Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "CR" wg kryterium: Temat


Tytuł:
Lung Cancer Risk Due to Radon in Different Brand Cigarette Tobacco in Iraqi Market
Autorzy:
Abdalsattar, Kareem Hashim
Ahmed Najam, Ahmed Najam
Abbas, Fadhel Hadi
Fadhil, Khaddam fuliful
Powiązania:
https://bibliotekanauki.pl/articles/1178355.pdf
Data publikacji:
2017
Wydawca:
Przedsiębiorstwo Wydawnictw Naukowych Darwin / Scientific Publishing House DARWIN
Tematy:
CR-39
Radon
effective dose
lung cancer
nuclear track detectors
tobacco
Opis:
Sealed can technique using CR-39 plastic track detector strippable has been used in order to measure radon concentrations to calculate the annual effective dose and lung cancer cases per year per million person for twenty different brand tobacco cigarette were collected from Iraqi market. Lung cancer is the leading cause of cancer-related deaths worldwide. Radon exposure is the second leading cause of lung cancer, following tobacco smoke. Radon is not only an independent risk factor; it also increases the risk of lung cancer in smokers. It has been observed that tobacco smoking increases the risks of radon-induced lung cancer. Radon and cigarette smoking have synergistic, multiplicative effect on lung cancer rates. People who inhale tobacco smoke are exposed to higher concentrations of radioactivity. Ever since studies on the relation of smoking to cancer, particularly the lung cancer has been established, there had been a great interest in studies concerned with the monitoring of the alpha radioactivity in tobacco. The results showed that the 222Rn concentrations in cigarette tobacco samples ranged from (156.450 to 403.087) Bq/m3 with an average 284.751 Bq/m3, while the radon induced lung cancer risks was found to vary from 71.047 to 183.049 with an av¬erage value of 129.3107 per million person, and standard deviation 83.529 and 37.932, respectively. Excellent correlation has been observed between radon concentration and lung cancer cases per year per million person for different brand tobacco cigarettes.
Źródło:
World Scientific News; 2017, 77, 2; 163-176
2392-2192
Pojawia się w:
World Scientific News
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Barite Effect on Radiation Shielding Properties of Cotton-Polyester Fabric
Autorzy:
Akkurt, İ.
Emikönel, S.
Akarslan, F.
Günoğlu, K.
Kilinçarslan, Ş.
Üncü, İ.
Powiązania:
https://bibliotekanauki.pl/articles/1402530.pdf
Data publikacji:
2015-08
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Tematy:
42.82.Cr
81.05.-t
Opis:
Since creation of universe there has been radiation around us and this rate is getting higher with the development of technology. Thus radiation shielding becomes important subject for researcher. Besides normal people especially radiation workers in nuclear facilities need extra protection from radiation. This is vital if we think about any kind of nuclear leakage or nuclear attack, fabric becomes very important. For this purpose, cotton-polyester type of fabric has been coated by barite and gamma ray attenuation efficient has been obtained. The fabric was coated in different rate of barite (0%, 40%, 50% and 60%) in order to test effect of barite rate on the fabric. The measurement has been performed for gamma ray energy of 511, 662, and 835 keV using gamma spectrometer system with NaI(Tl) detector. It was found that the attenuation coefficient has increased with the barite coating rate on fabric.
Źródło:
Acta Physica Polonica A; 2015, 128, 2B; B-53-B-54
0587-4246
1898-794X
Pojawia się w:
Acta Physica Polonica A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Magnetic Ordering of RAgSb$\text{}_{2}$ Compounds
Autorzy:
André, G.
Bourée, F.
Kolenda, M.
Leśniewska, B.
Oleś, A.
Szytuła, A.
Powiązania:
https://bibliotekanauki.pl/articles/2013392.pdf
Data publikacji:
2000-05
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Tematy:
75.30.Cr
75.30.Kz
75.50.Ee
Opis:
The magnetic structures of the polycrystalline samples of RAgSb$\text{}_{2}$ (R=Ce, Pr, Nd, Tb-Tm) are determined. All compounds crystallize in the tetragonal ZrCuSi$\text{}_{2}$-type of crystal structure and except CeAgSb$\text{}_{2}$ they are antiferromagnets with a Néel temperature of 11 K for R = Tb and 2 K for Tm. CeAgSb$\text{}_{2}$ below T$\text{}_{C}$=9.5 K is ferromagnet with the magnetic moment equal to 0.33μ$\text{}_{B}$ and parallel to c-axis. In NdAgSb$\text{}_{2}$ the sine modulated magnetic ordering described by the wave vector k = (0.5435,0,0) is observed. Below T$\text{}_{N}$ a collinear antiferromagnetic structure with the magnetic (a,a,2c) for R = Pr and (2a,a,c) for R = Tb, Dy, Ho, and Er is observed. For Ho-compound with an increase in temperature the coexistence of two structures is observed: commensurate collinear and incommensurate sine modulated. In TmAgSb$\text{}_{2}$ the coexistence of the two phases is observed at T = 1.4 K. With an increase in temperature only the incommensurate phase stays.zapisz i
Źródło:
Acta Physica Polonica A; 2000, 97, 5; 771-774
0587-4246
1898-794X
Pojawia się w:
Acta Physica Polonica A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The power impact of electric power assist in hybrid vehicle
Autorzy:
Andrych-Zalewska, M.
Chmielewska, P.
Wróbel, R.
Powiązania:
https://bibliotekanauki.pl/articles/242222.pdf
Data publikacji:
2017
Wydawca:
Instytut Techniczny Wojsk Lotniczych
Tematy:
hybrid vehicle
Honda CR-Z
electric motor
Opis:
The current interest in the development of hybrid vehicles is a response to serious effects of road transport on the environment over recent years. In addition, vehicles equipped with this type of drive combine the advantages of a conventional diesel engine and electric motor. This results in higher system efficiency while reducing emissivity. This work seeks to demonstrate the effect of electric power on the total power of a hybrid vehicle. The research on the chassis dynamometer (MAHA LPS 3000) of the hybrid sports car, Honda CRZ, has been performed in three modes of operation: normal, economical and sport. The obtained results are presented in the form of graphs of external engine characteristics, where the influence of electric power on the system is visible. The tested vehicle is equipped with sixth version of Honda’s Integrated Motor Assist (IMA) technology, which is the crucial system, assisting the combustion engine in order to provide higher performance and better fuel economy.
Źródło:
Journal of KONES; 2017, 24, 4; 17-24
1231-4005
2354-0133
Pojawia się w:
Journal of KONES
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Effect of adding furnace ash from bituminous coal combustion to soil on phytoavailability of selected metals
Wpływ dodatku popiołu paleniskowego z węgla kamiennego do gleby na fitoprzyswajalność wybranych metali
Autorzy:
Antonkiewicz, J.
Jasiewicz, C.
Kępka, W.
Kowalewska, A.
Pełka, R.
Losak, T.
Hlusek, J.
Powiązania:
https://bibliotekanauki.pl/articles/296897.pdf
Data publikacji:
2015
Wydawca:
Politechnika Częstochowska. Wydawnictwo Politechniki Częstochowskiej
Tematy:
ash
Cr
Mn
Fe
Ni
Cu
Al
maize
tolerance index
metal translocation factor
metal content
metal uptake
popiół
kukurydza
indeks tolerancji plonu
wskaźnik translokacji metali
zawartość metali
pobranie metali
Opis:
The research on the effect of furnace ash from bituminous coal combustion on the uptake of Cr, Cu, Ni, Fe, Mn, Al by maize (Zea mays L.) was conducted under conditions of a three-year pot experiment. The arable soil in the pot experiment was amended with furnace ash in the amount of 23.33 g·pot‒1 (corresponding to 20 t·ha‒1) and with increasing doses of cadmium (3÷15 mg·kg‒1 soil DM). Application of ash and cadmium in the amount of 3÷5 mg·kg‒1 DM to the soil had a significant effect on the increase in the yield of above-ground parts and roots of maize. Application of subsequent doses of cadmium (7.5÷15 mg·kg‒1) caused a considerable reduction in the yield of the tested plant. The research shows that the applied furnace ash reduced the depression in yielding of maize. Introduction of furnace ash to cadmium-contaminated soil caused an increase in the content of Cr, Fe, Ni, Cu and Al in maize biomass and a decrease in the content of Mn in maize. Among the studied metals, Mn was translocated from roots to above-ground parts the most efficiently, and Al - the least efficiently, evidence of which are the highest values of the translocation factor for Mn, and the lowest values for Al. The research showed that ash introduced to cadmium-contaminated soil did not immobilize the above-mentioned metals, and thereby did not reduce the phytoavailability. In general, contamination of the soil with cadmium and introduction of ash stimulated uptake of the metals by maize. We observed that roots took up more Cr, Fe, Ni and Al, whereas above-ground parts of maize took up more Mn and Cu. The lowest uptake of the studied metals by maize was observed in the treatment where only furnace ash was applied.
Badania nad wpływem popiołu paleniskowego z węgla kamiennego na pobieranie Cr, Cu, Ni, Fe, Mn, Al przez kukurydzę (Zea mays L.) przeprowadzono w warunkach trzyletniego doświadczenia wazonowego. W doświadczeniu wazonowym zastosowano do gleby uprawnej popiół paleniskowy, w ilości 23,33 g·wazon‒1, odpowiadającej 20 t·ha‒1, oraz wzrastające dawki kadmu, w ilości 3÷15 mg·kg‒1 s.m. gleby. Zastosowanie popiołu oraz kadmu w ilości 3÷5 mg·kg‒1 s.m. do gleby wpłynęło istotnie na zwiększenie plonu części nadziemnych i korzeni kukurydzy. Natomiast zaaplikowanie kolejnych dawek kadmu (7,5÷15 mg·kg‒1) spowodowało istotne obniżenie plonu testowanej rośliny. Z badań wynika, że zaaplikowany popiół paleniskowy zmniejszył depresję plonowania kukurydzy. Wprowadzenie popiołu paleniskowego do gleby zanieczyszczonej kadmem wpłynęło na zwiększenie zawartości Cr, Fe, Ni, Cu i Al w biomasie kukurydzy, natomiast wpłynęło na zmniejszenie zawartości Mn w kukurydzy. Spośród badanych metali najłatwiej był przemieszczany z korzeni do części nadziemnych Mn, a najsłabiej Al, o czym świadczą największe wartości współczynnika translokacji dla Mn, a najmniejsze wartości dla Al. Z badań wynika, że popiół wprowadzony do gleby zanieczyszczonej kadmem nie wpłynął na immobilizację wyżej wymienionych metali, a tym samym nie ograniczył fitoprzyswajalności. Generalnie zanieczyszczenie gleby kadmem i wprowadzenie popiołu stymulowało pobieranie metali przez kukurydzę. Stwierdzono większe pobranie Cr, Fe, Ni i Al przez korzenie, natomiast Mn i Cu przez części nadziemne kukurydzy. Najmniejsze pobranie badanych metali przez kukurydzę zarejestrowano w obiekcie, w którym zastosowano wyłącznie popiół paleniskowy.
Źródło:
Inżynieria i Ochrona Środowiska; 2015, 18, 4; 405-422
1505-3695
2391-7253
Pojawia się w:
Inżynieria i Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Magnetic Susceptibility of Cd$\text{}_{1-x}$Fe$\text{}_{x}$Te$\text{}_{1-y}$Se$\text{}_{y}$
Autorzy:
Arciszewska, M.
Mycielski, A.
Dobrowolski, W.
Lenard, A.
Mauger, A.
Witkowska, B.
Powiązania:
https://bibliotekanauki.pl/articles/1890693.pdf
Data publikacji:
1991-08
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Tematy:
72.80.Ey
75.20.Hr
75.30.Cr
Opis:
Magnetic susceptibility of Cd$\text{}_{1-x}$Fe$\text{}_{x}$Te$\text{}_{1-y}$Se$\text{}_{y}$ was found to consist of Van Vleck term (characteristic for the Fe$\text{}^{2+}$ centers in tetrahedral crystal symmetry) and temperature-dependent contribution. The occurrence of the latter indicates an existence of additional magnetic moments. We ascribe their origin to the modification of the Fe$\text{}^{2+}$ energy level spectrum induced by mixed Te-Se anion environment.
Źródło:
Acta Physica Polonica A; 1991, 80, 2; 303-306
0587-4246
1898-794X
Pojawia się w:
Acta Physica Polonica A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Magnetic Susceptibility Studies of Fe-Doped II-VI Compounds
Autorzy:
Arciszewska, M.
Powiązania:
https://bibliotekanauki.pl/articles/1886787.pdf
Data publikacji:
1991-02
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Tematy:
75.20.Hr
72.80.Ey
75.30.Cr
Opis:
Low-field magnetic susceptibility χ of Fe-doped II-VI compounds has been studied for wide iron concentration range (3 x 10$\text{}^{18}$ ≤ N$\text{}_{Fe}$ ≤ 10$\text{}^{21}$ cm$\text{}^{-3}$). For the low iron content the Van Vleck-type paramagnetism is observed at low temperatures in all investigated materials (except for Hg$\text{}_{1-x}$Fe$\text{}_{x}$Se), which entirely confirms the theoretical prediction. For the higher Fe contents the experimental data still remain unexplained.
Źródło:
Acta Physica Polonica A; 1991, 79, 2-3; 341-344
0587-4246
1898-794X
Pojawia się w:
Acta Physica Polonica A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Provenance of Albian to Cenomanian exotics-bearing turbidites in the Western Carpathians : a heavy mineral analysis
Autorzy:
Aubrecht, Roman
Bellová, Simona
Mikuš, Tomáš
Powiązania:
https://bibliotekanauki.pl/articles/2060270.pdf
Data publikacji:
2020
Wydawca:
Państwowy Instytut Geologiczny – Państwowy Instytut Badawczy
Tematy:
ophiolites
Cr-spinel
blue amphibole
tourmaline
pyroxene
Cretaceous palaeogeography
Opis:
Throughout the Cretaceous, Tethyan oceanic branches gradually closed, and various ophiolites became obducted and eroded. Their remnants, however, provide an abundance of exotic clasts of unknown origin. Sandstone samples from the oldest, Albian exotics-bearing strata of the Pieniny Klippen Belt and Central Western Carpathians were analysed for heavy minerals. These samples were dominated by a high content of chrome-spinels, zircon, tourmaline, apatite and rutile. Titanite, kyanite, monazite, epidote, sillimanite and staurolite were much less abundant. Garnet was generally also rare; however, it was locally common, as were blue amphiboles, pyroxenes and kyanite. The spinels found in the samples were predominantly derived from harzburgites (supra-subduction peridotites and volcanic rocks). The blue amphiboles represented glaucophanes to ferroglaucophanes, and were derived from HP/LT metabasites. Pyroxenes (enstatite, less commonly augite and diopside) most likely came from coeval volcanics. Most of the tourmalines were derived from metasedimentary rocks and locally from granitoids. Furthermore, some have a complex zonation with two phases of tourmaline, or tourmaline intergrown with quartz. These were likely derived from ophiolitic sources. The results from our analysis indicate a dominance of ophiolites and older sediments with local input of continental crust metamorphic rocks. A resulting palaeogeographic reconstruction involves secondary doubling of the Neotethys suture zone and its lateral shift north of the Central Western Carpathians, which formed a common source for exotics in the Pieniny Klippen Belt and the Central Western Carpathians.
Źródło:
Geological Quarterly; 2020, 64, 3; 658--680
1641-7291
Pojawia się w:
Geological Quarterly
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Effect of Remelting of the Ni-22Cr-9Mo Alloy on its Microstructural and Electrochemical Properties
Autorzy:
Augustyn-Nadzieja, J.
Łukaszczyk, A.
Loch, J.
Powiązania:
https://bibliotekanauki.pl/articles/351218.pdf
Data publikacji:
2017
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
Ni-Cr-Mo alloys
metal prosthetics restorations
method melted models
artificial saliva solution
corrosion resistance
Opis:
The Ni-Cr-Mo alloys are used as the alternative for the cobalt alloys in the manufacture of metal prosthetic elements, i.e. crowns, bridges and frame prostheses. The article attempts at a materials science characterization of the nickel-based alloy of the commercial name Argeloy N.P Be-Free by Argen. Within the study, examinations were made on the commercial alloy as well as the alloy which was remelted and cast by the los mould (lost wax) method. Observations of the microstructure were performed with the use of optical and electron scanning microscopy. Also, X-ray structural tests were conducted as well as corrosion resistance tests in an artificial saliva solution (pH = 6,7). It was demonstrated that the examined Ni-22Cr-9Mo alloy characterized in a dendritic structure typical of the cast materials. The X-ray qualitative phase analysis revealed the phase γ'(Ni) in both examined materials, as well as the presence of Cr23C6 type carbides and Nb2C, Ta2C (commercial alloy) and NbC, Ta4C0,04 (cast alloy) phases. The effect of the alloy’s remelting and the morphology of the passive layer on the corrosion resistance of the Ni-Cr-Mo alloy was examined. The results of the electrochemical tests show that the process of re-casting only slightly affects the corrosion resistance and the microstructure of the considered alloy. The roles of recasting process and the passive film homogeneity on the corrosion resistance of Ni-Cr-Mo dental alloy were reviewed. The results the electrochemical study show that the dependence of corrosion resistance on the microstructure associated with the recasting process is marginal.
Źródło:
Archives of Metallurgy and Materials; 2017, 62, 1; 411-418
1733-3490
Pojawia się w:
Archives of Metallurgy and Materials
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The effect of heat treatment on the microstructure and properties of the corrosion resistance of the prosthetic alloy Wironit ExtraHart (Co-Cr-Mo)
Wpływ obróbki cieplnej na mikrostrukturę i odporność korozyjną protetycznego stopu Wironit ExtraHart (Co-Cr-Mo)
Autorzy:
Augustyn-Nadzieja, J.
Pełka, S.
Loch-Zawrotniak, J.
Powiązania:
https://bibliotekanauki.pl/articles/263988.pdf
Data publikacji:
2018
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie. Wydawnictwo AGH
Tematy:
Co-Cr-Mo alloys
heat treatment
dendritic microstructure
corrosion resistance
stopy CoCrMo
obróbka cieplna
mikrostruktura dendrytyczna
odporność korozyjna
Opis:
The presented study performs an analysis of the effect of thermal treatment on the microstructure and corrosion resistance of the commercial prosthetic alloy Wironit ExtraHart (Co-Cr-Mo). Experiments of thermal treatment, homogenization, oversaturation as well as oversaturation with ageing of the alloys were carried out. Metallographic tests, hardness measurements, EDS analyses and electrochemical investigations were performed. For the examined samples, the corrosion potential (OCP) and polarization curve (LSV) were determined, based on which the corrosion properties in the simulated solution of artificial saliva were established. The results of the obtained tests made it possible to evaluate the effect of the performed thermal treatment on the changes in the properties (hardness) as well as the microstructure and corrosion resistance of the examined alloy Co-Cr-Mo.
W pracy dokonano analizy wpływu obróbki cieplnej na mikrostrukturę i odporność korozyjną komercyjnego stopu protetycznego Wironit ExtraHart (Co-Cr-Mo). Przeprowadzono eksperyment obróbki cieplnej stopów, wyżarzania ujednorodniającego, przesycania i przesycania ze starzeniem. Wykonano badania metalograficzne, analizę EDS oraz badania elektrochemiczne. Dla badanych próbek wyznaczono potencjał korozyjny (OCP) oraz krzywą polaryzacji (LSV), na podstawie których określono właściwości korozyjne w symulowanym roztworze sztucznej śliny. Wyniki otrzymanych badań pozwoliły stwierdzić wpływ przeprowadzonej obróbki cieplnej na zmiany własności (twardość) i mikrostrukturę oraz odporność korozyjną badanego stopu Co-Cr-Mo.
Źródło:
Metallurgy and Foundry Engineering; 2018, 44, 4; 181-193
1230-2325
2300-8377
Pojawia się w:
Metallurgy and Foundry Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analysis of properties and tribological wear of the Co-Cr alloys used for prosthetic constructions
Analiza własności i zużycia tribologicznego stopów z układu Co-Cr stosowanych na konstrukcje protetyczne
Autorzy:
Augustyn-Nadzieja, Joanna
Frocisz, Łukasz
Krawczyk, Janusz
Pańcikiewicz, Krzysztof
Powiązania:
https://bibliotekanauki.pl/articles/189312.pdf
Data publikacji:
2019
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
stopy Co-Cr-Mo-W
mikrostruktura
zużycie ścierne
konstrukcje protetyczne
Co-Cr-Mo-W alloys
microstructure
abrasive wear
prosthetic constructions
Opis:
W opracowaniu zaprezentowano wyniki badań zużycia tribologicznego protetycznych odlewniczych stopów Co-Cr z mikrododatkami Mo i W. Badania odporności na zużycie ścierne wykonano przy użyciu testera T-05 w układzie trącym rolka–klocek, które przeprowadzono w styku ślizgowym suchym w warunkach kontaktu metal–metal. Dokonano jakościowej i ilościowej oceny mikrostruktury stopów w korelacji z twardością i ich zużyciem ściernym. Analiza odporności na zużycie ścierne badanych stopów obejmowała analizę takich parametrów jak, relatywny ubytek masy próbki, średnia wartość współczynnika tarcia oraz głębokość wytarcia. Stwierdzono, że badane stopy Co-Cr-Mo-W charakteryzują się niską wartością średniego współczynnika tarcia, niezależną od czasu trwania próby tribologicznej, co wskazuje na brak zmian mechanizmu zużywania wraz ze wzrostem czasu trwania próby. Odporność na zużycie ścierne badanych materiałów związana była z morfologią faz obserwowanych w mikrostrukturze stopów po procesie krzepnięcia. Podobna szerokość obszarów międzydendrytycznych skutkuje podobnym stopniem zużycia masowego badanych materiałów.
The paper presents the results of investigations performed in the scope of the tribological wear of prosthetic cast alloys Co-Cr with micro-additions Mo and W. Abrasive wear resistance tests were carried out by means of a T-05 tester in the roller-block friction system in dry sliding metal-metal contact. A qualitative and quantitative evaluation of the alloy microstructure was made in correlation with hardness and abrasive wear. The analysis of the abrasive wear resistance of the examined alloys included an analysis of such parameters as the relative mass loss of the sample, the mean friction coefficient value, and the wear depth. It was established that the examined alloys Co-Cr-Mo-W are characterize by a low value of the friction coefficient, independent of the tribological test duration, which points to the lack of changes in the wear mechanism with the increase of the test duration time. The abrasive wear resistance of the tested materials are related to the morphology of the phases at the alloys microstructure after the solidification. A similar width of the interdendritic areas results in a similar degree of mass loss for the examined materials.
Źródło:
Tribologia; 2019, 287, 5; 5-12
0208-7774
Pojawia się w:
Tribologia
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The influence of prosthetic elements manufacturing technology on properties and microstructure shaping Co-Cr-Mo alloys
Autorzy:
Augustyn-Nadzieja, Joanna
Szczotok, Agnieszka
Powiązania:
https://bibliotekanauki.pl/articles/1844979.pdf
Data publikacji:
2020
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie. Polskie Towarzystwo Biominerałów
Tematy:
Co-Cr-Mo alloys
dental prosthetics
lost wax casting method
selective laser sintering of metal powders (DLMS)
microstructure
hardness
Opis:
The presented publication discusses the test results regarding samples of a prosthetic alloy from the Co-Cr-Mo system. The test samples were obtained by means of two different methods applied in prosthetics laboratories to compare their properties and microstructure. To obtain the samples via the traditional lost wax casting method, the cast alloy Co-Cr-Mo was used, commercially known as Wironit LA. In the case of the modern technique DMLS (Direct Metal Laser Sintering), metallic powder Co-Cr-Mo, called EOS Cobalt Chrome MP1, was used. The samples of both Co-Cr-Mo alloys obtained via the two methods were prepared for metallographic tests; they also underwent microstructural observations with the use of light microscopy (LM) and scanning electron microscopy (SEM), and next they were subjected to hardness tests. The obtained samples demonstrated a dendritic structure. In the samples cast with the lost wax casting method, a segregation of the chemical composition was revealed. The samples obtained by means of the DLMS method were characterized by chemical composition homogeneity. The hardness measurements with the statistical analysis of the measurement results showed a difference between the examined alloys. On the basis of the performed studies, it was stated that the applied methods of manufacturing prosthetic elements make it possible to obtain diversified microstructural and mechanical properties of the alloys. The hardness value significantly affects the subsequent mechanical and finishing treatment of prosthetic elements, such as metal bases of crown caps, bridges, mobile prostheses or other retention elements.
Źródło:
Engineering of Biomaterials; 2020, 23, 156; 24-31
1429-7248
Pojawia się w:
Engineering of Biomaterials
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Selected properties and tribological wear alloys Co-Cr-Mo and Co-Cr-Mo-W used in dental prosthetics
Wybrane właściwości oraz zużycie tribologiczne stopów, Co-Cr-Mo i Co-Cr-Mo-w stosowanych w protetyce stomatologicznej
Autorzy:
Augustyn-Pieniążek, J.
Kurtyka, P.
Sulima, I.
Stopka, J.
Powiązania:
https://bibliotekanauki.pl/articles/356345.pdf
Data publikacji:
2015
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
Co-Cr alloys
wear
slurry abrasion test (“Miller test”)
dental prosthetics
Co-Cr stopy
zużycie
badanie zużycia ściernego stopów
aparat Millera
protetyka stomatologiczna
Opis:
The presented work provides the results of the abrasive wear resistance tests performed on Co-Cr-Mo and Co-Cr-Mo-W alloys with the use of the Miller’s apparatus. The analyzed alloys underwent microstructure observations as well as hardness measurements, and the abraded surfaces of the examined materials were observed by means of electron scanning microscopy. The performed examinations made it possible to state that the Co-Cr alloys characterized in a high hardness, whereas the changes in the mass decrement were minimal, which proved a high abrasive wear resistance.
W prezentowanej pracy przedstawiono wyniki badań zużycia ściernego stopów, Co-Cr-Mo i Co-Cr-Mo-W przy użyciu aparatu Millera. Analizowane stopy poddano obserwacjom mikrostruktury, pomiarom twardości i mikrotwardości, a ścierane powierzchnie badanych materiałów obserwacji przy wykorzystaniu elektronowej mikroskopii skaningowej. Przeprowadzone badania pozwoliły na stwierdzenie, że stopy, Co-Cr charakteryzowały się wysoką twardością i mikrotwardością, zaś zmiany ubytku masy były bardzo minimalne, co świadczy o wysokiej odporności na ścieranie.
Źródło:
Archives of Metallurgy and Materials; 2015, 60, 3A; 1569-1574
1733-3490
Pojawia się w:
Archives of Metallurgy and Materials
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Właściwości ścierne stopów Co-Cr w zawiesinie ceramika-sztuczna ślina
Abrasive behaviour of Co-Cr alloys in the ceramic material-artificial saliva suspension
Autorzy:
Augustyn-Pieniążek, J.
Kurtyka, P.
Stopka, J.
Powiązania:
https://bibliotekanauki.pl/articles/284452.pdf
Data publikacji:
2014
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie. Polskie Towarzystwo Biominerałów
Tematy:
stopy Co-Cr
testy zużycia ściernego w zawiesinie
protetyka stomatologiczna
Co-Cr alloys
abrasive wear tests in suspension
prosthodontics
Opis:
Publikacja zawiera wyniki badań odporności na ścieranie stopów Co-Cr-Mo i Co-Cr-Mo-W przeprowadzonych na aparacie Millera. W celu oceny podatności na zużycie ścierne w naturalnych warunkach pracy w/w stopów, badania prowadzono w specjalnie zasymulowanym środowisku, składającym się z ceramicznego proszku Dentyna oraz roztworu sztucznej śliny o pH równym 6,7. W ramach badań przeprowadzono obserwacje mikrostruktury przy wykorzystaniu mikroskopu świetlnego stosując kontrast interferencyjno--różniczkowy (kontrast Nomarskiego), wykonano pomiary twardości, zaś powierzchnie po procesie ścierania poddano obserwacji przy wykorzystaniu elektronowej mikroskopii skaningowej. Na postawie przeprowadzonych badań stwierdzono, że stopy Co-Cr-Mo i Co-Cr-Mo-W charakteryzują się wysoką twardością około 400-450 HV10 i minimalnym ubytkiem masy w procesie ścierania. Cechy te świadczą o wysokiej odporności na ścieranie badanych stopów w środowisku proszek ceramiczny-sztuczna ślina. Dodatkowo stwierdzono również, że trzy z badanych stopów Remanium 2001, Colado CC oraz Heraenium P w odróżnieniu od stopu Wironit LA, posiadają przystanki na krzywych ubytku masy w czasie związane z różnicami twardości materiału osnowy β-Co, wydzieleń węglikowych oraz ramion dendrytów. W przypadku stopu Wironit LA obserwowano równomierne zużycie materiału na całej powierzchni. Stwierdzono również, że pomimo różnic w mechanizmach ścierania pomiędzy stopem Wironit LA I Remanium 2001 wielkość ubytku masy jest dla nich na podobnym poziomie, jednak jest ona znacznie niższa niż dla pozostałych dwóch badanych stopów Colado CC ora Heraenium P.
The publication contains the results of the abrasion resistance tests carried out on Co-Cr-Mo and Co-Cr--Mo-W alloys using Miller apparatus. To assess the susceptibility to abrasive wear of the above mentioned alloys under natural operating conditions, tests were carried out in a specially simulated environment, consisting of a ceramic Dentine powder and artificial saliva solution with pH of 6.7. The scope of studies included the examinations of microstructure performed by light microscopy using differential interference contrast (Nomarski contrast), measurements of hardness, and SEM examinations of surfaces after the abrasion process. The results of these studies enabled formulating the conclusion that alloys from the Co-Cr-Mo and Co-Cr-Mo-W systems are characterised by high hardness of about 400-450 HV10 and minimum weight loss in the process of abrasion. These features prove high abrasive wear resistance of the examined alloys in the environment of ceramic powder and artificial saliva. Additionally, it was also found that three of the tested alloys, i.e. Remanium 2001, Colado CC and Heraenium P, unlike the Wironit LA alloy, show time-related arrests on the weight loss curves caused by different hardness values of the β-Co matrix, carbide precipitates and dendrite arms. The Wironit LA alloy was observed to wear evenly across the whole surface. It was also found that, despite differences in abrasion mechanism operating in the Wironit LA and Remanium 2001 alloys, the magnitude of weight loss has been similar and, at the same time, much lower than for the other two alloys tested, i.e. Colado CC and Heraenium P.
Źródło:
Engineering of Biomaterials; 2014, 17, 127; 7-15
1429-7248
Pojawia się w:
Engineering of Biomaterials
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Neutral and Charged Excitons Localized in the InAs/GaAs Wetting Layer
Autorzy:
Babiński, A.
Czyż, M.
Golnik, A.
Borysiuk, J.
Kret, S.
Raymond, S.
Lapointe, J.
Wasilewski, Z.
Powiązania:
https://bibliotekanauki.pl/articles/1811914.pdf
Data publikacji:
2008-11
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Tematy:
73.21.La
78.55.Cr
78.67.Hc
Opis:
It has recently been shown that potential fluctuations in a wetting layer, which accompanies InAs/GaAs quantum dots can localize excitons. Neutral excitons and biexcitons and charged excitons were identified. In this communication we report on studies of properties of the excitons over wide temperature range (T < 70 K). The micro-photoluminescence measurements enable investigation of excitons localized in a single potential fluctuation. Temperature-induced broadening of the neutral exciton as well as a quenching of the charged exciton at temperatures higher than 50 K are observed and discussed.
Źródło:
Acta Physica Polonica A; 2008, 114, 5; 1055-1060
0587-4246
1898-794X
Pojawia się w:
Acta Physica Polonica A
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies