Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "Wu, Xingbao" wg kryterium: Autor


Wyświetlanie 1-2 z 2
Tytuł:
Qualitative investigation of nonlinear differential equations describing infiltration of water
Autorzy:
Wu, Xingbao
Powiązania:
https://bibliotekanauki.pl/articles/1311561.pdf
Data publikacji:
1995
Wydawca:
Polska Akademia Nauk. Instytut Matematyczny PAN
Tematy:
water percolation and seepage
similarity solution
nonlinear differential equation
qualitative behavior
Opis:
A nonlinear differential equation of the form (q(x)k(x)u')' = F(x,u,u') arising in models of infiltration of water is considered, together with the corresponding differential equation with a positive parameter λ, (q(x)k(x)u')' = λF(x,u,u'). The theorems about existence, uniqueness, boundedness of solution and its dependence on the parameter are established.
Źródło:
Annales Polonici Mathematici; 1995, 61, 1; 39-57
0066-2216
Pojawia się w:
Annales Polonici Mathematici
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
An improved angle calibration method of a high-precision angle comparator
Autorzy:
Xia, Yangqiu
Wu, Zhilin
Huang, Ming
Liu, Xingbao
Mi, Liang
Tang, Qiang
Powiązania:
https://bibliotekanauki.pl/articles/1848955.pdf
Data publikacji:
2021
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
angle calibration
position error
complete closure method
method verification
Opis:
Angle calibrations are widely used in various fields of science and technology, while in the high-precision angle calibrations, a complete closure method which is complex and time-consuming is common. Therefore, in order to improve the measurement efficiency and maintain the accuracy of the complete closure method, an improved calibration method was proposed and verified by the calibration of a high-precision angle comparator with sub-arc-second level. Firstly, a basic principle and algorithm of angle calibration based on complete closure and symmetry connection theory was studied. Then, depending on the pre-established calibration system, the comparator was respectively calibrated by two calibration methods. Finally, by comparing En values of two calibration results, the effectiveness of the improved method was verified. The calibration results show that the angle comparator has a stable angle position error of 0.17′′ and a measurement uncertainty of 0.05′′ (k=2). Through method comparisons, it was shown that the improved calibration method can greatly reduce calibration time and improve the calibration efficiency while ensuring the calibration accuracy, and with the decrease of measurement interval, the improvement of calibration efficiency was more obvious.
Źródło:
Metrology and Measurement Systems; 2021, 28, 1; 181-190
0860-8229
Pojawia się w:
Metrology and Measurement Systems
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-2 z 2

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies