Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "Wu, H." wg kryterium: Autor


Tytuł:
Limit cycle oscillation prediction based on Finite Element-Modal approach
Autorzy:
Ahmad, K.
Wu, Z.
Rahman, H.
Powiązania:
https://bibliotekanauki.pl/articles/140294.pdf
Data publikacji:
2018
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
geometrical nonlinearity
unsteady aerodynamics
bending mode
torsional mode
aeroelasticity
flexible structure
nieliniowość geometryczna
aerodynamika niestabilna
tryb zginania
tryb skrętny
aeroelastyczność
struktura elastyczna
Opis:
The central theme of this work was to analyze high aspect ratio structure having structural nonlinearity in low subsonic flow and to model nonlinear stiffness by finite element-modal approach. Total stiffness of high aspect ratio wing can be decomposed to linear and nonlinear stiffnesses. Linear stiffness is modeled by its eigenvalues and eigenvectors, while nonlinear stiffness is calculated by the method of combined Finite Element-Modal approach. The nonlinear modal stiffness is calculated by defining nonlinear static load cases first. The nonlinear stiffness in the present work is modeled in two ways, i.e., based on bending modes only and based on bending and torsion modes both. Doublet lattice method (DLM) is used for dynamic analysis which accounts for the dependency of aerodynamic forces and moments on the frequency content of dynamic motion. Minimum state rational fraction approximation (RFA) of the aerodynamic influence coefficient (AIC) matrix is used to formulate full aeroelastic state-space time domain equation. Time domain dynamics analyses show that structure behavior becomes exponentially growing at speed above the flutter speed when linear stiffness is considered, however, Limit Cycle Oscillations (LCO) is observed when linear stiffness along with nonlinear stiffness, modeled by FE-Modal approach is considered. The amplitude of LCO increases with the increase in the speed. This method is based on cantilevered configuration. Nonlinear static tests are generated while wing root chord is fixed in all degrees of freedom and it needs modification if one requires considering full aircraft. It uses dedicated commercial finite element package in conjunction with commercial aeroelastic package making the method very attractive for quick nonlinear aeroelastic analysis. It is the extension of M.Y. Harmin and J.E. Cooper method in which they used the same equations of motion and modeled geometrical nonlinearity in bending modes only. In the current work, geometrical nonlinearities in bending and in torsion modes have been considered.
Źródło:
Archive of Mechanical Engineering; 2018, LXV, 4; 497-514
0004-0738
Pojawia się w:
Archive of Mechanical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Quantum Chemical Study of Aminonitrocyclopentanes as Possible High Energy Density Materials (HEDMs)
Autorzy:
Bai, J.
Chi, W. J.
Li, L. L.
Yan, T.
Wen, X. E.
Li, B. T.
Wu, H. S.
Ma, F. L.
Powiązania:
https://bibliotekanauki.pl/articles/358101.pdf
Data publikacji:
2013
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Przemysłu Organicznego
Tematy:
cyclopentane derivatives
high energy density materials
impact sensitivity
quantum chemistry
DFT
available free space
Opis:
Nitro and amine groups were introduced into the cyclopentane skeleton, and the heats of formation, detonation performance, bond dissociation energies, and impact sensitivity for these aminonitrocyclopentanes were calculated in detail at the B3LYP/6-311G** level. The results show that all of the derivatives have negative heats of formation, which are influenced by the position of the substituent groups. Their stabilities were estimated and analyzed according to their bond dissociation energies and calculated characteristic H50 values. Most of the compounds were found to have a lower impact sensitivity than HMX. Furthermore, the detonation velocities and detonation pressures were predicted via the Kamlet-Jacobs equation. Of all these aminonitrocyclopentanes, E has the best detonation properties (ρ = 2.05 g/cm3, D = 9.11 m/s, P = 39.62 GPa) and can be considered as a candidate high energy density material.
Źródło:
Central European Journal of Energetic Materials; 2013, 10, 4; 467-480
1733-7178
Pojawia się w:
Central European Journal of Energetic Materials
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Indirect enzyme-linked immunosorbent assay method based on Streptococcus agalactiae rSip-Pgk-FbsA fusion protein for detection of bovine mastitis
Autorzy:
Bu, R.-E.
Wang, I.-L.
Wu, J.-H.
Xilin, G.W.
Chen, J.-L.
Wang, H.
Powiązania:
https://bibliotekanauki.pl/articles/30156.pdf
Data publikacji:
2017
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Opis:
Objective: The aim of this study was to establish a rapid and accurate method for the detection of the Streptococcus agalactiae antibody (SA-Ab) to determine the presence of the bovine mastitis (BM)-causative pathogen. Methods: The multi-subunit fusion protein rSip-Pgk-FbsA was prokaryotically expressed and purified. The triple activities of the membrane surface-associated proteins Sip, phosphoglycerate kinase (Pgk), and fibronectin (FbsA) were used as the diagnostic antigens to establish an indirect enzyme-linked immunosorbent assay (ELISA) method for the detection of SA-Ab in BM. Results: The optimal antigen coating concentration was 2 μg/mL, the optimal serum dilution was 1:160, and the optimal dilution of the enzyme-labeled secondary antibody was 1:6000. The sensitivity, specificity, and repeatability tests showed that the method established in this study had no cross-reaction with antibodies to Streptococcus pyogenes, Escherichia coli, Staphylococcus aureus, and Staphylococcus epidermidis in the sera. The results of the sensitivity test showed that a positive result could be obtained even if the serum dilution reached 1:12,800, indicating the high sensitivity and good repeatability of the method. The positive coincidence rate of this method was 98.6%, which is higher than that of previous tests established with the Sip or Pgk mono-antigen fusion protein, respectively, demonstrating the relatively higher sensitivity of this newly established method. The detection rate for 389 clinical samples was 46.53%. Conclusions: The indirect ELISA method established in this study could provide a more accurate and reliable serological method for the rapid detection of S. agalactiae in cases of BM.
Źródło:
Polish Journal of Veterinary Sciences; 2017, 20, 2
1505-1773
Pojawia się w:
Polish Journal of Veterinary Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Calculation of laser radar cross-section of a spatial object and its experimental verification
Autorzy:
Cao, Y.-H.
Wang, Z.
Bai, L.
Wu, Z.
Li, H.-Y.
Li, Y.-H.
Powiązania:
https://bibliotekanauki.pl/articles/174167.pdf
Data publikacji:
2017
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
bidirectional reflectance distribution function
BRDF
laser radar cross-section
LRCS
spatial object
Opis:
Bidirectional reflectance distribution function of some artificial satellite used materials at the wavelength of 1.06 μm was measured in laboratory. Bidirectional reflectance distribution function (BRDF) models of these materials were established with the five-parameter BRDF model. Laser radar cross-section of a scaled satellite with various materials was calculated, and characteristics of laser radar cross-section of the satellite were discussed. Measurement system to measure laser radar cross-section of the satellite was established and the scaled satellite model was measured. By analyzing the measured data and calculated data, it can be clearly seen that the BRDF of the surface materials and the laser incidence angle are two of main influential factors of the scaled satellite’s laser radar cross-section. These works can provide a reference for design of the lidar system.
Źródło:
Optica Applicata; 2017, 47, 4; 521-532
0078-5466
1899-7015
Pojawia się w:
Optica Applicata
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Effects of the microcrack shape, size and direction on the poroelastic behaviors of a single osteon: a finite element study
Autorzy:
Cen, H-P.
Wu, X-G.
Yu, W-L.
Liu, Q-Z.
Yia, Y-M.
Powiązania:
https://bibliotekanauki.pl/articles/306642.pdf
Data publikacji:
2016
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
poroelastyczność
mikropęknięcie
elementy skończone
osteon
poroelasticity
microcrack
finite element
Opis:
In this work, a finite element study is proposed by using the Comsol Multiphysics software to evaluate the effects of microcrack shape, size and direction on the poroelastic behaviors of a single osteon. Methods: This finite element model is established by using the Comsol Multiphysics software, and we just focus on the comparison of the influences of those microcrack geometric parameters on the osteonal fluid pressure and velocity. Results: The results show that: (1) microcracks in the osteon wall can induce a release of the fluid pressure, but enlarge the velocity in this region; (2) equal-area microcrack with ellipsoid-like shape produced a larger fluid pressure and velocity fields in the osteon than that of rectangular shape; (3) in the elliptic microcracks, the longer of the length (major semi-axis) induces a smaller fluid pressure and velocity amplitudes, whereas the width (minor axis) has little effect; (4) the direction of the microcracks (major axial direction) has an limited influence area around about 1/15 of the osteon cross-sectional area. Conclusions: This model permits the linking of the external loads and microcracks to the osteonal fluid pressure and velocity, which can be used for other purpose associate microcracks with the mechanotransduction and bone remodeling.
Źródło:
Acta of Bioengineering and Biomechanics; 2016, 18, 1; 3-10
1509-409X
2450-6303
Pojawia się w:
Acta of Bioengineering and Biomechanics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Saving water used for vegetable production by applying regulated deficit irrigation practices
Autorzy:
Chang, Y.-S.
Lin, K.-H.
Chen, Y.-J.
Wu, C.-W.
Chang, Y.-J.
Powiązania:
https://bibliotekanauki.pl/articles/13003875.pdf
Data publikacji:
2021
Wydawca:
Uniwersytet Przyrodniczy w Lublinie. Wydawnictwo Uniwersytetu Przyrodniczego w Lublinie
Źródło:
Acta Scientiarum Polonorum. Hortorum Cultus; 2021, 20, 3; 27-36
1644-0692
Pojawia się w:
Acta Scientiarum Polonorum. Hortorum Cultus
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Use of fluorescence quantitative polymerase chain reaction (PCR) for the detection of Escherichia coli adhesion to pig intestinal epithelial cells
Autorzy:
Dai, C.H.
Gan, L.N.
Qin, W.U.
Zi, C.
Zhu, G.Q.
Wu, S.L.
Bao, W.B.
Powiązania:
https://bibliotekanauki.pl/articles/31510.pdf
Data publikacji:
2016
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Opis:
An efficient and accurate method to test Escherichia coli (E. coli) adhesion to intestinal epithelial cells will contribute to the study of bacterial pathogenesis and the function of genes that encode receptors related to adhesion. This study used the quantitative real-time polymerase chain reaction (qPCR) method. qPCR primers were designed from the PILIN gene of E. coli F18ab, F18ac, and K88ac, and the pig β-ACTIN gene. Total deoxyribonucleic acid (DNA) from E. coli and intestinal epithelial cells (IPEC-J2 cells) were used as templates for qPCR. The 2−ΔΔCt formula was used to calculate the relative number of bacteria in cultures of different areas. We found that the relative numbers of F18ab, F18ac, and K88ac that adhered to IPEC-J2 cells did not differ significantly in 6-, 12-, and 24-well culture plates. This finding indicated that there was no relationship between the relative adhesion number of E. coli and the area of cells, so the method of qPCR could accurately test the relative number of E. coli. This study provided a convenient and reliable testing method for experiments involving E. coli adhesion, and also provided innovative ideas for similar detection methods.
Źródło:
Polish Journal of Veterinary Sciences; 2016, 19, 3
1505-1773
Pojawia się w:
Polish Journal of Veterinary Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Generalized integrated importance measure for system performance evaluation: application to a propeller plane system
Uogólniona miara zintegrowanej ważności komponentów jako narzędzie oceny wydajności systemu: zastosowanie w odniesieniu do układu śmigłowca
Autorzy:
Dui, H.
Chen, L.
Wu, S.
Powiązania:
https://bibliotekanauki.pl/articles/301830.pdf
Data publikacji:
2017
Wydawca:
Polska Akademia Nauk. Polskie Naukowo-Techniczne Towarzystwo Eksploatacyjne PAN
Tematy:
wydajność systemu
miara ważności
rozkład Weibulla
szybkość przejścia
system performance
importance measure
Weibull distribution
transition rate
Opis:
Miara zintegrowanej ważności (IIM) pozwala oceniać szybkość zmian wydajności systemu powstałych w wyniku przejścia elementu systemu z jednego stanu do drugiego. IIM pozwala rozważać scenariusze, w których szybkość przejścia elementu z jednego stanu do drugiego jest stała. Jest to jednak sprzeczne z założeniem degradacji, zgodnie z którym wydajność systemu obniża się, w związku z czym, szybkość przejścia może z upływem czasu ulegać zwiększeniu. Rozkład Weibulla opisuje żywotność danego elementu, co wykorzystuje się w wielu różnych zastosowaniach technicznych do modelowania złożonych zbiorów danych. W przedstawionej pracy, rozszerzono IIM uzyskując nową miarę ważności, która pozwala rozważać scenariusze, w których szybkość przejścia elementu z jednego stanu do drugiego w wyniku degradacji jest zależną od czasu funkcją rozkładu Weibulla. Przyjęto, że warunkowy rozkład prawdopodobieństwa elementu przebywającego w pewnym stanie jest rozkładem Weibulla, gdzie dany jest kolejny stan do którego ma przejść dany element. Badania nad nową miarą ważności umożliwiają identyfikację najważniejszych elementów podczas trzech różnych okresów czasu życia systemu, co odpowiada charakterystyce rozkładów Weibulla. Dla ilustracji, wyprowadzono pewne właściwości probabilistyczne i zastosowano rozszerzoną miarę ważności do analizy przykładu rzeczywistego układu śmigłowca.
The integrated importance measure (IIM) evaluates the rate of system performance change due to a component changing from one state to another. The IIM simply considers the scenarios where the transition rate of a component from one state to another is constant. This may contradict the assumption of the degradation, based on which system performance is degrading and therefore the transition rate may be increasing over time. The Weibull distribution describes the life of a component, which has been used in many different engineering applications to model complex data sets. This paper extends the IIM to a new importance measure that considers the scenarios where the transition rate of a component degrading from one state to another is a time-dependent function under the Weibull distribution. It considers the conditional probability distribution of a component sojourning at a state is the Weibull distribution, given the next state that component will jump to. The research on the new importance measure can identify the most important component during three different time periods of the system lifetime, which is corresponding to the characteristics of Weibull distributions. For illustration, the paper then derives some probabilistic properties and applies the extended importance measure to a real-world example (i.e., a propeller plane system).
Źródło:
Eksploatacja i Niezawodność; 2017, 19, 2; 279-286
1507-2711
Pojawia się w:
Eksploatacja i Niezawodność
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Influence of Processing Techniques on Mechanical Properties and Impact Initiation of an Al-PTFE Reactive Material
Autorzy:
Feng, B.
Fang, X.
Li, Y.-C.
Wu, S.-Z.
Mao, Y.-M.
Wang, H.-X.
Powiązania:
https://bibliotekanauki.pl/articles/358654.pdf
Data publikacji:
2016
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Przemysłu Organicznego
Tematy:
Al-PTFE
reactive materials
quasi-static compression
impact initiation
Opis:
Reactive materials (RMs) or impact-initiated materials have received much attention as a class of energetic materials in recent years. To assess the influence of processing techniques on mechanical properties and impact initiation behaviors of an Al-PTFE reactive material, quasi -static compression tests and drop-weight tests were performed. Scanning electron microscopy (SEM) was used to identify the characteristics of the interior microstructures of the Al-PTFE samples. A sintering process was found to transform Al-PTFE from a brittle to a ductile material with an increased elasticity modulus (from 108-160 MPa to 256-336 MPa) and yield stress (from 12-16 MPa to 19-20 MPa). Increasing the molding pressure from 36 MPa to 182 MPa increased the elastic modulus of all Al-PTFE samples and also the yield stress of unsintered ones. Unsintered samples in general required less energy to initiate than sintered ones. As the molding pressure increased, the impact initiation energy for sintered Al-PTFE fell from 96 J to 68 J, whereas the initiation energy for unsintered Al-PTFE rose from 68 J to 85 J. PTFE nanofiber networks observed in sintered samples formed under the higher molding pressures could contribute to the opposite trends observed in the impact initiation energy of unsintered and sintered Al-PTFE samples.
Źródło:
Central European Journal of Energetic Materials; 2016, 13, 4; 989-1004
1733-7178
Pojawia się w:
Central European Journal of Energetic Materials
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Advanced Characterization of Material Properties on the Nanometer Scale Using Atomic Force Microscopy
Autorzy:
Fenner, M.
Wu, S.
Yu, J.
Huber, H.
Kienberger, F.
Powiązania:
https://bibliotekanauki.pl/articles/1490089.pdf
Data publikacji:
2012-02
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Tematy:
77.55.-g
07.79.-v
68.37.Ps
68.37.Uv
07.57.Pt
Opis:
We report recent advances in material characterization on the nanometer scale using scanning microwave microscopy. This combines atomic force microscopy and a vector network analyzer using microwave tip sample interaction to characterize dielectric and electronic material properties on the nanometer scale. We present the methods for calibration as well as applications. Scanning microwave microscopy features calibrated measurements of: (1) capacitance with attofarad sensitivity. For calibration a well characterized array of capacitors (0.1 fF to 10 fF) is used. The method is applied to determine the dielectric properties of thin organic films, (2) Semiconductor dopant density. Calibration is performed by imaging the cross-section of a standard sample with differently doped layers (dopant stair case) from $10^{16}$ atoms/$cm^3$ to $10^{20}$ atoms/$cm^3$.
Źródło:
Acta Physica Polonica A; 2012, 121, 2; 416-419
0587-4246
1898-794X
Pojawia się w:
Acta Physica Polonica A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The effects of cavity geometry on an aspirated compressor cascade
Autorzy:
Guo, S.
Lu, H.-W.
Liu, J.
Wu, C.-J.
Powiązania:
https://bibliotekanauki.pl/articles/280871.pdf
Data publikacji:
2014
Wydawca:
Polskie Towarzystwo Mechaniki Teoretycznej i Stosowanej
Tematy:
highly loaded compressor cascade
boundary layer suction
suction flow distribution
off-take cavity
Opis:
The impact of the bleed off-take cavity within aspirated blades on the aerodynamic perfor- mance of a highly loaded compressor cascade was explored. Three-dimensional Navier-Stokes simulations were conducted in rectangular compressor cascades after validation against expe- rimental results were done. Five different off-take configurations with varying suction loca- tion were numerically evaluated. The results show that the regularities of the suction flow distribution on the suction slot inlet greatly influence the benefits of boundary layer suction. The distribution style greatly depends not only on the flow condition of the blade passage, but also on the realization of the suction process and the geometry of the cavity inside the aspirated blade. The low kinetic fluid in the endwall region compared with that around the midspan is usually prone to be sucked into the suction slot. The distribution of the suc- tion mass flow along the spanwise direction would be symmetrical if the suction position is properly selected and the inside off-take cavity is well designed, even though the bleeding system has been simplified to be asymmetrical as employed in the present document.
Źródło:
Journal of Theoretical and Applied Mechanics; 2014, 52, 1; 117-128
1429-2955
Pojawia się w:
Journal of Theoretical and Applied Mechanics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Construction of waveform library in cognitive radar
Autorzy:
Guo, Y.
Wu, Y.
Liu, H.
Powiązania:
https://bibliotekanauki.pl/articles/260610.pdf
Data publikacji:
2017
Wydawca:
Politechnika Gdańska. Wydział Inżynierii Mechanicznej i Okrętownictwa
Tematy:
fractional Fourier transform
ambiguity function
Barker
Frank
waveform libraries
Opis:
Based on the thoughts of cognitive radar, Fractional Fourier Transform (FrFT) is used to generate a rotatable waveform libraries of Frank coded/Barker coded waveform in this paper. Then, the ambiguity function is used to analyze the delay resolution, Doppler resolution, delay side-lobe level, and Doppler side-lobe level of the waveform libraries and orthogonality of them is also analyzed. Furthermore, we proved theoretically that there is a fixed coordinate transformation between the waveforms of library and its origin waveform. Therefore, the Cramér-Rao low bound (CRLB) of motion parameters can be computed easily using the waveforms of the libraries, which facilitate the subsequent waveform scheduled work. Simulation results show that the library waveforms can reduce delay resolution to satisfy the different situations and can bring significant benefits for delay resolution, orthogonality and reuse interval.
Źródło:
Polish Maritime Research; 2017, S 2; 22-29
1233-2585
Pojawia się w:
Polish Maritime Research
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
A CTS pump with a crossed-coupled output for higher conversion efficiency
Autorzy:
Hsieh, Z. H.
Huang, N. X.
Shiau, M. S.
Wu, H. C.
Yang, S.-Y.
Liu, D.-G.
Powiązania:
https://bibliotekanauki.pl/articles/397847.pdf
Data publikacji:
2010
Wydawca:
Politechnika Łódzka. Wydział Mikroelektroniki i Informatyki
Tematy:
DC-DC przetwornice
CTS ładunek pompy
sprzężenie skrośne ładunku pompy
DC-DC converter
CTS charge pump
cross coupled charge pump
Opis:
In this paper, a novel switching-capacitor DC-DC voltage converter with higher efficiency will be presented. This circuit was designed by modifying the output stage of the conventional static charge-transfer-switch (CTS) charge pump in a cross-coupled configuration. In this design, a control scheme to overcome both the reverse charge sharing and the threshold drops in the CTS pump was also employed. In this study, the capacitances for all the pumping capacitors were selected the same as 0.1 μF. With this design, our circuit can operate with a clock rate up to 1 MHz. The performance of this circuit was first evaluated by simulation by HSPICE with the 0.35-μm technology of TSMC. The results showed that this circuit can pump the low input of 1.5V nearly 5 times at the output. The conversion gain can be around 95%. The performance of the real chip manufactured by TSMC was measured and will be compared with the simulation results.
Źródło:
International Journal of Microelectronics and Computer Science; 2010, 1, 1; 9-14
2080-8755
2353-9607
Pojawia się w:
International Journal of Microelectronics and Computer Science
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The unsteadiness of tip clearance flow and its effect to stability of transonic axial compressor
Nieustaloność przepływu w szczelinie wierzchołkowej i jej wpływ na stabilność pracy przydźwiękowej sprężarki osiowej
Autorzy:
Hu, J. F.
Zhu, X. C.
Ou-Yang, H.
Tian, J.
Wu, Y. D.
Qiang, X. Q.
Zhao, G.
Du, Z. H.
Powiązania:
https://bibliotekanauki.pl/articles/281445.pdf
Data publikacji:
2013
Wydawca:
Polskie Towarzystwo Mechaniki Teoretycznej i Stosowanej
Tematy:
tip leakage flow
compressor
stability
Opis:
The steady and unsteady RANS simulations of a transonic compressor rotor (NASA rotor 37) are performed to investigate the tip clearance flow characteristic and correlations between tip leakage flow and compressor stability. For steady simulations, the results are compared with the aerodynamic probe and laser anemometer data. The speed lines and span-wise aerodynamic parameters agree well with the experimental data. On the other hand, the tip clearance flow of unsteady simulations are analysed clearly at a near stall condition. The results show that there is a mass flow rate boundary. The tip clearance flow oscillates substantially with a frequency about 50% BPF when the mass is less than that, which is caused by tip clearance flow, shock, and the interaction between them and the oncoming flow. The interface between the oncoming flow and clearance flow shifts forward, and the tip clearance flow may spill over into the adjacent blade passage as the mass flow decreases, which may results in the spike stall inception.
W pracy przedstawiono symulacje stanu ustalonego i nieustalonego przydźwiękowej sprężarki osiowej (turbina NASA 37) z zastosowaniem metody Reynoldsa uśredniania równań Naviera-Stokesa (RANS) w celu zbadania charakterystyki przepływu w szczelinie wierzchołkowej oraz określenia zależności pomiędzy stratami związanymi z upływem w tej szczelinie a stabilnością pracy sprężarki. Wyniki symulacji stanu ustalonego porównano z danymi doświadczalnymi uzyskanymi za pomocą sondy aerodynamicznej i laserowego wiatromierza. Wyznaczone wzdłuż rozpiętości sprężarki linie prędkości przepływu i jego parametry aerodynamiczne okazały się zgodne z danymi doświadczalnymi. W przypadku symulacji stanu nieustalonego, analizę przepływu w szczelinie wierzchołkowej przeprowadzono dla warunków bliskich oderwania, tj. utraty wydajności sprężarki, wyznaczając graniczny wydatek przepływu dla takiej sytuacji. Poniżej tej granicznej wartości, zmiany przepływu w szczelinie oscylują z częstotliwością sięgającą 50% częstotliwości przejścia łopatek (tzw. BPF), co jest konsekwencją interakcji wywołanej zderzeniem przepływu z falą napływową w szczelinie wierzchołkowej. Powierzchnia tej interakcji przesuwa się do przodu, a sam przepływ może rozpaść się na fragmenty znajdujące ujście w kanałach przyległych łopatek. Zjawisko to zachodzi przy malejącym wydatku, a to z kolei może indukować oderwanie przepływu skokowymi zmianami mocy współpracującego silnika.
Źródło:
Journal of Theoretical and Applied Mechanics; 2013, 51, 2; 431-438
1429-2955
Pojawia się w:
Journal of Theoretical and Applied Mechanics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Reduced stress and fluctuation for the integrated α-Si TFT gate driver on the LCD
Autorzy:
Huang, N. X.
Shiau, M. S.
Wu, H.-C.
Sun, R. C.
Liu, D.-G.
Powiązania:
https://bibliotekanauki.pl/articles/397883.pdf
Data publikacji:
2010
Wydawca:
Politechnika Łódzka. Wydział Mikroelektroniki i Informatyki
Tematy:
sterownik bramy
fluktuacja hałasu
wpływ naprężenia
system w panelu
gate driver
fluctuation noise
stress effect
system on panel (SoP)
Opis:
In this paper, an integrated TFT gate driver was designed on the glass substrate not only to decrease the fluctuation at the output, but also to reduce the stress effect on the pull-down branches. The fluctuation in the voltage at the output transistor was attributed to the coupled clocks through the parasitic capacitors in the TFTs. In this study, the voltage gating the pull-down braches was reduced for longer operational lifetime. This scheme was investigated by simulation by Smart-SPICE with an α-Si TFT model from Wintek Inc. at level 35.
Źródło:
International Journal of Microelectronics and Computer Science; 2010, 1, 3; 311-315
2080-8755
2353-9607
Pojawia się w:
International Journal of Microelectronics and Computer Science
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies