Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "Zubrzycki, J." wg kryterium: Autor


Wyświetlanie 1-11 z 11
Tytuł:
Computer Aided Design and Structural Analysis of the Endoprosthesis of the Knee Joint
Autorzy:
Zubrzycki, J.
Karpiński, R.
Górniak, B.
Powiązania:
https://bibliotekanauki.pl/articles/118225.pdf
Data publikacji:
2016
Wydawca:
Polskie Towarzystwo Promocji Wiedzy
Tematy:
knee joint
endoprosthesis
finite elements analysis
Opis:
The paper presents results of the preliminary structural analysis of model of the endoprosthesis of the knee joint. Basics of anatomy and biomechanics of the knee joint were introduced. Based on data from computed tomography, the model of knee joint was constructed. The prototype of the endoprosthesis of the knee joint was designed. After determining physical properties of structural materials, the Finite Elements Analysis of the model was conducted under various load conditions. Finally the results of analysis are presented.
Źródło:
Applied Computer Science; 2016, 12, 2; 84-95
1895-3735
Pojawia się w:
Applied Computer Science
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Zastosowanie technologii rapid prototyping do projektowania elementów maszyn
Autorzy:
Pieniak, D.
Zubrzycki, J.
Wojciechowski, Ł.
Powiązania:
https://bibliotekanauki.pl/articles/118518.pdf
Data publikacji:
2016
Wydawca:
Politechnika Koszalińska. Wydawnictwo Uczelniane
Tematy:
Rapid Prototyping
modelowanie 3D
drukowanie 3D
FDM
3D modeling
3D printing
Opis:
Technologie Rapid Prototyping (RP) obejmują wiele metod szybkiego wytwarzania modeli fizycznych – prototypów lub części maszyn – z pominięciem tradycyjnych technologii wytwarzania. Odlewanie, obróbka ubytkowa czy elektroerozyjna zastępowane są zaawansowanymi technikami RP. Obiekty rzeczywiste uzyskane za pomocą technologii Rapid Prototyping znajdują zastosowanie podczas prezentacji wyrobów potencjalnym inwestorom, w badaniach opinii klienta, analizie gotowego wyrobu, a także mogą być w pełni funkcjonalnymi przedmiotami.
The purpose of the article is to discuss Rapid Prototyping techniques in machine parts designing. The article presents the authorial RP process of industrial robots gripping elements designing. First of all, the idea of Rapid Prototyping and typical RP techniques are described. Moreover, the designing process, the strength analysis and modeled parts printing process were outlined. In the final part of the paper the authors discussed the results of works.
Źródło:
Zeszyty Naukowe Wydziału Elektroniki i Informatyki Politechniki Koszalińskiej; 2016, 10; 61-79
1897-7421
Pojawia się w:
Zeszyty Naukowe Wydziału Elektroniki i Informatyki Politechniki Koszalińskiej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Structural analysis of articular cartilage of the hip joint using finite element method
Autorzy:
Karpiński, R.
Jaworski, Ł.
Zubrzycki, J.
Powiązania:
https://bibliotekanauki.pl/articles/102504.pdf
Data publikacji:
2016
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
hip joint
pelvis
femur
cartilage
finite element method
Opis:
The paper presents the results of a preliminary study on the structural analysis of the hip joint, taking into account changes in the mechanical properties of the articular cartilage of the joint. Studies have been made due to the need to determine the tension distribution occurring in the cartilage of the human hip. These distribution are the starting point for designing custom made human hip prosthesis. Basic anatomy, biomechanical analysis of the hip joint and articular cartilage are introduced. The mechanical analysis of the hip joint model is conducted. Final results of analysis are presented. Main conclusions of the study are: the capability of absorbing loads by articular cartilage of the hip joint is preliminary determined as decreasing with increasing degenerations of the cartilage and with age of a patient. Without further information on changes of cartilage’s mechanical parameters in time it is hard to determine the nature of relation between mentioned capability and these parameters.
Źródło:
Advances in Science and Technology. Research Journal; 2016, 10, 31; 240-246
2299-8624
Pojawia się w:
Advances in Science and Technology. Research Journal
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Zastosowanie metod inżynierii odwrotnej do projektowania sztucznego krążka międzykręgowego
The impact of the artificial intervertebral disc on functioning the lumbar spine
Autorzy:
Mańko, M.
Zubrzycki, J.
Karpiński, R.
Powiązania:
https://bibliotekanauki.pl/articles/101816.pdf
Data publikacji:
2015
Wydawca:
Politechnika Lubelska. Polskie Towarzystwo Promocji Wiedzy
Tematy:
kręg lędźwiowy
sztuczny krążek międzykręgowy
biomechanika
lumbar vertebra
artificial intervertebral disc
biomechanics
Opis:
W pracy przedstawiono budowę anatomiczną kręgu i krążka międzykręgowego. Opisano funkcjonowanie kręgosłupa, jego kinematykę oraz oddziaływania międzykręgowe. Stworzono pełny trójwymiarowy model kręgów lędźwiowych L2 – L4. Na ich podstawie skonstruowano model endoprotezy krążka międzykręgowego (pomiędzy L2 i L3). Opracowano uproszczony model sztucznego krążka międzykręgowego sformułowany metodą elementów skończonych, który posłużył do analizy biomechanicznej. Dokonano obliczeń wytrzymałościowych oraz wyciągnięto odpowiednie wnioski. Prezentowane wyniki przedstawiają zachowanie się trójwymiarowego modelu kręgu lędźwiowego przy zastosowaniu endoprotezy krążka międzykręgowego pod wpływem działania obciążeń.
In the hereby thesis the anatomy of the lumbar vertebra and intervertebral disc were presented. Functioning and kinematics of the spine and intervertebral forces were described.Full three – dimensional model of the lumbar vertebrae L2 – L4 was created. On the basis of it model of artificial intervertebral disc was constructed (between L2 and L3). The simplified model of vertebra L2 was formulated via finite elements method. Processed model has been used for biomechanical analysis.Strength calculations were made and appropriate conclusions were drawn. Presented results show behavior influenced of three – dimensional model of the lumbar vertebra with artificial intervertebral disc by operation of loads.
Źródło:
Journal of Technology and Exploitation in Mechanical Engineering; 2015, 1, 1-2; 33-58
2451-148X
Pojawia się w:
Journal of Technology and Exploitation in Mechanical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Numerical Analysis of Spinal Loads in Spondylolisthesis Treatment using Pedicle Screws – Preliminary Research
Autorzy:
Zubrzycki, J.
Smidova, N.
Litak, J.
Ausiyevich, A.
Powiązania:
https://bibliotekanauki.pl/articles/117950.pdf
Data publikacji:
2017
Wydawca:
Polskie Towarzystwo Promocji Wiedzy
Tematy:
pedicle screws
FEA
CAD
3D modeling
Opis:
The aim of this experimental study was to analyse the influence of lumbar stabilisation used in the treatment of spondylolisthesis on the biomechanical properties of the human lumbar spine. FEM models were built on the basis of pre-surgical CT scans, routinely used in medical practice. MIMICS software was used to process the results of the neuroimaging study and to create 3D models. Two models were built: with and without a stabiliser. A static load analysis was performed for a normal upper-body load. The simulations allowed to determine the stresses in the individual discs for both models, with and without the transpedicular stabiliser.
Źródło:
Applied Computer Science; 2017, 13, 3; 64-76
1895-3735
Pojawia się w:
Applied Computer Science
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Broadband concept of energy harvesting in beam vibrating systems for powering sensors
Autorzy:
Rysak, A
Müller, M.
Borowiec, M.
Zubrzycki, J.
Litak, G.
Godlewska-Lach, A
Wittstock, V.
Powiązania:
https://bibliotekanauki.pl/articles/957989.pdf
Data publikacji:
2014
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
piezoceramic
energy harvesting
vibration
broadband effect
impacts
Opis:
Recent demand for powering small sensors for wireless health monitoring triggered activities in the field of small size efficient energy harvesting devices. We examine energy harvesting in an aluminium beam with a piezoceramic patch subjected to kinematic harmonic excitation and impacts. Due to a mechanical stopper applied, inducing a hardening effect in the spring characteristic of the beam resonator, we observed a broader frequency range for the fairly large power output. Impact nonlinearities caused sensitivity to initial conditions and appearance of multiple solutions. The occurrence of resonant solution associated with impacts increased efficiency of the energy harvesting process.
Źródło:
Advances in Science and Technology. Research Journal; 2014, 8, 23; 62-67
2299-8624
Pojawia się w:
Advances in Science and Technology. Research Journal
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Working parameters of the electron - beam-generated ion source for ISOL facilities
Autorzy:
Yushkevich, Y. V.
Turek, M.
Mączka, D.
Pyszniak, K.
Słowiński, B.
Vaganov, Y. A.
Zubrzycki, J.
Powiązania:
https://bibliotekanauki.pl/articles/146648.pdf
Data publikacji:
2012
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
on-line isotope separation
short-lived nuclides
nuclear spectroscopy
ion sources
Opis:
An electron-beam generated plasma (EBGP) ion source for nuclear spectroscopy purposes at YASNAPP (YAdernaya Spektroskopya NA Putchkah Protonov - nuclear spectroscopy using proton beams) isotope separation on-line facility is presented. Working conditions both in on- and off-line mode are presented and discussed. Formation of a potential trap inside a discharge chamber is an advantage of the presented construction, enabling relatively high ionization efficiencies (2-5%) even for hard-to-ionize elements like Be, Ti, V, Zr, Nb, Mo, Tc, Ru, Rd, Hf, Ta, W, Re, Os, Ir, Pt. The paper presents estimation of critical values of working parameters that enable formation of the ion trap leading in consequence to high efficiency of ionization. The optimal temperature of the discharge chamber and cathode walls is found to be in the range 2600-2800 K. Calculations of the output rates of ions produced in the on-line mode are also presented as well as the constraints on the half-life time of obtained nuclides imposed by construction details like the target material and its thickness.
Źródło:
Nukleonika; 2012, 57, 3; 351-356
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Altered tissue electrical properties in women with breast cancer – Preliminary observations.
Autorzy:
Malecka-Massalska, T.
Chara, K.
Golebiowski, P.
Wladysiuk, M.
Smolen, A.
Kurylcio, A.
Zuchora, B.
Zubrzycki, J.
Orlowska-Kowalik, G.
Lupa-Zatwarnicka, K.
Polkowski, W.
Powiązania:
https://bibliotekanauki.pl/articles/51083.pdf
Data publikacji:
2013
Wydawca:
Instytut Medycyny Wsi
Opis:
Introduction and objectives: In the United States, breast cancer (BC) is the most common non-skin cancer. In Poland, it is estimated that the number of new breast cancer cases affects about 13,500 women each year. There are many methods for nutritional status assessment. One of them is bioimpedance analysis (BIA). Direct bioimpedance measures (resistance, reactance, phase angle (PA)) determined by bioelectrical impedance analysis (BIA) detectf changes in tissue electrical properties. The study was conducted to investigate whether there are any tissue electrical differences in patients with breast cancer. Materials and methods: The direct bioimpedance measures determined by bioelectrical impedance analysis (BIA) were performed on 34 patients with BC and 34 healthy volunteers. The measurements were made with ImpediMed bioimpedance analysis SFB7 BioImp v1.55 (Pinkenba Qld 4008, Australia). Results: Reactance and resistance at 50 kHz was found to be significantly greater in patients with BC than in the control group (53.59° ± 1.53 vs. 47.26° ± 1.25, respectively, p=0.0031; 603.24° ± 15.38 ohm vs. 515.87° ± 11.48 ohm, respectively, p=0.00004). Conclusion: Pre-surgical patients diagnosed with BC have altered tissue electrical properties. Further observations of a larger patient group would be valuable to calculate survival, validate the prognostic significance of PA, and monitor nutritional and therapeutic interventions in this patient population.
Źródło:
Annals of Agricultural and Environmental Medicine; 2013, 20, 3
1232-1966
Pojawia się w:
Annals of Agricultural and Environmental Medicine
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Zmiany chropowatości tarcz hamulcowych motocykla klasy E2 w zależności od warunków użytkowania
Changes roughness brake discs motorcycle class E2 depending on the conditions of use
Autorzy:
Bil, T.
Chomka, G.
Chudy, J.
Zubrzycki, K.
Powiązania:
https://bibliotekanauki.pl/articles/310202.pdf
Data publikacji:
2016
Wydawca:
Instytut Naukowo-Wydawniczy "SPATIUM"
Tematy:
motocykl
tarcze hamulcowe
chropowatość
zużycie ścierne
motorbike
brake discs
roughness
Opis:
W artykule przedstawiono wyniki badań dotyczących oceny zużycia ściernego tarcz hamulcowych motocykla Enduro klasy E2 marki KTM EXC 200. Badania przeprowadzono w warunkach suchych na podłożu piaszczystym i asfaltowym oraz w warunkach błotnistych.
The article presents the results of research on the evaluation of wear of brake discs motorcycle Enduro class E2 brand KTM EXC 200. Tests were carried out in dry conditions on sand and bitumen and in wet conditions on the muddy surface.
Źródło:
Autobusy : technika, eksploatacja, systemy transportowe; 2016, 17, 8; 58-61
1509-5878
2450-7725
Pojawia się w:
Autobusy : technika, eksploatacja, systemy transportowe
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-11 z 11

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies