OES.
The purpose of this study was to determine both the major elements (Y, Al, Nd) of YAM crystals, undoped and doped with neodymium, and impurities. The first stage of the study was the selection of conditions appropriate for microwave digestion in order to transfer the samples to the liquid phase. Then, the qualitative and semiquantitative analysis of the samples using emission spectrography was performed with a view to identifying the level of impurities. The concentration of aluminium and neodymium in YAM samples was determined by FAAS, using 0.1% of cesium chloride (ionization buffer) and 0.2% of lanthanum chloride (chemical buffer). The concentration of yttrium was measured by the ICP-OES method.
Źródło:
Materiały Elektroniczne; 2011, T. 39, nr 2, 2; 26-31
0209-0058
Pojawia się w:
Materiały Elektroniczne
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Porównanie procedur przygotowania próbek herbat do analizy wielopierwiastkowej metodami ICP OES i FAAS
Autorzy:
Szymczycha-Madeja, A.
Wełna, M.
Pohl, P.
Stelmach, E.
Jędryczko, D.
Powiązania:
https://bibliotekanauki.pl/articles/273894.pdf
Data publikacji:
2015
Wydawca:
Roble
Tematy:
herbata
analiza wielopierwiastkowa
optyczna spektrometria emisyjna
spektrometria atomowa absorpcyjna płomieniowa
ICP-OES
FAAS
próbka badawcza
tea
multi-element analysis
optical emission spectrometry
flame atomic absorption spectrometry
Opis:
W pracy porównano różne procedury (klasyczne i alternatywne) przygotowania próbek herbaty czarnej i zielonej w ich analizie wielopierwiastkowej metodami ICP OES i FAAS. Analiza statystyczna wyników wraz z oceną wybranych parametrów walidacyjnych porównywanych metod analitycznych pozwoliła na wybór znacznie prostszej i szybszej procedury przygotowania próbek bez konieczności ich rozkładu mokrego.
Źródło:
LAB Laboratoria, Aparatura, Badania; 2015, 20, 4; 20-23
1427-5619
Pojawia się w:
LAB Laboratoria, Aparatura, Badania
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Badanie zawartości wybranych metali ciężkich w separatorze polimerowym akumulatora kwasowo-ołowiowego
Analysis of the selected heavy metals content in the lead-acid battery polymeric separator
Autorzy:
Kolasa, Dorota
Łukomska, Aneta
Sołtysiak, Joanna
Soszko, Michał
Ciężarek, Olga
Lach, Jakub
Wróbel, Kamil
Czerwiński, Andrzej
Powiązania:
https://bibliotekanauki.pl/articles/947358.pdf
Data publikacji:
2019
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Chemii Przemysłowej
Tematy:
separatory elektrod
polietylen
oznaczanie metali ciężkich
mineralizacja mikrofalowa
absorpcyjna spektrometria atomowa z atomizacją w płomieniu (FAAS)
analizator rtęci
skaningowa mikroskopia elektronowa/spektrometria dyspersji energii promieniowania rentgenowskiego (SEM/EDS)
spektroskopia w podczerwieni z transformacją Fouriera (FT-IR)
electrode separators
polyethylene
heavy metals determination
microwave-assisted digestion
flame atomic absorption spectrometry (FAAS)
mercury analyzer
scanning electron microscopy/energy dispersive X-ray spectrometry (SEM/EDS)
Fourier transform infrared spectroscopy (FT-IR)
Opis:
W materiale polimerowym stosowanym jako separator elektrod w akumulatorze kwasowo-ołowiowym oznaczano zawartość kadmu, ołowiu i rtęci. W kontekście obowiązujących przepisów dotyczących wprowadzanych do obrotu baterii i akumulatorów oraz przetwarzania zużytych baterii i zużytych akumulatorów porównano wyniki badania próbek separatora przed użyciem w procesach elektrochemicznych oraz próbek odpadowych. W badaniach separatora [poprzedzonych analizą jakościową tworzywa metodami: skaningowej mikroskopii elektronowej/spektrometrii dyspersji energii promieniowania rentgenowskiego (SEM/EDS) i spektroskopii w podczerwieni z transformacją Fouriera (FT-IR)] wykorzystano nowoczesny aparat do mikrofalowego roztwarzania próbek w połączeniu z techniką absorpcyjnej spektrometrii atomowej z atomizacją w płomieniu (FAAS) i analizatorem rtęci. Zastosowane procedury analityczne weryfikowano na podstawie wyników badania certyfikowanego materiału odniesienia (PE-LD) zawierającego śladowe ilości analitów.
Results of cadmium, lead and mercury determination in the polymeric material used as an electrode separator in the lead-acid battery have been presented. Samples of the separator before use in the electrochemical processes and the waste separator samples have been compared with reference to the existing laws on batteries and accumulators and waste batteries and accumulators. In the polymer separator examination [preceded by a qualitative analysis of the material using scanning electron microscopy/ energy dispersive X-ray spectrometry (SEM/EDS) and Fourier transform infrared spectroscopy (FT-IR) techniques], a modern UltraWAVE digestion system combined with flame atomic absorption spectrometry (FAAS) technique and a DMA-80 Direct Mercury Analyzer has been used. The quality of metal determination results has been evaluated using a certified PE-LD reference material containing trace amounts of analytes.
Źródło:
Polimery; 2019, 64, 6; 442-451
0032-2725
Pojawia się w:
Polimery
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-8 z 8

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies