Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "85.70.Ay" wg kryterium: Temat


Wyświetlanie 1-10 z 10
Tytuł:
Active LR Integrator Circuit with Ferrite Core
Autorzy:
Gazda, P.
Nowicki, M.
Kachniarz, M.
Powiązania:
https://bibliotekanauki.pl/articles/1030877.pdf
Data publikacji:
2018-04
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Tematy:
41.20.Gz
85.70.Ay
85.70.Ge
Opis:
The paper presents the idea of active LR integrator circuit based on ferrite core. The LR topology, in contrast to contemporary RC, allow for drift-free operation of the integrator. Presented circuit is intended as main component of continuous operation fluxmeters and magnetoelastic transducers, especially working with low frequency signals. Critical component for proper frequency range and low signal distortion is the core material, which should allow for close-to-ideal inductance in the circuit. Presented simulation, measurement results, and total harmonic distortion analysis show that the proposed circuit works correctly.
Źródło:
Acta Physica Polonica A; 2018, 133, 4; 1041-1044
0587-4246
1898-794X
Pojawia się w:
Acta Physica Polonica A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Study of Magnetic Micro-Ellipses by Cantilever Sensor
Autorzy:
Sečianska, K.
Šoltýs, J.
Cambel, V.
Powiązania:
https://bibliotekanauki.pl/articles/1032826.pdf
Data publikacji:
2017-04
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Tematy:
85.70.Ay
85.85.+j
81.16.Nd
Opis:
In this paper, we propose a method for prototyping cantilever sensors by means of a modification of commercial atomic force microscopy cantilevers, using electron beam lithography and focused ion beam milling. To overcome obstacles with resist coating related to spin-coating of nonplanar 3D substrates, in this case of free-standing cantilevers, we propose a modified method based on spin-coating technique. An auxiliary atomic force microscopy chip was inserted below the cantilever to quasi-planarize the surface during spin-coating of electron beam resist. Magnetic micro-ellipses were prepared at the free-end of the cantilever by electron beam lithography. We propose a design of a cantilever sensor for the study of magnetic coupling between two cantilevers, prepared by focused ion beam milling. In ideal case, the coupling could be detected by a shift in resonance peaks. Attractive and repulsive forces between magnetic structures were shown by magnetic force microscopy.
Źródło:
Acta Physica Polonica A; 2017, 131, 4; 833-835
0587-4246
1898-794X
Pojawia się w:
Acta Physica Polonica A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Effect of the Fixation Patterns on Magnetic Characteristics of Amorphous Glass-Coated Sensoric Microwires
Autorzy:
Hudak, R.
Varga, R.
Hudak, J.
Praslicka, D.
Blazek, J.
Polacek, I.
Klein, P.
Powiązania:
https://bibliotekanauki.pl/articles/1202355.pdf
Data publikacji:
2014-07
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Tematy:
87.85.G-
87.85.fk
85.70.Ay
Opis:
Some of the frequent reasons of titanium implant failures in human body are incorrect biomechanical interactions within the tissue-implant interface and inflammatory processes arising around the implant's application area. For both processes, it is crucial to locate them and intervene in time. One of the monitoring possibilities of the mentioned processes is the application of amorphous glass-coated sensoric microwires (AGCSM). Magnetic characteristics of these microwires are influenced by both mechanical tension (magnetoelastic interaction of the magnetic moment with mechanical stress) and by temperature (different coefficient of thermal expansion of the metal core and glass coating). The key task, in order to change the magnetic characteristics of AGCSM from both clinical and scanning point of view, appears to be the fixation pattern of AGCSM in the implant's body. The presented study shows the impact of four types of AGCSM fixation patterns (at one ending, at both endings, in the middle and along the entire length) on the thermal response process tested in laboratory conditions. The obtained results will enable to establish the AGCSM fixation methodology in the implant's body in order to achieve optimal output temperature parameters form the implant and the tissue-implant interface by magnetic contactless measurements.
Źródło:
Acta Physica Polonica A; 2014, 126, 1; 417-418
0587-4246
1898-794X
Pojawia się w:
Acta Physica Polonica A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Thin Film Manganite-Metal Interconnection and "Loop Effect" Studies in CMR-Based High Magnetic Field Sensors
Autorzy:
Balevičius, S.
Stankevič, V.
Žurauskienė, N.
Šimkevičius, Č.
Liebfried, O.
Löffler, M.
Schneider, M.
Abrutis, A.
Plaušinaitienė, V.
Powiązania:
https://bibliotekanauki.pl/articles/1807946.pdf
Data publikacji:
2009-06
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Tematy:
75.47.Gk
75.47.Lx
85.70.Ay
Opis:
The design, technology and main characteristics of Ag contacts as well as "loop effect" peculiarities of colossal magnetoresistance B-scalar high magnetic field sensor based on $La_{1-x}(Ca)Sr_x$ $MnO_3$ films used for measuring high magnetic field pulses are presented.
Źródło:
Acta Physica Polonica A; 2009, 115, 6; 1133-1135
0587-4246
1898-794X
Pojawia się w:
Acta Physica Polonica A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Geometry Optimization of Pulsed Inductors
Autorzy:
Bartkevičius, S.
Novickij, J.
Višniakov, N.
Powiązania:
https://bibliotekanauki.pl/articles/1807966.pdf
Data publikacji:
2009-06
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Tematy:
07.55.Db
84.32.Hh
85.70.Ay
Opis:
The optimization of pulsed power inductors' geometry is a difficult multi-dimensional task. On the one hand, an inductor could be destroyed because of the Joule overheating, on the other hand, it might be damaged by the Lorentz forces acting in its windings. The magnetic field pulse up to 50 T is the target while fields of this magnitude are the interest in many scientific applications. All factors mentioned are directly dependent on inductor's geometry, i.e. on the number of winding layers and windings per layer. Therefore, a detailed analysis of thermodynamic, electromagnetic and mechanical processes is inevitable and was carried out for different geometrical inductor configurations to reach the goal: a non-destructive inductor that can meet required magnetic field parameters. Direct calculation methods were used to create universal algorithms in MATLAB environment. The zone of inductor geometries, where stresses do not exceed the yield strength of materials, inductor is not overheated and generated magnetic field magnitude is in acceptable range, is given as a result which enables to manufacture new prototypes saving additional costs and time.
Źródło:
Acta Physica Polonica A; 2009, 115, 6; 1155-1157
0587-4246
1898-794X
Pojawia się w:
Acta Physica Polonica A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Minor Loops in the Harrison Model
Autorzy:
Chwastek, K.
Szczygłowski, J.
Wilczyński, W.
Powiązania:
https://bibliotekanauki.pl/articles/1431773.pdf
Data publikacji:
2012-04
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Tematy:
75.60.-d
75.60.Ej
85.70.Ay
Opis:
A novel description of hysteresis phenomenon is presented. The examined description emphasizes the roles of bistability and quantum phenomena as processes responsible for hysteresis loop formation in magnetic materials. Major and symmetric minor hysteresis loops are modelled in chosen soft magnetic materials using the Harrison model. A reasonable agreement between theory and experiment is achieved.
Źródło:
Acta Physica Polonica A; 2012, 121, 4; 941-944
0587-4246
1898-794X
Pojawia się w:
Acta Physica Polonica A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
High Pulsed Magnetic Field Sensor Based on La-Ca-Mn-O Thin Polycrystalline Films
Autorzy:
Balevičius, S.
Žurauskienė, N.
Stankevič, V.
Keršulis, S.
Novickij, J.
Altgilbers, L. L.
Clarke, F.
Powiązania:
https://bibliotekanauki.pl/articles/2041727.pdf
Data publikacji:
2005-01
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Tematy:
75.30.Kz
73.40.Gk
85.70.Ay
61.72.Mm
Opis:
It is demonstrated that polycrystalline La$\text{}_{0.33}$Ca$\text{}_{0.67}$MnO$\text{}_{3}$ thin film sensors can be used to measure pulsed strong magnetic fields with microsecond duration rise and decay times. The response characteristics of these sensors were investigated using 0.7-1.0 ms duration bell-shaped magnetic field pulses of 10-20 T amplitudes and by using special waveform magnetic field pulses with amplitudes of 40 T and decay times of 50μs. The response of these magnetic field sensors was compared with those of conventional loop sensors and Faraday rotation sensors using Bi$\text{}_{12}$SiO$\text{}_{20}$ single crystals as a known standard.
Źródło:
Acta Physica Polonica A; 2005, 107, 1; 207-210
0587-4246
1898-794X
Pojawia się w:
Acta Physica Polonica A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Investigations and Applications of Nanoperm-Type Soft Magnetic Materials
Autorzy:
Hasiak, M.
Łukiewski, M.
Miglierini, M.
Kaleta, J.
Powiązania:
https://bibliotekanauki.pl/articles/1534084.pdf
Data publikacji:
2010-11
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Tematy:
81.05.Kf
81.07.Bc
81.40.Rs
85.70.Ay
Opis:
The microstructure and magnetic properties of $Fe_{82}Zr_4Nb_3B_{10}Cu_1,$ $Fe_{80}Zr_4Mn_3B_{12}Cu_1$ and $Fe_{80}Zr_4Ti_3Cu_1B_{12}$ alloys were investigated. Using RALE software the basic parameters of transformers made from nanocrystalline alloys with about 25% and 50% of crystalline phase were calculated. The transformer made from $Fe_{80}Zr_4Ti_3Cu_1B_{12}$ alloys after annealing at 773 K for 1-shows the lowest core losses and highest efficiency.
Źródło:
Acta Physica Polonica A; 2010, 118, 5; 829-831
0587-4246
1898-794X
Pojawia się w:
Acta Physica Polonica A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Layer and Interface Structure of CoFe/Ru Multilayers
Autorzy:
Pym, A.
Lamperti, A.
Cardoso, S.
Freitas, P.
Tanner, B.
Powiązania:
https://bibliotekanauki.pl/articles/1814028.pdf
Data publikacji:
2007-12
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Tematy:
61.10.Kw
68.65.Ac
68.35.Ct
75.50.Kj
85.75.Dd
85.70.Ay
Opis:
Grazing incidence X-ray scattering measurements have been performed to probe the structure of CoFe/Ru layers and their interfaces. It was found that the interface width increased approximately linearly with the layer number from the substrate in a multilayer and that a substantial asymmetry existed between the width of CoFe/Ru and Ru/CoFe interfaces. By co-minimizing both the specular and diffuse scatter with that simulated from a model structure, the topological roughness amplitude was determined to be comparable to the intermixing interface width.
Źródło:
Acta Physica Polonica A; 2007, 112, 6; 1243-1248
0587-4246
1898-794X
Pojawia się w:
Acta Physica Polonica A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
An Improvement of Magnetic Flux Linkage in Electrical Generator using the novel Permanent Magnet Arrangement
Autorzy:
Sriwannarat, W.
Khunkitti, P.
Janon, A.
Siritaratiwat, A.
Powiązania:
https://bibliotekanauki.pl/articles/1030384.pdf
Data publikacji:
2018-03
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Tematy:
03.50.De
07.55.Db
75.50.Ww
83.60.Np
84.30.Ng
85.70.Ay
Opis:
The partitioned stator permanent magnet generator (PS-PMG) has been extensively used as electrical generator due mainly to their high flux linkage, high electromotive force EMF) and high efficiency, especially the PM arrangement of the PS-PMG is an important factor to improve the performance of the generator. Therefore, we propose the novel permanent magnet PM) arrangement of the PS-PMG by using the dual rotor with coaxial core structure in order to improve the flux linkage and the EMF of PS-PMG. The PM position of stators of the conventional PS-PMG was rearranged, then the electrical characteristic of the proposed structure was characterized through the simulations based on finite element method. It was found that the flux linkage produced by the proposed structure is 37.06% higher than that of the conventional PS-PMG existed in the literatures because the area for induced flux linkage is significantly increased. This flux linkage enhancement further causes an increment of EMF about 34.95% compared to that of the conventional PS-PMG under the same condition. Especially, the EMF produced by the proposed structure is classified in the high-value range regarding the PM generator. Then, the PS-PMG using novel permanent magnet arrangement could be another remarkable choice for the electrical generator application
Źródło:
Acta Physica Polonica A; 2018, 133, 3; 642-644
0587-4246
1898-794X
Pojawia się w:
Acta Physica Polonica A
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-10 z 10

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies