Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "DC-AC power conversion" wg kryterium: Temat


Wyświetlanie 1-4 z 4
Tytuł:
The use of the SSC as reactive power compensator
Autorzy:
Delfino, F.
Procopio, R.
Powiązania:
https://bibliotekanauki.pl/articles/262564.pdf
Data publikacji:
2007
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie
Tematy:
power quality
custom power
DC-AC power conversion
reactive power
Static Series Kompensator (SSC)
Opis:
The paper deals with the possibility of employing the Custom Power Static Series Compensator (SSC), whose primary aim is to compensate voltage sags, also as a Reactive Power Compensator. The idea arises from the observation that such device does not work for the majority of time and can therefore be usefully employed for other purposes, such as power factor corrections. To this aim, an "ad hoc" control algorithm is developed and thoroughly discussed in the paper. The effectiveness of such control scheme is then tested by applying the SSC to a load represented by an induction motor in order to improve its power factor. The whole system is modelled with the aid of the electromagnetic code PSCAD -EM TDC, which allows to describe with high detail all its components. The results of the simulations show the good response of the device, which enables to rapidly increase the power factor of the motor and maintains the Total Harmonic Distortion (THD ) of the injected phase voltages under the threshold value of 8%, as prescribed by CEI EN 50160 3.11.
Źródło:
Electrical Power Quality and Utilisation. Journal; 2007, 13, 2; 39-47
1896-4672
Pojawia się w:
Electrical Power Quality and Utilisation. Journal
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Non-Cartesian Frame Transformation-Based Control of a Three-Phase Power Converter During Unbalanced Voltage Dip – Part II: Simulation And Experiment
Autorzy:
Iwański, Grzegorz
Maciejewski, Paweł
Łuszczyk, Tomasz
Powiązania:
https://bibliotekanauki.pl/articles/1193687.pdf
Data publikacji:
2019
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
AC/DC
power conversion
current control
current limitation
Opis:
The paper presents a control method for the three-phase power converter operating under unbalanced grid voltage conditions. The method uses a new transformation to the non-Cartesian frame, which makes the controlled current vector components balanced in this frame even if originally the three-phase current is referenced as unbalanced. Furthermore, Park’s transformation makes the controlled variables constant, which allows to apply proportional–integral terms as current controllers independent of the required control target. Several control targets known from literature have been analyzed with regard to the required new transformation parameters, and the transformation parameters for all targets have been found. Simulation results are shown to prove the theoretical analysis, and the experimental test results are presented as practical validation of the proposed use of the non-Cartesian frame in control.
Źródło:
Power Electronics and Drives; 2019, 4, 39; 63-77
2451-0262
2543-4292
Pojawia się w:
Power Electronics and Drives
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Non-Cartesian Frame Transformation-Based Control of a Three-Phase Power Converter During Unbalanced Voltage Dip – Part I: Transformation Principles
Autorzy:
Iwański, Grzegorz
Maciejewski, Paweł
Łuszczyk, Tomasz
Powiązania:
https://bibliotekanauki.pl/articles/1193698.pdf
Data publikacji:
2019
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
AC/DC
power conversion
current control
Clarke's transformation
Opis:
One of the currently investigated problems in power electronics-based electrical energy conversion is proper operation of electronic converters during grid voltage imbalance and harmonics. In classic control methods, it introduces oscillations of variables, resulting in the necessity to improve control systems with signals filtration and usually by application of resonant terms as part of current controllers. The paper presents a new approach to grid-connected inverter control based on transformation to a non-Cartesian frame, the parameters of which are correlated with grid voltage asymmetry. The proposed method results in resignation from resonant terms used as controllers and their replacement with proportional–integral terms for which anti-wind-up structures are significantly simpler than for oscillatory terms. The paper presents new transformation principles, features and some simulation results showing the waveforms of signals transformed to the new non-Cartesian frame.
Źródło:
Power Electronics and Drives; 2019, 4, 39; 47-61
2451-0262
2543-4292
Pojawia się w:
Power Electronics and Drives
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
An Overview of Carrier-based Modulation Methods for Z-Source Inverter
Autorzy:
Roomi, Muhammad M.
Powiązania:
https://bibliotekanauki.pl/articles/1193846.pdf
Data publikacji:
2019
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
AC/DC
power conversion
impedance source inverter
modulation methods
shoot through
phase opposition disposition
reference disposition
Opis:
Single-stage energy converters, in particular, the Z-Source Inverter (ZSI) or impedance source inverter, has gained significant attention in the recent years. ZSI ensures flexible energy conversions (dc–dc, dc–ac, ac–ac and ac–dc) because of its unique ability to boost the output voltage in typical renewable energy systems. The impedance network integrated between the energy source and the load contributes to the unique functionality of the ZSI. As substantial research has been conducted on the ZSI, this article provides a review on the operation of ZSI. The article initially examines the various topologies commonly adopted for the application of the ZSI. Subsequently, details of the various modulation methods that are commonly used to obtain the voltage boosting using ZSI are documented. Additionally, the phenomenon of neutral point formation, which is an important impediment to the adoption of multilevel ZSIs and the limitation of the modulation methods, is explained.
Źródło:
Power Electronics and Drives; 2019, 4, 39; 15-31
2451-0262
2543-4292
Pojawia się w:
Power Electronics and Drives
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-4 z 4

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies