Tytuł:
Determination of dosimetry parameters of ADVANTAGETM 103Pd brachytherapy seed using MCNP4C computer code
Autorzy:
Ataeinia, V.
Raisali, G.
Sadeghi, M.
Powiązania:
https://bibliotekanauki.pl/articles/148136.pdf
Data publikacji:
2009
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
brachytherapy
103Pd source
dosimetry parameters
MCNP4C
ADVANTAGE TM 103Pd
Opis:
The IsoAid LLC Inc. has been introduced ADVANTAGETM 103Pd brachytherapy seed in 2006. The aim of this work is to determine the dosimetric characteristics of this seed according to AAPM’s recommendation in TG43-U1 using MCNP4C computer code. The dose rate constant has been determined to be 0.694š0.001 cGy.h–1.U–1. The radial dose function has been calculated at distances from 0.25 to 7 cm. Two-dimensional anisotropy function have been calculated at distances from 0.25 to 7 cm and at angles from 0 to 90 degrees centigrade at 10 degrees centigrade increments. The one-dimensional anisotropy function and anisotropy constant have been also calculated. The anisotropy constant in water has been calculated as 0.872š0.001. The results of this investigation are compared with the results of Meigooni et al. obtained by PTRAN code in 2006 and Sowards results obtained by PTRAN code in 2007. The comparison of the dose rate constant and the one-dimensional anisotropy function obtained from the two codes shows good agreement; also the radial dose function at distances lower than 3 cm and the two-dimensional anisotropy function at angles greater than 20 degrees centigrade are in good agreement. But, for the calculated radial dose function at distances beyond 3 cm, we observed differences between our values and Meigooni et al. and Sowards results. Also, differences between the calculated two-dimensional anisotropy function using the two codes for angles smaller than 20 degrees centigrade are considerable. The differences between the results of MCNP4C and PTRAN codes could be related to the different cross-section data libraries used in these two codes.
Źródło:
Nukleonika; 2009, 54, 3; 181-187
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-1 z 1

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies