Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "3D motion capture" wg kryterium: Temat


Wyświetlanie 1-9 z 9
Tytuł:
Biomechanical analysis of Yangs spear turning-stab technique in Chinese martial arts
Autorzy:
Liu, Yufeng
Kong, Jianguo
Wang, Xiuping
Shan, Gongbing
Powiązania:
https://bibliotekanauki.pl/articles/1922261.pdf
Data publikacji:
2020-08-05
Wydawca:
PPHU Projack Jacek Wąsik
Tematy:
3D motion capture
force measurement
phases
hiding
sliding
relative motion
Opis:
The Yang's spear turning-stab was a legendary technique, applied in ancient battles in China. It resulted in numerous famous winnings. The mythical aspect of the technique is a victory in fleeing and back-facing a fighter. Now the skill is a spear technique of Chinese martial arts that is learned and excised by many Chinese Gungfu practitioners. Due to a dearth of scientific study on the skill, the uniqueness and its winning secretes are still unknown. The aim of this study is to demystify the skill by using a synchronized measurement of 3D motion capture (VICON 12 camera system), stab-force measurement (AMTI force platform). Six Gungfu athletes with more than 30 years training experience participated in the study. Both the Yang's spear turning-stab (used by a fleer) and spear forward-stab (used by a chaser) were measured and biomechanically analyzed. The results reveal that there would be six secrets for its historical successes. They are 1) showing weakness (i.e. pretend to be defeated), 2) shortening the stab for quick turning, 3) hiding the stab for a covert attack, 4) leaving less reaction time for opponent, 5) generating higher stab-force than opponent, and 6) leaning backward for a stable stab-posture. These secrets identify elements necessary for systematic training toward a reliable execution of the skill. This skill shows the delicate characteristics of Chinese martial culture. Learning and training the skill would benefit trainees both physically and culturally.
Źródło:
Physical Activity Review; 2020, 2, 8; 16-22
2300-5076
Pojawia się w:
Physical Activity Review
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Study on the Influence of Elastic Compression Pants Elasticity and Movement Speed on Human Joint Protection
Autorzy:
Zhang, Ningfeng
Liu, Chengxia
Powiązania:
https://bibliotekanauki.pl/articles/2200750.pdf
Data publikacji:
2022
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Biopolimerów i Włókien Chemicznych
Tematy:
fabric
movement speed
protective performance
knee joint
3D motion capture
Opis:
The aim of this study was to clarify how human movement speed and pants elasticity affect the athletic performance of knee joint protection by testing pants with different elastic properties: CP1 (tight pants) and CP2&CP3 (elastic compression pants), which reinforce the knee joint. In addition, CS (cotton sport pants) was developed as a control garment. Three subjects wore CP1, CP2, CP3 and CS while running on the treadmill at three kinds of human movement speed. A three-dimensional motion capture instrument was used to capture the three-dimensional trajectory of the marked points of lower limbs. As a result, the influence of the movement speed on the kinematic parameters (AKJ & gait cycle) was more obvious than the fabric elasticity. If elastic pants are worn during running, the change of AKJ will be stable with the increase of speed. When non-elastic pants are worn, the effect is opposite. Not only that, elastic compression pants are efficient in reducing the motion amplitude of the knee joint during the suspension period as far as 41°, making it highly practical in terms of stability. That is, the elastic fabric can protect the joints when the lower limbs are in motion. Moreover, with the increase of speed and elasticity, the elastic pants can reduce the gait cycle by up to 22% compared with non-elastic pants alone. Through the kinematics mechanism of human joints, these findings may translate into an effect on protective performance and a reduction in sport injuries. Therefore, it is necessary to wear elastic pants, especially compression pants, when running at higher speed, as the average gait cycle gradually decreases. This research shows that the knee joint protection functions of elastic compression garments differ according to the level of elasticity and differential movement speed, providing theoretical support for designing and producing elastic compression pants. It also acts as a guide for the research of lower limb joint protection.
Źródło:
Fibres & Textiles in Eastern Europe; 2022, 6 (151); 80--90
1230-3666
2300-7354
Pojawia się w:
Fibres & Textiles in Eastern Europe
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Metoda docinania faz ruchu podczas wiosłowania na ergometrze na podstawie danych trójwymiarowych
Method of cutting phases of motion while rowing on the ergometer based on three-dimensional motion
Autorzy:
Kowalczyk, Kacper
Skublewska-Paszkowska, Maria
Powiązania:
https://bibliotekanauki.pl/articles/98188.pdf
Data publikacji:
2017
Wydawca:
Politechnika Lubelska. Instytut Informatyki
Tematy:
motion capture
plik C3D
analiza ruchu 3D
C3D file
3D motion analysis
Opis:
W artykule przedstawione zostały metody modyfikacji danych motion capture w formacie C3D oraz analiza modyfikacji danych przy pomocy autorskiej aplikacji. Aplikacja służy do wczytywania plików w formacie C3D z zarejestrowanym ruchem i automatycznego wycięcia powtarzających się, podobnych sekwencji nagranego ruchu. Analizę przeprowadzono pod kątem porównania ze sobą otrzymanych wyciętych faz ruchu. Pod uwagę brane były długości poszczególnych faz, odległości maksymalne i minimalne pomiędzy badanymi markerami oraz porównywane startowe i końcowe klatki ruchu.
The article presents both the methods of data modification of motion capture data in C3D file format, and the analysis of the modification of motion capture data using implemented application. The application is used to load C3D files with recorded motion and to automatic cut of the repeating, similar sequences of recorded motion. The analysis was conducted in terms of comparing received cut phases of motion. Study include cases such as length of particular phases, maximum and minimum distance between examined markers and comparison of start and final motion frames.
Źródło:
Journal of Computer Sciences Institute; 2017, 5; 155-158
2544-0764
Pojawia się w:
Journal of Computer Sciences Institute
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Metody obróbki danych EMG
The methods of EMG data processing
Autorzy:
Serej, M.
Skublewska-Paszkowska, M.
Powiązania:
https://bibliotekanauki.pl/articles/98066.pdf
Data publikacji:
2017
Wydawca:
Politechnika Lubelska. Instytut Informatyki
Tematy:
EMG
Motion Capture
plik C3D
file C3D
Opis:
W artykule zostały przedstawione metody obróbki danych badania elektromiograficznego (EMG) oraz analiza sygnału EMG przy pomocy zaimplementowanej autorskiej aplikacji. Aplikacja służy do wczytania sygnału EMG zapisanego w pliku o rozszerzeniu .C3D. Analizę przeprowadzono pod względem największej aktywności mięśni podczas wykonywania ćwiczeń rejestrowanych przy pomocy techniki Motion Capture.
The article presents both the methods of data processing of electromyography (EMG), and EMG signal analysis using the implemented piece of software. This application is used to load the EMG signal stored in a file with the .C3D extension. The analysis was conducted in terms of the highest muscles activaton during exercise recorded with Motion Capture technique.
Źródło:
Journal of Computer Sciences Institute; 2017, 3; 38-45
2544-0764
Pojawia się w:
Journal of Computer Sciences Institute
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Rejestracja ruchu za pomocą urządzenia Microsoft Kinect
Motion capture with Microsoft Kinect sensor
Autorzy:
Kopniak, P.
Powiązania:
https://bibliotekanauki.pl/articles/152014.pdf
Data publikacji:
2012
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
rejestracja ruchu
grafika 3D
kontrolery gier
motion capture
3D graphics
game controllers
Opis:
Artykuł dotyczy tematyki rejestracji ruchu postaci ludzkiej (ang. Motion Capture). Praca pokazuje jak do rejestracji ruchu można wykorzystać kontroler ruchu Microsoft Kinect. Praca zawiera wyniki badań weryfikujących jakość oprogramowania NITE służącego do wyznaczania rotacji członków ciała w stawach. Badania wykazały, że jakość rejestrowanego ruchu nie jest wysoka. Mimo tego uzyskane dane mogą być wykorzystane do analizy gestów lub rozpoznawania ruchu.
This paper refers to a subject of a human body motion capture. Common video based motion capture systems are very expensive. This paper shows that it is possible to use a cheaper solution for motion capture which is a Microsoft Kinect movement controller. There is presented the software for motion capture of a human skeleton. We may use Microsoft SDK programmer toolkit or freeware frameworks like CL NUI Platform, OpenKinect and OpenNI for this purpose. We used OpenNI and NITE libraries (diagram in Fig. 2) for our research. The results of measurements of human joint angles with use of Kinect and our OpenNI based application are given and discussed. These angles are used for recording the movement into motion capture BVH files. We used free application Brekel Kinect (Fig. 3) for this purpose. The recorded data can be used for a realistic animation development. In our case, the data was used as an input source for our own visualization application made in Java language. The quality of recorded motion is not very high due to the calculation delays and problems with appropriate joint localization by the NITE software. The Kinect controller is not suitable for very accurate motion capture, e.g. for the needs of biomedicine, but the captured data are of sufficient quality for research related to the analysis of gestures and remote control.
Źródło:
Pomiary Automatyka Kontrola; 2012, R. 58, nr 11, 11; 1016-1018
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Pomiary kątów ugięcia kończyny w stawie z wykorzystaniem inercyjnego systemu Motion Capture
Measurements of bend angles of the limb in a joint with the use of an inertial motion capture system
Autorzy:
Kopniak, P.
Powiązania:
https://bibliotekanauki.pl/articles/152530.pdf
Data publikacji:
2014
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
rejestracja ruchu
grafika 3D
animacja
rehabilitacja
czujnik inercyjny
motion capture
3D graphics
animation
rehabilitation
inertial sensor
Opis:
Artykuł dotyczy zastosowań systemu rejestracji ruchu wykorzystującego inercyjne czujniki MEMS do badań aparatu ruchu człowieka. Badania tego typu umożliwią dokładniejsze diagnozy ortopedyczne oraz weryfikację postępów rehabilitacji. W artykule opisano budowę, właściwości i zasadę działania systemu Xsens Xbus Kit opartego na czujnikach MTx, metody wyznaczania kąta ugięcia kończyny w stawie na podstawie danych otrzymywanych z czujników oraz przykładowe wyniki badań ruchliwości kończyny. W artykule zawarto także badania dokładności pomiaru kątów poprzez czujniki MTx.
This paper concerns applications of a motion capture system based on MEMS inertial sensors to research of the human locomotion system. Such research will enable more accurate diagnosis and verification of progress of orthopedic rehabilitation. The aper describes the construction, properties and the principle of operation of the Xsens Xbus Kit based on MTx sensors (Fig. 1). It depicts the method of determining the angle of bend of the limb in a joint on the basis of data received from the sensors and sample results of the mobility of the limb, too. Each sensor of Xbus Kit system includes an integrated three-axis accelerometer, gyroscope and magnetometer. In addition, inside there is a signal processor that uses several profiles for the Kalman filter (Fig. 2). As a result, the sensors can return raw or processed data of acceleration or the Euler angles describing the orientation of the sensor in 3D space [7]. The research described in the paper deals with the measurement of the angle of band of the elbow. To measure the band of limb in the joint is sufficient to calculate the difference of yaw angles measured by two MTx sensors (Fig. 2). As a result of tests, the maximum error of the sensor measurement was determined. It was 1°. The sensors measured the angles accurately, consistently and done it in real time (Figs. 6 and 7). The performed studies also showed that the measurement deviations of MTx sensors did not depend on the position of the limb with the exception of the vertical orientation in which the X-axis sensor coincided with the direction of gravity. Then there is a mathematical singularity [7].
Źródło:
Pomiary Automatyka Kontrola; 2014, R. 60, nr 8, 8; 590-593
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analysis of two methods indicating the shoulder joint angles using three dimensional data
Autorzy:
Skublewska-Paszkowska, Maria
Dekundy, Michal
Lukasik, Edyta
Smolka, Jakub
Powiązania:
https://bibliotekanauki.pl/articles/1031705.pdf
Data publikacji:
2018
Wydawca:
PPHU Projack Jacek Wąsik
Tematy:
C3D file
Plug-in Gait biomechanical model
angle calculation methods
motion capture
Opis:
The article contains a comparative analysis of two methods of calculating angles in the shoulder joint of the right upper limb. For the purposes of this study, a marker -vector method was developed that calculates angles based on retroreflective 3D marker’s positions and vectors created on the basis of their positions. Movements from two types of sports (sword fighting and tennis forehand) were analysed. These movem ents were recorded using an optical motion capture system. The obtained results were compared with the values read from the Plug -in Gait biomechanical model from C3D files. The results show that the proposed method is more universal and can be used indepen dently. In addition, the Plug -in Gait model is not adequate for the analysis of the acquired shoulder angles of tennis players.
Źródło:
Physical Activity Review; 2018, 6; 37-44
2300-5076
Pojawia się w:
Physical Activity Review
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Badania doświadczalne chodu dzieci zdrowych
Analysis of the healthy childrens gait
Autorzy:
Kania, E.
Głowacka-Kwiecień, A.
Jochymczyk, K.
Jureczko, P.
Powiązania:
https://bibliotekanauki.pl/articles/99342.pdf
Data publikacji:
2008
Wydawca:
Politechnika Śląska. Katedra Biomechatroniki
Tematy:
chód
analiza chodu
pomiar ruchu
biomechanika
dzieci
3D
gait
gait analysis
motion capture
biomechanics
children
Opis:
Niniejszy artykuł zawiera opis zastosowanej metody analizy chodu dzieci zdrowych oraz przykład uzyskanych wyników dla jednego z nich. Celem pracy jest wyznaczenie wzorca chodu dzieci zdrowych, stanowiących grupę porównawczą dla wyników badania chodu dzieci z guzami mózgu. Badania realizowane są w Centrum Zdrowia Dziecka w Katowicach - Ligocie.
The article present the methods which are use to analyze the gait of the children. Moreover, introduce the source of incorrect norm of healthy children gait parameters for different gait laboratory. It gives the base to further investigation as well.
Źródło:
Aktualne Problemy Biomechaniki; 2008, 2; 87-92
1898-763X
Pojawia się w:
Aktualne Problemy Biomechaniki
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Metody trójwymiarowej analizy ruchu człowieka
The methods of three dimensional human motion analysis
Autorzy:
Sacha, E.
Powiązania:
https://bibliotekanauki.pl/articles/99214.pdf
Data publikacji:
2008
Wydawca:
Politechnika Śląska. Katedra Biomechatroniki
Tematy:
biomechanika
analiza chodu
pomiar ruchu
system IDEEA
system Aurora
system Moven
system CMS-HS
rezonans magnetyczny
3D
biomechanics
gait analysis
motion capture
IDEEA system
Aurora system
Moven system
CMS-HS system
magnetic resonance
Opis:
W artykule przedstawione zostały główne techniki pomiarowe, stosowane w trójwymiarowej analizie ruchu człowieka, jako alternatywa dla systemów optoelektronicznych. Artykuł ma charakter poglądowy, przedstawia ogólną charakterystykę i zasadę działania metod badawczych.
This paper is a general demonstration of the newest, non-optical method, used in 3D motion analysis. It contains a few main measuring techniques, like electromagnetic tracking system, accelerometer system, ultrasound method and the other, which are the alternatives for video-based optical method of human motion analysis. There is also a notice about using the Magnetic Resonance Imaging for kinematic analysis in the future.
Źródło:
Aktualne Problemy Biomechaniki; 2008, 2; 141-146
1898-763X
Pojawia się w:
Aktualne Problemy Biomechaniki
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-9 z 9

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies