Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "Dosimetry" wg kryterium: Temat


Tytuł:
Żele radiochromiczne przyszłością dozymetrii radioterapeutycznej
Radiochromic gels as the future of radiotherapeutic dosimetry
Autorzy:
Bruszewska, Anna
Górska, Monika
Mizgajska, Ewa
Poświatowska, Klaudia
Powiązania:
https://bibliotekanauki.pl/articles/32881337.pdf
Data publikacji:
2020
Wydawca:
Fundacja PSC
Tematy:
dosimetry
dose distribution
radiotherapy
radiochromic gels
Opis:
In a present work an attempt was made to describe the radiochromic gels used in radiotherapeutic dosimetry to review the available solutions. Articles related to the composition and production of these gels were analyzed. Additionally, the application and properties of 3D dosimeters, such as radiochromic gels, were discussed. Cancer is one of the biggest problem of modern medicine and the reason to develop new and more accurate dosimeters. The gels discussed in this article allow to obtain promising results and confirm the validity of the continuation of research on both current and new solutions used in teleradiotherapy dosimetry.
Źródło:
Alcumena. Pismo Interdyscyplinarne; 2020, 3(3); 19-33
2719-9851
Pojawia się w:
Alcumena. Pismo Interdyscyplinarne
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Zastosowanie dozymetrii radiofotoluminescencyjnej RPLD w dozymetrii indywidualnej i klinicznej
Application of RPLD radio-photoluminescent dosimetry in individual and clinical dosimetry
Autorzy:
Dudała, Joanna
Fałowska, Olga
Powiązania:
https://bibliotekanauki.pl/articles/2146812.pdf
Data publikacji:
2019
Wydawca:
Indygo Zahir Media
Tematy:
dozymetria RPL
dozymetria kliniczna
dozymetria indywidualna
RPL dosimetry
clinical dosimetry
personal dosimetry
Opis:
W artykule przedstawiono zasadę działania dozymetrów radiofotoluminescencyjnych w postaci szkieł fosforowych – RPLGD oraz charakterystyczne cechy stanowiące o ich konkurencyjności w stosunku do innych metod pasywnych stosowanych w dozymetrii. Podsumowano krótko rozwój metody RPLG na przestrzeni lat oraz wskazano przykłady wykorzystania klinicznego.
The article presents the principle of operation of radiofotoluminescence dosimeters in the form of phosphor glass – RPLGD and characteristic features that determine their competitiveness in relation to other passive methods used in dosimetry. The development of the RPLG method has been summarized and examples of clinical use have been showed.
Źródło:
Inżynier i Fizyk Medyczny; 2019, 8, 6; 435--438
2300-1410
Pojawia się w:
Inżynier i Fizyk Medyczny
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wielkoskalowy system do pomiarów dozymetrycznych w przemyśle i medycynie
Large-scale system for dosimetric measurements in industry and medicine
Autorzy:
Urban, P.
Skubacz, K.
Powiązania:
https://bibliotekanauki.pl/articles/370747.pdf
Data publikacji:
2013
Wydawca:
Wyższa Szkoła Zarządzania Ochroną Pracy w Katowicach
Tematy:
promieniowanie jonizujące
dozymetria
termoluminescencja
pola mieszane
ionizing radiation
dosimetry
thermoluminescence
mixed fields
Opis:
W przemyśle, medycynie i nauce stosuje się wiele urządzeń wykorzystujących promieniowanie jonizujące, co rodzi konieczność monitorowania wynikających stąd zagrożeń. Jedną z najpowszechniej stosowanych obecnie metod detekcji promieniowania jest dozymetria termoluminescencyjna. W pracy opisano system pomiarowy firmy Panasonic oparty na tej technice i przeznaczony do oceny dawek w mieszanych polach promieniowania jonizującego o różnej energii. Jednocześnie z pomocą dawkomierzy UD-802, które są najbardziej popularnymi dawkomierzami stosowanymi w tym systemie, wykonano szereg pomiarów w placówkach medycznych stosujących instalacje do wytwarzania promieniowania jonizującego. Uzyskane wyniki porównano z rezultatami osiągniętymi równolegle przez dawkomierze Gamma-31, które są od dawna stosowane w Głównym Instytucie Górnictwa do oceny zagrożenia w podziemnych zakładach górniczych, gdzie mogą występować promieniotwórcze osady, emitujące promieniowanie gamma. Dla celów obligatoryjnego systemu kontroli w tych zakładach i środowiska wokół nich mogą być również stosowane dawkomierze UD- 802, chociaż ich konstrukcja jest bardziej wrażliwa na niekorzystne warunki środowiskowe (zapylenie, wilgotność i uszkodzenia mechaniczne).
Plenty of devices using ionizing radiation, found application in industry, medicine and science. This application may cause the necessity for monitoring related hazards. One of widely applicable methods for radiation detection which is currently in use is thermo luminescence dosimetry. This publication describes the measuring system based on the same technique made by Panasonic. The system is intended for dose assessment in mixed radiation field with various energies. Simultaneously, by means of the Panasonic dosimeters, which are the most popular in this kind of systems, several measurements in medical institutions using the installations for ionizing radiation production, were made. All results were compared with indication of the dosimeters Gamma-31(exposed in the same time) which have for many years been used in Central Mining Institute. Gamma-31 are intended for assessment of radiological hazard in underground coal mines, caused by radioactive sediments emitting gamma radiation. For the purposes of mandatory control system in the mines and the environment around them, UD-802 dosimeters can also be used, although their construction is more sensitive to adverse environmental conditions (dust, moisture and mechanical damage).
Źródło:
Zeszyty Naukowe Wyższej Szkoły Zarządzania Ochroną Pracy w Katowicach; 2013, 1(9); 68-82
1895-3794
2300-0376
Pojawia się w:
Zeszyty Naukowe Wyższej Szkoły Zarządzania Ochroną Pracy w Katowicach
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The radon dosimeter combining charcoal canisters and TLD detectors type MCP-N (LiF: Mg, Cu, P)
Dawkomierz radonowy z węglem aktywnym wyposażony w detektory termoluminescencyjne typu MCP-N (LiF: Mg, Cu, P)
Autorzy:
Bogacz, J.
Budzanowski, M.
Haber, R.
Powiązania:
https://bibliotekanauki.pl/articles/340158.pdf
Data publikacji:
2004
Wydawca:
Główny Instytut Górnictwa
Tematy:
dozymetria radonowa
detektor termoluminescencyjny
dawkomierz radonowy
radon dosimetry
thermoluminescent detector
radon dosimeter
Źródło:
Prace Naukowe GIG. Górnictwo i Środowisko / Główny Instytut Górnictwa; 2004, 1; 49-50
1643-7608
Pojawia się w:
Prace Naukowe GIG. Górnictwo i Środowisko / Główny Instytut Górnictwa
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The Chronic Dose Assessment of Three Critical Organs for Liver Scintigraphy with Using Cr-51
Autorzy:
Maranci, Ö.
Tugrul, A.
Powiązania:
https://bibliotekanauki.pl/articles/1031760.pdf
Data publikacji:
2017-09
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Tematy:
Cr-51
dosimetry
phantom
scintigraphy
TRIGA
Opis:
In this study, a dosimetric study was observed by using Cr-51 gamma radioisotope on liver scintigraphy. In this context, the source organ is determined as liver and it is aimed the evaluation of measuring doses from source organ to selected three critical organs (thyroid, gonad, and brain). An antropomorphic torso phantom has been preferred in the experiments. The measurements of critical organs doses were examined for chronic effects. Moreover, the chronic effect of Cr-51 radioisotope on critical organs was determined as cumulative dose. Thermoluminescent dosimeters were used for chronic dose assessment. In the experiments, lithium fluoride (LiF) (TLD-100) detectors were used and they were provided from Turkish Atomic Energy Authority - Cekmece Nuclear Research and Training Center and calibrated in there. Within this study, the evaluation of the cumulative doses by using Cr-51 for three critical organs was observed with an original setup by using anthropomorphic torso phantom experimentally.
Źródło:
Acta Physica Polonica A; 2017, 132, 3; 476-478
0587-4246
1898-794X
Pojawia się w:
Acta Physica Polonica A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Testy dopuszczające do użytkowania klinicznego aparatu RTG, stosowanego w terapii powierzchniowej
Commissioning for a superficial x-ray therapy unit
Autorzy:
Oborska-Kumaszyńska, Dominika
Choi, Oi Ching
Fazlic, Semir
Jaganathan, Arun
Weatherburn, Henry
Powiązania:
https://bibliotekanauki.pl/articles/2146806.pdf
Data publikacji:
2019
Wydawca:
Indygo Zahir Media
Tematy:
radioterapia powierzchniowa
radioterapia ortowoltowa
HVL
kalibracja krosowa
dozymetria absolutna
dozymetria relatywna
superficial radiotherapy
ortovoltage radiotherapy
cross-calibration
absolute dosimetry
relative dosimeters
Opis:
W radioterapii nadal stosuje się wiązki rentgenowskie z zakresu ~40-300 kV. Ze względu na powrót zainteresowania tą modalnością terapeutyczną przez organizacje profesjonalistów (IAEA, AAPM, IPEM) zostały zweryfikowane procedury dozymetryczne. Ostatnie zasady dozymetrii dla promieniowania kV opublikowano w TRS 398 (IAEA) (2006 r.) z otrzymaniem podziału na dwa zakresy (niski – do 100 kV i średni – od 80 kV). W artykule opisano realizację testów wykonanych na rzecz wprowadzenia aparatu RTG stosowanego do terapii powierzchniowej i prowadzonych zgodnie z aktualnymi raportami AAPM, IPEM i IAEA.
Kilovoltage X-ray beams (40-300 kV) continue to be used In radiotherapy,. Due to the return of interest in this radiation therapeutic modality, dosimetric procedures have been reviewed and verified by professional organizations (IAEA, AAPM, IPEM). The last dosimetry rules for kV radiation were published in TRS 398 (IAEA) (2006) for low energies – up to 100 kV and medium energies – above 80 kV. The article describes the implementation of tests performed for the introduction of RT X-ray unit, used for superficial therapy and conducted in accordance with current reports of AAPM, IPEM and IAEA.
Źródło:
Inżynier i Fizyk Medyczny; 2019, 8, 6; 423--431
2300-1410
Pojawia się w:
Inżynier i Fizyk Medyczny
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Test mikrojądrowy w retrospektywnej dozymetrii biologicznej
Micronucleus assay in rapid retrospective biological dosimetry
Autorzy:
Rawojć, K.
Miszczyk, J.
Powiązania:
https://bibliotekanauki.pl/articles/134746.pdf
Data publikacji:
2016
Wydawca:
ADVSEO
Tematy:
micronuclei
micronucleus assay
retrospective biological dosimetry
ionizing radiation
cell death
Opis:
Rapid retrospective biological dosimetry allows absorbed dose evaluation post exposure to ionizing radiation. One of the main tools of biodosimetry is based on the analysis of the effects resulting from the impact of ionizing radiation on the cell. Various cytogenetic tests give possibility of the accurate dose estimation. To investigate cell response to radiation one performs the analysis of biomarkers approved by International Atomic Energy Agency e.g. the analysis of dicentric chromosomes or micronuclei frequency. Micronucleus test is relatively a faster and therefore more effective method to study changes in the genetic material, induced by various genotoxic agents. This study confirms that micronulei frequency and nuclear division index analysis allows for appropriate absorbed dose estimation when it comes to ionizing radiation. In order to further optimize and facilitate the micronucleus assay and other cytogenetic tests in rapid retrospective biological dosimetry, the research are still ongoing.
Źródło:
Technical Issues; 2016, 4; 78-82
2392-3954
Pojawia się w:
Technical Issues
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Taurine-EVA copolymer-paraffin rods dosimeters for EPR high-dose radiation dosimetr
Autorzy:
Maghraby, A. M.
Mansour, A.
Abdel-Fattah, A. A.
Powiązania:
https://bibliotekanauki.pl/articles/147366.pdf
Data publikacji:
2014
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
EPR
ESR
radiation dosimetry
taurine
alanine
Opis:
Taurine/EPR rods (3 × 10 mm) have been prepared by a simple technique in the laboratory where taurine powder was mixed with a molten mixture of paraffin wax and an ethylene vinyl acetate (EVA) copolymer. The binding mixture EVA/Paraffin does not present interference or noise in the EPR signal before or after irradiation. The rods show good mechanical properties for safe and multi-use handling. An EPR investigation of radiation induced radicals in taurine rods revealed that there are two types of radicals produced after exposure to gamma radiation (60Co). EPR spectra were recorded and analyzed – also the microwave power saturation and modulation amplitude were studied and optimized. Response of taurine to different radiation doses (1.5–100 kGy) was studied and found to follow a linear relationship up to 100 kGy. Radiation induced radicals in taurine persists and showed a noticeable stability over 94 days following irradiation. Uncertainities associated with the evaluation of radiation doses using taurine dosimeters were discussed and tabulated. It was found that taurine possesses good dosimetric properties using EPR spectroscopy in high doses in addition to its simple spectrum.
Źródło:
Nukleonika; 2014, 59, 1; 9-13
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Strategiczny projekt badawczy Narodowego Centrum Badań i Rozwoju pt. " Technologie wspomagające rozwój bezpiecznej energetyki jądrowej" Zadanie nr 6. Rozwój metod zapewnienia bezpieczeństwa jądrowego i ochrony radiologicznej dla bieżących i przyszłych potrzeb energetyki jądrowej. Cel 2: Rozwój metod dozymetrii biologicznej oraz biofizycznych markerów i indykatorów wpływu promieniowania na organizmy żywe. (Etapy 6, 7, 8, 9, i 10)
Strategic research project of The National Centre for Research and Development ‘Technologies supporting the development of safe nuclear power’ Research task No. 6 „Development of nuclear safety and radiological protection methods for the nuclear power engineering’s current and future needs” Objective 2. Development of the biodosimetry and biophysics markers of ionizing radiation in leaving beings
Autorzy:
Brzóska, K.
Kowalska, M.
Kruszewski, M.
Lankoff, A.
Sommer, S.
Powiązania:
https://bibliotekanauki.pl/articles/214133.pdf
Data publikacji:
2015
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
dozymetria biologiczna
test chromosomów dicentrycznych
ekspresja genów
promieniowanie neutronowe
szybka identyfikacja osób napromienionych
biological dosimetry
dicentric assay
gene expression
neutron radiation
radiation triage
Opis:
Dozymetria biologiczna pozwala odczytać dawkę pochłoniętą promieniowania jonizującego w organizmie i jest niezbędnym elementem systemu ochrony radiologicznej. Aby zapewnić większą wiarygodność uzyskanych wyników metoda analizy dicentryków zostanie akredytowana w 2 laboratoriach, a w jednym istniejąca akredytacja zostanie rozszerzona o biodozymetrię mieszanego promieniowania gamma i neutronowego. Jedną ze strategii dostosowania dozymetrii biologicznej do scenariusza masowego zdarzenia jest łączenie laboratoriów we współdziałającą sieć. Założenia takiej sieci zostały opracowane i opisane. W trakcie projektu wypróbowano nowe, obiecujące metody: analizę ekspresji genów (m.in. FDXR, GADD45A) na poziomie mRNA z wykorzystaniem techniki PCR oraz metody oparte na PCC (przedwczesnej kondensacji chromosomów), w szczególności RICA (The Rapid Interphase Chromosome Assay). Obie metody okazały się skutecznymi metodami dozymetrii biologicznej.
Biological dosimetry allows to read the absorbed dose of ionizing radiation in the body and is an essential element of the system of radiological protection. To ensure greater reliability of the results obtained by dicentric assay method will be accredited in 2 laboratories, and one existing accreditation will be extended to biodosimetry of mixed gamma and neutron radiation. One of the strategies to adapt biological dosimetry to the mass events scenario is to combine laboratories in cooperating network. Assumptions of such a network have been developed and described. The new methods of biological dosimetry have been investigated: analysis of gene expression (including FDXR, GADD45A) at the mRNA level using PCR method and methods based on the PCC (premature chromosome condensation), in particular RICA (The Interphase Chromosome Rapid Assay). Both methods have proven to be effective methods of biological dosimetry.
Źródło:
Postępy Techniki Jądrowej; 2015, 2; 42-46
0551-6846
Pojawia się w:
Postępy Techniki Jądrowej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Status of radon dosimetry in Zambian underground mines
Stan dozymetrii radonowej w kopalniach podziemnych w Zambii
Autorzy:
Hayumbul, P.
Mulenga, S.
Nomai, M.
Mulenga, P.
Katebe, R.
Shaba, P.
Chunga, T.
Inambao, D.
Mangala, F.
Tembo, P.
Malma, Y.
Powiązania:
https://bibliotekanauki.pl/articles/340154.pdf
Data publikacji:
2004
Wydawca:
Główny Instytut Górnictwa
Tematy:
dozymetria radonowa
Zambia
górnictwo miedzi
górnictwo kobaltu
radon dosimetry
copper mining
cobalt mining
Źródło:
Prace Naukowe GIG. Górnictwo i Środowisko / Główny Instytut Górnictwa; 2004, 1; 47-49
1643-7608
Pojawia się w:
Prace Naukowe GIG. Górnictwo i Środowisko / Główny Instytut Górnictwa
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Rozpoznanie częściowego napromienienia ciała przy pomocy testu mikrojądrowego
Recognition of partial body irradiation using a micronucleus test
Autorzy:
Sommer, Sylwester
Buraczewska, Iwona
Kruszewski, Marcin
Powiązania:
https://bibliotekanauki.pl/articles/214024.pdf
Data publikacji:
2019
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
dozymetria biologiczna
częściowe napromienienie ciała
analiza chromosomów dicentrycznych
test mikrojądrowy
biological dosimetry
partial body irradiation
dicentric analysis
micronucleus test
Opis:
Dozymetria biologiczna oprócz oszacowania wysokości dawki powinna mieć możliwość rozpoznawania czy napromienione zostało całe ciało, czy tylko jego część. Bardzo dobrze sprawdza się tutaj test chromosomów dicentrycznych, jednak prowadzone są prace również z innymi testami dozymetrycznymi. Wyniki badań wskazują, że test mikrojądrowy nie pozwala jednoznacznie na rozpoznawanie częściowego napromienienia ciała.
Biological dosimetry in addition to the estimation of the absorbed dose should be able to recognize whole or partial body irradiation. The dicentric chromosome test works very well here, however, other dosimetry tests are being examined to recognize partial body irradiation. The research results indicate that the micronucleus test does not explicitly allow the recognition of such a situation.
Źródło:
Postępy Techniki Jądrowej; 2019, 2; 30-32
0551-6846
Pojawia się w:
Postępy Techniki Jądrowej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Review of X-ray detection systems
Autorzy:
Urbański, Paweł
Grzebyk, Tomasz
Powiązania:
https://bibliotekanauki.pl/articles/27315700.pdf
Data publikacji:
2023
Wydawca:
Polska Akademia Nauk. Stowarzyszenie Elektryków Polskich
Tematy:
X-ray detection
X-ray radiation
dosimetry
luminescence
Opis:
The article presents an overview and a classification of X-ray detection methods. The main motivation for its preparation was the need to select a suitable and useful method for detecting signals from a currently developed miniature micro-electro-mechanical system (MEMS) X-ray source. The described methods were divided into passive and active ones, among which can be distinguished: chemical, luminescent, thermo-luminescent, gas ionization, semiconductor, and calorimetric methods. The advantages and drawbacks of each method were underlined, as well as their usefulness for the characterisation of the miniature MEMS X-ray source.
Źródło:
Opto-Electronics Review; 2023, 31, 3; art. no. e146554
1230-3402
Pojawia się w:
Opto-Electronics Review
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Radiation doses to technologists working with 18F-FDG in a PET center with high patient capacity
Autorzy:
Demir, M.
Demir, B.
Yaşar, D.
Sayman, H. B.
Halac, M.
Ahmed, A. S.
Özcan, K.
Uslu, I.
Powiązania:
https://bibliotekanauki.pl/articles/148501.pdf
Data publikacji:
2010
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
whole-body dose
finger doses
personnel dosimetry
18F-FDG
PET-CT
Opis:
The increasing numbers of PET studies for routine diagnosis creates a real hazard to radiation workers. The aim of this study is to estimate the annual whole-body and finger radiation dose to technologists working with 18F-FDG in a PET center with high patient potential. In our PET center, the number of PET imaging has increased almost to 5000 studies per year. Our standard dose for tumor imaging is 518 MBq of 18F-FDG. Five technologists performing all steps of 18F-FDG imaging (5 patients per technologist in a day) were officially involved round the week for handling and injecting 18F-FDG to patients. Whole-body and finger dose measurements with TLDs were performed for two different time periods: i) before shielding precautions during the first 6 months (without a shielding for sterile syringe and without a lead container for shielded syringe) and ii) after shielding precautions during the next 6 months (with a shielding for sterile syringe and with a lead container for shielded syringe). The average annual whole-body radiation dose for one technologist before shielding precautions was 7.82 mSv and after shielding precautions was 5.76 mSv. On the other hand, while the average annual finger radiation doses for one technologist before shielding precautions were 210.36 and 293.72 mSv for the left and right hand, after shielding precautions were they 158.16 and 217.58 mSv for the left and right hand, respectively. According to our results, if one technologist performs the whole-body PET imaging of 5 patients per day, the annual radiation dose to this technologist will not exceed the recommended limits by ICRP.
Źródło:
Nukleonika; 2010, 55, 1; 107-112
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Quasi-Static Electromagnetic Dosimetry: From Basic Principles to Examples of Applications
Autorzy:
Andreuccetti, D.
Zoppetti, N.
Powiązania:
https://bibliotekanauki.pl/articles/91016.pdf
Data publikacji:
2006
Wydawca:
Centralny Instytut Ochrony Pracy
Tematy:
numerical electromagnetic dosimetry
quasi-static conditions
voxel phantoms
finite differences
SPFD
current vector potential method
impedance network method
pole elektromagnetyczne
dozymetria
Opis:
An overview of quasi-static electromagnetic dosimetry is presented. After an introductive description of quantities and standards and a quick look at experimental and analytical approaches, attention is focused on numerical dosimetry. The process that leads to the calculation of results is analyzed in its basic steps, including the representation of the human body by means of a realistic voxel phantom. The most popular numerical methods are then described. An analysis of different methods in the same framework emphasizes common features and differences. This can help in choosing a more suitable method to solve a particular problem. An example of an application is finally reported.
Źródło:
International Journal of Occupational Safety and Ergonomics; 2006, 12, 2; 201-215
1080-3548
Pojawia się w:
International Journal of Occupational Safety and Ergonomics
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies