Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "Buildings" wg kryterium: Temat


Tytuł:
Diagnostics and Repairs of Damage of the Leaning Tower in Zabkowice Slaskie
Autorzy:
Abel, Tomasz
Powiązania:
https://bibliotekanauki.pl/articles/2051597.pdf
Data publikacji:
2021
Wydawca:
Uniwersytet Zielonogórski. Oficyna Wydawnicza
Tematy:
masonry structures
repair of damages
micropiles
belfry
leaning tower
historic buildings
Ząbkowice Śląskie
konstrukcje murowane
naprawy
mikropale
dzwonnica
krzywa wieża
historyczne budynki
Opis:
The article concerns the diagnosis of the technical condition, as well as the possibilities of renovating, the Leaning Tower located in Zabkowice Slaskie in Lower Silesia, Poland. Damage to the structure of the facility, which occurred in 2015, constituted the basis for carrying out tests and measurements in order to enable the causes of the damage to be determined. The resulting damage is cracks in brick walls. Cracks were formed in the place where the proper structure of the Tower was connected with the staircase constituting the extension of the building. Therefore, it was necessary to carry out diagnostic work. The conducted diagnostic works resulted in the obtaining of knowledge about the technical condition of the facility, and the possibilities of the necessary repair works, which will ensure the further safe operation of the facility. It was considered necessary to stabilize the ground under the staircase by making micropiles. Cracks in the walls were stabilized by making steel ties, rebuilt and reinforced with steel bars. The Leaning Tower, as a historic and unique building in Europe, requires special technical supervision, which will guarantee that it remains in its prime for many years to come and continue to be one of the key tourist attractions of Zabkowice Slaskie.
Źródło:
Civil and Environmental Engineering Reports; 2021, 31, 3; 197-210
2080-5187
2450-8594
Pojawia się w:
Civil and Environmental Engineering Reports
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Sistemy energosberezenia s aktivnoj rekuperaciej tepla i vlagi dla energopassivnych zdanij
Energy saving systems with active heat and moisture recovery for passive buildings
Autorzy:
Achmarov, T. A.
Spiridonov, A. V.
Subin, I. L.
Powiązania:
https://bibliotekanauki.pl/articles/2065401.pdf
Data publikacji:
2015
Wydawca:
Politechnika Częstochowska
Tematy:
systemy energooszczędne
budynki pasywne
odzyskiwanie ciepła
active energy saving systems
passive buildings
recovery heat
Opis:
V stat’e predstavleny sistemy aktivnogo energosberezenia (SAE). K SAE otnosatsa sistemy, kotorye ispol’zuut vtoricnye energoresursy, netradicionnye i vozobnovlaemye istocniki energii, a takze avtoregulirovanie pri izmenenii uslovij snaruzi i vnutri zdanij.
The paper presents the active power system. This system includes secondary energy resources, alternative and renewable energy sources, as well as autoregulation conditions change on the outside and inside buildings.
Źródło:
Budownictwo o Zoptymalizowanym Potencjale Energetycznym; 2015, 1 (15); 22--32
2299-8535
2544-963X
Pojawia się w:
Budownictwo o Zoptymalizowanym Potencjale Energetycznym
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Certyfikacja energetyczna budynków w świetle nowych uregulowań prawnych
Energy certification of buildings in the light of the new legal framework
Autorzy:
Adamczyk, J.
Powiązania:
https://bibliotekanauki.pl/articles/113504.pdf
Data publikacji:
2015
Wydawca:
STE GROUP
Tematy:
certyfikat energetyczny
ustawa o charakterystyce energetycznej budynków
efektywność energetyczna
energy certificate
law on the energy performance of buildings
energy efficiency
Opis:
Certyfikat energetyczny dostarcza istotnych informacji na temat przegród budowlanych, instalacji centralnego ogrzewania, ciepłej wody użytkowej, wewnętrznych zysków energii, itp. Informacje te są istotne w kontekście zapotrzebowania budynku na energię cieplną. W artykule wskazano argumenty, które przemawiają za dokonanymi w "nowej" ustawie zmianami legislacyjnymi w systemie certyfikacji energetycznej budynków, ale również wykazano braki. Celem artykułu było zaprezentowanie zmian zapisów legislacyjnych poczynionych pod koniec 2014 roku w zakresie certyfikacji energetycznej budynków.
The energy certificate provides relevant information on the building partitions, central heating, hot water, internal energy gains, etc. This information is important in the context of the building's thermal energy. The article indicates arguments that speak for made in the "new" law legislative changes in the system of energy certification of buildings, but also demonstrated shortcomings. The purpose of the article was to present legislative records changes made at the end of 2014, energy certification of buildings.
Źródło:
Systemy Wspomagania w Inżynierii Produkcji; 2015, 3 (12); 9-16
2391-9361
Pojawia się w:
Systemy Wspomagania w Inżynierii Produkcji
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Monitorowanie wpływu drgań od pojazdów szynowych na konstrukcje inżynierskie
Monitoring of vibration caused by railway vehicles on engineering facilities
Autorzy:
Adamczyk, J.
Bednarz, J.
Targosz, J.
Powiązania:
https://bibliotekanauki.pl/articles/311710.pdf
Data publikacji:
2013
Wydawca:
Instytut Naukowo-Wydawniczy "SPATIUM"
Tematy:
drgania od pojazdów szynowych
drgania budynków
monitoring drgań
vibration of railway vehicles
buildings vibrations
vibration monitoring
Opis:
W pracy przedstawiono i omówiono dwie możliwe metody monitorowania drgań wywołanych pojazdami szynowymi. Wskazano na pewne wady i zalety obu tych systemów i zaprezentowano możliwość zastosowania MES do wykonania monitoringu drgań tych pojazdów w celu określenia ich wpływu na konstrukcje i obiekty inżynierskie.
In the paper two possible methods of monitoring vibrations caused by rail vehicles are presented. Some advantages and disadvantages of both of these systems are discussed and the possibility of using FEM is demonstrated to perform vibration monitoring of these vehicles in order to determine their impact on the engineering facilities.
Źródło:
Autobusy : technika, eksploatacja, systemy transportowe; 2013, 14, 3; 1709-1716
1509-5878
2450-7725
Pojawia się w:
Autobusy : technika, eksploatacja, systemy transportowe
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Halophilic microorganisms in deteriorated historic buildings: insights into their characteristics
Autorzy:
Adamiak, Justyna
Otlewska, Anna
Gutarowska, Beata
Pietrzak, Anna
Powiązania:
https://bibliotekanauki.pl/articles/1038823.pdf
Data publikacji:
2016
Wydawca:
Polskie Towarzystwo Biochemiczne
Tematy:
halophilic microorganisms
historic buildings
phenotypic characteristics
biodeterioration
Opis:
Historic buildings are constantly being exposed to numerous climatic changes such as damp and rainwater. Water migration into and out of the material's pores can lead to salt precipitation and the so-called efflorescence. The structure of the material may be seriously threatened by salt crystallization. A huge pressure is produced when salt hydrates occupy larger spaces, which leads at the end to cracking, detachment and material loss. Halophilic microorganisms have the ability to adapt to high salinity because of the mechanisms of inorganic salt (KCl or NaCl) accumulation in their cells at concentrations isotonic to the environment, or compatible solutes uptake or synthesis. In this study, we focused our attention on the determination of optimal growth conditions of halophilic microorganisms isolated from historical buildings in terms of salinity, pH and temperature ranges, as well as biochemical properties and antagonistic abilities. Halophilic microorganisms studied in this paper could be categorized as a halotolerant group, as they grow in the absence of NaCl, as well as tolerate higher salt concentrations (Staphylococcus succinus, Virgibacillus halodenitrificans). Halophilic microorganisms have been also observed (Halobacillus styriensis, H. hunanensis, H. naozhouensis, H. litoralis, Marinococcus halophilus and yeast Sterigmatomyces halophilus). With respect to their physiological characteristics, cultivation at a temperature of 25-30°C, pH 6-7, NaCl concentration for halotolerant and halophilic microorganisms, 0-10% and 15-30%, respectively, provides the most convenient conditions. Halophiles described in this study displayed lipolytic, glycolytic and proteolytic activities. Staphylococcus succinus and Marinococcus halophilus showed strong antagonistic potential towards bacteria from the Bacillus genus, while Halobacillus litoralis displayed an inhibiting ability against other halophiles.
Źródło:
Acta Biochimica Polonica; 2016, 63, 2; 335-341
0001-527X
Pojawia się w:
Acta Biochimica Polonica
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Problemy zarządzania miejscem światowego dziedzictwa UNESCO na przykładzie planu zarządzania dla kościołów pokoju w Jaworze i Świdnicy
Management Plans for the Churches of Peace in Jawor and Swidnica as an Example of Management Problems with UNESCO World Heritage Site
Autorzy:
Affelt, Waldemar J.
Powiązania:
https://bibliotekanauki.pl/articles/114010.pdf
Data publikacji:
2017
Wydawca:
Politechnika Lubelska. Polski Komitet Narodowy Międzynarodowej Rady Ochrony Zabytków
Tematy:
światowe dziedzictwo UNESCO
zarządzanie światowym dziedzictwem
kościoły luterańskie
drewniane ramy
UNESCO world heritage
cultural heritage management
Lutheran churches
wooden framed buildings
Opis:
A research and educational project “The Churches of Peace in Jawor and Swidnica. World Heritage Site. Management Plan” was carried out between 2012–2014 as part of Polish – German collaboration. It was based upon a textbook published by German Commission for UNESCO. This article presents the principles thereof as well as discusses the results and conclusions coming from the project. Other reference publications dealing with cultural heritage issued after 2014 have been included as well.
Źródło:
Ochrona Dziedzictwa Kulturowego; 2017, 4; 105-120
2543-6422
Pojawia się w:
Ochrona Dziedzictwa Kulturowego
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Dokumenty programujące rozwój miasta Pionki a jego uwarunkowania krajobrazowe
The documents containing development plans for Pionki town and the existing landscape
Autorzy:
Agajew, Maria
Powiązania:
https://bibliotekanauki.pl/articles/87982.pdf
Data publikacji:
2008
Wydawca:
Polskie Towarzystwo Geograficzne
Tematy:
Pionki
rewitalizacja
tereny poprzemysłowe
plany miejscowe
revitalization
post-industrial buildings
development plans
Opis:
W obecnym okresie wiele polskich miasteczek w mniejszym lub większym stopniu wymaga rewitalizacji. Elementem, który w wielu przypadkach może stać się dźwignią dla poprawy wizerunku gminy jest zachowany w niej zabytek, historyczny układ urbanistyczny lub znacząca atrakcja turystyczna. W Pionkach wartością, dzięki której miasto może się rozwinąć, są uwarunkowania krajobrazowe. Zamiarem autorki było sprawdzenie jak w takiej sytuacji działają instrumenty prawne, które mają wpływ na przestrzeń i krajobraz miasta. Analizę powyższego problemu przeprowadzono w oparciu o materiały źródłowe (m.in.: Lokalny plan rewitalizacji miasta Pionki, Miejscowy plan zagospodarowania przestrzennego, Strategie rozwoju gminy i Program ochrony Środowiska itp.), a także obserwacje bezpośrednie.
The aim of this presentation is to discuss if the documents containing development plans promote and protect Pionki town’s landscape and culture values. Pionki is situated on the edge of dense forest named Puszcza Kozienicka. The area of Puszcza Kozienicka has become the Kozienicki Landscape Park in 1983. It is difficult to overestimate the values and advantages those forests and also the beauty of those landscapes. Pionki has developed since twenties of XX century together with the military industry – The State Factory of Gunpowder. Firstly it was only the settlement near the factory, but its growth was very fast and in 1954 Pionki became the town. In the second half of XX century some housing estates arose in Pionki. Those new buildings disturbed spatial development of town and were in a big contrast to the surroundings. Additionally their architecture is not corresponding with traditional architecture in this region. However there are some monuments of architecture and some interesting complexes of housing estates and post‐industrial buildings in Pionki, which are protected by the law. In nineties of XX century the chemical industry downfall stopped the growth of Pionki. The living conditions of life got worse, unemployment increased significantly and prosperity of town was over. The municipal authorities have passed some development plans and programs in which they prepared many project which aim to improve the situation of the town using its culture and natural resources.
Źródło:
Prace Komisji Krajobrazu Kulturowego; 2008, 10; 17-26
1896-1460
2391-5293
Pojawia się w:
Prace Komisji Krajobrazu Kulturowego
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Comparative analyses of residential building efficiency for AC and DC distribution networks
Autorzy:
Ahmad, Faraz
Dastgeer, Faizan
Gelani, Hasan E.
Khan, Sidra
Nasir, Mashood
Powiązania:
https://bibliotekanauki.pl/articles/2173601.pdf
Data publikacji:
2021
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
DC distribution system
efficiency analysis
AC vs DC
residential buildings
solar PV
system dystrybucji prądu stałego
analiza wydajności
prąd zmienny
prąd stały
AC/DC
budynki mieszkalne
fotowoltaika
Opis:
The escalating prevalence of rooftop solar PVs and DC powered home appliances are the driving forces for the research in the field of DC distribution at residential level. The current research work presents comparative analyses of AC and DC distribution systems considering various scenarios for the specific purpose of efficiency/energy savings. A modern Bakersfield CA, USA home is considered for the analyses. The loads are classified according to the power demand. Rooftop solar PVs are also included in each residential building. Mathematical equations are devised for the efficiency analysis of residential buildings powered with AC as well as DC. The results reveal strong dependence of the efficiency values on the utilization/types of loads, efficiencies of the power electronic converters (PECs), solar capacity and seasonal conditions, as a function of the time of day. It is concluded that AC system presents better efficiency values as compared to the DC counterpart except during the time periods when solar power is available and when the penetration of variable speed drive (VSD) based loads is high.
Źródło:
Bulletin of the Polish Academy of Sciences. Technical Sciences; 2021, 69, 2; art. no. e136732
0239-7528
Pojawia się w:
Bulletin of the Polish Academy of Sciences. Technical Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Comparative analyses of residential building efficiency for AC and DC distribution networks
Autorzy:
Ahmad, Faraz
Dastgeer, Faizan
Gelani, Hasan E.
Khan, Sidra
Nasir, Mashood
Powiązania:
https://bibliotekanauki.pl/articles/2128137.pdf
Data publikacji:
2021
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
DC distribution system
efficiency analysis
AC vs DC
residential buildings
solar PV
system dystrybucji prądu stałego
analiza wydajności
prąd zmienny
prąd stały
AC/DC
budynki mieszkalne
fotowoltaika
Opis:
The escalating prevalence of rooftop solar PVs and DC powered home appliances are the driving forces for the research in the field of DC distribution at residential level. The current research work presents comparative analyses of AC and DC distribution systems considering various scenarios for the specific purpose of efficiency/energy savings. A modern Bakersfield CA, USA home is considered for the analyses. The loads are classified according to the power demand. Rooftop solar PVs are also included in each residential building. Mathematical equations are devised for the efficiency analysis of residential buildings powered with AC as well as DC. The results reveal strong dependence of the efficiency values on the utilization/types of loads, efficiencies of the power electronic converters (PECs), solar capacity and seasonal conditions, as a function of the time of day. It is concluded that AC system presents better efficiency values as compared to the DC counterpart except during the time periods when solar power is available and when the penetration of variable speed drive (VSD) based loads is high.
Źródło:
Bulletin of the Polish Academy of Sciences. Technical Sciences; 2021, 69, 2; e136732, 1--9
0239-7528
Pojawia się w:
Bulletin of the Polish Academy of Sciences. Technical Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Examination of samples public buildings according to energy efficient
Badanie obiektów użyteczności publicznej w aspekcie ich sprawności energetycznej
Autorzy:
Alagöz, Meryem
Sarıcıoğlu, Pelin
Woloszyn, Marek
Powiązania:
https://bibliotekanauki.pl/articles/370006.pdf
Data publikacji:
2019
Wydawca:
Zachodniopomorski Uniwersytet Technologiczny w Szczecinie. Wydawnictwo Uczelniane ZUT w Szczecinie
Tematy:
energy efficiency
ecotect software
building design
public buildings
Opis:
Public utility buildings are formal, structurally and functionally complex entities. In order to demonstrate energy-related defects of building designs developed by students, the conduct of analyses was proposed. The completed designs of public utility buildings were examined with regard to the energy efficiency of the solutions they feature through the application of the following program: Ecotect software was sufficient. Thus, it has been reached that how can be designed public utility buildings according to energy efficiency. Paying more attention to the energy aspect must change the previously designed architectural design of buildings.
Źródło:
Przestrzeń i Forma; 2019, 38; 111-122
1895-3247
2391-7725
Pojawia się w:
Przestrzeń i Forma
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Structural Failure of Buildings: Issues and Challenges
Autorzy:
Almarwae, Mohammed
Powiązania:
https://bibliotekanauki.pl/articles/1182745.pdf
Data publikacji:
2017
Wydawca:
Przedsiębiorstwo Wydawnictw Naukowych Darwin / Scientific Publishing House DARWIN
Tematy:
Buildings
bracing structures
construction materials
earthquake
seismology
structural failure
structures
Opis:
This paper discusses a list of information and issues that causes of structural failure of buildings. Structural failure begins to occur when the material is stressed to its upper strength limit causing to rupture or extreme deformations. The ultimate strength of the material or the system is the limit of the load bearing capacity. On reaching this limit, the construction materials could already been damaged, and their load carrying capacity is suddenly decreased permanently. If the system is properly designed, a local collapse should normally not be a cause of instant or gradual failure of the complete building. The ultimate failure strength of the construction elements should be carefully considered in the design of structures to prevent failure.
Źródło:
World Scientific News; 2017, 66; 97-108
2392-2192
Pojawia się w:
World Scientific News
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Circular economy in buildings
Autorzy:
Andriulaitytė, Ieva
Valentukeviciene, Marina
Powiązania:
https://bibliotekanauki.pl/articles/2065633.pdf
Data publikacji:
2020
Wydawca:
Politechnika Częstochowska
Tematy:
circular economy
buildings
waste
constructions
built environment
gospodarka o obiegu zamkniętym
budynki
marnotrawstwo
konstrukcje
środowisko zbudowane
Opis:
The circular economy is not only a system of waste management. It is a system which includes the products’ design construction, recycling of raw materials and whose aim is that all components and materials bring added value in different technical and biological cycles. The construction sector is currently among the world’s largest producers of waste. It is estimated that about 1.3 billion tons of construction and demolition waste is generated every year and half of it comes from the construction sector. The building industry has a significant impact on many sectors of the economy, on local jobs and quality of life. It requires vast amounts of resources and accounts for about 50% of all extracted material. According to experts, the amount of waste in the construction sector is the same or even higher than the amount of municipal waste. At the same time, the stream of construction waste makes up the biggest part of industrial waste. Currently, more than at any time before, there is a crucial need for new circular solutions, especially in the building sector. Therefore circular economy principles have a huge potential to contribute to reducing waste and to increased reuse of materials in buildings.
Źródło:
Budownictwo o Zoptymalizowanym Potencjale Energetycznym; 2020, 9, 2; 23--29
2299-8535
2544-963X
Pojawia się w:
Budownictwo o Zoptymalizowanym Potencjale Energetycznym
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Plotting the new building project space in the existing development at the designing stage while following the insolation standards
Kształtowanie otoczenia nowych budynków sytuowanych w istniejącej zabudowie w stadium projektowania przy spełnieniu norm dotyczących nasłonecznienia
Autorzy:
Andropova, O.
Powiązania:
https://bibliotekanauki.pl/articles/2065242.pdf
Data publikacji:
2014
Wydawca:
Politechnika Częstochowska
Tematy:
project space
estimated time of insolation
maximum shadow mask
energy efficient buildings
przestrzeń projektowa
szacowany czas nasłonecznienia
maksymalne zacienienie
budynki efektywne energetycznie
Opis:
It is very important to take into consideration the problems connected with insolation while designing energy efficient buildings. The article covers the outline of plotting a project space using the algorithm of estimated elapsed time measurement of insolation in critical premises and critical points in the adjoining areas, where the insolation standards are to be met.
Przy projektowaniu energoefektywnych budynków ważnym zagadnieniem jest uwzględnianie problemu nasłonecznienia. W artykule przedstawiono schemat kształtowania przestrzeni projektowej przy użyciu algorytmu do określenia obliczeniowej długości czasu nasłonecznienia w najbardziej niekorzystnie położonych pomieszczeniach oraz w niekorzystnie usytuowanych punktach na przylegającej do nich powierzchni, w których powinny być zachowane normatywy nasłonecznienia.
Źródło:
Budownictwo o Zoptymalizowanym Potencjale Energetycznym; 2014, 1 (13); 15--21
2299-8535
2544-963X
Pojawia się w:
Budownictwo o Zoptymalizowanym Potencjale Energetycznym
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wpływ wentylacji higrosterowalnej na obniżenie zużycia energii wielorodzinnych budynków mieszkalnych
The Influence of humidity controlled ventilation energy consumption decrease in multi-family residential buldings
Autorzy:
Antoniewicz, B.
Koczyk, H.
Powiązania:
https://bibliotekanauki.pl/articles/362408.pdf
Data publikacji:
2007
Wydawca:
Instytut Fizyki Budowli Katarzyna i Piotr Klemm
Tematy:
fizyka budowli
wentylacja
zużycie energii
budownictwo mieszkalne
thermal buildings
ventilation
energy consumption
apartment building
Opis:
W referacie przedstawiono wyniki analizy zmienności strumienia powietrza wentylacyjnego dla budynku mieszkalnego w oparciu o bilans wilgoci w cyklu tygodniowym. Obliczenia przeprowadzono dla czterech różnych temperatur zewnętrznych: -18°C, -10°C, 0°C, 10°C dla założonego programu użytkowania mieszkań. Otrzymane wyniki porównano z wynikami badań wentylacji higrosterowalnej przeprowadzonych we Francji. Oszacowano oszczędności energii wynikające z wprowadzenia wentylacji higrosterowalnej w budynku miesz- kalnym.
The paper presents the analysis results of changes in ventilation airflow for a residential building. The analysis is based on humidity balance in a weekly cycle. The calculation has been made for four different outdoor temperatures: -18°C, -10°C, 0°C, 10°C for an assumed apartments occupation scheme. The obtained results have been compared to the results of humidity controlled ventilation research done in France. The energy savings due to application of humidity-controlled ventilation in the building have been estimated.
Źródło:
Fizyka Budowli w Teorii i Praktyce; 2007, T. 2; 7-10
1734-4891
Pojawia się w:
Fizyka Budowli w Teorii i Praktyce
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Edukacja w ośrodku kultury leśnej w Gołuchowie
Education in forest culture centre in Gołuchów
Autorzy:
Antonowicz, A.
Roźmiarek, B.
Powiązania:
https://bibliotekanauki.pl/articles/399622.pdf
Data publikacji:
2008
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
obiekty zabytkowe
arboretum
kultura leśna
historic buildings
forest culture
Opis:
W publikacji przedstawiono działalność edukacyjną Ośrodka Kultury Leśnej w Gołuchowie koncentrującą się na upowszechnianiu wiedzy przyrodniczo-leśnej. Ośrodek funkcjonuje na terenie dziewiętnastowiecznego zespołu zamkowo-parkowego, w skład którego wchodzą: muzeum leśnictwa, park-arboretum oraz pokazowa zagroda zwierząt. Efektem działalności ośrodka jest przywrócenie świetności zarówno obszaru parku, jak i znajdujących się tam zabytkowych obiektów i ich adaptacja do celów muzealnych.
Educational activity of the Forest Culture Centre in Gołuchów were presented in the paper. It is concentrate on diffusion of natural-forest knowledge. The Centre operate on 19th century castle with park area, including forest museum, park-arboretum and representative animal cottage. The effect of the Centre activity is to restoration of splendour of park area and existing monuments as well for museum expositions.
Źródło:
Inżynieria Ekologiczna; 2008, 20; 34-41
2081-139X
2392-0629
Pojawia się w:
Inżynieria Ekologiczna
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies