Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "ścięgno" wg kryterium: Temat


Wyświetlanie 1-11 z 11
Tytuł:
Comparison of different suture techniques for Achilles tendon repair in rat model using collagen scaffolds
Autorzy:
Gabler, C.
Gierschner, S.
Tischer, T.
Bader, R.
Powiązania:
https://bibliotekanauki.pl/articles/306448.pdf
Data publikacji:
2018
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
ścięgno
model zwierzęcy
biomechanika
tendon repair
suture techniques
scaffolds
animal model
Opis:
Tendon injury is an increasing problem in medicine due to aging of the population and increased activity demands. Many rodent animal models are used in order to evaluate tendon reconstruction. Although tendon reruptures are a known problem, the outcomes of tendon repair in animal models are rarely discussed in the literature. The goal of the present experimental study was to compare the primary fixation stability of three suture techniques for repair of Achilles tendon defects in a rat model using a collagen scaffold. Methods: Cadaveric left hind limbs of Sprague-Dawley rats were prepared with an Achilles tendon defect of 3 mm and rejoined using a collagen scaffold. Three suture configurations (simple, simple stitch with additional framing suture, and modified Mason–Allen stitch; n = 5 each) underwent tensile testing until complete failure was observed. Results: Under a load of a mean value of 6.6 N, the failure load of simple stitches was the significantly lowest ( p < 0.01). Both, modified Mason–Allen stitches and simple stitches with additional framing suture showed a mean failure load of more than 14 N. Regardless of the suture technique, most of the samples showed failure of tendon due to suture tear-out. The suture material as well as the scaffold remained mostly intact. Conclusions: Although simple end-toend suture techniques are common in the literature, stitches with more suture strands should be preferred. Using techniques like an additional framing suture or modified Mason–Allen stitch, maximum failure load can be doubled and the risk of tendon rerupture may be decreased in vivo.
Źródło:
Acta of Bioengineering and Biomechanics; 2018, 20, 2; 73-77
1509-409X
2450-6303
Pojawia się w:
Acta of Bioengineering and Biomechanics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
A biomechanical model of operated achilles tendon
Autorzy:
Stavrov, V. P.
Lashkovski, V.
Sviridenok, A.
Powiązania:
https://bibliotekanauki.pl/articles/387190.pdf
Data publikacji:
2009
Wydawca:
Politechnika Białostocka. Oficyna Wydawnicza Politechniki Białostockiej
Tematy:
ścięgno Achillesa
biomechanika
modelowanie
odbudowa
Achilles tendon
biomechanics
modelling
recovery
Opis:
The paper discusses a biomechanical model reflecting deformation and tear of a tendon part, namely, ellipric in cross-section strand formed by stochastically located collagen fibers whose strain to stress relation obeys the exponential law. Recovery of the tendon by a plastic reinforcement is shown to result in elevated rigidity and shorter limiting elongation of the strand proportionally to the reinforced portion length, the strength of the restored strand being preserved almost fully. The limiting deformation of the recovered strand made with incisions for adaptation of the ends increases the more the deeper are the incisions, their number and the total length of the areas being adapted. This, nevertheless, decreases essentially the breaking load during further loading.
Źródło:
Acta Mechanica et Automatica; 2009, 3, 4; 69-72
1898-4088
2300-5319
Pojawia się w:
Acta Mechanica et Automatica
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wyznaczenie właściwości mechanicznych ścięgien świńskich do zastosowań ksenogenicznych
Determination of mechanical properties swine tendons for xenogenic transplantations
Autorzy:
Gzik-Zroska, Β.
Joszko, K.
Rostocka, J.
Powiązania:
https://bibliotekanauki.pl/articles/99130.pdf
Data publikacji:
2017
Wydawca:
Politechnika Śląska. Katedra Biomechatroniki
Tematy:
statyczna próba rozciągania
ścięgno
moduł Younga
static tensile test
tendon
Young's modulus
Opis:
W pracy przedstawiono wyniki badań doświadczalnych przeprowadzonych na ścięgnach przednich kończyn świńskich. Badania przeprowadzono przy użyciu maszyny wytrzymałościowej MTS Insight. W ramach badań wyznaczono wartości modułu Younga, naprężeń oraz odkształceń ścięgien palców przednich jako preparatów do zastosowań ksenogenicznych.
In this paper it was presented the results of experimental investigations, performed on the swine tendons samples dissected from anterior limbs. The main aim of investigations was to determine the mechanical properties of swine tendons for xenogenic applications. The tests were carried out with the use of MTS Insight static machine. It was determined the Young's modulus values and also the stress and strains of tendons that occurs during the static tensile test.
Źródło:
Aktualne Problemy Biomechaniki; 2017, 14; 17-22
1898-763X
Pojawia się w:
Aktualne Problemy Biomechaniki
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Internal snapping hip syndrome in dynamic ultrasonography
Zespół trzaskającego biodra w dynamicznym badaniu ultrasonograficznym
Autorzy:
Piechota, Małgorzata
Maczuch, Jarosław
Skupiński, Jarosław
Kukawska-Sysio, Karolina
Wawrzynek, Wojciech
Powiązania:
https://bibliotekanauki.pl/articles/1052575.pdf
Data publikacji:
2016
Wydawca:
Medical Communications
Tematy:
dynamiczna ultrasonografia
zespół trzaskającego biodra
ścięgno mięśnia biodrowo-lędźwiowego
snapping hip syndrome
Opis:
Snapping hip syndrome is an audible or palpable snap in a hip joint during movement which may be accompanied by pain or locking. It is typically seen in young athletes performing activities requiring repeated extreme movements of the hip. It may also follow a physical trauma, intramuscular injections or surgeries. There are two main forms of snapping hip: extra- or intra-articular. Extra-articular snapping hip is elicited by an abnormal movement of specific tendons and is divided into two forms: internal and external. The internal form of snapping hip syndrome is attributed to an abrupt movement of an iliopsoas tendon against an iliopectineal eminence. Radiograph results in patients with this form of snapping tend to be normal. Dynamic ultrasound is the gold standard diagnostic technique in both forms of extra-articular snapping hip syndrome. The objective of the following text is to describe a step-by-step dynamic ultrasonography examination in internal extra-articular snapping hip syndrome in accordance to the proposed checklist protocol. To evaluate abrupt movement of an involved tendon, the patient needs to perform specific provocation tests during the examination. With its real-time imaging capabilities, dynamic ultrasonography detects the exact mechanism of the abnormal tendon friction during hip movement in a noninvasive way. It also allows for a diagnosis of additional hip tissue changes which may be causing the pain.
Zespół trzaskającego biodra klinicznie manifestuje się słyszalnym lub odczuwalnym przez pacjenta przeskakiwaniem w stawie biodrowym podczas ruchu, któremu może towarzyszyć ból oraz blokowanie w stawie. Problem ten najczęściej dotyczy młodych sportowców wykonujących powtarzalne ćwiczenia z wykorzystaniem pełnego zakresu ruchu w stawie biodrowym. Przyczyną zespołu trzaskającego biodra mogą być również: przebyty uraz, ostrzykiwanie okolicy biodra lub zabieg chirurgiczny. Ze względu na etiologię zespołu trzaskającego biodra wyróżnia się jego dwie podstawowe formy: wewnątrz i zewnątrzstawową. Zespół zewnątrzstawowy jest związany z nieprawidłowym ruchem ścięgien i w zależności od nieprawidłowego ruchu danej struktury anatomicznej może występować jako forma wewnętrzna lub zewnętrzna. Złotym standardem w obrazowaniu zewnątrzstawowego zespołu trzaskającego biodra jest dynamiczne badanie ultrasonograficzne. W pracy zaprezentowano schemat dynamicznego badania ultrasonograficznego u pacjentów z podejrzeniem zewnątrzstawowego zespołu trzaskającego biodra o podtypie wewnętrznym. Aby prawidłowo ocenić ruchomość ścięgien biorących udział w zespole trzaskającego biodra, konieczne jest przeprowadzenie testów prowokacyjnych. Ultrasonografia ze względu na możliwość obrazowania poruszających się ścięgien w czasie rzeczywistym pozwala na nieinwazyjne zobrazowanie dokładnego mechanizmu konfliktowania ścięgna. Dodatkowo badanie to pozwala na rozpoznanie innych często towarzyszących patologii w stawie biodrowym, takich jak zapalenie kaletki czy ścięgna.
Źródło:
Journal of Ultrasonography; 2016, 16, 66; 296-303
2451-070X
Pojawia się w:
Journal of Ultrasonography
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Biomechanical evaluation of tendon connection with novel suture techniques
Autorzy:
Chen, Z.
Wang, J.
Wei, J.- S.
Hou, Z.-Y.
Li, M.
Chen, Q.-X
Powiązania:
https://bibliotekanauki.pl/articles/306902.pdf
Data publikacji:
2018
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
ścięgno Achillesa
IFLL
biomechanika
internal fixation with limited loop
Achilles tendon
biomechanics
Opis:
Achilles tendon rupture is a severe injury with poor curative effect due to its anatomical characteristic and mechanical peculiarity. Internal fixation of limited loop (IFLL) with steel-wire has been applied on patients with tendon rupture to fix the broken ends before physical rehabilitation. The purpose of this study is to investigate the biomechanical property and radiological characteristic of such suture technique for the repairment of tendon rupture. Methods: Tendons of pigs’ hint feet were separated for the biomechanical study. Suture surgery was performed according to the protocol of IFLL. Biomechanical Testing Machine was adopted to conduct the biomechanical tensile load examination. The maximal load, elastic modulus and tendon stiffness of the stitched tendons with or without reinforcement were examined. Results: The maximum tensile load of the stitched tendons using IFLL reached 1/4 of the uninjured tendon’s maximum tensile load, indicating that such suture technique is capable of providing enough tension for the ruptured tendon. Surprisingly, tendons fixed with titanium wire showed the highest load tension, which was comparable to the undamaged tendon. Therefore, we found the biomechanical basis of using IFLL in effectively connecting the rupture ends of tendons. Conclusions: In conclusion, we provide biomechanical evidence for the use of IFLL in treatment of Achilles tendon rupture, by providing enough strength for the ankle function. Such suture technique could help the patients with better rehabilitation and reduced in-hospital stay after Achilles tendon injury.
Źródło:
Acta of Bioengineering and Biomechanics; 2018, 20, 1; 135-141
1509-409X
2450-6303
Pojawia się w:
Acta of Bioengineering and Biomechanics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Badanie histerezy mechanicznej ścięgien wieprzowych
Mechanical hysteresis tests for porcine tendons
Autorzy:
Liber-Kneć, A.
Łagan, S.
Powiązania:
https://bibliotekanauki.pl/articles/285926.pdf
Data publikacji:
2017
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie. Polskie Towarzystwo Biominerałów
Tematy:
histereza mechaniczna
ścięgno wieprzowe
energia dyssypacji
lepkosprężystość
mechanical hysteresis
porcine tendon
energy of dissipation
viscoelasticity
Opis:
Ścięgna mogą być czasowo lub trwale uszkodzone w warunkach nadmiernego obciążenia lub obciążenia przyłożonego z dużą szybkością. Z punktu widzenia decyzji chirurga istotnym jest przewidywanie intensywności uszkodzeń ścięgien. Można to zrobić poprzez określenie i zrozumienie odpowiedzi mechanicznej i rodzajów uszkodzeń ścięgien pod wpływem działania obciążenia. Jedną z ważnych cech ścięgien jest histereza mechaniczna, która określa zdolność ścięgna do rozpraszania energii, co oznacza, że napięcie mięśni nie jest w pełni przenoszone na szkielet. Badania przeprowadzono w celu określenia histerezy mechanicznej w modelu ścięgien wieprzowych w warunkach cyklicznego obciążenia w próbie quasi-statycznego rozciągania. Wykonano dziesięć cykli obciążenia- -odciążenia w teście quasi-statycznego rozciągania dla trzech poziomów maksymalnego obciążenia: 50 N, 100 N i 150 N. Dla każdego poziomu obciążenia zarejestrowano trzy pętle histerezy (pierwszą, piątą, dziesiątą) i na ich podstawie obliczono wartości energii dyssypacji i histerezy mechanicznej. Średnie wartości energii rozpraszania wyniosły 4,4 ±0,7 mJ, 19,7 ±3,7 mJ, 23,9 ±3,9 mJ odpowiednio dla poziomów obciążenia 50, 100 i 150 N. Między piątym a dziesiątym cyklem, dla których zaobserwowano stabilizację energii rozproszonej, wartości te wynosiły od 22 do 32%, co stanowiło połowę wartości histerezy dla pierwszego cyklu. Zaobserwowano wpływ zastosowanych obciążeń na wartości, zarówno energii dyssypacji, jak i energii zwróconej. Wpływu tego nie zaobserwowano na wartość histerezy mechanicznej.
Tendons may be temporarily or permanently damaged under conditions of excessive high-rate loading. It is important for surgery decisions to predict the intensity of tendons injures. It can be done by the determination and understanding of the mechanical response and the failure modes of tendons under loading. One of the important issues concerned with tendons is mechanical hysteresis, demonstrating the ability of the tendon to dissipate energy, which indicates that the muscular tension is not fully transmitted to the skeleton. The aim of the study was to determine mechanical hysteresis of porcine tendons model under cyclic loading in the quasi-static tensile test. Repeated ten loading-unloading cycles in the quasi-linear tensile test were made for three levels of the maximal load: 50 N, 100 N and 150 N. Three hysteresis loops for each level of load were registered (1st, 5th, 10th) and used for calculation the values of energy dissipation and mechanical hysteresis. The mean values of energy dissipation were 4.4 ±0.7 mJ, 19.7 ±3.7 mJ, 23.9 ±3.9 mJ for load levels 50, 100 and 150 N, respectively. Between fifth and tenth cycle for which the stabilization of the mechanical hysteresis was observed, its values were between 22 and 32%, what was about half of the hysteresis value for the first cycle. The influence of the applied loads on the values of both the energy of dissipation and the returned energy can be seen but the value of mechanical hysteresis is independent of load levels.
Źródło:
Engineering of Biomaterials; 2017, 20, 139; 26-30
1429-7248
Pojawia się w:
Engineering of Biomaterials
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Severe insertional Achilles tendinopathy. Our experience with two different surgical techniques: surgical debridement and dorsal closing wedge calcaneal osteotomy according to modified Zadek’s technique
Zaawansowane zwyrodnienie/tendinopatia przyczepu ścięgna Achillesa. Porównanie wyników leczenia operacyjnego dwoma metodami: chirurgicznego usunięcia zwyrodniałej tkanki oraz osteotomii kości piętowej wg zmodyfikowanej techniki Zadeka
Autorzy:
Kucharski, Robert Adam
Abiddin, Zain
Ahmad, Kashif
Munoruth, Ashveen
Maheshwari, Rajan
Powiązania:
https://bibliotekanauki.pl/articles/2191569.pdf
Data publikacji:
2022-12-30
Wydawca:
Wydawnictwo Exemplum
Tematy:
insertional Achilles tendinopathy
Haglund deformity
calcaneal osteotomy
Zadek osteotomy
ścięgno Achillesa
tendinopatia
osteotomia kości piętowej
osteotomia Zadeka
Opis:
Introduction. This study is a retrospective analysis of two cohorts of patients treated for severe insertional Achilles tendinopathy (IAT) with two different surgical methods: surgical debridement and dorsal closing wedge calcaneal osteotomy according to modified Zadek’s technique. Materials and methods. We treated a total of 36 feet in 35 patients. Twenty five patients had surgical excision of intra-tendinous calcification with excision of posterior calcaneal prominence and reinforcement of insertion with either suture anchors or fibre tape. Ten patients (11 feet) had modified Zadek’s calcaneal osteotomy as an isolated intervention, without any other procedure to the Achilles tendon insertion or to the posterior part of the calcaneus. The mean age at operation was 52.6 years. (Range: 31 to 68 years in the debridement group and 18 to 64 years in the osteotomy group). There were 17 males and 18 females. 20 were right-sided procedures. Mean follow-up in the outpatient clinic for a clinical examination was 20 weeks. We expanded observation period with an up-to-date score based on Victoria Institute of Sport Assessment-Achilles Tendon (VISA-A) questionnaire and Manchester Oxford Foot Questionnaire (MOXFQ) making the maximum follow up in the debridement group up to 8 years and the osteotomy group of 4 years. Results. The open debridement group showed 76% (19 patients) to have a good to excellent outcome. The calcaneal osteotomy group showed 82% (9 patients) to have a good to excellent outcome. Osteotomies were united in all patients. We had no complications in either group until discharge. Conclusions. Both methods showed to be safe and efficient in bringing symptomatic relief to patients in short, medium and long-term observation.
Wstęp. Praca jest retrospektywną analizą dwóch grup chorych leczonych z powodu zaawansowanego zwyrodnienia/tendinopatii ścięgna Achillesa (Insertional Achilles Tendinopathy – IAT) dwoma różnymi technikami: chirurgicznym (debridement) oraz osteotomią kości piętowej z wycięciem zamkniętego klina od strony grzbietowej wg zmodyfikowanej techniki Zadeka. Materiał i metody. Leczono otwartą techniką 36 stóp u 35 chorych, w tym 17 mężczyzn i 18 kobiet. U 20 z nich operowano jedną stopę. U dwudziestu pięciu usunięto zwapnienia z przyczepu ścięgna, wycięto wystającą tylną część kości piętowej, wzmocniono przyczep szwem z kotwicami lub taśmą z włókniny. U 10 chorych 911 stóp wykonano zmodyfikowana osteotomię klinową kości piętowej wg Zadek’a jako izolowaną procedurę bez jakichkolwiek działań w obrębie przyczepu ścięgna Achillesa lub tylnej części kości piętowej. Średnia wieku dla obu grup w chwili operacji wynosiła 52,6 lat. W grupie z debridement wiek wahał się od 31 do 68 lat. W grupie z osteotomią od 18 doo 64 lat. Średnia czasu obserwacji wynosiła 20 tygodni. Obserwację wydłużono i zaktualizowano wykonując w obu grupach ocenę punktową opartą na Victoria Institute of Sport Assessment-Achilles Tendon (VISA-A) Questionnaire i Manchester Oxford Foot Questionnaire (MOXFQ). W grupie z debridement najdłuższej oceny dokonano 8 lat po operacji, a w grupie z osteotomią 4 lata po operacji. Wyniki. W grupie z debridement u 19 chorych (76%) uzyskano dobry lub bardzo dobry wynik leczenia. W grupie leczonych osteotomią kości piętowej u 9 chorych (82%) uzyskano identyczny wynik. U wszystkich chorych uzyskano zrost miejsca osteotomii. Nie obserwowano powikłań w obu grupach. Wnioski. Obie stosowane metody były bezpieczne i dały poprawę również w dłuższym okresie obserwacji.
Źródło:
Chirurgia Narządów Ruchu i Ortopedia Polska; 2022, 87, 4; 148-152
0009-479X
2956-4719
Pojawia się w:
Chirurgia Narządów Ruchu i Ortopedia Polska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wpływ wibracji na parametry stabilograficzne postawy stojącej aplikowanej w dwóch miejscach
Influence of the vibration on stabilographic parameters applied on the two points of the body
Autorzy:
Mańkowski, R.
Słoma, S.
Powiązania:
https://bibliotekanauki.pl/articles/98811.pdf
Data publikacji:
2009
Wydawca:
Politechnika Śląska. Katedra Biomechatroniki
Tematy:
postawa pionowa
wibracja punktowa
mięśnie szyi
ścięgno Achillesa
parametry stabilograficzne
upright postural
local vibration
neck muscles
Achilles tendon
stabilography parameters
Opis:
Celem pracy było określenie wpływu zakłócenia mechanicznego proprioceptorów, w postaci przyłożonej punktowo wibracji, na parametry stabilograficzne postawy stojącej. Wibracja punktowa aplikowana była na ścięgnach Achillesa i na mięśniach karku. W badaniach wzięło udział 11 osób, które wykonywały pięć kolejno następujących po sobie zadań. Wnioski: nie zaobserwowano statystycznych różnic w odległości przemieszczenia ogólnego środka ciężkości w próbach, aplikowania wibracji na ścięgnach Achillesa i mięśniach karku. Zaobserwowano jednak tendencję zmniejszania się wychylenia w przód.
The aim of studies was to definite an influence of mechanical disruption on stabilographic parameters. Point vibration was applied on Achilles tendons and posterior neck muscles. Eleven students have been participated in the experiment. Everyone examined person did 5 static tasks: upright position, forward body sway, upright position, backward body sway and upright position). Those tasks were preceded by 2 freestanding tasks (60 sec each). Conclusion: There were no statistic differences in a freestanding position and a forward body sway. In research has been noticed the decreasing tendency of forward body sway with every next task.
Źródło:
Aktualne Problemy Biomechaniki; 2009, 3; 149-154
1898-763X
Pojawia się w:
Aktualne Problemy Biomechaniki
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The use of digital image correlation in the study of Achilles tendon strain field
Zastosowanie cyfrowej korelacji obrazów w badaniach pola odkształceń ścięgna Achillesa
Autorzy:
Holak, K.
Kohut, P.
Młyniec, A.
Ekiert, M.
Tomaszewski, K.
Uhl, T.
Powiązania:
https://bibliotekanauki.pl/articles/369079.pdf
Data publikacji:
2015
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie. Wydawnictwo AGH
Tematy:
vision systems
digital image correlation
biomechanical measurements
human Achilles tendon
systemy wizyjne
cyfrowa korelacja obrazów
pomiary biomechaniczne
ludzkie ścięgno Achillesa
Opis:
This paper presents an application of a vision-based measurement method in the experimental mechanics of biological materials. The displacement and strain fields of a human Achilles tendon specimen under a tensile test were computed using the digital image correlation method. Different software applications, both commercial and open source, were compared. The performance of algorithms was tested based on a referential measurement earned out by commercial software with the affine model of deformation implemented. The root mean square error of the difference between strain obtained using the reference measurement and each of the analyzed programs was computed. Additionally, an example of a full-field computation of displacement and strain field was presented.
Artykuł przedstawia zastosowanie pomiarów wizyjnych w mechanice eksperymentalnej badającej właściwości materiałów biologicznych. Pole przemieszczeń i odkształceń ludzkiego ścięgna Achillesa uzyskane podczas statycznej próby rozciągania zostało wyznaczone za pomocą algorytmu cyfrowej korelacji obrazów. Porównano kilka wybranych programów komputerowych, zarówno komercyjnych, jak i darmowych, realizujących pomiar za pomocą metody korelacji Skuteczność algorytmów była testowana na podstawie wyników referencyjnych, otrzymanych z komercyjnego programu, w którym została zaimplementowana korelacja oparta na deformowalnym modelu afinicznym. Wyznaczono błędy średniokwadratowe różnicy pomiędzy danymi referencyjnymi a danymi otrzymanymi z każdego z testowanych programów. Dodatkowo pokazano przykład uzyskanego pola przemieszczeń i odkształceń na całej powierzchni testowanej próbki.
Źródło:
Mechanics and Control; 2015, 34, 1; 19-26
2083-6759
2300-7079
Pojawia się w:
Mechanics and Control
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Knitted silk mesh-like scaffold incorporated with sponge-like regenerated silk fibroin/collagen I and seeded with mesenchymal stem cells for repairing Achilles tendon in rabbits
Autorzy:
Tang, L.
Yang, Y.
Li, Y.
Yang, G.
Luo, T.
Xue, Y.
Zhang, W.
Powiązania:
https://bibliotekanauki.pl/articles/306523.pdf
Data publikacji:
2018
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
ścięgno Achillesa
kolagen
komórki macierzyste
szpik kostny
Bombyx mori silk
regenerated silk fibroin
collagen I
bone marrow-derived mesenchymal stem cells
weft-knit
Achilles tendon action
Opis:
A scaffold knit with natural sericin-free silk fibroin fiber possesses desirable mechanical properties, biocompatibility, ease of fabrication, and slow degradability. However, regenerated silk fibroin degrades faster than natural silk. In this study, natural silk fibroin fiber mesh-like scaffolds were prepared by a weft-knitting method and the pores were filled with sponge-like regenerated silk fibroin-collagen I. The microporous sponge and mesh-like scaffolds were fused to achieve gradient degradation of the scaffolds, and rabbit bone marrow mesenchymal stem cells (BMSCs) were seeded onto the scaffolds to form scaffold–BMSCs composites. The composites were implanted into gap defects made in the rabbit Achilles tendon. Twenty weeks after implantation, histological observation showed that tendon-like tissue had formed, collagen I mRNA was expressed, abundant collagen was generated, and that there was no obvious degradation of silk. The maximum load of the neo-Achilles tendon was 62.14% that of the natural Achilles tendon. These outcomes were superior to those obtained in the group implanted with a scaffold without BMSCs. These findings suggest the feasibility of constructing tissue-engineered tendons using weft-knitted silk scaffolds incorporated with sponge-like regenerated silk fibroin/collagen I and seeded with BMSCs, and show potential of the scaffold–BMSCs composites to repair Achilles tendon defects.
Źródło:
Acta of Bioengineering and Biomechanics; 2018, 20, 3; 77-87
1509-409X
2450-6303
Pojawia się w:
Acta of Bioengineering and Biomechanics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Zastosowanie ultrasonografii w diagnostyce bólu bocznego przedziału stawu łokciowego i bliższego końca przedramienia
Ultrasonographic diagnostics of pain in the lateral cubital compartment and proximal forearm
Autorzy:
Dębek, Anna
Nowicki, Paweł
Czyrny, Zbigniew
Powiązania:
https://bibliotekanauki.pl/articles/1061647.pdf
Data publikacji:
2012
Wydawca:
Medical Communications
Tematy:
common extensor tendon
deep branch of the radial nerve
lateral collateral ligament complex
radial tunnel syndrome
tennis elbow
gałązka głęboka nerwu promieniowego
kompleks więzadła pobocznego bocznego
zespół kanału nerwu promieniowego
łokieć tenisisty
ścięgno wspólne prostowników
Opis:
Pain in the lateral compartment of the elbow joint and decreased strength of the extensor muscle constitute a fairly common clinical problem. These symptoms, occurring in such movements as inverting and converting the forearm, pushing, lifting and pulling, mostly affect people who carry out daily activities with an intense use of wrist, e.g. work on computer. Strains in this area often result from persistent overload and degeneration processes of the common extensor tendon and the radial collateral ligament. Similar symptoms resulting from the compression of deep branch of the radial nerve in radial nerve tunnel should be remembered as well. It happens that both conditions occur simultaneously. A proper diagnosis is essential in undertaking an effective treatment. Ultrasonography is a non-invasive method and the application of high-end apparatus with heads of frequencies exceeding 12 MHz allows for a precise evaluation of joint structures, tendons and nerves. In case of the so-called tennis elbow, the examination allows for evaluation of the degree and extent of injury to the radial collateral ligament and common extensor tendon, in addition to the presence of blood vessels in inflicted area. Administration of autologous blood platelets concentrate containing growth factors, used in treatment of tennis elbow, is performed under ultrasound image control conditions. This allows for a precise incision of scar whilst keeping a healthy (unaffected) tissue margin to form fine channels enabling the penetration of growth factors. Post-surgery medical check-up allows for the evaluation of treatment effectiveness. In radial nerve tunnel syndrome, the ultrasound examination can reveal abnormalities in the deep branch of the radial nerve and within the anatomical structures adjacent to the nerve in the radial nerve tunnel. Furthermore, the ultrasound examination allows for detection of other articular and extraarticular pathologies, which affect the compression of the deep branch of radial nerve, such as skeletal deformations, post-traumatic changes, arthritis, and the presence of tumors. The ultrasonography is also helpful in differentiation of symptoms arising from cervical radiculopathy or brachial plexus injury.
Ból bocznego przedziału stawu łokciowego oraz osłabienie siły mięśniowej prostowników są dość powszechnym problemem klinicznym. Objawy te, występujące podczas ruchów odwracania i nawracania przedramienia, pchania, podnoszenia i pociągania dotyczą najczęściej osób, które na co dzień wykonują czynności z aktywnym angażowaniem nadgarstka, na przykład pracując przy komputerze. Dolegliwości w tej okolicy najczęściej powstają w wyniku przewlekłych przeciążeń i procesów degeneracyjnych ścięgna wspólnego prostowników oraz więzadła pobocznego promieniowego. Należy pamiętać o podobnych objawach wynikających z ucisku gałęzi głębokiej nerwu promieniowego w kanale nerwu promieniowego. Zdarza się, że obydwa schorzenia występują jednocześnie. Właściwa diagnoza stanowi podstawę skutecznego leczenia. Badanie ultrasonograficzne jest nieinwazyjną metodą obrazowania, a zastosowanie wysokiej klasy aparatu z głowicami o częstotliwościach powyżej 12 MHz pozwala na precyzyjną ocenę struktur stawowych, ścięgien i nerwów. W przypadku tzw. łokcia tenisisty badanie umożliwia ocenę stopnia i rozległości uszkodzenia więzadła pobocznego promieniowego i ścięgna wspólnego prostowników, a także obecności naczyń w obszarach uszkodzenia. Stosowane w leczeniu łokcia tenisisty podawanie koncentratu płytek autologicznej krwi zawierającej czynniki wzrostu wykonuje się pod kontrolą obrazu ultrasonograficznego. Dzięki temu możliwe jest precyzyjne nakłucie blizny z marginesem zdrowych tkanek, aby wytworzyć drobne kanaliki, które umożliwią penetrację czynników wzrostowych. Kontrolne badania po zabiegu pozwalają na ocenę skuteczności leczenia. W przypadku zespołu kanału nerwu promieniowego badanie ultrasonograficzne umożliwia wykrycie nieprawidłowości w gałęzi głębokiej nerwu promieniowego oraz w obrębie struktur anatomicznych graniczących z nerwem w kanale nerwu promieniowego. Badanie umożliwia wykrycie innych patologii stawowych i pozastawowych, które mają wpływ na ucisk gałęzi głębokiej nerwu promieniowego, takich jak deformacje kostne, zmiany pourazowe, zapalenie stawu oraz obecność guzów. Badanie pomaga także w różnicowaniu dolegliwości wynikających z radikulopatii szyjnej i uszkodzenia splotu barkowego.
Źródło:
Journal of Ultrasonography; 2012, 12, 49; 188-201
2451-070X
Pojawia się w:
Journal of Ultrasonography
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-11 z 11

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies