Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "Zajusz-Zubek, E." wg kryterium: Autor


Wyświetlanie 1-4 z 4
Tytuł:
Coal Cleaning Versus the Reduction of Mercury and other Trace Elements’ Emissions from Coal Combustion Processes
Autorzy:
Zajusz-Zubek, E.
Konieczyński, J.
Powiązania:
https://bibliotekanauki.pl/articles/204840.pdf
Data publikacji:
2014
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
heavy metals
steam coals
coal wet cleaning
densimetric fractions
mercury emission reduction
metale ciężkie
spalanie węgla
proces czyszczenia węgla
redukcja emisji rtęci
Opis:
Samples of steam coal used in heat and power plants as well as densimetric fractions obtained on a laboratory scale by dense organic liquid separation have been examined. The contents of ash, mercury, chromium, cadmium, copper, nickel and lead have been determined in coal, in the light and medium fraction as well as in the refuse. The degree of removal of mineral matter and the examined heavy metals as well as the coal combustible parts yield have been determined. Examination of 5 coals revealed that it is possible to remove 41% of mercury and more than 35% of other heavy metals bound to mineral matter in coal.
Źródło:
Archives of Environmental Protection; 2014, 40, 1; 115-127
2083-4772
2083-4810
Pojawia się w:
Archives of Environmental Protection
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Determination on carbon dioxide levels in school buildings: the effect of thermal efficiency improvement
Badanie stężeń ditlenku węgla w pomieszczeniach szkolnych z uwzględnieniem wpływu termomodernizacji budynku
Autorzy:
Mainka, A.
Zajusz-Zubek, E.
Powiązania:
https://bibliotekanauki.pl/articles/297381.pdf
Data publikacji:
2018
Wydawca:
Politechnika Częstochowska. Wydawnictwo Politechniki Częstochowskiej
Tematy:
carbon dioxide
schools
school children’s exposure
thermal modernization
ditlenek węgla
szkoły
narażenie uczniów
termomodernizacja
Opis:
Indoor air quality (IAQ) in schools is an important public health concern. Particular attention should be paid to children, because they are more vulnerable to air pollution than adults. Although carbon dioxide is not considered a toxic air pollutant, its concentrations inside buildings may have a negative impact on users. The most commonly described health problems include tiredness and its effects (headaches, bad mood, poor attentiveness). Carbon dioxide concentrations are often used as a surrogate for the rate of outside supply air per occupant. Permissible concentration of carbon dioxide in confined spaces is 1,000 ppm. This minimum sanitary requirement is recommended by the European Office of the WHO and ASHRAE. The Polish Committee for Standardization has established general guidelines concerning the quality of air inside non-residential buildings. This standard was drawn up based on EU directives, through classification of IAQ, as it is influenced by the CO2 concentrations above the outdoor level (ΔCO2). Based on the above regulations, the increase in indoor CO2 concentrations in relation to CO2 concentrations in outdoor air (CO2) were measured along with physical parameters (temperature and relative humidity) to evaluate IAQ in the classrooms of two primary schools built in the nineteenth century in Poland. More than 100-year-old buildings built of bricks before World War II are a frequent occurrence in rural schools in the area of Upper Silesia, Poland. One of the school buildings underwent thermal effectiveness improvement while the other has not been modernized in these terms yet. The aim of the research was to check the extent to which thermal modernization of an old public building influences indoor air quality in the context of concentrations of carbon dioxide. The measurement period was chosen for late spring in order to avoid the impact of municipal emissions (so-called low emissions) common in rural areas. The average concentration of carbon dioxide in school rooms after thermal modernization (WTM) were higher than the concentrations observed in the school not subjected to thermal modernization (NTM). The CO2 concentrations ranged from 1,287±333 ppm to 2,146±386 ppm and from 936±196 ppm to 1,878±567 ppm in WTM and NTM school buildings, respectively. The results clearly indicate a higher occurrence of poor air quality (up to 70% of time during the school days) in the thermally improved school building compared to the one without thermal improvement (up to 52% of the time). The measurements also showed that the exposure of school children to elevated carbon dioxide concentrations during classes was higher in thermally improved primary school buildings, which in turn may represent a health concern.
Pomimo iż ditlenek węgla nie jest uważany za trujące zanieczyszczenie powietrza, poziomy jego stężeń wewnątrz budynków mogą skutkować negatywnym wpływem na użytkowników danych pomieszczeń. Wśród najczęściej opisywanych problemów zdrowotnych wymienia się uczucie zmęczenia i jego konsekwencje (bóle głowy, złe samopoczucie, kłopoty z koncentracją). W celu oceny potencjalnych skutków zdrowotnych dokonano pomiarów stężeń ditlenku węgla wraz z parametrami fizycznymi (temperaturą i wilgotnością względną) w pomieszczeniach dwóch szkół podstawowych zbudowanych w XIX wieku. Budynek jednej z nich został poddany termomodernizacji, w drugim jej nie przeprowadzono. Uzyskane wyniki wskazują na częstsze występowanie niskiej jakości powietrza w szkole poddanej termomodernizacji (do 70% czasu w ciągu dnia nauki) w porównaniu do szkoły bez termomodernizacji (do 52% czasu). Przeprowadzone badania wskazują, iż uczniowie budynku szkoły podstawowej poddanego termomodernizacji są częściej narażeni na podwyższone stężenia ditlenku węgla w czasie lekcji aniżeli uczniowie budynku szkoły niepoddanego termomodernizacji, co w konsekwencji może dla nich stanowić zagrożenie zdrowotne.
Źródło:
Inżynieria i Ochrona Środowiska; 2018, 21, 2; 155-162
1505-3695
2391-7253
Pojawia się w:
Inżynieria i Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analiza występowania pierwiastków śladowych w formie mobilnej frakcji respirabilnej pyłu (PM2,5) pobranego w otoczeniu elektrowni węglowej
Analysis of trace elements in the mobile form of respirable fraction PM2.5 collected in the surroundings of power plant
Autorzy:
Zajusz-Zubek, E.
Mainka, A.
Powiązania:
https://bibliotekanauki.pl/articles/297310.pdf
Data publikacji:
2015
Wydawca:
Politechnika Częstochowska. Wydawnictwo Politechniki Częstochowskiej
Tematy:
analiza specjacyjna
PM2,5
metale ciężkie
elektrownia węglowa
zanieczyszczenia powietrza
speciation analysis
heavy metals
power plant
air pollutants
Opis:
W pracy przedstawiono wstępne wyniki badań występowania wybranych pierwiastków śladowych (As, Cd, Co, Cr, Pb, Sb i Se), należących do grupy HAPs (ang. Hazardous Air Pollutants), w formie biodostępnej frakcji respirabilnej (PM2,5). Odpowiednią frakcję pyłu pobrano w otoczeniu pracującej elektrowni węglowej opalanej węglem kamiennym. Analiza specjacyjna frakcji pyłu PM2,5 została przeprowadzona według zmodyfikowanego schematu Tessiera z wykorzystaniem ekstrakcji formy rozpuszczalnej w wodzie (Frakcja 1). Średnie stężenia pierwiastków badanych we frakcji rozpuszczalnej w wodzie utworzyły następujący szereg: Pb>Cr>As>Sb>Cd>Se>Co. Jest on zbliżony do szeregu otrzymanego w źródłach literaturowych.
Research regarding environment and dust exposition conducted so far has been based on theoretical factors. These factors primarily concern the total content of heavy metals in suspended dust. However, there is a shortage of data on the specific chemical forms of trace elements. These forms condition the heavy metal threat on the environment and human health. Based on the results of chemical speciation, we can define the mobility of elements (including heavy metals) in the environment, that is, their bio-chemical activity during assimilation by organisms. The paper presents preliminary results of the occurrence of selected trace elements (As, Cd, Co, Cr, Pb, Sb and Se) that belong to the HAPs group (Hazardous Air Pollutants) in the PM2.5 water soluble form. The appropriate fraction of particulate matter was collected by Dekati PM10 Impactor in the surroundings of a working power plant that is fired with hard coal. The speciation analysis of PM2.5 fraction was conducted using a modified Tessier scheme. This procedure employs the extraction of a water soluble fraction (Fraction 1). The concentrations of elements were determined using the ICPMS technique. Measurements delivered data on the average concentration of respirable fraction PM2.5, which equaled 22.93 μg/m3. While conducting the research in the surroundings of a working power plant, a relatively high ratio of PM2.5 to TSP (83%) and to PM10 (88%) was found. Among the determined trace elements, the highest average total concentration in PM2.5 was found for Pb (82.17 ng/m3), while the lowest (less than 1 ng/m3) was found for Co. The highest average concentration in water soluble fraction F1 in PM2.5 was also found for Pb (12,97 ng/m3), while the lowest concentration (below 1 ng/m3) was found for Sb, Cd, Se and Co. The average concentrations of trace elements determined in the bioavailable fraction were found in a following order: Pb>Cr>As>Sb>Cd>Se>Co. This sequence is similar to the order received in the existing literature. In future, received data will assist in determining the forms of hazardous trace elements in total suspended particles (TSP), suspended dust (PM10) and in respirable fraction (PM2.5) in the surroundings of selected working power plants.
Źródło:
Inżynieria i Ochrona Środowiska; 2015, 18, 2; 245-258
1505-3695
2391-7253
Pojawia się w:
Inżynieria i Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Badanie zanieczyszczeń powietrza oddziałujących na dzieci w przedszkolu miejskim zlokalizowanym przy drodze o dużym natężeniu ruchu
Children exposure to air pollutants in nursery school near a major road in urban area
Autorzy:
Mainka, A.
Zajusz-Zubek, E.
Kozielska, B.
Brągoszewska, E.
Powiązania:
https://bibliotekanauki.pl/articles/297242.pdf
Data publikacji:
2015
Wydawca:
Politechnika Częstochowska. Wydawnictwo Politechniki Częstochowskiej
Tematy:
powietrze wewnętrzne
lotne związki organiczne
pył zawieszony
bioaerozol
dwutlenek węgla
indoor air
children
volatile organic compounds
particulate matter
bioaerosols
carbon dioxide
Opis:
Przedstawiono wyniki pomiarów stężeń lotnych związków organicznych (LZO), pyłu całkowitego (TSP), frakcji PM10, PM2,5 i PM1 oraz bioaerozoli. Wykonywano również pomiary stężenia CO2 jako wskaźnika skuteczności systemu wentylacji. Pomiary przeprowadzono w okresie grzewczym w dwóch salach opiekuńczych (dzieci w wieku 3-6 lat) oraz na zewnątrz budynku przedszkola położonego w centrum Gliwic (Górny Śląsk) przy drodze o dużym natężeniu ruchu. Wyniki badań wskazują na gorsze warunki co do jakości powietrza wewnątrz. Dla sumy 16 LZO stosunki stężeń wewnątrz i na zewnątrz budynku (I/O) w zależności od sali wahały się od 2 do 5, dla pyłu PM10 sięgały 4, a dla PM2,5 wynosiły około 2. W przypadku bioaerozoli grzybowych średni wskaźnik I/O sięgał 2, natomiast dla aerozoli bakteryjnych przekraczał 8. Jednocześnie ciągłe pomiary stężeń CO2 wykazały dominujący udział niskiej jakości powietrza podczas przebywania dzieci w obu salach przedszkola. Wyniki wskazują na niewystarczającą skuteczność systemu wentylacji, co może negatywnie wpływać na zdrowie i samopoczucie dzieci.
Children are particularly sensitive to pollutants. The reason for this is that, according to body weight, they breathe in more air than adults. Moreover, due to rapid growth, their immature immune system is more vulnerable to damage than already mature organisms. Children aged 3 to 6 spend large amounts of time indoors, so there is a necessity to evaluate the quality of air in nursery schools. This study investigated the concentrations of volatile organic compounds (VOCs), particulate matter (TSP, PM10, PM2.5 and PM1) and bioaerosols. The concentration of CO2 was monitored as the indicator of ventilation efficiency. The measurements were performed during winter, in two classrooms and outside the nursery school building located in the centre of Gliwice (Upper Silesia), near a road with high traffic. Outdoor concentrations were lower than those indoors for each inspected classroom. For the sum of 16 VOCs, the I/O ratio, depending on classroom, varied from 2 to 5, PM10 reached 4 and for PM2.5, the ratio was about 2. For fungi bioaerosols, the average I/O ratio was about 2, while for bacteria, aerosols exceeded 8. The evaluation of indoor air quality (IAQ) based on CO2 concentration differed from averaging time. Taking into consideration the 24 hour distribution of CO2 concentration in both classrooms dominated the first category of indoor air quality (WEW1), we can expect that children stayed in the environment with high air quality, however, this was not the case. During children’s nursery school attendance for the duration of the working day and throughout five-hour elementary nursery care, the air inside classrooms was mostly 65 to 72% of poor quality (WEW4). In the case of certain pollutants, significant differences in air quality were found between the classrooms of older (I) and younger (II) children. For fungal bioaerosols, the concentration was twice as high in the classroom of younger children (II) compared to the classroom of older children (I). However, in the case of particulate matter, for all studied fractions (TSP, PM10, PM2.5 and PM1), concentrations were about twice as high in classroom I compared to classroom II. This confirms the important role of particulate matter resuspension in classroom I as a result of the intensive activity of older children. Compared to the classroom of older children (I), in the classroom of younger children (II) there were more absorbent materials; hence, we expected higher concentrations of VOCs associated with secondary sources. However, concentrations of VOCs did not confirm this relationship. In the case of bacterial bioaerosols, no significant differences were observed between the classrooms. Continuous measurements of CO2 concentrations showed that in the classroom of older children (I), the air was negligibly worse than in the classroom of younger children (II); this may have been due to the lower efficiency of the natural ventilation system on the first floor of the investigated building.
Źródło:
Inżynieria i Ochrona Środowiska; 2015, 18, 1; 119-133
1505-3695
2391-7253
Pojawia się w:
Inżynieria i Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-4 z 4

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies