Tytuł:
Stability study of free radicals in 10 MeV electron beam irradiated quartz as an EPR dosimetry method
Autorzy:
Ziaie, F.
Mohammadzadeh, A.
Modarresi, M.
Powiązania:
https://bibliotekanauki.pl/articles/148163.pdf
Data publikacji:
2009
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
quartz dosimeter
EPR response
dose rate
electron beam
EPR signal stability
Opis:
In this work the stability of free radicals induced by a 10 MeV electron beam in quartz samples was studied. The investigations have been done for different doses and different dose rates. For this reason, quartz samples in powder form were irradiated at different dose rates, i.e. 100, 260 and 630 kGy/min for absorbed dose range of similar to 5–80 kGy using the 10 MeV electron beam radiation. The dose values were validated using a polystyrene calorimeter system as a reference standard dosimetry system. The EPR optimum system parameters were defined and EPR responses at room temperature in air were measured and compared. The EPR signal, which is due to the free radicals induced by electron beam, was also investigated at different time intervals to check its stability. The main objective of this work was to study the feasibility of using quartz as a dosimeter. Thus, the variation of EPR signal intensities with the absorbed dose values were evaluated and plotted in a graph. The results show that the variation of dose rate, do not affect considerably the EPR response.
Źródło:
Nukleonika; 2009, 54, 4; 251-254
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Bone powder as EPR dosimetry system for electron and gamma radiation
Autorzy:
Ziaie, F.
Hajiloo, N.
Fathollahi, H.
Mehtieva, S. I.
Powiązania:
https://bibliotekanauki.pl/articles/148156.pdf
Data publikacji:
2009
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
bone powder dosimeter
EPR response
dose rate
electron beam
gamma ray
Opis:
In this work bovine bone powder samples were irradiated at three different dose rates of 100, 260 and 630 kGy/min for the absorbed dose range of 3 to 110 kGy, using 10 MeV electron beam radiation. The samples were subjected to EPR measurement at room temperature in air. The variation of EPR signal intensities were constructed and evaluated base on quantitative data related to the absorbed doses. Moreover, they were compared with the obtained results from the samples irradiated by a 60Co gamma-ray source with a dose rate of 2.65 kGy/h. The time and temperature effects on the EPR response of this dosimeter were also studied. The results indicated that the bone sample was a suitable dosimeter especially for electron beam at high doses.
Źródło:
Nukleonika; 2009, 54, 4; 267-270
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-2 z 2

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies