Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "AC" wg kryterium: Temat


Tytuł:
AC power regulation techniques for renewable energy sources
Techniki regulacji mocy odbiorników AC dla odnawialnych źródeł energii
Autorzy:
Ostrowski, Mariusz
Powiązania:
https://bibliotekanauki.pl/articles/28875039.pdf
Data publikacji:
2023
Wydawca:
Politechnika Lubelska. Wydawnictwo Politechniki Lubelskiej
Tematy:
ac power regulators
pulse width modulation converters
renewable energy systems
regulatory mocy prądu przemiennego
przetwornice modulacji szerokości impulsu
systemy energii odnawialnej
Opis:
This article explores different AC power regulation techniques that can be employed to optimize the output of renewable energy sources, suchas solar and wind power systems. The article provides an overview of the challenges associated with regulating AC power output from renewable sources and examines various techniques that can be used to improve the performance of power regulation systems. These techniques include voltage control, phase control, reactive power compensation, and power factor correction. The article also discusses the benefits and limitations of each technique, as well as their potential applications in renewable energy systems. Overall, this article provides valuable insights for engineers and researchers workingto optimize power auto consumption in renewable energy systems.
W tym artykule omówiono różne techniki regulacji mocy prądu zmiennego, które można wykorzystać do optymalizacji produkcji energiize źródeł odnawialnych, takich jak systemy energii słonecznej i wiatrowej. Artykuł zawiera przegląd wyzwań związanych z regulacją mocy wyjściowej prądu przemiennego ze źródeł odnawialnych i analizuje różne techniki, które można wykorzystać do poprawy wydajności systemów odnawialnych źródeł energii. Techniki te obejmują sterowanie napięciem, sterowanie fazą, kompensację mocy biernej i korekcję współczynnika mocy. W artykule omówiono również zalety i ograniczenia poszczególnych technik, a także ich potencjalne zastosowania w systemach energii odnawialnej. Artykuł zawiera cenne informacje dla inżynierów i badaczy pracujących nad optymalizacją auto konsumpcji energii elektrycznej w systemach energii odnawialnej.
Źródło:
Informatyka, Automatyka, Pomiary w Gospodarce i Ochronie Środowiska; 2023, 13, 4; 103--108
2083-0157
2391-6761
Pojawia się w:
Informatyka, Automatyka, Pomiary w Gospodarce i Ochronie Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Considerations for starting combustion engines with AC machines
Autorzy:
Monroy, Mauricio
Romero, Carlos A.
Henao, Edison
Powiązania:
https://bibliotekanauki.pl/articles/2174476.pdf
Data publikacji:
2023
Wydawca:
Polska Akademia Nauk. Polskie Towarzystwo Diagnostyki Technicznej PAN
Tematy:
internal combustion engine
starter motor
AC machine
torque requirements
ISG
supercapacitor
silnik spalinowy
rozrusznik
maszyna prądu przemiennego
superkondensator
Opis:
To initiate its combustion cycles, internal combustion engines require a minimum rotational speed that can be given from several sources (muscular, electrical, pneumatic, among others). Advantages of initiating an ICE with an AC electrical machine is that it can integrate starter motor and generator in one device, provide a linear ramp of acceleration when starting, and assist the ICE in torque production. This article illustrates considerations for the design of a starting system with an AC electrical machine. Initially, criteria of torque, rotational speed and power requirements are analysed, considering resistances of compression, friction, and inertia of the slider-crank mechanism, as well as accessories, with a preliminary experimental validation. Also, types of three-phase AC electrical machines are put to comparison, as well as their associated electronic components needed for driving them in each case, concluding that AC induction machines require a complex 4-quadrant inverter. PM synchronous machines require a simpler inverter, but with highly specified power electronics components. The classical wound rotor machine requires the simplest inverter, with unidirectional power flow, less power transfer losses and less critical power electronics components. Finally, considerations for using of a battery assisted with supercapacitor as complementary DC power source are made.
Źródło:
Diagnostyka; 2023, 24, 1; art. no. 2023102
1641-6414
2449-5220
Pojawia się w:
Diagnostyka
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Novel passive methods of periodical insulation resistance determination in AC/DC IT systems
Nowe metody pasywne okresowego wyznaczania rezystancji izolacji w układach AC/DC IT
Autorzy:
Olszowiec, Piotr
Powiązania:
https://bibliotekanauki.pl/articles/27309778.pdf
Data publikacji:
2023
Wydawca:
Uniwersytet Technologiczno-Humanistyczny im. Kazimierza Pułaskiego w Radomiu
Tematy:
AC/DC IT systems
insulation
passive method
periodical measurement
układy AC/DC IT
izolacja
metoda pasywna
pomiar okresowy
Opis:
In the publication there is presented current status of development of passive methods of periodical insulation resistance determination in AC/DC IT systems. Their importance is strengthened by the fact that these procedures can be executed both manually by operator and by microprocessor monitors. Two novel methods offer a new approach which might be used also in other measuring applications. For better understanding of the proposed solutions there is given mathematical description of presence of DC components in voltages at both sides of rectifier. For the existing method of “Three Readings of a Voltmeter” and for new alternative techniques there is given an evaluation of their accuracy of insulation resistance determination.
W artykule przedstawiono aktualny stan rozwoju pasywnych metod okresowego wyznaczania rezystancji izolacji doziemnej w układach AC/DC IT. Podano dwa nowe sposoby realizacji tego zadania. Dla pełnego zrozumienia nowych rozwiązań pokazano matematyczne uzasadnienie zależności określających składowe DC w napięciach doziemnych obu stron prostownika diodowego. Dla istniejącej metody oraz jednej z proponowanych procedur oszacowano maksymalne możliwe błędy analitycznego wyznaczania wartości zastępczej rezystancji izolacji całego układu AC/DC IT.
Źródło:
Journal of Automation, Electronics and Electrical Engineering; 2023, 5, 1; 35--44
2658-2058
2719-2954
Pojawia się w:
Journal of Automation, Electronics and Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
On-potential – a new perspective?
Potencjał załączeniowy – nowa odsłona?
Autorzy:
Fiedorowicz, Marek
Powiązania:
https://bibliotekanauki.pl/articles/41159505.pdf
Data publikacji:
2023
Wydawca:
Wydawnictwo SIGMA-NOT
Tematy:
cathodic protection
potential
pipeline
stray currents
AC interference
ochrona katodowa
potencjał
rurociąg
prądy błądzące
oddziaływania AC
Opis:
The article reviews the definition of potential. It discusses specific features of the “on-potential” and its importance in practice and in the assessment of cathodic protection effectiveness, of the corrosion hazards caused by the effects of stray DC currents on cathodically protected pipelines, and of the interference of AC currents with such pipelines.
W artykule dokonano przeglądu definicji potencjału, omówiono specyficzne cechy potencjału załączeniowego oraz jego znaczenie w praktyce i ocenach skuteczności ochrony katodowej, w ocenach zagrożeń korozyjnych powodowanych przez oddziaływania prądów błądzących DC na rurociągi chronione katodowo oraz w ocenach oddziaływań prądów AC na takie rurociągi.
Źródło:
Ochrona przed Korozją; 2023, 8; 218-136
0473-7733
2449-9501
Pojawia się w:
Ochrona przed Korozją
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Synchrophasors-based transmission line protection in the presence of STATCOM
Autorzy:
Ghorbani, Amir
Powiązania:
https://bibliotekanauki.pl/articles/41184010.pdf
Data publikacji:
2023
Wydawca:
Politechnika Warszawska, Instytut Techniki Cieplnej
Tematy:
flexible AC transmission system (FACTS)
controllers
ground distance relay
phasor measurement unit
static synchronous compensator
smart grid
elastyczny system transmisji prądu przemiennego
kontrolery
przekaźnik odległości naziemnej
jednostka miary fazora
statyczny kompensator synchroniczny
inteligentna sieć
Opis:
The distance relay using the transmission line impedance measurement identifies the type and location of the fault. However, any other factors that cause the failure of the measured impedance, makes the relay detect the fault in incorrect location or do not detect the fault at all. One of these factors is the fault resistance which directly increases the measured impedance by the relay. Another factor that indirectly alters the impedance of the transmission line is static synchronous compensator (STATCOM). When a fault happens, current injection by the STATCOM changes the measured signals by the relay and thus makes the calculated impedance incorrect. In this paper, a method is provided based on the combination of distance and differential protection. Firstly, from the current data of buses, faulted transmission line is detected. Then using the presented algorithm, the fault location is calculated on the transmission line. The basis of the algorithm is on the active power calculation of the buses. Fault resistance is calculated from the active powers and its effect will be deducted from calculated impedance by the algorithm. Furthermore, with choosing data of appropriate bus, STATCOM effect is eliminated, and fault location will be obtained.
Źródło:
Journal of Power Technologies; 2023, 103, 1; 58-71
1425-1353
Pojawia się w:
Journal of Power Technologies
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Attenuation of Humming-Type Noise and Vibration in Vehicle HVAC System Using a Tuneable Dynamic Vibration Absorber
Autorzy:
Aziz, Muhammad Safwan Abdul
Mazlan, Ahmad Zhafran Ahmad
Satar, Mohd Hafiz Abdul
Paiman, Muhammad Abdul Rahman
Ghapar, Mohd Zukhairi Abd
Powiązania:
https://bibliotekanauki.pl/articles/31339994.pdf
Data publikacji:
2022
Wydawca:
Polska Akademia Nauk. Czasopisma i Monografie PAN
Tematy:
HVAC
humming noise
vibration attenuation
AC pipe
TDVA
Opis:
Heating, ventilation, air conditioning (HVAC) is one of crucial system in a vehicle. Unfortunately, its performance can be affected by the vibration of HVAC components, which subsequently produced unwanted noises. This paper presents an innovative design solution which called as tuneable dynamic vibration absorber (TDVA) to reduce the humming-type noise and vibration in the HVAC system. A detail investigation is carried by developing a lab-scale HVAC model that has the capability to imitate the real HVAC operation in a vehicle. An alternated air-condition (AC) with a fixed blower speed is implied in the study. The analysis of humming-type noise and vibration induced from the HVAC components are performed, and the TDVA is designed and tuned according to the natural frequency of the AC pipe before the attachment. The humming-type noise and vibration characteristics of the HVAC components are compared before and after the implementation of the TDVA. The findings shown that the HVAC model data compares well with the vehicle data, whereby the implementation of TDVA is found to reduce the vibration of the AC pipe by 79% and 61% in both idle and operating conditions and this subsequently improved the humming-type noise of the HVAC system. It also been observed that the TDVA has an effective frequency range around 75–255 Hz and 100–500 Hz for the HVAC model and vehicle systems, respectively.
Źródło:
Archives of Acoustics; 2022, 47, 3; 331-342
0137-5075
Pojawia się w:
Archives of Acoustics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Design, development and verification of a new multilevel inverter for reduced power switches
Autorzy:
Mahato, Bidyut
Ranjan, Mrinal
Pal, Pradipta Kumar
Gupta, Santosh Kumar
Mahto, Kailash Mahto
Powiązania:
https://bibliotekanauki.pl/articles/2172807.pdf
Data publikacji:
2022
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
7-level/13-level inverter
DC-AC converters
power-electronic switches
sinusoidal PWM
Opis:
Due to recent developments in the field of high-power and medium-voltage, the multilevel inverter has raised to such an extent owing to some of its amazing facts regarding harmonic spectrum, ease in control, reduced electromagnetic interference (EMI), filterless circuit, stress on power switches, common-mode voltage. This paper well describes a novel architecture of a single-phase multilevel inverter using a lesser number of overall components, especially the power switches. The proposed topology is generalized in the structure that can generate any number of voltage steps. A 7-level structure of the proposed topology is explained and is elaborately discussed. Simulation is carried out in MATLAB and corresponding experimental results verify the existence of the proposed multilevel inverter. The real-time experimental results were presented and are well verified by the simulation results for 7-level as well for 13-level across RL-Load. The nature of load current is also indicated as per the nature of load voltage. Nevertheless, the topology is further compared with some of the recent literature and found superior in each respect.
Źródło:
Archives of Electrical Engineering; 2022, 71, 4; 1051--1063
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Electromagnetic analysis, efficiency map and thermal analysis of an 80-kW IPM motor with distributed and concentrated winding for electric vehicle applications
Autorzy:
Młot, Adrian
Korkosz, Mariusz
Lechowicz, Andrzej
Podhajecki, Jerzy
Rawicki, Stanisław
Powiązania:
https://bibliotekanauki.pl/articles/2172808.pdf
Data publikacji:
2022
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
AC losses
concentrated winding
distributed winding
motor performance
radial flux permanent magnet motor
slot fill factor
thermal analysis
Opis:
This paper presents a comparison of an AC radial flux interior permanent magnet (IPM) motor with the distributed winding (DW) and concentrated winding (CW). From time to time, manufacturers of electric vehicles change the design of electric motors, such changes may include changing the DW into CW and vice versa. A change to the winding in a radial permanent magnet synchronous motor may lead to a change in motor parameters during motor operation and /or change in the distribution of the magnetic field and thermal circuit of the electrical machine. The electromagnetic analysis, efficiency map, mechanical stress, and thermal analysis of the machine with the DW and CW are presented in this paper. This article describes the advantages and disadvantages of selected stator winding designs and helps understand manufacturers’ designers how the DW and CW play a key role in achieving the designed motor’s operational parameters such as continuous performance. Analyzing the performance of both machines will help identify their advantages and disadvantages with regard to thermal phenomena, magnetic field and operational parameters of the presented IPM prototypes. Both prototypes are based on commonly used topologies such as 12/8 (slot/pole) and 30/8 (slot/pole) IPM motors consisting of magnets arranged in a V-shape. The AC IPM motor was designed for an 80 kW propulsion system to achieve 170 N·m at a base speed of 4 500 rpm. Modern CAD tools are utilized throughout the numerical computations based on 2-D finite element methods. Selected test data are used to verify and validate the accuracy of finite element models.
Źródło:
Archives of Electrical Engineering; 2022, 71, 4; 981--1002
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Method to determine solar-blind ultraviolet energy and electrical corona loss relation
Autorzy:
Coetzer, Casper J.
Myburgh, Hermanus C.
West, Nicolas
Walker, Jerry
Powiązania:
https://bibliotekanauki.pl/articles/2174850.pdf
Data publikacji:
2022
Wydawca:
Polska Akademia Nauk. Stowarzyszenie Elektryków Polskich
Tematy:
AC voltage
algorithm corona cameras
electrical discharges
optical energy
radiometric measurements
Opis:
Solar-blind ultraviolet cameras as part of high-voltage electrical inspections until recently have mostly been used for pure observations. These observations only imply the presence of corona discharges and not the severity thereof. A radiometric algorithm together with a calibration algorithm to perform an optical energy measurement were presented earlier. This is a guide on how to apply the algorithm to determine the total optical measurement from corona discharges, plus additional processing. This guide and additions are used to compare the electrical and optical domains with actual examples. The main objective is to illustrate how to determine the electrical and optical relation for the IEC 60720 high-voltage electrical test configurations using a standard open procedure.
Źródło:
Opto-Electronics Review; 2022, 30, 4; art. no. e143433
1230-3402
Pojawia się w:
Opto-Electronics Review
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Precision Calculations of the Characteristic Impedance of Complex Coaxial Waveguides Used in Wideband Thermal Converters of AC Voltage and Current
Autorzy:
Kubiczek, Krzysztof
Kampik, Marian
Powiązania:
https://bibliotekanauki.pl/articles/2124756.pdf
Data publikacji:
2022
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
AC voltage standard
current shunt
characteristic impedance
multilayer cylindrical conductor
FEM simulation
modified Bessel functions
numerical stability
calorimetric thermal voltage converter
ac-dc transfer difference
Opis:
The article presents precision and numerically stable method of calculation of the characteristic impedance of cylindrical multilayer waveguides used in high-precision wideband measuring instruments and standards, especially calculable thermal converters of AC voltage and precision wideband current shunts. Most of currently existing algorithms of characteristic impedance calculation of such waveguides are based upon approximations. Unfortunately, application of such methods is limited to waveguides composed of a specific, usually low number of layers. The accuracy of approximation methods as well as the number of layers is sometimes not sufficient, especially when the coaxial waveguide is a part of precision measurement equipment. The article presents the numerically stable matrix analytical formula using exponentially scaled modified Bessel functions to compute characteristic impedance and its components of the cylindrical coaxial multilayer waveguides. Results obtained with the developed method were compared with results of simulations made using the Finite Element Method (FEM) software simulations. Very good agreement between results of those two methods were achieved.
Źródło:
International Journal of Electronics and Telecommunications; 2022, 68, 3; 527--533
2300-1933
Pojawia się w:
International Journal of Electronics and Telecommunications
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Radiometric calibration and measurement algorithm for electrical inspection solar-blind ultraviolet cameras
Autorzy:
Coetzer, Casper J.
West, Nicholas
Powiązania:
https://bibliotekanauki.pl/articles/2063901.pdf
Data publikacji:
2022
Wydawca:
Polska Akademia Nauk. Stowarzyszenie Elektryków Polskich
Tematy:
AC voltage
calibration
corona cameras
electrical discarges
radiometric measurements
Opis:
Solar-blind ultraviolet cameras with image intensifier with CMOS detector typically use various count methodologies to measure the optical energy of an electrical corona. However, these count methodologies are non-radiometric without considering parameters such as distance, focus-, zoom-, and gain setting of a camera. An algorithm which considers the calibration and radiometric measurement of optical energy for the slow frame rate intensifier type cameras is presented. Furthermore, it is shown how these calibration data together with the flowcharts are used for the conversion from raw measured data to radiometric energy values.
Źródło:
Opto-Electronics Review; 2022, 30, 1; 1--9
1230-3402
Pojawia się w:
Opto-Electronics Review
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
System efficiency for AC vs. DC distribution paradigms: a comparative evaluation
Autorzy:
Gelani, Hasan Erteza
Khan, Sidra
Dastgeer, Faizan
Idrees, Zeba
Afzal, Muhammad Waqas
Nasir, Mashood
Powiązania:
https://bibliotekanauki.pl/articles/2173534.pdf
Data publikacji:
2022
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
AC vs DC
DC distribution
efficiency analysis
residential loads
AC/DC
dystrybucja prądu stałego
analiza wydajności
obciążenie mieszkalne
Opis:
The birth of electricity witnessed “the battle of currents” between AC and DC as a medium of power transfer. AC won the battle in the first place because of its ability to transform voltage levels. However, with the development of power electronic converters (PECs), DC is striking back. Most of the electronic loads in our conventional AC-based homes are DC by nature. Moreover, the modern concept of energy-efficient variable speed drive (VSD) based loads, i.e. DC-inverter based air-conditioners and refrigerators, require a DC link for their operation. The driving component of all such loads is the PEC. The operational efficiency of PECs depends on the loading which varies throughout the day. This paper presents a mathematical model based on a bottom-up approach to the comparative efficiency analysis of AC and DC distribution systems considering daily load variation. Two topologies are presented where AC and DC distribution systems are compared in terms of efficiency. The first topology (T1) defines a separate/independent converter for each load, whereas in the second topology (T2) loads of a particular class are lumped and driven by a single converter. The results present DC distribution better than AC distribution with an efficiency advantage of 2.28% and 1.57% for T1 and T2, respectively.
Źródło:
Bulletin of the Polish Academy of Sciences. Technical Sciences; 2022, 70, 1; e139956, 1--9
0239-7528
Pojawia się w:
Bulletin of the Polish Academy of Sciences. Technical Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
A novel source side power quality improved soft starting of three-phase induction motor using a symmetrical angle controller through pic microcontroller
Autorzy:
Selvaperumal, S.
Krishnamoorthy, N.
Prabhakar, G.
Powiązania:
https://bibliotekanauki.pl/articles/2086849.pdf
Data publikacji:
2021
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
soft starting of three phase induction motor
symmetrical angle controller
AC voltage controller
power quality improvement
rozruch trójfazowego silnika indukcyjnego
symetryczny kontroler kąta
kontroler napięcia prądu przemiennego
poprawa jakości energii elektrycznej
Opis:
PIC microcontroller has a vital role in various types of controllers and nowadays the presence of PIC microcontroller is unavoidable in most control applications. This paper describes the enhancement of soft starting of induction motors using PIC microcontroller. Soft starting is required for the induction motors with reduced applied voltages so that the peak starting current is reduced and the startup of the motor is smooth with controlled torque and reduced mechanical vibrations, reduced starting current with correspondingly reduced bus voltage drops. While many of the available schemes of soft starting offer better results in view of smooth starting process, the proposed methodology offers soft starting as well as it cares about the source current quality. In contrast to the conventional multistep starting scheme, in this work a continuously controlled starting scheme is proposed. The three phase AC voltage controller topology is used as the core controller. In each of the half cycles, instead of a single conduction period with a single delay angle, the proposed AC voltage controller is switched symmetrically in each half cycle with multiple pulses in each quarter cycle. Symmetrically placed fixed numbers of switching pulses are used. The paper also describes the various time ratio controls namely the phase angle controller, the extinction angle controller and the symmetrical angle controller. The design aspects of the proposed soft starting scheme and the validation of the proposed system in the MATLAB SIMULINK environment are presented in this paper.
Źródło:
Bulletin of the Polish Academy of Sciences. Technical Sciences; 2021, 69, 2; e136746, 1--12
0239-7528
Pojawia się w:
Bulletin of the Polish Academy of Sciences. Technical Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
A novel source side power quality improved soft starting of three-phase induction motor using a symmetrical angle controller through pic microcontroller
Autorzy:
Selvaperumal, S.
Krishnamoorthy, N.
Prabhakar, G.
Powiązania:
https://bibliotekanauki.pl/articles/2128138.pdf
Data publikacji:
2021
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
soft starting of three phase induction motor
symmetrical angle controller
AC voltage controller
power quality improvement
rozruch trójfazowego silnika indukcyjnego
kontroler kąta symetryczny
kontroler napięcia prądu przemiennego
poprawa jakości energii elektrycznej
Opis:
PIC microcontroller has a vital role in various types of controllers and nowadays the presence of PIC microcontroller is unavoidable in most control applications. This paper describes the enhancement of soft starting of induction motors using PIC microcontroller. Soft starting is required for the induction motors with reduced applied voltages so that the peak starting current is reduced and the startup of the motor is smooth with controlled torque and reduced mechanical vibrations, reduced starting current with correspondingly reduced bus voltage drops. While many of the available schemes of soft starting offer better results in view of smooth starting process, the proposed methodology offers soft starting as well as it cares about the source current quality. In contrast to the conventional multistep starting scheme, in this work a continuously controlled starting scheme is proposed. The three phase AC voltage controller topology is used as the core controller. In each of the half cycles, instead of a single conduction period with a single delay angle, the proposed AC voltage controller is switched symmetrically in each half cycle with multiple pulses in each quarter cycle. Symmetrically placed fixed numbers of switching pulses are used. The paper also describes the various time ratio controls namely the phase angle controller, the extinction angle controller and the symmetrical angle controller. The design aspects of the proposed soft starting scheme and the validation of the proposed system in the MATLAB SIMULINK environment are presented in this paper.
Źródło:
Bulletin of the Polish Academy of Sciences. Technical Sciences; 2021, 69, 2; e136746, 1--12
0239-7528
Pojawia się w:
Bulletin of the Polish Academy of Sciences. Technical Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Comparative analyses of residential building efficiency for AC and DC distribution networks
Autorzy:
Ahmad, Faraz
Dastgeer, Faizan
Gelani, Hasan E.
Khan, Sidra
Nasir, Mashood
Powiązania:
https://bibliotekanauki.pl/articles/2173601.pdf
Data publikacji:
2021
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
DC distribution system
efficiency analysis
AC vs DC
residential buildings
solar PV
system dystrybucji prądu stałego
analiza wydajności
prąd zmienny
prąd stały
AC/DC
budynki mieszkalne
fotowoltaika
Opis:
The escalating prevalence of rooftop solar PVs and DC powered home appliances are the driving forces for the research in the field of DC distribution at residential level. The current research work presents comparative analyses of AC and DC distribution systems considering various scenarios for the specific purpose of efficiency/energy savings. A modern Bakersfield CA, USA home is considered for the analyses. The loads are classified according to the power demand. Rooftop solar PVs are also included in each residential building. Mathematical equations are devised for the efficiency analysis of residential buildings powered with AC as well as DC. The results reveal strong dependence of the efficiency values on the utilization/types of loads, efficiencies of the power electronic converters (PECs), solar capacity and seasonal conditions, as a function of the time of day. It is concluded that AC system presents better efficiency values as compared to the DC counterpart except during the time periods when solar power is available and when the penetration of variable speed drive (VSD) based loads is high.
Źródło:
Bulletin of the Polish Academy of Sciences. Technical Sciences; 2021, 69, 2; art. no. e136732
0239-7528
Pojawia się w:
Bulletin of the Polish Academy of Sciences. Technical Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies