Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "07.07.Df" wg kryterium: Temat


Tytuł:
Porous Silicon Based Sensor for Organic Vapors
Autorzy:
Kayahan, E.
Bahsi, Z.
Oral, A.
Sezer, M.
Powiązania:
https://bibliotekanauki.pl/articles/1193711.pdf
Data publikacji:
2015-04
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Tematy:
07.07.Df
Opis:
Porous silicon (PS) has been an attractive material for enhancing optical properties of silicon. Its large surface area for sensor applications and compatibility with silicon-based technologies has been a driving force for further technology development. In this study, ability of PS to sense at room temperature organic vapors such as acetone, trichloroethylene and hexane, which are harmful to human health, has been investigated. Electrical (DC) and photo-luminescence (PL) measurements in a controlled atmosphere (nitrogen gas and an organic vapor mix) were performed to test the sensor response towards the organic vapors. It was found that PS surface is very sensitive against these vapors. The experimental results also suggested that PS can be used as a new electro-optical material to sense harmful vapors.
Źródło:
Acta Physica Polonica A; 2015, 127, 4; 1400-1402
0587-4246
1898-794X
Pojawia się w:
Acta Physica Polonica A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Porous Silicon Based Humidity Sensor
Autorzy:
Kayahan, E.
Powiązania:
https://bibliotekanauki.pl/articles/1401435.pdf
Data publikacji:
2015-04
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Tematy:
07.07.Df
Opis:
Porous silicon (PS) is well known as a photovoltaic material. However, in the last couple of years, research has focused on the use of porous silicon as chemical-biological sensors. This paper discusses the use of PS as an optical humidity sensor. Photo-luminescence (PL) quenching measurements in a controlled humidity atmosphere (mixed Nitrogen gas and water vapor) were performed to test the sensor response towards the water vapor. Surface morphologies of the PS samples were characterized by a scanning electron microscopy (SEM) and structural properties were investigated via Fourier Transform Infrared (FTIR) spectroscopy. It was found that PS surface is very sensitive to the water vapor. The experimental results suggested that PS surface is a promising candidate material to be used as a humidity sensor.
Źródło:
Acta Physica Polonica A; 2015, 127, 4; 1397-1399
0587-4246
1898-794X
Pojawia się w:
Acta Physica Polonica A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Methanol Vapor Sensing by Porous Silicon
Autorzy:
Yılmaz, O.
Kayahan, E.
Gören, F.
Dumludağ, F.
Powiązania:
https://bibliotekanauki.pl/articles/1195231.pdf
Data publikacji:
2014-02
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Tematy:
07.07.Df
Opis:
In this study, methanol vapor sensing of porous silicon was investigated. The porous silicon samples were anodized in HF based solution and rinsed with ethanol or deionized water after the anodisation. Porous silicon surface is very sensitive for methanol vapor sensing and the sensitivity affect from the rinsing procedure of porous silicon. The experimental results show that porous silicon is a promising candidate material for sensing methanol vapor.
Źródło:
Acta Physica Polonica A; 2014, 125, 2; 288-289
0587-4246
1898-794X
Pojawia się w:
Acta Physica Polonica A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Water-Sorption Effects near Grain Boundaries in Modified MgO-Al₂O₃ Ceramics Tested with Positron-Positronium Trapping Algorithm
Autorzy:
Klym, H.
Ingram, A.
Shpotyuk, O.
Hadzaman, I.
Chalyy, D.
Powiązania:
https://bibliotekanauki.pl/articles/1030933.pdf
Data publikacji:
2018-04
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Tematy:
81.05.Je
07.07.Df
Opis:
Water-sorption processes near grain boundaries in the MgO-Al₂O₃ ceramics prepared at different temperatures were studied using positron annihilation lifetime spectroscopy. Numerical values of three- and four-component treatment of spectra were used for study of physical- and chemical-sorption processes in the MgO-Al₂O₃ ceramics. To apply mathematical approach in the form of positron-positronium trapping algorithm into three-component treatment of positron annihilation lifetime spectra it was shown that physical-adsorbed water did not modify positron trapping sites near grain boundaries in water-immersed MgO-Al₂O₃ ceramics and localized mainly in nanopores. The chemically-adsorbed water modifies structural extended defects located near grain boundaries that accompanied them by void fragmentation at water desorption.
Źródło:
Acta Physica Polonica A; 2018, 133, 4; 864-868
0587-4246
1898-794X
Pojawia się w:
Acta Physica Polonica A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Temperature Sensitive Spinel-Type Ceramics in Thick-Film Multilayer Performance for Environment Sensors
Autorzy:
Hadzaman, I.
Klym, H.
Shpotuyk, O.
Brunner, M.
Powiązania:
https://bibliotekanauki.pl/articles/1550632.pdf
Data publikacji:
2010-01
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Tematy:
81.05.Je
07.07.Df
Opis:
Temperature sensitive thick films based on spinel-type semiconducting ceramics of different chemical composition $Cu_{0.1}Ni_{0.1}Co_{1.6}Mn_{1.2}O_{4}$ (with $p^{+}$-types of electrical conductivity), $Cu_{0.1}Ni_{0.8}Co_{0.2}Mn_{1.9}O_{4}$ (with p-types of electrical conductivity) and their multilayer $p^{+}$-p structures were fabricated and studied. These thick-film elements possess good electrophysical characteristics before and after long-term ageing test at 170°C. It is shown that degradation processes connected with diffusion of metallic Ag into film grain boundaries occur in one-layer p- and $p^{+}$-conductive thick films. The $p^{+}$-p structures were of high stability, the relative electrical drift was not greater than 1%.
Źródło:
Acta Physica Polonica A; 2010, 117, 1; 234-237
0587-4246
1898-794X
Pojawia się w:
Acta Physica Polonica A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Inverted Rib Waveguides - Theoretical Analysis of Sensing Properties
Autorzy:
Tyszkiewicz, C.
Powiązania:
https://bibliotekanauki.pl/articles/1399407.pdf
Data publikacji:
2013-09
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Tematy:
42.79.Gn
07.07.Df
Opis:
Optical waveguides are fundamental components of chemical and biochemical evanescent wave sensors. Presented work is devoted to theoretical investigations of homogeneous and surface sensitivity characteristics of the inverted rib waveguide structure. The inverted rib waveguide discussed in this paper is composed of an ion-exchange based channel waveguide formed in a glassy substrate and a uniform, high refractive index, sol-gel derived $SiO_2-TiO_2$ film. Characteristics of a homogeneous sensitivity, a surface sensitivity and fundamental modes sensitivity differences in function of a uniform film thickness and a maximal refractive index contrast of the gradient index channel waveguide are given. The influence of the $SiO_2-TiO_2$ film thickness on sensitivity characteristics is discussed. The analysis is carried out on a bases off the effective index method used with the transfer matrix method.
Źródło:
Acta Physica Polonica A; 2013, 124, 3; 582-585
0587-4246
1898-794X
Pojawia się w:
Acta Physica Polonica A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Investigation of Free Space Optical Detection Module Operating at the Wavelength Range of 8-12 μm
Autorzy:
Gutowska, M.
Nowakowski, M.
Bielecki, Z.
Mikolajczyk, J.
Szabra, D.
Paliwoda, R.
Pedzinska, M.
Pawluczyk, J.
Gawron, W.
Powiązania:
https://bibliotekanauki.pl/articles/1506789.pdf
Data publikacji:
2010-12
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Tematy:
07.07.Df
85.60.Bt
Opis:
The paper presents the construction and test results of a long-term radiation detector module for free space optical communication operated at the wavelength range of 8-12 μm. In the module a Polish detector manufactured in the company Vigo System S.A. was applied. High sensitivity of the detection module was achieved through a multi-layered heterostructure HgCdTe with immersion lens, which is optimized for the radiation detection at the wavelength of 10 μm. Detector noises were reduced as a result of detector cooling by means of four-stage thermoelectric cooler. The developed detection module is dedicated to design a next-generation optical data link. The link will be characterized by a greater range in difficult weather conditions in relation to the currently offered links operating at the shorter wavelengths.
Źródło:
Acta Physica Polonica A; 2010, 118, 6; 1143-1147
0587-4246
1898-794X
Pojawia się w:
Acta Physica Polonica A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Optopneumatic Detector with Platinum Flow Sensor
Autorzy:
Jasek, K.
Budzyński, T.
Stryszak, E.
Powiązania:
https://bibliotekanauki.pl/articles/1796139.pdf
Data publikacji:
2009-09
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Tematy:
68.35.Iv
07.07.Df
Opis:
In optopneumatic detectors, operating on principle of the gaseous infrared detectors, the radiation absorbed in the gas is changed into pressure fluctuation, followed by periodic flow of the gas between detector chambers. This flow is usually measured by means of hot-wire or hot-film anemometers. Their parameters in a great measure determine the quality of the whole detector. The flow sensor used in optopneumatic detectors should have short time constant, high sensitivity, possibility to distinguish the flow direction, and high chemical resistance to the gas which the detector is filled with. To meet these requirements, micro-electro-mechanical system flowmeter consisting of two platinum hot films placed in series in the flow direction was made. Platinum film of 0.3 μm thickness was deposited by magnetron spattering on thin membrane, which was composed of polysilicon substrate (0.5 μm) and two $Si_{3}N_{4}$ layers with thickness of 0.1 μm. The obtained platinum elements have resistance of 32 Ω and temperature coefficient of resistance of 2.31× $10^{-3}$/°C. Hot film does not change its parameters up to 350°C, whereas typical working temperature of such films ranged from 150 to 200°C. Anemometer characteristics and voltage-current dependences were determined in this work. The linear range of operation from 0 to 10 ml/min and sensitivity suitable for optopneumatic detectors were found. The time constant of the flowmeter is equal to 11 ms (95% of final signal), that enables the detector to operate with frequency up to 100 Hz. The flowmeters were applied in detectors filled with sulphur dioxide and were tested for six months at temperature of hot-film about 150°C. During that time no changes of their parameters were observed.
Źródło:
Acta Physica Polonica A; 2009, 116, 3; 321-324
0587-4246
1898-794X
Pojawia się w:
Acta Physica Polonica A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Magnetic Fluxgate Sensor Characteristics Modeling Using Extended Preisach Model
Autorzy:
Frydrych, P.
Szewczyk, R.
Salach, J.
Powiązania:
https://bibliotekanauki.pl/articles/1199497.pdf
Data publikacji:
2014-07
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Tematy:
75.60.-d
07.07.Df
Opis:
This paper presents the implementation of the extended Preisach model for fluxgate sensor characteristics modeling. The developed model enables the optimization of fluxgate sensor parameters for a given core material. Model consists of two parts. The first one describes magnetic characteristics of the core, while the second part calculates output signal according to sensor dimensions and electric circuit parameters. The model is easy to adapt for modeling of other devices with magnetic cores. It can be used instead of costly and time consuming prototype testing.
Źródło:
Acta Physica Polonica A; 2014, 126, 1; 18-19
0587-4246
1898-794X
Pojawia się w:
Acta Physica Polonica A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analysis of the Responses of Metal-Oxide Semiconductor Nanostructures to Nitrogen Dioxide
Autorzy:
Procek, M.
Pustelny, T.
Powiązania:
https://bibliotekanauki.pl/articles/1399393.pdf
Data publikacji:
2013-09
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Tematy:
82.47.Rs
07.07.Df
Opis:
The paper concerns analyses of the nanostructures based on metal-oxide semiconductors, such as titanium dioxide $(TiO_2)$ and zinc oxide $(ZnO)$ exposed to nitrogen dioxide $(NO_2)$ in an atmosphere of dry and humid synthetic air. The investigations were performed at a rather low temperature amounting to 120°C. The responses of sensors differing in the morphology of their structures have been compared. Also the time of their responses were compared with each other. The paper describes theoretically changes in the effective resistance of these structures due to the interaction of the gas. The presented results are being discussed based on the analysis of physical and chemical phenomena.
Źródło:
Acta Physica Polonica A; 2013, 124, 3; 529-533
0587-4246
1898-794X
Pojawia się w:
Acta Physica Polonica A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
MMI Structures Covered by Bromocresol Purple for Ammonia Detection
Autorzy:
Szewczuk, A.
Błahut, M.
Powiązania:
https://bibliotekanauki.pl/articles/1399404.pdf
Data publikacji:
2013-09
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Tematy:
42.79.Gn
07.07.Df
Opis:
In the paper examinations of a lightguide sensor on the base of gradient index multimode interference structures are presented. Investigated structures were fabricated in potassium-sodium ion exchange process. Multimode interference sensor was designed for ammonia detection. Bromocresol purple covering the multimode section was used as a sensing layer. Numerical calculations were performed with the use of modal analysis and beam propagation method to optimise sensor geometry and sensing layer thickness. Experimental results show the possibility of ammonia detection from the concentration of tens ppm.
Źródło:
Acta Physica Polonica A; 2013, 124, 3; 570-573
0587-4246
1898-794X
Pojawia się w:
Acta Physica Polonica A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Pattern Recognition Applied to Analysis of Gas Sensors Array Data
Autorzy:
Marczyński, P.
Szpakowski, A.
Tyszkiewicz, C.
Pustelny, T.
Powiązania:
https://bibliotekanauki.pl/articles/1418023.pdf
Data publikacji:
2012-11
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Tematy:
02.50.Sk
07.07.Df
Opis:
For an array of eight chemoresistive gas sensors a computer pattern recognition system was built. Multivariate data analysis was performed for measurements of three gases' dilutions: hydrogen $(H_2)$, methane $(CH_4)$, and carbon monoxide $(CO)$. The pattern recognition system included a feature subset selection algorithm involving PCA and objective function. Dimensionality reduction was applied to two kinds of patterns: three aforementioned gases and six different concentrations of hydrogen. For patterns of the three gases, classification tests were performed using k-NN algorithm and N-fold based validation method.
Źródło:
Acta Physica Polonica A; 2012, 122, 5; 847-849
0587-4246
1898-794X
Pojawia się w:
Acta Physica Polonica A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Sensing Properties of Four-Layered Planar Waveguides - Theoretical Analysis
Autorzy:
Tyszkiewicz, C.
Powiązania:
https://bibliotekanauki.pl/articles/1418062.pdf
Data publikacji:
2012-11
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Tematy:
42.79.Gn
07.07.Df
Opis:
Optical waveguides are the fundamental components of chemical and biochemical evanescent wave sensors. Presented work focuses on the theoretical investigations of homogeneous sensitivity of four-layered composite planar waveguide composed of a silica-titania film and a titania film deposited on a glassy substrate in order of citing. Characteristics of a homogeneous sensitivity and a fundamental modes homogeneous sensitivity difference of such a structure are compared with the ones for a three-layered waveguide composed of silica-titania waveguiding film. Therefore the influence of a high refractive index titania film on homogeneous sensitivity characteristics of three-layered structure is given. It was shown that homogeneous sensitivity difference of fundamental modes of four-layered waveguide can be optimized with respect to thicknesses of each layer. For each value of a cover refractive index there exists the minimal thickness of the titania layer which maximizes the homogeneous sensitivity difference of fundamental modes.
Źródło:
Acta Physica Polonica A; 2012, 122, 5; 908-914
0587-4246
1898-794X
Pojawia się w:
Acta Physica Polonica A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Multivariate Analysis in Gas Sensing Applications
Autorzy:
Szpakowski, A.
Tyszkiewicz, C.
Pustelny, T.
Powiązania:
https://bibliotekanauki.pl/articles/1811555.pdf
Data publikacji:
2008-12
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Tematy:
02.50.Sk
07.07.Df
Opis:
In gas sensing applications we often use sensors which have poor selectivity. Such sensors are mature, cheap devices with simple application circuits. Unfortunately, their cross sensitivity greatly restricts their usefulness when used in systems which employs univariate analysis. One method which allows to overcome this difficulty is utilization of multivariate analysis methods applied to the response from the group of such non-selective sensors. This work presents the multivariate, pattern recognition system utilized to process the response of an array of non-selective semiconductor sensors to obtain the qualitative information.
Źródło:
Acta Physica Polonica A; 2008, 114, 6A; A-239-A-242
0587-4246
1898-794X
Pojawia się w:
Acta Physica Polonica A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Supervising water quality of water resources via telemetric system
Autorzy:
Üncü, İ.
Akdurul, M.
Powiązania:
https://bibliotekanauki.pl/articles/1061570.pdf
Data publikacji:
2016-07
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Tematy:
06.20.Dk
07.07.Df
07.88.+y
Opis:
Urban water resources are some of the main places where microorganisms can reproduce and where people can get easily infected. For these reasons, pools must be sterilized continuously. This can only be done if the water quality of the pool is in accordance with the standards of the Ministry of Forestry and Water Affairs. Monitoring water quality in real-time gives an instant response opportunity. With the software prepared using the. Net architecture, real-time temperature, pH, and chlorine content values of a pool were transferred to a database. Swimming pool water quality was then evaluated and compared with the Ministry of Forestry and Water Affairs standards via the expert system technique, which is one of the artificial intelligence technologies. In this study, results of instant evaluation of the water quality made for water resources via telemetric systems, are reported. Additionally, a remotely-controlled dosing operation was performed.
Źródło:
Acta Physica Polonica A; 2016, 130, 1; 293-296
0587-4246
1898-794X
Pojawia się w:
Acta Physica Polonica A
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies