Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "Wychowański, P." wg kryterium: Autor


Wyświetlanie 1-3 z 3
Tytuł:
The release of biologically hazardous chemical compounds from orthodontic adhesive systems used in Europe and in the USA — an in vitro study
Uwalnianie biologicznie szkodliwych związków chemicznych z dostępnych na rynkach Europy i USA ortodontycznych systemów adhezyjnych — badania in vitro
Autorzy:
Małkiewicz, K.
Wychowański, P.
Małkiewicz, E.
Olczak-Kowalczyk, D.
Turło, J.
Powiązania:
https://bibliotekanauki.pl/articles/945851.pdf
Data publikacji:
2015
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Chemii Przemysłowej
Tematy:
orthodontic adhesive systems
monomers release
HPLC
ortodontyczne systemy adhezyjne
uwalnianie monomerów
Opis:
The study assessed the chemical stability of ConTec LC, Resilence, Light Bond and Transbond XT orthodontic adhesive resins. The subject of the analysis was the release of HEMA (2-hydroxyethylmethacrylate), TEGDMA (triethylene glycol dimethacrylate), EGDMA (ethylene glycol dimethacrylate), UDMA (urethane dimethacrylate) and BPA (bisphenol A) monomers from test sample materials in successive time intervals, using HPLC (high pressure liquid chromatography). The study confirmed the presence of methacrylate monomers and bisphenol A in eluates of the assessed materials regardless of the observation period. The results show that orthodontic adhesive systems polymerized with visible light are chemically unstable, releasing biologically harmful ingredients to the external environment for a long time. Dental materials containing polymer network based on methacrylates require structure modification or elimination of harmful components in order to increase safety of their application.
Oceniano stabilność chemiczną ortodontycznych żywic adhezyjnych ConTec LC, Resilence, Light Bond oraz Transbond XT. Metodą wysokociśnieniowej chromatografii cieczowej (HPLC) analizowano uwalnianie z próbek badanych materiałów monomerów: HEMA (metakrylan 2-hydroksyetylu), TEGDMA (dimetakrylan triglikolu etylenowego), EGDMA (dimetakrylan glikolu etylenowego), UDMA (dimetakrylan uretanu) i BPA (bisfenol A) w kolejnych przedziałach czasowych. Badania potwierdziły obecność monomerów metakrylanowych i bisfenolu A w eluatach ocenianych materiałów, niezależnie od czasu obserwacji. Uzyskane wyniki wskazują, że polimeryzowane światłem widzialnym ortodontyczne systemy adhezyjne są niestabilne chemicznie i w ciągu długiego czasu emitują do środowiska zewnętrznego składniki biologicznie szkodliwe. Materiały stomatologiczne zawierające usieciowane metakrylany wymagają modyfikacji struktury lub eliminacji szkodliwych komponentów w celu zwiększenia bezpieczeństwa ich stosowania.
Źródło:
Polimery; 2015, 60, 5; 309-315
0032-2725
Pojawia się w:
Polimery
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Technical and organizational and legal conditions relating to the power supply of a railway vehicle equipped with automatic train control system
Autorzy:
Jacyna, M.
Kukulski, J.
Gołębiowski, P.
Jasiński, S.
Wychowański, W.
Powiązania:
https://bibliotekanauki.pl/articles/245650.pdf
Data publikacji:
2018
Wydawca:
Instytut Techniczny Wojsk Lotniczych
Tematy:
railway transport
automatic train control system
electricity
rmCBTC
power requirements
Opis:
Railway transport is considered the most environmentally friendly. However, taking into account all factors, (including point pollution associated with the production of energy necessary for the movement of electric traction vehicles); this position is attractive, but a little less. Therefore, it is necessary to ensure that the amount of energy produced for railway transport is sufficient, but the lowest as possible. Creating new systems whose components for correct operation require a supply of electricity, they should be designed in such a way as to consume as little energy but meeting a series of standards. The aim of the article is to review selected requirements for the power supply of a railway vehicle equipped with automatic train control devices and identification of energy demand in the scope of supplying the rmCBTC on-board system, which is being developed by Rail-Mil Computers Company from Warsaw and the Faculty of Transport of the Warsaw University of Technology. The article presents an analysis of formal and legal requirements in the field of traction vehicles. Reference was made to the list of the Office of Rail Transport and the standards not included in it − PN-EN 50155, PN-EN 61000-6 and PN-EN 50125-2. Energy requirements in the field of traction vehicles equipped with an automatic train control system have been identified − e.g. voltage range of the on-board system, permissible decays, voltage dips, disturbances and environmental requirements. The energy requirements for the rmCBTC on-board system were also identified.
Źródło:
Journal of KONES; 2018, 25, 4; 533-545
1231-4005
2354-0133
Pojawia się w:
Journal of KONES
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wybrane problemy metrologiczne oceny morfologicznej i funkcjonalnej stopy w leczeniu palucha koślawego
Selected metrological problems of morphological and functional foot assessment
Autorzy:
Wychowański, M.
Nowiński, K.
Borucki, B.
Wit, A.
Adamczyk, P.
Laskowski, J.
Powiązania:
https://bibliotekanauki.pl/articles/156354.pdf
Data publikacji:
2012
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
paluch koślawy
model szkieletu stopy
charakterystyka chodu
wskaźnik symetrii
hallux valgus
foot skeleton model
gait profile
symmetry index
Opis:
Paluch koślawy jest chorobą często występującą u kobiet. Wykonano RTG obu stóp w projekcji AP, bocznej i na palcach oraz MRI. Opracowano, trójwymiarowy model strukturalny szkieletu stopy. Przeanalizowano błędy wyznaczenia położeń poszczególnych znaczników. Zbadano równowagęu zdrowych osób metodą stabilograficzną. Pomiarów charakterystyk chodu dokonano na ścieżce podoskopowej. Względem młodszych kobiet przeprowadzono normowanie wyników starszych kobiet. Parametry charakteryzujące badane kobiety nie mają rozkładu normalnego. Profil chodu kobiet starszych opisano 19 parametrami. Różnice w chodzie obu badanych grup kobiet przejawiają się głównie w parametrach geometrycznych. Normy symetrii kobiet podano dla 1 kwartyla, mediany i 3 kwartyla.
Hallux valgus is one of the most frequent forefoot disease in women. There was taken RTG of both feet in the AP, lateral and tip toe projection as well as MRI. A three-dimensional structural foot skeleton model was developed. There was analysed the uncertainty of landmark positioning together with the influence on foot geometric features. Balance mechanism was examined in healthy subjects using the HUR stabilographic platform. Gait characteristics were made on the pressure distribution plate produced by ZEBRIS. There were separated two groups of younger women and a group of older women. Normalization of older women was carried out in relation to the younger group. The parameters characterizing the investigated women did not have a normal distribution. The gait profile of older women is based on 19 parameters. Differences in gait performance of both groups of women are mainly manifested in the geometric parameters. The norms of the symmetry index for the women are given as 1 quartile, median and 3 quartile.
Źródło:
Pomiary Automatyka Kontrola; 2012, R. 58, nr 1, 1; 48-51
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-3 z 3

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies