Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "“trigger”" wg kryterium: Temat


Tytuł:
Two dimensional model of CMM probing system
Autorzy:
Ali, Salah H.R.
Powiązania:
https://bibliotekanauki.pl/articles/950738.pdf
Data publikacji:
2010
Wydawca:
Sieć Badawcza Łukasiewicz - Przemysłowy Instytut Automatyki i Pomiarów
Tematy:
CMM
trigger probe
stylus tip
tip root errors
and two-dimensional-model (2DM)
Opis:
A coordinate measuring machine (CMM) as an automation technology is playing the key role in the modern industry to improve the measurement accuracy. Accurate probing that is computer controlled is the current trend for the next generation of coordinate metrology. However, the CMM probing system is limited by its dynamic root errors that may markedly affect its response characteristics. In this paper, dynamic response errors of CMM measurements have been analyzed. The adopted probe stylus sizes throughout the course of measurements are found to cause some waviness errors during CMM operations due to each of the prescribed angle of the probe tip contact point with the specimen surface and the radius of the stylus tip. Variations in the geometry of the stylus have their consequent effects on its inherent intrinsic dynamic characteristics that in turn would cause relevant systematic root errors in the resulted measurements. Unforeseeable geometrical errors of a CMM using a ductile touch-trigger probing system have been characterized theoretically. These results are analyzed in order to investigate the effect of the dynamic root errors in the light of six probe stylus tip of the situation into account when assessing the accuracy of the CMM measurements. Analytical approaches have been applied on a developed two dimensional model (2DM) of stylus tip to demonstrate the capability of such approaches of emphasizing the root error concept using the strategy of CMM ductile trigger type of probe.
Źródło:
Journal of Automation Mobile Robotics and Intelligent Systems; 2010, 4, 2; 3-7
1897-8649
2080-2145
Pojawia się w:
Journal of Automation Mobile Robotics and Intelligent Systems
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analiza systemów zbierania danych pomiarowych z urządzeń do badań tribologicznych
The analysis of measurement data collection systems from the tribotesters
Autorzy:
Bator, A.
Duda, P.
Michalczewski, R.
Służałek, G.
Wróbel, Z.
Powiązania:
https://bibliotekanauki.pl/articles/188878.pdf
Data publikacji:
2012
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
charakterystyki tribologiczne
układ pomiarowy
wyzwalanie pomiarów w punkcie
friction
wear
measuring system
tribological characteristics
trigger point
Opis:
Przeprowadzając modelowe badania tribologiczne, dążąc do uzyskania wysokiej powtarzalności i odtwarzalności wyników, szczególną uwagę zwraca się na precyzyjne zadanie parametrów testu (prędkość ślizgania i obciążenie węzła) oraz kontrolę warunków otoczenia (temperatura, wilgotność). Jednocześnie często marginalizuje się sprawy związane z niedokładnością wykonania próbek. Niedokładności struktury geometrycznej powierzchni i kształtu są często spowodowane dodatkowymi procesami technologicznymi, realizowanymi po precyzyjnym wykonaniu bazy próbki. Powoduje to często zwiększenie bicia osiowego i promieniowego próbek. Może to spowodować błędną interpretację pomiaru intensywności zużywania liniowego oraz siły tarcia. W celu wyeliminowania wpływu bicia osiowego na pomiar intensywności zużywania liniowego, autorzy opracowali koncepcję oraz zaprojektowali i wykonali zautomatyzowany, sterowany komputerowo układ wyzwalania pomiaru charakterystyk tribologicznych w funkcji położenia tarczy, a nie, jak dotychczas, w funkcji czasu. System ten zastosowano w stanowisku T-01M opracowanym w ITeE – PIB Radom. Zmodyfikowane stanowisko poddano badaniom dwóch rodzajów skojarzeń materiałowych i przy dużej zmienności prędkości obrotowej węzła. Dodatkowo porównano wyniki charakterystyk tribologicznych uzyskane ze standardowego układu pomiarowego wyzwalanego czasem z uzyskanymi za pomocą opracowanego systemu. Z przeprowadzonych badań wynika, że stosowanie zautomatyzowanego systemu wyzwalania pomiaru w funkcji położenia tarczy powala na znaczne zmniejszenie rozrzutu wyników pomiarów przy niskich prędkościach obrotowych, a tym samym na poprawę powtarzalności i odtwarzalności badań tribologicznych w układzie kula–tarcza i trzpień–tarcza.
When conducting tribological model studies with the aim of achieving a high repeatability and reproducibility of results, much attention is paid to the precise setting of test parameters. Most of all, setting the sliding speed and normal load is made with great care. Ambient conditions (temperature, humidity) are also controlled. At the same time, issues related to inaccuracy in making samples are often marginalized. Inaccuracies in surface geometric texture and shape are often caused by additional technological processes carried out after a precise execution of the sample base. This often increases the axial and radial run-out of samples. Moreover, it may lead to a misinterpretation of the measurement of linear wear intensity and friction. In order to eliminate the impact of the axial run-out on the measurement of linear wear intensity, the authors have developed a concept as well as designed and built an automated computer-controlled system of triggering the measurement of tribological characteristics as a function of a disc position, which is no longer as a function of time. This system was applied in the system of the T-01M produced by ITeE – PIB Radom. The modified system was tested on two types of material combinations and with a high variability of the speed of the node. In addition, the results of tribological characteristics obtained with a standard measuring system triggered with time were compared with those obtained using the developed system. The study shows that the use of an automated system of triggering measurement as a function of a disc position enables a considerable decrease in scattering measurement results at low engine speeds, thereby improving repeatability and reproducibility of tribological studies in the system ball-on-disc and pin-on-disc.
Źródło:
Tribologia; 2012, 6; 25-35
0208-7774
Pojawia się w:
Tribologia
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
KLAUZULE RATING TRIGGERS ORAZ ZAGROŻENIE DLA STABILNOŚCI RYNKU Z NICH WYNIKAJĄCE
Autorzy:
Bloch, Dorota
Powiązania:
https://bibliotekanauki.pl/articles/654317.pdf
Data publikacji:
2014
Wydawca:
Uniwersytet Łódzki. Wydawnictwo Uniwersytetu Łódzkiego
Tematy:
ryzyko kredytowe
credit rating
rating trigger
credit cliff
Opis:
Rating jest powszechnie wykorzystywanym narzędziem na rynku finansowym. Obok zastosowaniago dla celów tworzenia portfela inwestycyjnego czy określenia wymogów kapitałowychcoraz szersze staje się wykorzystanie ratingu w umowach prywatnych między dawcą i biorcąkapitału, tzw. klauzulach rating triggers. Zasadniczym celem opracowania jest przedstawieniedowodów na prawdziwość tezy, iż klauzule te, tworzone w celu ochrony kapitału kredytodawcy,mogą de facto prowadzić do poważnych zagrożeń zarówno dla kredytodawcy, kredytobiorcy,a w określonych warunkach nawet dla stabilności całego rynku. W niniejszym opracowaniu autorkawyjaśnia czym są klauzule rating triggers, dokonuje klasyfikacji podstawowych rodzajówwyzwalaczy ratingowych ze względu na konsekwencje, jakie niosą dla kredytobiorców oraz opisujejedno z najpoważniejszych zagrożeń związanych z tymi klauzulami, a mianowicie zjawiskocredit cliff. Artykuł kończy się analizą przypadków credit cliff potwierdzających destrukcyjny wpływ aktywowania się tego rodzaju klauzuli zarówno na podmiot je podpisujący jak i na rynek jako całość.
Źródło:
Acta Universitatis Lodziensis. Folia Oeconomica; 2014, 2, 301
0208-6018
2353-7663
Pojawia się w:
Acta Universitatis Lodziensis. Folia Oeconomica
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Usefulness of English Corpora Regarding Encyclopedic Meaning of Grammatical Constructions: Count Noun Vs. Non-Count Noun, Noun Vs. Verb
Użyteczność angielskich korpusów w odniesieniu do encyklopedycznego znaczenia konstrukcji gramatycznych: rzeczownik policzalny vs. niepoliczalny, rzeczownik vs. czasownik
Autorzy:
Chłopek, Dorota
Powiązania:
https://bibliotekanauki.pl/articles/29520287.pdf
Data publikacji:
2022-12-20
Wydawca:
Uniwersytet Bielsko-Bialski
Tematy:
linguistic construction
corpus
concordances
grammar
encyclopedic meaning
“trigger”
“target”
konstrukcja językowa
korpus
konkordancje
gramatyka
forma „docelowa”
element „zapalnik”
znaczenie encyklopedyczne
Opis:
The article attempts to demonstrate how concordance lines of a linguistic corpus can be useful in assignments on the descriptive grammar of english, which are administered on-line via the Ms Teams application of teaching and learning due to the Sars-CoV-2 pandemic. Grammatical expressions are approached as constructions abstracted from situated instances of language use in view of Langacker’s “symbolic principle”, which is consistent with the “usage-based principle” and the encyclopedic nature of meaning. Accordingly, words are points of access to extensive depositories of knowledge. Linguistic corpora can provide vast repositories of patterns of use of particular key words constituting various linguistic constructions. The paper focuses on distinguishing between English count nouns and mass nouns represented by the same lexical form, called a “target”, such as worry, dinner, and work, and exposes worry and work as verbs in alternative contexts of use cited from concordance lines of the BNC. The term work is also shown as a key word whose lexical category, noun or verb, is determined on the basis of other elements, referred to as “triggers” in the context of occurrence.
Źródło:
Świat i Słowo; 2022, 38, 1; 159-176
1731-3317
Pojawia się w:
Świat i Słowo
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Differential diagnosis between fibromyalgia syndrome and myofascial pain syndrome
Autorzy:
Chochowska, M.
Szostak, L.
Marcinkowski, J.T.
Jutrzenka-Jesion, J.
Powiązania:
https://bibliotekanauki.pl/articles/3306.pdf
Data publikacji:
2015
Wydawca:
Instytut Medycyny Wsi
Tematy:
diagnosis
fibromyalgia syndrome
myofascial pain syndrome
trigger mechanism
human disease
Opis:
Introduction. Fibromyalgia syndrome (FMS) and myofascial pain syndrome (MFPS) can be ranked among disease entities being difficult to diagnose clinically, manifesting themselves mainly through pain in specific hypersensitivity points. Aim. To present the current state of medical knowledge about pain spots appearing on hypersensitive points of soft tissue in the context of selected disease entities. Summary of the knowledge. MFPS is defined as sensory, motor and autonomic complaints, caused by the occurrence of trigger points (TrP). Yet the FMS is stated during the anamnesis on the basis of generalized pain, and pressure achiness of at least 11 out of 18 tender points (TP) of precisely determined location. Patients with FMS report numerous additional complaints – apart from the above mentioned ones; these are however highly non-specific and are not confirmed during routine medical check-ups. There are also no laboratory tests that can confirm presence of TrP being characteristic to MFPS and differentiating it from other muscles’ disease entities. Such points are identified only with the use of palpation. Unfortunately while examining a patient this way TrP – being symptoms of MFPS – can be quite easily confused with TP – being symptoms of FMS. Patients with MFPS which is developing in consequence of long-lasting global disorder of muscle tension balance and sensitivity of nociceptors as a result of chronically remaining pain, frequently suffer from achiness fulfilling the criteria of generalized pain. Moreover – in effect of static overload of soft tissues (especially of tonic muscles) – there occur hypersensitive palpable areas (points). Stimulating them cause lively reaction of the patient. Described symptoms can suggest a suspicion of FMS – the more so that making a diagnosis of MFPS does not exclude its coexistence. Having this in mind, there is a pretty large group of authors who raise a supposition that the differential diagnosis between TrP and TP should be observed in the quantitative rather than in the qualitative categories, despite the still binding definition and nomenclature. Recapitulation. Looking at the MFPS and at the FMS from the perspective of evolution of knowledge about them and from the point of view of period when scientific researches were conducted and their results published, it must be stated that during last years a considerable progress has been obtained in scope of better understanding of pathogenesis and pathophysiology of pain in specified points of soft tissue hypersensitivity, and the parallel clinical studies – confirming the hypotheses that were made – clearly increased the diagnostic and therapeutic capabilities of clinical practice.
Źródło:
Journal of Pre-Clinical and Clinical Research; 2015, 09, 1
1898-2395
Pojawia się w:
Journal of Pre-Clinical and Clinical Research
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
What does it take to be a copula?
Autorzy:
Dalmi, Gréte
Powiązania:
https://bibliotekanauki.pl/articles/1152523.pdf
Data publikacji:
2016
Wydawca:
Uniwersytet im. Adama Mickiewicza w Poznaniu
Tematy:
zero copula
alternative trigger
scope ambiguities
Opis:
This paper argues that copular sentences without an overt copular predicate do project a VP with a phonologically null head, hence so-called “verbless” copular sentences are illusory. Data from Standard Arabic, Spanish, Maltese, Russian, Jamaican Creole, Finnish and Hungarian copular sentences are used to support this claim. It is also claimed here that variation between the habitual property vs. ad hoc property interpretations (traditionally called the individual level vs. stage level distinction) of non-verbal predicates found in copular sentences is closely related to the choice of the copula in multiple BE-system languages. Whilst the current accounts explain this variation by introducing an abstract aspectual operator or an incorporated abstract preposition in the functional layer of the copular predicate, the present proposal derives these interpretive differences from the presence or absence of an OPalt alternative state operator, which can bind the temporal variable of non-verbal predicates in two ways. Negation and temporal adverbials show scope ambiguity in copular sentences. They either take scope over the whole proposition or only over the non-verbal predicate. Such interpretive differences are demonstrated in Russian and Hungarian in Section 4 of this paper, however, they are taken to be valid cross-linguistically. These amibiguities cannot be explained under the “verbless copular sentence” account but fall out naturally from the “zero copula” analysis. The “alternative state” approach can be extended to dream narratives and other non-veridical contexts, which serve as alternative triggers. The existing analyses have nothing to say about such contexts.
Źródło:
Yearbook of the Poznań Linguistic Meeting; 2016, 2, 1
2449-7525
Pojawia się w:
Yearbook of the Poznań Linguistic Meeting
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
What does it take to be a copula?
Autorzy:
Dalmi, Gréte
Powiązania:
https://bibliotekanauki.pl/articles/2135366.pdf
Data publikacji:
2016-08-01
Wydawca:
Uniwersytet im. Adama Mickiewicza w Poznaniu
Tematy:
zero copula
alternative trigger
scope ambiguities
Opis:
This paper argues that copular sentences without an overt copular predicate do project a VP with a phonologically null head, hence so-called “verbless” copular sentences are illusory. Data from Standard Arabic, Spanish, Maltese, Russian, Jamaican Creole, Finnish and Hungarian copular sentences are used to support this claim. It is also claimed here that variation between the habitual property vs. ad hoc property interpretations (traditionally called the individual level vs. stage level distinction) of non-verbal predicates found in copular sentences is closely related to the choice of the copula in multiple BE-system languages. Whilst the current accounts explain this variation by introducing an abstract aspectual operator or an incorporated abstract preposition in the functional layer of the copular predicate, the present proposal derives these interpretive differences from the presence or absence of an OPalt alternative state operator, which can bind the temporal variable of non-verbal predicates in two ways. Negation and temporal adverbials show scope ambiguity in copular sentences. They either take scope over the whole proposition or only over the non-verbal predicate. Such interpretive differences are demonstrated in Russian and Hungarian in Section 4 of this paper, however, they are taken to be valid cross-linguistically. These amibiguities cannot be explained under the “verbless copular sentence” account but fall out naturally from the “zero copula” analysis. The “alternative state” approach can be extended to dream narratives and other non-veridical contexts, which serve as alternative triggers. The existing analyses have nothing to say about such contexts.
Źródło:
Yearbook of the Poznań Linguistic Meeting; 2016, 2, 1; 1-28
2449-7525
Pojawia się w:
Yearbook of the Poznań Linguistic Meeting
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
SURGICAL TREATMENT AND REHABILITATION OF TRIGGER THUMB AND FINGER
Autorzy:
Deskur, Anna
Deskur, Zbigniew
Powiązania:
https://bibliotekanauki.pl/articles/1054796.pdf
Data publikacji:
2017
Wydawca:
Uniwersytet Szczeciński. Wydawnictwo Naukowe Uniwersytetu Szczecińskiego
Tematy:
surgical treatment and rehabilitation of trigger thumb and finger
trigger thumb and finger
Opis:
The aim of the study was to evaluate the results of surgical treatment and rehabilitation of patients with trigger thumb and finger. In 40 patients, comprising 30 women and 10 men aged 26 to 64, a total of 42 cases of trigger thumb and finger. In the preoperative period, the severity of changes were studied according to the classification developed by Newport et al. Five patients were classified in the first stage, 28 in the second, 6 in the third, and 1 in the fourth. The mean duration of symptoms was five months. The indication for surgery was a lack of improvement following conservative treatment. All of the patients were treated surgically using the open method by cutting the flexor tendon sheath in part A1. The rehabilitation treatment included exercises to improve the range of mobility of the thumb and fingers and to stretch, grelax, and strengthen muscles. Neuromobilisation and automobilisation exercises were conducted. After 5 months, swelling, pain and restricted mobility of the thumb and fingers subsided in all patients. There were no ‘jumping’ symptoms. Apart from a slight transitory inflammatory reaction in 2 patients there were no complications. In patients with trigger finger, open surgery and competent rehabilitation therapy enables the achievement of very good results, with a low complication rate.
Źródło:
Central European Journal of Sport Sciences and Medicine; 2017, 17, 1; 61-66
2300-9705
2353-2807
Pojawia się w:
Central European Journal of Sport Sciences and Medicine
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
In the Search for Grammatical Explanations of the Code-Switching. Empirical Verification of Selected Syntactic Constraints and the Triggering Hypothesis
Autorzy:
Długosz, Kamil
Powiązania:
https://bibliotekanauki.pl/articles/605528.pdf
Data publikacji:
2016
Wydawca:
Uniwersytet Marii Curie-Skłodowskiej. Wydawnictwo Uniwersytetu Marii Curie-Skłodowskiej
Tematy:
Code-Switching
Syntax des Code-Switching
Auslösewörter
syntaktische Beschränkungen des Code-Switching
Mehrsprachigkeit
mentale Prozesse, mentale Sprachrepräsentation
code-switching
syntax of code-switching
bilingualism, trigger-words
syntactic constraints of the code-switching
mental processes
mental representation
Mots-clés:l’artenance codique
syntaxe de l’alternance codique
le bilinguisme, mots-déclencheurs
contraintes syntaxiques de l’alternance codique
processus mentaux
une représentation mentale
код коммутации
синтаксис кода коммутации
двуязычие, инициирующее слово
синтаксические ограничения кода коммутации
умственные процессы
ментальное представление
Opis:
Code-Switching ist ein Sprachkontaktphänomen und besteht in einem Wechsel zwischen zwei oder mehreren Sprachen bzw. Sprachvarietäten innerhalb einer Äußerung und kann entweder unbewusst oder bewusst ablaufen. Das Ziel des vorliegenden Artikels ist es, ausgewählte syntaktische Beschränkungen des Code-Switching, so wie sie in der Fachliteratur diskutiert werden, zur Debatte zu stellen und anhand einer Transkription eines Interviews mit dem berühmten Neurobiologen Eric Kandel (2011) empirisch zu überprüfen. Einer empirischen Überprüfung wird ebenfalls die Triggering-Hypothese (M. Clyne, 1967) unterzogen.
Code-switching appears among multilingual speakers and means switching fluently from one language to another. Since the 70s some research have been carried out on code-switching from the syntactic point of view. Its main purpose is to determine in which parts of a sentence code-switching cannot appear. The aim of the present study is to verify empirically the selected grammatical constraints on code-switching as well the Triggering-Hypothesis (Clyne 1967) on the basis of an interview transcript with a famous neurobiologist Eric Kandel.
Le numéro contient uniquement des résumés en anglais et en allemand.
Том не содержит аннотаций на русском языке.
Źródło:
Lublin Studies in Modern Languages and Literature; 2016, 40, 1
0137-4699
Pojawia się w:
Lublin Studies in Modern Languages and Literature
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Description of the pneumatic work cycle of the starting unit of the UAV launcher
Autorzy:
Jastrzębski, G.
Powiązania:
https://bibliotekanauki.pl/articles/247898.pdf
Data publikacji:
2017
Wydawca:
Instytut Techniczny Wojsk Lotniczych
Tematy:
launcher
pneumatic trigger
pneumatic system
Opis:
The publication presents a UAV pneumatic launcher designed and built in ITWL. The basic element of the pneumatic launcher is the launch mechanism. The starting mechanism determines the energy parameters that will be reached on the launch pad. The work of the launch engines used in propulsion systems has been reviewed and their advantages and disadvantages are discussed when used in pneumatic launchers. A detailed description of the author’s solution of the pneumatic launching mechanism from the launcher is presented. In order to determine guidelines for the design of pneumatic starter systems, a description of the cycle of operation of the complex pneumatic system was analysed. The description of the pneumatic system’s work cycle was based on the parameters of the flow of the compressed air C and b (C – the sound conductivity of the pneumatic element, b – the critical pressure of the pneumatic element). A set of equations describing the pressure change in the filled and emptied valve compartment and the equation of motion are presented. The equations of a mathematical model describing the pneumatic component and the replacement value of flow parameters for the pneumatic system of series pneumatic components are presented. For the mathematical model, a calculation algorithm is presented which takes into account the initial conditions and the boundary conditions of the various periods of the pneumatic system cycle. Examples of calculation results for a specific pneumatic trigger mechanism are shown. The results obtained were compared with the results of the pneumatic starter station tests and the mathematical model of the pneumatic starter was evaluated.
Źródło:
Journal of KONES; 2017, 24, 4; 61-70
1231-4005
2354-0133
Pojawia się w:
Journal of KONES
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Zero-Suppression Trigger Mode for GEM Detector Measurement System
Autorzy:
Kolasinski, Piotr
Pozniak, Krzysztof
Wojenski, Andrzej
Linczuk, Pawel
Krawczyk, Rafal
Gaska, Michal
Zabolotny, Wojciech
Kasprowicz, Grzegorz
Chernyshova, Maryna
Czarski, Tomasz
Powiązania:
https://bibliotekanauki.pl/articles/1844608.pdf
Data publikacji:
2021
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
FPGA
GEM
trigger
sequencer
DAQ
Xilinx
Opis:
A novel approach to a trigger mode in the Gas Electron Multiplier (GEM) detector readout system is presented. The system is already installed at WEST tokamak. The article briefly describes the architecture of the GEM detector and the measurement system. Currently the system can work in two trigger modes: Global Trigger and Local Trigger. All trigger processing blocks are parts of the Charge Signal Sequencer module which is responsible for transferring data to the PC. Therefore, the article presents structure of the Sequencer with details about basic blocks, theirs functionality and output data configuration. The Sequencer with the trigger algorithms is implemented in an FPGA chip from Xilinx. Global Trigger, which is a default mode for the system, is not efficient and has limitations due to storing much data without any information. Local trigger which is under tests, removes data redundancy and is constructed to send only valid data, but the rest of the software, especially on the PC side, is still under development. Therefore authors propose the trigger mode which combines functionality of two existing modes. The proposed trigger, called Zero Suppression Trigger, is compatible with the existing interfaces of the PC software, but is also capable to verify and filter incoming signals and transfer only recognized events. The results of the implementation and simulation are presented.
Źródło:
International Journal of Electronics and Telecommunications; 2021, 67, 1; 103-108
2300-1933
Pojawia się w:
International Journal of Electronics and Telecommunications
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The ATLAS experiment on-line monitoring and filtering as an example of real-time application
System monitoringu i filtracji eksperymentu ATLAS jako przykład aplikacji czasu rzeczywistego
Autorzy:
Korcyl, K.
Szymocha, T.
Funika, W.
Kitowski, J.
Słota, R.
Bałos, K.
Dutka, Ł.
Guzy, K.
Kryza, T.
Pieczykolan, J.
Powiązania:
https://bibliotekanauki.pl/articles/305349.pdf
Data publikacji:
2008
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie. Wydawnictwo AGH
Tematy:
fizyka wysokich energii
przetwarzanie w czasie rzeczywistym
system filtracji
zdalne farmy
high energy physics
real-time procesing
trigger system
remote farms
Opis:
The ATLAS detector, recording LHC particles' interactions, produces events with rate of 40 MHz and size of 1.6 MB. The processes with new and interesting physics phenomena are very rare, thus an efficient on-line filtering system (trigger) is necessary. The asynchronous part of that system relays on few thousands of computing nodes running the filtering software. Applying refined filtering criteria results in increase of processing times what may lead to lack of processing resources installed on CERN site. We propose extension to this part of the system based on submission of the real-time filtering tasks into the Grid.
Detektor ATLAS, rejestrujący zderzenia protonów rozpędzanych w zderzaczu LHC, będzie generował przypadki o rozmiarze 1.6MB z częstotliwością 40MHz. Aby wyselekcjonować bardzo rzadko występujące przypadki z interesującymi oddziaływaniami fizycznymi, konieczne będzie zastosowanie wydajnego systemu filtracji (trigger). Część asynchroniczna takiego systemu wykorzystuje kilka tysięcy komputerów, na których wykonywane jest oprogramowanie filtrujące. Zwiększenie selektywności systemu wymaga zwiększenia czasu procesowania, co może doprowadzić do wyczerpania zasobów komputerowych zainstalowanych w CERN-ie. Proponujemy rozszerzenie tej części systemu poprzez umożliwienie wykonywania oprogramowania filtrującego w czasie rzeczywistym na komputerach w środowisku gridowym.
Źródło:
Computer Science; 2008, 9; 77-86
1508-2806
2300-7036
Pojawia się w:
Computer Science
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Porównanie wpływu techniki energii mięśniowej powtórzonej jednokrotnie i trzykrotnie na zmianę progu bólu i parametrów elektrofi zjologicznych mięśnia czworobocznego grzbietu
Comparison of the effect of the muscle energy technique repeated once and three times on the change of pain threshold and electrophysiological parameters of the trapezius muscle
Autorzy:
Kurowski, Paweł
Jancarzyk, Dawid
Powiązania:
https://bibliotekanauki.pl/articles/2176260.pdf
Data publikacji:
2020-12
Wydawca:
Uniwersytet Jagielloński. Collegium Medicum
Tematy:
techniki energii mięśniowej
punkty spustowe
próg bólu
EMG
muscle energy techniques
trigger points
pain treshold
Opis:
Celem pracy było porównanie efektu techniki energii mięśniowej powtórzonej jednokrotnie (grupa A) i trzykrotnie (grupa B), na próg bólu i parametry EMG mięśnia czworobocznego grzbietu. W badaniu udział wzięło 28 osób z utajonym punktem spustowym w badanym mięśniu. Za pomocą EMG oceniono biopotencjał mięśnia podczas spoczynku i ruchu uniesienia barków. Uciskowy próg bólu mierzono z użyciem dynamometru ręcznego. Badane parametry oceniono przed terapią i po jej zakończeniu. W każdej z grup zaobserwowano istotny wzrost średnich wartości progu bólu; w grupie A ponadto zaobserwowano statystycznie istotny spadek napięcia spoczynkowego mięśnia. Inne mierzone parametry nie wykazały istotnych zmian. Zdaniem autorów jedno wykonanie techniki pozwala osiągać zamierzone efekty terapeutyczne i nie powoduje zbyt dużego bodźcowania tkanki.
The aim of the study was to compare the effect of the muscle energy technique repeated once (group A) and three times (group B), on the pain threshold and EMG parameters of the trapezius muscle. The study involved 28 people with a latent trigger point in the examined muscle. EMG was used to assess the biopotentials of the muscle during rest and shoulder lift movement. Pain threshold pressure was measured using a manual dynamometer. The examined parameters were evaluated before and after the therapy. In each group a significant increase in average pain threshold values was observed, in group A a statistically significant decrease in resting muscle tension was also observed. Other measured parameters showed no significant changes. According to the authors, one technique allows to achieve the intended therapeutic effects and does not cause too much tissue stimulation.
Źródło:
Sztuka Leczenia; 2020, 35, 2; 43-52
1234-7175
1898-2026
Pojawia się w:
Sztuka Leczenia
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Rhomboid major muscle ultrasound-guided trigger point injection: a case report and technique description
Iniekcja punktu spustowego mięśnia równoległobocznego większego wykonywana pod kontrolą ultrasonografii: opis przypadku oraz opis techniki
Autorzy:
Leiva Pemberthy, Luz Miriam
Gallego, Daniel F
Zuluaga Ruiz, Maria Eugenia
Powiązania:
https://bibliotekanauki.pl/articles/1790773.pdf
Data publikacji:
2020-11-10
Wydawca:
Akademia Wychowania Fizycznego im. Bronisława Czecha w Krakowie
Tematy:
myofascial pain syndrome
ultrasound guidance
myofascial trigger point
trigger point injection
mięśniowo-powięziow y zespół bólowy
kontrola USG
mięśniowo-powięziowe punkty spustowe
iniekcja punktu spustowego
Opis:
Introduction: Myofascial pain syndrome is an acute and chronic painful musculoskeletal condition that involves muscle and surrounding connective tissue. Trigger point injection is a common treatment for this condition providing long-term relief. The procedure is generally safe; however some side effects have been reported including pain, nerve injury, bleeding, infection, and pneumothorax. Objective: To report a case of a patient with myofascial pain syndrome successfully treated by Ultra Sound-guided infiltration of a myofascial trigger point in the rhomboid major muscle. Case description: A 39-year-old presented with cervical and dorsal pain of 4 months of evolution. She had physical and occupational therapy, with partial improvement of cervical pain but persistence of dorsal pain. No abnormal finding was noted on the neurological examination. On palpation, the patient had a myofascial trigger point in the left rhomboid major muscle. Given the persistence of the myofascial trigger point after physical therapy, it was considered the patient might benefit from Ultra Sound-guided infiltration. No adverse events were reported. At the end of the procedure, the patient reported a 70% reduction in pain. The patient returned for a follow-up visit one month after the procedure, reporting pain relief of 80%. Conclusions: The use of an Ultra Sound-guided technique for trigger point injection decreases the risk of iatrogenic complications. The blind method may result in poor localization of the point. Further studies are required to develop Ultra Sound based criteria to determine its clinical use.
Wstęp: Mięśniowo-powięziowy zespół bólowy jest ostrym, przewlekłym i bolesnym stanem układu mięśniowo-szkieletowego, który obejmuje mięśnie oraz otacząjącą je tkankę łączną. Zastrzyk do punktu spustowego jest powszechnym sposobem leczenia tego schorzenia, dającym długotrwałą ulgę. Procedura jest generalnie bezpieczna; jednakże zgłaszano pewne objawy niepożądane takie jak ból, uszkodzenie nerwu, krwawienie, infekcję, oraz odmę opłucnową. Cel: Opis przypadku pacjentki z mięśniowo-powięziowym zespołem bólowym leczonej skutecznie za pomocą infiltracji pod kontrolą USG mięśniowo-powięziowego punktu spustowego w mięśniu równoległobocznym większym. Opis przypadku: 39-letnia pacjentka, z występującym od 4 miesięcy bólem szyjnym i grzbietowym. Po fizjoterapii oraz terapii zajęciowej, ból szyi częściowo złagodniał ale ból grzbietu utrzymywał się. W badaniu neurologicznym nie stwierdzono żadnych nieprawidłowości. Podczas badania palpacyjnego, w lewym mięśniu równoległobocznym większym pacjentki wykryto mięśniowo-powięziowy punkt spustowy . Biorąc pod uwagę utrzymywanie się mięśniowo-powięziowego punktu spustowego po fizjoterapii, uznano, że pacjentce mogłaby pomóc infiltracja po kontrolą ultrasonografii. Nie zgłoszono żadnych niepożą danych reakcji. Pod koniec zabiegu, pacjentka stwierdziła zmniejszenie nasilenia bólu o 70%. Miesiąc po zabiegu, pacjentka przyszła na wizytę kontrolną zgłaszając złagodzenie bólu o 80%. Wnioski: Zastosowanie techniki z użyciem ultrasonografii do iniekcji punktu spustowego zmniejsza ryzyko wystąpienia powikłań jatrogennych. Metoda “ślepa”, tj. bez zastosowania USG, może skutkować nieodpowiednią lokalizacją punktu. Potrzebne są dalsze badania w celu opracowania kryteriów opartych na ultrasonografii aby móc określić jej kliniczne zastosowanie.
Źródło:
Medical Rehabilitation; 2020, 24(3); 25-28
1427-9622
1896-3250
Pojawia się w:
Medical Rehabilitation
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Układ do zsynchronizowanych pomiarów sygnałów z czujników tensometrycznych
Strain gauges synchronized measurement system
Autorzy:
Majcher, A.
Mrozek, M.
Przybylski, J.
Zbrowski, A.
Powiązania:
https://bibliotekanauki.pl/articles/257978.pdf
Data publikacji:
2010
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Technologii Eksploatacji - Państwowy Instytut Badawczy
Tematy:
monitorowanie udarów
udar o dużej prędkości
wyzwalanie pomiarów
czujnik tensometryczny
programowanie LabView
impact monitoring
high velocity impact
measurement trigger
strain gauge
LabView programming
Opis:
W artykule przedstawiono rozwiązanie układu do zsynchronizowanego dynamicznego pomiaru sygnałów z rezystancyjnych czujników tensometrycznych. Synchronizacja korzysta z trzech metod: wyzwalania sygnałem cyfrowym (zdarzeniem), wykrywania odpowiedniej wartości mierzonego sygnału analogowego, wyzwalania sygnałem aktywacji, po którym następuje zmienny interwał czasowy do chwili odpowiedzi czujników. Scharakteryzowano każdą z metod w aspekcie zastosowania układu do pomiarów efektów uderzeń obiektów o dużych prędkościach. Opisany układ może znaleźć zastosowanie w monitorowaniu i analizie uszkodzeń, pracach związanych z dynamiką płynów i gazów, akustyką, badaniami wytrzymałościowymi materiałów i obiektów.
The article describes system for synchronised measurements of signals from strain gauges. Synchronization utilises three methods: event driven triggering by digital signal, detecting the suitable value of measured analog signal, triggering by the starting of the pulse used to activate the actuator after which stochastic interval follows till the moment of the answer of sensors. The methods were characterised in terms of the application of the system in the measurement of impact effects of high velocity objects. The described system can be used in monitoring and fault detection, in works connected with dynamics of liquids and gases, acoustics, the analysis of materials the and objects damages.
Źródło:
Problemy Eksploatacji; 2010, 4; 59-66
1232-9312
Pojawia się w:
Problemy Eksploatacji
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies