Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "ChzT" wg kryterium: Temat


Tytuł:
Effects of persulfate, peroxide activated persulfate and permanganate oxidation on treatability and biodegradability of leachate nanofiltration concentrate
Autorzy:
Guvenc, Senem Yazici
Varank, Gamze
Demir, Ahmet
Powiązania:
https://bibliotekanauki.pl/articles/2032960.pdf
Data publikacji:
2021
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
COD
nanofiltration
NF
ChZT
nanofiltracja
Opis:
The effects of persulfate (PS), peroxide activated persulfate (P-PS) and permanganate (PM) oxidation processes on leachate nanofiltration (NF) concentrate treatment have been activated. Additionally, COD fractions were determined and compared before and after each oxidation process. The total COD removal efficiencies by the oxidation processes using PS, P-PS, and PM as the oxidants were determined to be 24.5%, 32.9%, and 39.5%, respectively. The biodegradable COD fraction increased from 6.37% to 9.25%, 11.51%, and 13.64% after the PS, P-PS, and PM oxidation processes, respectively. About 25%, 34%, and 46% removal efficiencies of the inert COD content of the concentrate were obtained after the PS, P-PS and PM oxidation processes, and the soluble COD fraction increased from 71.1% to 87.2%, 89.0% and 84.6% by the PS, P-PS and PM oxidation processes, respectively. Although the highest removal efficiencies were achieved by PM oxidation with the lowest operational cost, all of the processes may be suggested as efficient methods for conversion of insoluble COD into the soluble COD fraction and for inert COD removal. The results of the study showed that the PS, P-PS, and PM oxidation processes may be effectively utilized as post-treatment techniques for leachate NF concentrate treatment.
Źródło:
Environment Protection Engineering; 2020, 46, 3; 97-108
0324-8828
Pojawia się w:
Environment Protection Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Modele biokinetyczne ASM
Biokinetic models ASM
Autorzy:
Sadecka, Z.
Płuciennik-Koropczuk, E.
Sieciechowicz, A.
Powiązania:
https://bibliotekanauki.pl/articles/372474.pdf
Data publikacji:
2011
Wydawca:
Uniwersytet Zielonogórski. Oficyna Wydawnicza
Tematy:
modele ASM
frakcje ChZT
ASM models
COD fractions
Opis:
W pracy przedstawiono ogólną charakterystykę modeli biokinetycznych typu ASM. W modelach uwzględnia się frakcje zanieczyszczeń biodegradowalnych i niebiodegradowalnych oraz rozpuszczonych i zawartych w zawiesinie. Podano charakterystykę frakcji ChZT oraz zakładane w modelach stężenia poszczególnych frakcji i ich procentowe udziały w ChZT całkowitym.
The paper presents the general characteristics of biokinetic models type ASM. The models take into account of the biodegradable and nonbiodegradable fraction soluble and contained in the suspension. In the article the characteristics of COD fractions and the concentrations of individual fractions and their percentage of the total COD is given.
Źródło:
Zeszyty Naukowe. Inżynieria Środowiska / Uniwersytet Zielonogórski; 2011, 141 (21); 113-125
1895-7323
Pojawia się w:
Zeszyty Naukowe. Inżynieria Środowiska / Uniwersytet Zielonogórski
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Bioremediation of fluazifop-p-butyl herbicide by some soil bacteria isolated from various regions of Turkey in an artificial agricultural field
Autorzy:
Erguven, Gokhan Onder
Nuhoglu, Yasar
Powiązania:
https://bibliotekanauki.pl/articles/2032953.pdf
Data publikacji:
2021
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
soil bacteria
COD
bioremediation
bakterie glebowe
ChZT
bioremediacja
Opis:
The bioremediation rate of fluazifop-p-butyl (C19H20F3NO4) was monitored. Bacteria were isolated in agricultural soil samples. Fifteen sterilised glass jars were inoculated with 2, 5, 10, 20 cm3 of a homogenised bacterial mixture (109 CFU/cm 3), then sterile agricultural soil and 60 μg of fluazifop-p-butyl (in liquid form) were added to each jar. Each week, filtrated water drained from bottles was analysed for fluazifop-p-butyl concentration, chemical oxygen demand (COD), biochemical oxygen demand (BOD5) and total organic carbon (TOC). Additionally, pH and dissolved oxygen concentration were monitored. The highest biodegradation rate was observed in the soil sample containing 20 cm 3 of the culture media. In this media, fluazifop-p-butyl, COD, BOD5 and TOC removals were measured as 91, 83, 96 and 86%, respectively, at the end of the 2 months. The DO level was measured between 3 and 6 mg O2/dm 3 in the first month for all cultures. An increase of pH was recorded during the first month and after this time a pH decrease was noted.
Źródło:
Environment Protection Engineering; 2020, 46, 3; 5-15
0324-8828
Pojawia się w:
Environment Protection Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Zastosowanie metody ChZT do oznaczania stężenia lecytyny w syntetycznym hydroksyapatycie
Application of the Chemical Oxygen Demand (COD) method for determining the amount of lecithin in synthetic hydroxyapatite
Autorzy:
Latocha, J.
Wojasiński, M.
Jeżak, J.
Matusiak, K.
Ciach, T.
Sobieszczuk, P.
Powiązania:
https://bibliotekanauki.pl/articles/2073354.pdf
Data publikacji:
2018
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
hydroksyapatyt
lecytyna
precypitacja
ChZT
hydroxyapatite
lecithin
precipitation
COD
Opis:
Badania dotyczyły zastosowania metody Chemicznego Zapotrzebowania Tlenu (ChZT) do oznaczenia ilości lecytyny związanej z hydroksyapatytem (HAp-LE), otrzymanym w procesie chemicznej precypitacji. Dokładność metody zweryfikowano wykonując bilans tlenu zużytego do całkowitego utlenienia lecytyny zawartej w mieszanie poreakcyjnej, osadzie oraz supematancie. Zawartość lecytyny w proszkach mieściła się w granicach od 1% do 30%. Zaproponowana metoda analityczna może być wykorzystywana do oznaczenia innych dodatków organicznych związanych z syntetycznym HAp.
The research concerned the application of the Chemical Oxygen Demand (COD) method lor determining the amount of lecithin bonded with hydroxyapatite (HAp-LE) obtained in the wet chemical precipitation process. The accuracy of method was verified using a balance of oxygen consumed to completely oxidize the lecithin contained in post-reaction mixture, precipitate and supernatant. The content of lecithin in obtained powders ranged from 1% to 30%. The proposed analytical method can be used in the determination of other organie additives bonded with synthetic HAp.
Źródło:
Inżynieria i Aparatura Chemiczna; 2018, 3; 67--68
0368-0827
Pojawia się w:
Inżynieria i Aparatura Chemiczna
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Ocena jakości wód Noteci na szlaku żeglugowym Nakło, Krzyż, Santok
An Opinion on the Water Quality of the River Noteć on the Nakło, Krzyż, Santok Navigational Route
Autorzy:
Jóźwiak, Z.
Bosy, A.
Gąsiorowska, M.
Grabia, M.
Banach, A.
Majewski, Ł.
Kilar, A.
Matkowska, K.
Powiązania:
https://bibliotekanauki.pl/articles/906896.pdf
Data publikacji:
2007
Wydawca:
Akademia Morska w Szczecinie. Wydawnictwo AMSz
Tematy:
Noteć
BZT
ChZT
OWO
Noteć River
BOD
COD
TOC
Opis:
W artykule przedstawiono wyniki badań wód Noteci, które przeprowadzono w okresie 18-30 sierpnia 2005 roku z pokładu statku szkolnego " W. Łokietek", w ramach działalności statutowej Naukowego Koła Ekologii przy AM w Szczecinie. Metodą spektrofotometrii UV (długość fal 205-320 nm) określono następujące wskaźniki: ogólny węgiel organiczny, chemiczne i biologiczne zapotrzebowanie tlenu, zawartość azotanów, zawiesiny ogólne oraz substancje powierzchniowo czynne.
The article presents the results of research on the cleanness of the River Noteć. The analysis was were executed in the period 18-30 August 2005 by students from the Scientific Circle of Ecology, Maritime University, in time of student training period on the ship "Wł. Łokietek". Using the method of spectrophotometer UV (205-320 nm length), the following indicators were qualifield: the total organic carbon, chemical oxygen demand, biological oxygen demand, content of nitrates, total suspended solids and surfactants.
Źródło:
Zeszyty Naukowe Akademii Morskiej w Szczecinie; 2007, 12 (84); 47-58
1733-8670
2392-0378
Pojawia się w:
Zeszyty Naukowe Akademii Morskiej w Szczecinie
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Biodegradacja serwatki koziej w bioreaktorze działającym w trybie ciągłym
Whey biodegradation in a continuous flow stirred tank reactor
Autorzy:
Lech, M.
Trusek-Hołownia, A.
Powiązania:
https://bibliotekanauki.pl/articles/2073173.pdf
Data publikacji:
2015
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
bioreaktor
serwatka
ChZT
B. licheniformis
biodegradacja
bioreactor
whey
COD
biodegradation
Opis:
Celem badań było opracowanie procesu biodegradacji serwatki w reaktorze mieszalnikowym, działającym w sposób ciągły. Opisano kinetykę wzrostu szczepu użytego do procesu równaniem Monoda ze stałymi Km = 0,45 kg m-3 i umax = 8,52-10-5 s-1. Potwierdzono również inhibicję substratową występującą powyżej stężenia 2 kg m-3 laktozy. Dobrany szczep skutecznie biodegraduje obecną w serwatce laktozę. Przy czasie przebywania w reaktorze wynoszącym 15 h odnotowuje się spadek stężenia laktozy do poziomu wymaga wymaganego przez nadzór ochrony środowiska.
The aim of this research was to elaborate the whey biodegradation process in a continuous flow stirred tank reactor. The kinetics of B. licheniformis growth was investigated and described by the Monod equation. The equation constants are as follows: Km = 0.45 kg m -3 and umax = 8.52-10-5 s-1. The substrate inhibition above the lactose concentration of 2 kg m-3 was also observed. The selected strain biodegrades effectively the whey waste. A decrease of lactose content to the level required by the Ministry of Environmental Protection for the residence time greater than 15 hrs was noticed.
Źródło:
Inżynieria i Aparatura Chemiczna; 2015, 4; 172--174
0368-0827
Pojawia się w:
Inżynieria i Aparatura Chemiczna
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Photochemical oxidation model of organic pollutants in greywater from a small household
Autorzy:
Bielski, Andrzej
Powiązania:
https://bibliotekanauki.pl/articles/207989.pdf
Data publikacji:
2020
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
COD
greywater
small household
ChZT
woda szara
małe gospodarstwo domowe
Opis:
The treatment of coagulated greywater from a small household was investigated. The processes of oxidation of organic compounds with hydrogen peroxide combined with ultraviolet radiation (H2O2/m3/UV) was described. Greywater with various initial COD and TOC concentrations was used in the H2O2/m3/UV process. The process parameters were hydrogen peroxide doses 0.5–4.0 kg H2O2/m3, UV (254 nm) light intensity 75.5 W/m2 and irradiation time – 1 h. The oxidation efficiency varied broadly from 15 to 98% and higher COD values corresponded to lower oxidation efficiencies. The average hydrogen peroxide consumption per kg of COD w was = 12.2 g H2O2/m3/g O2 COD, while per TOC it was w′ = 69.0 g H2O2/m3/g C. The experiments enabled one to developed mathematical models for coagulation and oxidation kinetics. The models showed that at the initial COD = 859 g O2/m3, the coagulant dose of 100 g Al3+/m3, the hydrogen peroxide dose of 4 kg H2O2/m3 and the UV irradiation time of 3 h it is possible to decrease the COD by 98.4%.
Źródło:
Environment Protection Engineering; 2020, 46, 1; 91-115
0324-8828
Pojawia się w:
Environment Protection Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Evaluation of integrated UFCW-MFC reactor for azo dye wastewater treatment and simultaneous bioelectricity generation
Autorzy:
Zou, Haiming
Chu, Lin
Wang, Yan
Powiązania:
https://bibliotekanauki.pl/articles/207646.pdf
Data publikacji:
2020
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
COD
UFCW-MFC
methyl orange
wastewater
ChZT
oranż metylowy
oczyszczanie ścieków
Opis:
An up-flow constructed wetland (UFCW) incorporating a novel membrane-less air-cathode single-chamber microbial fuel cell (MFC) was designed to treat dye wastewater and simultaneously generate bioelectricity. The performance of UFCW-MFC was evaluated via Methyl Orange (MO) and chemical oxygen demand (COD) removal rates and the output voltage. For comparison, the performance of a single UFCW was also assessed. A repeatable and stable voltage output of about 0.44±0.2 V was obtained in UFCW-MFC. The MO and COD removal rates in UFCW-MFC were 93.5 and 57.2%, respectively, significantly higher than those in single UFCW (75.4 and 42.6%, respectively), suggesting the obvious enhancement of electrodes on MO and COD removal. The anode zone of UFCW-MFC made the most contribution to MO and COD removal compared with other layers. The oxidation-reduction potential (ORP) and dissolved oxygen (DO) profiles showed that the anaerobic environment was well developed in the lower part of UFCW-MFC (0–24 cm) and the upper part (41–42 cm) had a good aerobic environment, thus greatly contributing to the MO anaerobic reduction and aerobic degradation of breakdown products. These results obtained here suggest that the UFCW-MFC may provide an effective alternative for the treatment of dye wastewater and simultaneous bioelectricity generation.
Źródło:
Environment Protection Engineering; 2020, 46, 1; 63-72
0324-8828
Pojawia się w:
Environment Protection Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Badanie możliwości procesowych obniżenia skażenia wód śródlądowych serwatką
Investigation on the possibility of whey contamination diminishing in inland water using the foam separation method
Autorzy:
Kawalec-Pietrenko, B.
Hołowacz, I.
Kucharska, K.
Powiązania:
https://bibliotekanauki.pl/articles/2070706.pdf
Data publikacji:
2009
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
serwatka
separacja pianowa
przebieg
ChZT
whey
foam separation
flotation course
COD
Opis:
Zaproponowano zastosowanie separacji pianowej do wydzielenia białek z serwatki. Zbadano wpływ pH, stężenia początkowego białek, prędkości przepływu powietrza oraz obecności addytywów na efektywność separacji białek serwatkowych w pólperiodycznej kolumnie bar-botażowej. Dla wybranych warunków badano także przebieg flotacji białek serwatkowych oraz wartość współczynnika ChZT
Foam separation was proposed for the removal of whey protein. The efficiency of foam separation in whey proteins' solutions was studied for various solution pH values, different concentration of solutions, different gas velocities and used additives. The flotation course of whey protein from the aqueous solution and COD factor were determined.
Źródło:
Inżynieria i Aparatura Chemiczna; 2009, 5; 51-52
0368-0827
Pojawia się w:
Inżynieria i Aparatura Chemiczna
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Treatment of effluent (skim latex serum) from a rubber processing plant with Fenton’s reagent
Autorzy:
Lim, Y. P.
El-Harbawi, M.
Yin, C.
Powiązania:
https://bibliotekanauki.pl/articles/208203.pdf
Data publikacji:
2017
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
ChZT
lateks
odczynnik Fentona
oczyszczanie ścieków
COD
Fenton's reagents
latex
sewage treatment
Opis:
The treatment effectiveness of Fenton's reagent using Fe2+catalyst to reduce chemical oxygen demand (COD) of skim latex serum and the effect of varying concentrations of H2O2, Fe2+and initial solution pH on its treatment efficiency were investigated. The highest COD removal efficiency obtained was approximately 80% at optimum conditions. The treatment required either nominal or no acidification as initial pH of serum is very close to the optimum pH = 4. COD removal increased upon increasing H2O2 and Fe2+concentrations. This study shows the suitability of using Fenton's process with H2O2and FeCh as a pre-Treatment for skim latex serum. The findings reported here represent a potentially simpler and more cost-effective alternative treatment to other treatment methods since only reagents and not capital-intensive materials (such as membrane) are required.
Źródło:
Environment Protection Engineering; 2017, 43, 3; 247-254
0324-8828
Pojawia się w:
Environment Protection Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Zahn-Wellens test in industrial wastewater biodegradability assessment
Test Zahn-Wellensa w ocenie biodegradowalności ścieków przemysłowych
Autorzy:
Płuciennik-Koropczuk, E.
Myszograj, S.
Powiązania:
https://bibliotekanauki.pl/articles/396597.pdf
Data publikacji:
2018
Wydawca:
Uniwersytet Zielonogórski. Oficyna Wydawnicza
Tematy:
COD
organic substances
industrial wastewater
liquids
ChZT
substancje organiczne
ścieki przemysłowe
odcieki
Opis:
Biodegradability of pollution contained in examined industrial wastewater was assessed according to methodology based on Zahn-Wellens (OECD 302B) test. The following kinds of wastewater were examined: metal industry wastewater from aluminium pressure foundry; wastewater from industrial waste treatment processes, such as: filtration waste, chemical reagents, coolants, water emulsions, oil wastes and other industrial wastes, galvanising waste treatment processes sludge. Samples COD value decrease in the subsequent days of the experiment proves that organic substances contained in the examined wastewater undergo gradual biodegradability in aerobic conditions. The highest biodegradability degree of aluminium pressure foundry wastewater equal 65.7% was noted during 28 day of the experiment. However, the minimum biodegradability degree equal 80% after 13 aeration days, which in Zahn-Wellens test allows to determine the examined substance to be biodegradable, has not been achieved. Meanwhile, Zahn-Wellens test conducted for wastewater from industrial waste treatment processes showed that in the day 14 of the process, high (87.1%) organic substance degradation degree, measured with COD value decrease, was achieved. Further aeration of the samples did not increase biodegradability, which equalled 87.9% after 28 days.
Podatność na biodegradację zanieczyszczeń zawartych w badanych ściekach przemysłowych oceniono zgodnie z metodyką opracowaną na podstawie testu OECD - Test Zahn–Wellens'a (OECD 302B). Badaniom poddano: ścieki z przemysłu metalowego z odlewni ciśnieniowej aluminium. W procesie produkcyjnym oprócz stopów aluminium wykorzystywane są środki smarne, oddzielacze od form, środki zapobiegające przyleganiu, substancje czyszczące oraz lakiery syntetyczne; odcieki z procesów unieszkodliwiania odpadów przemysłowych, takich jak: odpady pofiltracyjne, odczynniki chemiczne, chłodziwa, emulsje wodne, odpady olejowe i inne pochodzenia przemysłowego, osady z oczyszczania ścieków galwanizerskich. Zmniejszenie wartości ChZT w próbkach w kolejnych dobach prowadzenia testu świadczy o tym, że substancje organiczne zawarte w badanych ściekach ulegają stopniowej biodegradacji w warunkach tlenowych. Najwyższy stopień biodegradacji ścieków z odlewni ciśnieniowej aluminium wynoszący 65,7% stwierdzono w 28 dobie prowadzenia testu. Nie uzyskano jednak progu minimalnego stopnia biodegradacji wynoszącego 80% po 13 dobach napowietrzania, który w teście Zahn-Welens'a pozwala uznać badaną substancję za podatną na rozkład biologiczny. Natomiast test Zahn-Wellens'a przeprowadzony dla odcieków z procesów unieszkodliwiania odpadów przemysłowych wykazał, że w 14 dobie procesu uzyskano wysoki (87,1 %) stopień rozkładu substancji organicznej, mierzony obniżeniem wartości ChZT. Dalsze napowietrzanie próbek nie wpłynęło na zwiększenie biodegradacji i po 28 dobach wskaźnik ten wynosił 87,9%.
Źródło:
Civil and Environmental Engineering Reports; 2018, No. 28(1); 77-86
2080-5187
2450-8594
Pojawia się w:
Civil and Environmental Engineering Reports
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Badania podatności ścieków na rozkład biologiczny na przykładzie oczyszczalni pracującej w technologii sekwencyjno-przepływowej
The results of studies of wastewater susceptibility on biological decomposition on an example of waste water treatment plant operated in the sequential-flow technology
Autorzy:
Zdebik, D.
Głodniok, M.
Powiązania:
https://bibliotekanauki.pl/articles/372491.pdf
Data publikacji:
2011
Wydawca:
Uniwersytet Zielonogórski. Oficyna Wydawnicza
Tematy:
frakcje ChZT
technologia sekwencyjna
technologia przepływowa
COD fractions
sequential technology
flow technology
Opis:
W artykule opisano wyniki badań mających na celu określenie udziału frakcji ChZT w ściekach surowych, po oczyszczeniu mechanicznym oraz w ściekach oczyszczonych. Całkowite ChZT było analizowane w podziale na frakcję rozpuszczoną związków organicznych łatwo przyswajalnych, rozpuszczonych związków organicznych nierozkładalnych, zawiesin organicznych wolno rozkładalnych oraz zawiesin organicznych biologicznie nierozkładalnych. Omówiono zmiany udziału poszczególnych frakcji ChZT w ciągu doby. Przeprowadzone badania wykazały, że w części mechanicznej następuje duże zmniejszenie zawiesin organicznych wolno rozkładalnej frakcji ChZT, co ma wpływ na biologiczne procesy oczyszczania ścieków ze związków biogennych.
In this paper were described the results of research aimed at identifying the contribution fraction of COD in raw wastewater, after the mechanical treatment and in treated sewage. The total COD was analyzed by the fraction of dissolved organic compounds easily absorbed, persistent dissolved organic compounds, slowly degradable organic suspended solids and biologically non-degradable organic suspensions. Changes in the share of individual fractions of COD per day were discussed. The research indicated that in the mechanical part of WWTP provides a large reduction of organic suspensions - slowly biodegradable COD fraction, which affects the biological processes of reduction of biogenic compounds in wastewater.
Źródło:
Zeszyty Naukowe. Inżynieria Środowiska / Uniwersytet Zielonogórski; 2011, 141 (21); 54-65
1895-7323
Pojawia się w:
Zeszyty Naukowe. Inżynieria Środowiska / Uniwersytet Zielonogórski
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Performance evaluation of nanofiltration membranes for dye removal of synthetic hand-drawn batik industry wastewater
Autorzy:
Desiriani, Ria
Susanto, Heru
Aryanti, Nita
Powiązania:
https://bibliotekanauki.pl/articles/2057617.pdf
Data publikacji:
2022
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
COD
water filtration
nanofiltration
NF
batik industry
ChZT
filtracja wody
nanofiltracja
batik przemysłowy
Opis:
This study evaluated the performance of nanofiltration (NF) membrane for the treatment of hand-drawn batik wastewater containing synthetic dyes as well as real batik wastewater. Three commercial NF membranes (NF270, TS40 and XN45) were used. The effect of transmembrane pressure, NF membrane types, synthetic dyes concentration, and solution types on flux and rejection were investigated. The results showed that the use of all NF membranes could reach dye removal of ca. 99%. NF270 membrane exhibited the highest flux, 2–3 times higher than that of TS40 and XN45 membranes. NF270 membrane was further used for treating real batik wastewater. The results showed high rejections in terms of total suspended solids (TSS), chemical oxygen demand (COD), and total dissolved solids (TDS) were obtained. The practical applicability of NF270 membrane for real handdrawn batik wastewater treatment fulfilled the quality standards in terms of TSS, COD, and BOD parameters. Overall, the NF270 membrane showed favorable performance for batik effluent treatment.
Źródło:
Environment Protection Engineering; 2022, 48, 1; 51--68
0324-8828
Pojawia się w:
Environment Protection Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Zmiany udziału frakcji ChZT podczas oczyszczania ścieków komunalnych z dużym udziałem ścieków mleczarskich
Changes of COD fractions share during municipal wastewater treatment with big dairy wastewater participation
Autorzy:
Struk-Sokołowska, J.
Powiązania:
https://bibliotekanauki.pl/articles/1819467.pdf
Data publikacji:
2011
Wydawca:
Politechnika Koszalińska. Wydawnictwo Uczelniane
Tematy:
ścieki mleczarskie
ścieki komunalne
frakcja ChZT
dairy wastewater
municipal waste water
COD fraction
Opis:
Północno-wschodnia Polska jest regionem z największym pogłowiem krów mlecznych. Problem powstających tam ścieków mleczarskich i ich oczyszczania nadal nie jest do końca rozwiązany. Dlatego celowym wydało się podjęcie badań nad intensyfikacją procesu oczyszczania ścieków komunalnych z dużym udziałem ścieków mleczarskich. W tym celu określono zmiany frakcji ChZT w ściekach surowych oraz po kolejnych etapach mechaniczno-biologicznego oczyszczania ścieków komunalnych z dużym udziałem ścieków z przemysłu mleczarskiego.
Development of our civilization has caused that urban centres have been deprived of natural retention system especially referring to rainwater. Present sewage systems, in most cases is not able to carry away a great intensity of sewage flow. Therefore, different technical interventions are undertaken in order to catch and keep this surplus of flow temporarily. Sewage transfer to receivers problem is solved in different way in each country. There are well-known solutions of either stationary or moving sewage pumping stations. However, most often outflow of excessive rainwater is performed gravitationally through outflow collectors linking storm overflows with water receiver. The outlet of these outflow collectors is usually equipped with shut-off check valve in order to protect terrains against flooding. However, practically these valves are not always used, whereas they are installed, are usu-ally deprived of proper care and preservation. Thus, their technical state make impossible for these valves to work. A research on practical ways of transfer sewage from the protected drain-age area to the receiver during the periods of high fillings has not brought a uni-versal and unfailing solution, which could have a wide application in practice. So the problem of working out a solution of hydraulic way of carrying away the rainwater to the receiver assure their natural, gravitational outflow during the periods of either low states and medium fillings in the receiver or during the period of high fillings their strained transfer. This kind of solution of transfer of rainwater to the water receiver are transfer reservoirs. A common solving feature of these reservoirs is that they are located on the side of drained terrain. This solution guarantees possible damage repairs even when in the receiver - river high states of filling appears. Transfer reservoirs can be applied in the following cases: (a) in separate sewage system on the outlets of the main collectors of the rainfall system, (b) in combined sewage system on the outlets of a storm canal, (c) in combined sewage system on the outlets of storm canals with simultaneous pumping of domestic and industrial wastewater to a wastewater treatment plant, (d) in case of collectors carrying away treated sewage from the wastewater treatment plant. In the paper transfer reservoir GEMINUS is presented. Transfer of sew-age, using this kind of reservoir, is done through applying system of air-compressors and proper combination of pressure systems.
Źródło:
Rocznik Ochrona Środowiska; 2011, Tom 13; 2015-2032
1506-218X
Pojawia się w:
Rocznik Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Evaluation of influence of coagulation/flocculation and Fenton oxidation with iron on landfill leachate treatment
Autorzy:
Smaoui, Yosr
Mseddi, Salma
Ayadi, Najla
Sayadi, Sami
Bouzid, Jalel
Powiązania:
https://bibliotekanauki.pl/articles/207405.pdf
Data publikacji:
2019
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
COD
coagulation
Fenton process
groundwater pollution
ChZT
koagulacja
proces Fentona
zanieczyszczenie wód gruntowych
Opis:
Landfill leachates (LFL) collected from Sfax (Tunisia) discharge area are characterized by high chemical oxygen demand (COD), ammonium and salts contents. They constitute a source of phytotoxicity and pollution for ground water and surface water resources which requires an adequate treatment process. To evaluate the efficiency of the coagulation/flocculation treatment, special attention was paid to the effect of pH, coagulant and flocculant doses. Then, effect of zero valent iron was also studied alone and in combination with coagulation/flocculation pretreatment. Our results indicate high removal efficiencies by coagulation/flocculation (46% COD and 63% turbidity) and Fenton process (48% COD and 76% turbidity). The combined application of coagulation/flocculation and Fenton revealed higher COD removal (62%) and turbidity reduction (90%). These results showed the applicability of this combined treatment method for the degradation of organic compounds and reduction of the treated leachate toxicity.
Źródło:
Environment Protection Engineering; 2019, 45, 1; 139-153
0324-8828
Pojawia się w:
Environment Protection Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
COD fractions - methods of measurement and use in wastewater treatment technology
Frakcje CHZT - metody pomiaru oraz zastosowanie w technologii oczyszczania ścieków
Autorzy:
Myszograj, S.
Płuciennik-Koropczuk, E.
Jakubaszek, A.
Świętek, A.
Powiązania:
https://bibliotekanauki.pl/articles/396702.pdf
Data publikacji:
2017
Wydawca:
Uniwersytet Zielonogórski. Oficyna Wydawnicza
Tematy:
COD fractions
raw wastewater
methods of measurement
frakcje ChZT
ścieki surowe
metody pomiaru
Opis:
The paper presents the results of studies concerning the designation of COD fraction in raw wastewater. The research was conducted in four municipal mechanical-biological sewage treatment plants and one industrial sewage treatment plant. The following fractions of COD were determined: non-biodegradable (inert) soluble SI, biodegradable soluble fraction SS, particulate slowly degradable XS and particulate non-biodegradable XI. The methodology for determining the COD fraction was based on the ATV-A131 guidelines and Łomotowski-Szpindor methodology. The real concentration of fractions in raw wastewater and the percentage of each fraction in total COD are different from data reported in the literature.
W artykule przedstawiono wyniki badań, których celem było wyznaczanie frakcji ChZT w ściekach surowych. Badania przeprowadzono w czterech komunalnych mechaniczno-biologicznych oczyszczalniach ścieków i oczyszczalni ścieków przemysłowych. Określono następujące frakcje ChZT: inertna rozpuszczona SI, biodegradowalna rozpuszczona SS, związana w zawiesinie biologicznie łatworozkładalnej XS i związana w zawiesinie nieulegająca biodegradacji XI. Metodologia określania frakcji ChZT została oparta na wytycznych ATV-A131 i metodologii Łomotowskiego-Szpindora. Uzyskany udział frakcji w całkowitym ChZT w ściekach surowych różnił się od danych literaturowych.
Źródło:
Civil and Environmental Engineering Reports; 2017, No. 24(1); 197-208
2080-5187
2450-8594
Pojawia się w:
Civil and Environmental Engineering Reports
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Estimation of Chemical Oxygen Demand Fractions of Municipal Wastewater by Respirometric Method – Case Study
Wyznaczenie frakcji ChZT w ściekach komunalnych z wykorzystaniem metody respirometrycznej
Autorzy:
Szaja, A.
Aguilar, J. A.
Łagód, G.
Powiązania:
https://bibliotekanauki.pl/articles/1818557.pdf
Data publikacji:
2015
Wydawca:
Politechnika Koszalińska. Wydawnictwo Uczelniane
Tematy:
COD fractions
organic matter
wastewater plant simulation models
frakcje ChZT
materia organiczna
modele symulacyjne
Opis:
Jednym z ważniejszych problemów z punktu widzenia sterowania pracą oczyszczalni ścieków jest posiadanie kompletnych i dokładnych informacji na temat jakości ścieków. Do oceny parametrów jakościowych ścieków stosowane jest określanie udziałów frakcyjnych chemicznego zapotrzebowania na tlen (ChZT) pod względem właściwości fizycznych oraz podatności na biodegradację. Informacja na temat udziałów frakcyjnych ChZT może być wykorzystywana w modelowaniu pracy systemów oczyszczania ścieków jak również modelowania procesów transportu i biodegradacji zanieczyszczeń w systemach kanalizacyjnych. Opracowanie prezentuje wyniki badań udziałów frakcyjnych ścieków dopływających do miejskiej oczyszczalni ścieków w Maladze (Hiszpania). Ścieki surowe dopływały do kolektora zbiorczego z różnych dzielnic miasta kolektorami oznaczonymi jako A, B oraz C, natomiast kolektorem D doprowadzane były wody z gospodarki osadowej, zawracane na początek procesu technologicznego oczyszczalni. Do wyznaczenia udziałów frakcyjnych ChZT w analizowanych próbkach ścieków wykorzystane zostały metody respirometryczne. W przypadku ścieków surowych największy udział w całkowitym ChZT miała frakcja biodegradowalna, 47–57% przypadało na frakcje szybko ulegające biodegradacji, natomiast 13 do 16% na frakcje wolno ulegające biodegradacji. Odcieki z urządzeń gospodarki osadowej charakteryzowały się znacznym udziałem frakcji nieulegających biodegradacji, przy czym 69% przypadało na frakcje w postaci zawiesiny, natomiast 6,7% w postaci rozpuszczonej.
Źródło:
Rocznik Ochrona Środowiska; 2015, Tom 17, cz. 1; 289-299
1506-218X
Pojawia się w:
Rocznik Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Effect of internal recycle ratio on the denitrification process and nirS-containing bacteria of an anaerobic/anoxic/oxic (A2/O) wastewater treatment process
Autorzy:
Yan, Xu
Zheng, Jiaxi
Han, Yunping
Liu, Jianwei
Sun, Jianhui
Powiązania:
https://bibliotekanauki.pl/articles/207970.pdf
Data publikacji:
2019
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
COD
wastewater treatment
denitrification process
internal recycle
ChzT
oczyszczanie ścieków
proces denitryfikacji
recykling wewnętrzny
Opis:
Internal recycle (IR) ratio is an important operation parameter for the anaerobic/anoxic/oxic (A2O) wastewater treatment process. Three laboratory-scale A2O wastewater treatment processes with IR ratios 100%, 200%, and 300% were set up to study its influence on the denitrification process and nirS gene-containing bacteria. Results showed theremoval rate of chemical oxygen demand (COD), ammonia nitrogen (NH4 +-N), total nitrogen (TN) and total phosphorus (TP) increased at different levels as the IR rate augmented from 100% to 300%. NirS gene numbers were increased from 1.8×108 to 3.2×108 copies/g MLSS, which was positively correlated with the denitrification rate in anoxic areas. Moreover, similarities were observed in the community structures of denitrifying bacteria that contained the nirS gene under different operation modes. These results indicated that increasing the IR rate in the A2O treatment process could benefit nirS gene-containing bacteria and improve denitrification ability observably while maintaining the stability of the community structure of the system.
Źródło:
Environment Protection Engineering; 2019, 45, 3; 87-101
0324-8828
Pojawia się w:
Environment Protection Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Zastosowanie haloizytu w celu zmniejszenia stężenia zanieczyszczeń w ściekach komunalnych
The use of halloysite to reduce pollutions concentration in municipal wastewater
Autorzy:
Machnicka, A.
Nowicka, E.
Powiązania:
https://bibliotekanauki.pl/articles/400716.pdf
Data publikacji:
2016
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
haloizyt
obciążenie hydrauliczne
fosforany
azot amonowy
ChZT
halloysite
hydraulic load
phosphates
ammonia nitrogen
COD
Opis:
Jedna z metod oczyszczania ścieków komunalnych pozwala na zastosowanie złóż biologicznych. W badaniach zastosowano złoże wypełnione haloizytem. Podczas pracy złoża w zależności od zastosowanego obciążenia hydraulicznego uzyskano redukcję stężeń fosforanów, azotu amonowego i materii organicznej. Najwyższą redukcję PO43- (89%) i N–NH4+ (81%) w ściekach uzyskano przy obciążeniu hydraulicznym złoża wynoszącym 0,04 m3/m2h. Stężenie substratu organicznego uległo redukcji o ok. 86%.
One of the methods of municipal wastewater treatment allows the use of biofilters. The study used a bed filled halloysite. In operation of the bed, depending on the hydraulic load, the concentration of phosphate, ammonium and organic matter was reduced. Highest reduction of the concentration PO43- (89%) and NH4+ (81%) in the waste water of the hydraulic load –0,04 m3/m2h.was obtained. The concentration of the organic substrate was reduced by approximately 86%.
Źródło:
Inżynieria Ekologiczna; 2016, 50; 217-222
2081-139X
2392-0629
Pojawia się w:
Inżynieria Ekologiczna
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Artificial neural network (ANN) modeling of COD reduction from landfill leachate by the ultrasonic process
Autorzy:
Arabameri, M.
Javid, A.
Roudbari, A.
Powiązania:
https://bibliotekanauki.pl/articles/207474.pdf
Data publikacji:
2017
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
COD
neural network
landfill leachate
ultrasonic process
ChZT
sieć neuronowa
odciek ze składowiska
proces ultradźwiękowy
Opis:
In the study, the use of an artificial neural network (ANN) has been applied for the prediction of COD removal from landfill leachate by the ultrasonic process. The configuration of the backpropagation neural network giving the lowest mean square error (MSE) was a three-layer ANN with a tangent sigmoid transfer function (tansig) at a hidden layer with 14 neurons, linear transfer function (purelin) at the output layer and the Levenberg–Marquardt backpropagation training algorithm (LMA). The ANN predicted results are very close to the experimental data with the correlation coefficient (R2) of 0.992 and the MSE of 0.000331. The sensitivity analysis showed that all studied variables (contact time, pH, ultrasound frequency and power) have strong effect on COD removal. In addition, ultrasound power is the most influential parameter with relative importance of 25.8%. The results showed that modeling neural network could effectively predict COD removal from landfill leachate by ultrasonic process.
Źródło:
Environment Protection Engineering; 2017, 43, 1; 59-73
0324-8828
Pojawia się w:
Environment Protection Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Methods of processing whey waste from dairies. A review
Autorzy:
Ponist, Juraj
Dubsikova, Veronika
Schwarz, Marian
Samesova, Dagmar
Powiązania:
https://bibliotekanauki.pl/articles/2032849.pdf
Data publikacji:
2021
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
whey
aerobic process
dairy waste
BOD
COD
serwatka
proces tlenowy
odpady z mleczarni
ChZT
BZT
Opis:
The purpose of the study was to evaluate the methods of processing whey. The valorization method is suitable for the use of cheese whey and whey permeate to produce beverages with or without microbial conversion. However, this method does not ensure microbial conversion of lactose. Therefore, the organic load will not be reduced. The main advantage of aerobic decomposition is the relatively rapid degradation of organic matter. However, the high organic load in the crude cheese whey makes aerobic decomposition unsuitable and restrictions on oxygen transport may occur. Anaerobic decomposition can be used in various areas for the treatment of waste with a high organic load. The disadvantage of anaerobic processes is a higher cost compared to aerobic treatment. The combination of individual technologies significantly reduces the hydraulic retention time of the aerobic process and improves waste treatment. At present, there is a lack of studies in this area.
Źródło:
Environment Protection Engineering; 2021, 47, 4; 67-84
0324-8828
Pojawia się w:
Environment Protection Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Effects of zero-valent iron and enzymes on the anaerobic co-digestion of sewage sludge and corn silage
Autorzy:
Zhou, Haidong
Cao, Zhengcao
Ying, Zhenxi
Liu, Jicheng
Hu, Tao
Zhang, Mingquan
Zhang, Jingyuan
Powiązania:
https://bibliotekanauki.pl/articles/2032872.pdf
Data publikacji:
2020
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
corn silage
COD
sewage sludge
anaerobic digestion
kiszonka z kukurydzy
ChZT
osad ściekowy
beztlenowa fermentacja
Opis:
Anaerobic co-digestion of sewage sludge and corn silage with zero-valent iron powder (Fe0), cellulase, and papain as reinforcement means was conducted. COD-based feeding ratio of sewage sludge to corn silage was set to 2:1, the solids retention time (SRT) 20 day, digestion temperature 35 °C, and mixing speed 60 rpm. Removal rates of total COD during the control group, and Fe0, papain, cellulase, and papain, Fe0, and the two kinds of enzyme-added tests were 38.04, 41.02, 34.62, 34.55, 35.42, and 48.21%, respectively. The corresponding biogas production was 2.12, 2.62, 2.22, 2.41, 2.25, and 2.81 dm3/day, respectively. The results indicated the addition of cellulase, and papain could maximize the decomposition and hydrolysis of organic matter in sewage sludge and corn silage to volatile fatty acids. Fe0 could reduce the redox potentials of the anaerobic co-digestion, optimize the circumstances of the methanogenesis stage, accelerate biogas production, and improve biogas components. Fe0 and enzymes played a synergistic role in the anaerobic co-digestion system. Life cycle assessment indicated that the anaerobic co-digestion of sludge and corn silage co-substrates could benefit the economy, environment, and social development under the synergistic action of Fe0 and enzymes.
Źródło:
Environment Protection Engineering; 2020, 46, 4; 41-56
0324-8828
Pojawia się w:
Environment Protection Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Effects of zero-valent iron and enzymes on the anaerobic co-digestion of sewage sludge and corn silage
Autorzy:
Zhou, Haidong
Cao, Zhengcao
Ying, Zhenxi
Liu, Jicheng
Hu, Tao
Zhang, Mingquan
Zhang, Jingyuan
Powiązania:
https://bibliotekanauki.pl/articles/2032890.pdf
Data publikacji:
2020
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
corn silage
COD
sewage sludge
anaerobic digestion
kiszonka z kukurydzy
ChzT
osad ściekowy
beztlenowa fermentacja
Opis:
Anaerobic co-digestion of sewage sludge and corn silage with zero-valent iron powder (Fe0), cellulase, and papain as reinforcement means was conducted. COD-based feeding ratio of sewage sludge to corn silage was set to 2:1, the solids retention time (SRT) 20 day, digestion temperature 35 °C, and mixing speed 60 rpm. Removal rates of total COD during the control group, and Fe0, papain, cellulase, and papain, Fe0, and the two kinds of enzyme-added tests were 38.04, 41.02, 34.62, 34.55, 35.42, and 48.21%, respectively. The corresponding biogas production was 2.12, 2.62, 2.22, 2.41, 2.25, and 2.81 dm3/day, respectively. The results indicated the addition of cellulase, and papain could maximize the decomposition and hydrolysis of organic matter in sewage sludge and corn silage to volatile fatty acids. Fe0 could reduce the redox potentials of the anaerobic co-digestion, optimize the circumstances of the methanogenesis stage, accelerate biogas production, and improve biogas components. Fe0 and enzymes played a synergistic role in the anaerobic co-digestion system. Life cycle assessment indicated that the anaerobic co-digestion of sludge and corn silage co-substrates could benefit the economy, environment, and social development under the synergistic action of Fe0 and enzymes.
Źródło:
Environment Protection Engineering; 2020, 46, 4; 41-56
0324-8828
Pojawia się w:
Environment Protection Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Zmiany składu materii organicznej podczas oczyszczania ścieków komunalnych
Changes in organic matter composition during municipal sewage treatment
Autorzy:
Przywara, L.
Adamiec, A.
Powiązania:
https://bibliotekanauki.pl/articles/127545.pdf
Data publikacji:
2017
Wydawca:
Towarzystwo Chemii i Inżynierii Ekologicznej
Tematy:
materia organiczna
frakcje ChZT
wody odpadowe
przeróbka osadów
odcieki
organic matter
COD fractions
reject water
Opis:
Efektywność oczyszczania ścieków zależy nie tylko od zastosowanej technologii dostosowanej do jakości dopływających ścieków surowych, ale również od problemów eksploatacyjnych czy gospodarki wodami osadowymi. Obecnie oczyszczalnie nie stosują metod wydzielonego oczyszczania odcieków powstających w trakcie przeróbki osadów i są zawracane na początek ciągu technologicznego oczyszczalni. Wody osadowe ze względu na zawartość substancji organicznej niepodatnej na biodegradację mogą wpływać na efektywność realizowanych procesów oczyszczania. Dlatego też ważne jest nie tylko określenie ogólnej zawartości związków organicznych w ściekach, ale również dokonanie szczegółowej charakterystyki substancji organicznych przez wyznaczenie frakcji ChZT. W niniejszych badaniach przeanalizowano przemiany materii organicznej podczas oczyszczania ścieków w kolejnych etapach mechaniczno-biologicznego oczyszczania ścieków, dokonując analizy składu frakcyjnego materii organicznej. Badania prowadzono na ściekach pochodzących z oczyszczalni pracującej w technologii zintegrowanego usuwania związków organicznych i biogennych. Wykazano m.in., że cyrkulacja odcieków powstających podczas odwadniania osadów powodowała wzrost stężenia trudno rozkładalnej substancji organicznej. Podczas mechaniczno-biologicznego procesu oczyszczania całkowicie uległy zmianie proporcje frakcji Si, Ss, Xi, Xs. Dominującą frakcją w ściekach oczyszczonych była frakcja związków rozpuszczonych nieulegających biologicznemu rozkładowi przez mikroorganizmy - Si. Łącznie frakcje inertne (Si i Xi) w ściekach oczyszczonych stanowiły 76,4% całkowitego ChZT. Udział frakcji Xi na poziomie 16,3% całkowitego ChZT w ściekach oczyszczonych pozwala stwierdzić, że zachodzące procesy oczyszczania działają z dużą efektywnością, na które nie mają wpływu doprowadzane wody osadowe.
Efficiency of wastewater treatment depends not only on the applied technology of wastewater treated, but also on processing problems and management of reject water. Currently, treatment plants do not use methods of separate treatment of reject water generated during the processing of sludge and such residues are returned to the beginning of technological process of treatment. Reject water due to the content of non-biodegradable organic matter can affect the efficiency of the purification process. Therefore, it is important not only to determine the overall content of organic compounds in wastewater, but also the specific characteristics of organic substances, by determining of COD fractions. In this study, fractional composition of organic matter during wastewater treatment in the subsequent stages of mechanical and biological wastewater treatment was analyzed. The wastewater used originated from the plant using integrated removal of organic and biogenic compounds. The circulation of reject water formed during dewatering of sediments, resulted in an increase in the concentration of the hardlybiodegradable organic matter. During mechanical/biological phase of wastewater treatment, the proportions of Si, Ss, Xi, Xs fractions were completely changed. The dominant fraction in purified effluents was a fraction of dissolved and non-biodegradable compounds Si. In total, Si and Xi inert fractions in purified effluent accounted for 76% of the total COD. The fraction of Xi, in purified effluent, in case of processes not influenced by recirculated reject water, amounted for 16% of the total COD. This shows that the cleaning processes occurs with high effectiveness.
Źródło:
Proceedings of ECOpole; 2017, 11, 2; 571-580
1898-617X
2084-4557
Pojawia się w:
Proceedings of ECOpole
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The Influence of the Poles’ Lifestyle on the Quantity and Quality of Municipal Wastewater
Autorzy:
Płuciennik-Koropczuk, Ewelina
Myszograj, Martyna
Myszograj, Sylwia
Powiązania:
https://bibliotekanauki.pl/articles/2051694.pdf
Data publikacji:
2021
Wydawca:
Uniwersytet Zielonogórski. Oficyna Wydawnicza
Tematy:
municipal wastewater
wastewater characteristics
biodegradability
COD fractionation
PPCPs
ścieki komunalne
charakterystyka ścieków
biodegradowalność
frakcjonowanie ChZT
Opis:
The article presents lifestyle as an important factor determining the quantity and quality of municipal wastewater. The characteristic of wastewater in Poland has changed significantly in recent years. The qualitative characteristics of municipal wastewater indicate an increase of organic compounds and in the scope of micro-contaminants identified in them, e.g. nanoparticles, microplastics, pharmaceutical and personal care products or heavy metals. Therefore, the knowledge of parameters such as: BOD5, COD, total N, total P and suspension solids is no longer sufficient for the design and operation of wastewater treatment systems. Comprehensive research in this area is necessary to select those indicators that better describe the characteristics of wastewater.
Źródło:
Civil and Environmental Engineering Reports; 2021, 31, 3; 265-275
2080-5187
2450-8594
Pojawia się w:
Civil and Environmental Engineering Reports
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies