Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "Wiśniewski, Dariusz." wg kryterium: Autor


Wyświetlanie 1-11 z 11
Tytuł:
Analysis of a Method for Measuring Deposit Impedance Parameters Using Charge Amplifier and Lock-in Voltmeter
Autorzy:
Wiśniewski, Dariusz R.
Powiązania:
https://bibliotekanauki.pl/articles/2069749.pdf
Data publikacji:
2021
Wydawca:
Uniwersytet Warmińsko-Mazurski w Olsztynie
Tematy:
impedance
conductivity
moisture content
deposit
charge amplifier
lock-in voltmeter
Opis:
Methods for measuring deposit parameters are often based on a capacitance or conductivity measurement aimed at estimating, e.g. deposit moisture content. In practice, these methods fail for materials with a low degree of homogeneity, a diverse porous structure or high conductivity, e.g. due to a high water content. This article demonstrates an approach that enables a more precise estimation of the parameters of any deposit. The presented method involves the use of a measuring system in a charge amplifier configuration and the application of a technique using lock-in detection or a lock-in voltmeter to determine resistance and capacitance parameters of a deposit based on signals received from the measuring system. This method can be successfully used wherever the test deposit material is highly heterogeneous and contains both dielectric and conductive materials. The article presents an example of a solution to a measuring system using two planar electrodes that can be dimensioned depending on the deposit dimensions. It is followed by a presentation of a method for converting the signal from the measuring system into impedance parameters of the deposit using a lock-in voltmeter. The analysis of the operation of the entire measuring system was modelled in Matlab/Simulink, and the operation results were presented.
Źródło:
Technical Sciences / University of Warmia and Mazury in Olsztyn; 2021, 24(1); 67--81
1505-4675
2083-4527
Pojawia się w:
Technical Sciences / University of Warmia and Mazury in Olsztyn
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Podsumowanie projektu EMRP IND53 LUMINAR Large volume metrology in industry
Summary of the EMRP IND53 LUMINAR project Large volume metrology in industry
Autorzy:
Wiśniewski, Mariusz
Czułek, Dariusz
Szumski, Robert
Powiązania:
https://bibliotekanauki.pl/articles/952617.pdf
Data publikacji:
2018
Wydawca:
Główny Urząd Miar
Tematy:
projekt LUMINAR
techniki pomiarowe
przyrządy pomiarowe
LUMINAR project
Large volume metrology in industry
measurement techniques
measuring instruments
Opis:
W ramach międzynarodowego projektu LUMINAR opracowano szereg prototypowych przyrządów pomiarowych do pomiarów w dużych objętościach (LVM), nowych sposobów i oprogramowania do kompensacji wpływu czynników atmosferycznych oraz zniekształceń termicznych. Zbudowane przyrządy pomiarowe zostały pomyślnie przetestowane i zademonstrowane w laboratoriach i zakładach przemysłowych.
As part of the international LUMINAR project, a number of prototype measuring instruments for large volume metrology (LVM), new methods and software to compensate for atmospheric factors and thermal distortions were developed. Measuring instruments have been successfully tested and demonstrated in laboratories and industrial plants.
Źródło:
Metrologia i Probiernictwo : biuletyn Głównego Urzędu Miar; 2018, 2 (21); 40-42
2300-8806
Pojawia się w:
Metrologia i Probiernictwo : biuletyn Głównego Urzędu Miar
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Problemy pomiarów odkształconych przebiegów prądowych przy zastosowaniu dostępnych na rynku przekładników i przetworników prądowo-napięciowych
Problems of measuring distorted currents using commercially available current transformers and current-voltage transducers
Autorzy:
Wiśniewski, Grzegorz
Macierzyński, Dariusz
Habrych, Marcin
Miedziński, Bogdan
Powiązania:
https://bibliotekanauki.pl/articles/199218.pdf
Data publikacji:
2019
Wydawca:
Instytut Techniki Górniczej KOMAG
Tematy:
urządzenia zasilające górnicze sieci elektroenergetyczne
przetworniki prądowo-napięciowe
przekładniki prądowe
błędy prądowe
błędy kątowe
mining power networks
current-voltage converters
current transformers
current errors
angle errors
Opis:
W artykule przedstawiono porównawcze wyniki badań właściwości metrologicznych wybranych, dostępnych na rynku przekładników i przetworników prądowych. Sformułowano odpowiednie wnioski odnośnie do ich przydatności w układach pomiarowych prądów o stosunkowo małych wartościach (od 1 A do 30 A) ale o częstotliwości zmieniającej się w zakresie od 10 Hz do 550 Hz.
The article presents comparative results of metrological properties of selected current transformers and current -voltage transducers available on the market. Appropriate conclusions were formulated regarding their usefulness in current measuring systems with relatively small values (from 1 A to 30 A) but with a frequency varying from 10 Hz to 550 Hz.
Źródło:
Maszyny Górnicze; 2019, 37, 4; 3-14
0209-3693
2450-9442
Pojawia się w:
Maszyny Górnicze
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Metalurgia proszków w Sieci Badawczej Łukasiewicz – Instytucie Obróbki Plastycznej
Powder metallurgy in Łukasiewicz Research Network – Metal Forming Institute
Autorzy:
Garbiec, Dariusz
Leshchynsky, Volf
Wiśniewski, Tomasz
Rubach, Rafał
Wiśniewska, Maria
Powiązania:
https://bibliotekanauki.pl/articles/211996.pdf
Data publikacji:
2019
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Obróbki Plastycznej
Tematy:
metalurgia proszków
prasowanie
spiekanie
spiekanie iskrowo-plazmowe
powder metallurgy
compacting
sintering
spark plasma sintering
Opis:
W artykule przedstawiono metody metalurgii proszków wykorzystywane do wykonywania wyrobów z proszków metalicznych i ceramicznych w Sieci Badawczej Łukasiewicz – Instytucie Obróbki Plastycznej. Do wytwarzania zaawansowanych materiałów metalicznych, ceramicznych oraz kompozytowych zastosowano nowoczesną metodę spiekania iskrowo-plazmowego z wykorzystaniem urządzenia SPS HP D 25-3. Urządzenie to pozwala na realizację procesów spiekania w temperaturze do 2200°C z jednoczesnym prasowaniem z siłą do 250 kN w próżni, atmosferze azotu, argonu lub wodoru. Z kolei do wykonywania wyrobów z proszków na bazie żelaza stosowana jest konwencjonalna metoda prasowania jednoosiowego na zimno i następującego po nim spiekania swobodnego w atmosferze azotowo-wodorowej zdysocjowanego amoniaku z wykorzystaniem gniazda badawczo-doświadczalnego GSMP-75 wyposażonego w piec wgłębny retortowy PSF-12/75. Maksymalna temperatura spiekania wynosi 1200°C. Ponadto omówiono przykładowe prace naukowo-badawcze zrealizowane w ramach zarówno projektów międzynarodowych finansowanych z 7 PR UE oraz Horyzontu 2020, jak i projektów krajowych realizowanych we współpracy z przemysłem. Zaprezentowano wybrane wyniki badań dotyczące kompozytowych sektorów tnących stosowanych w piłach do cięcia kamieni, kompozytowych elektrod nasadkowych stosowanych w zrobotyzowanych stanowiskach zgrzewania punktowego oraz płytek skrawających wykonanych z węglików spiekanych stosowanych w obróbce mechanicznej metali. Poza tym wskazano gałęzie przemysłu, na potrzeby których ŁUKASIEWICZ – INOP wykonuje prace naukowo-badawcze oraz realizuje wdrożenia. Zaprezentowano także ofertę współpracy dla przemysłu.
The article presents the powder metallurgy methods used to make products from metallic and ceramic powders in the Łukasiewicz Research Network – Metal Forming Institute. To produce advanced metallic, ceramic and composite materials, the method of spark plasma sintering employing an SPS HP D 25-3 was used. This device allows sintering processes to be performed at temperatures up to 2200°C with simultaneous compaction with a force of up to 250 kN in vacuum, and in a nitrogen, argon or hydrogen atmosphere. On the other hand, to make products from iron-based powders, the conventional method of cold uniaxial pressing and subsequent free sintering in a nitrogen-hydrogen atmosphere of dissociated ammonia employing a GSMP-75 research and testing socket equipped with a PSF-12/75 retort furnace is used. The maximum sintering temperature is 1200°C. In addition, examples of scientific and research work carried out as part of international projects financed from EU FP7 and Horizon 2020, as well as national projects executed in cooperation with industry are discussed. Selected research results concerning composite cutting sectors used in saws for cutting stones, composite cap electrodes used in robotic spot welding stations and cutting inserts made of cemented carbides used in metal machining were presented. In addition, the branches of industry were identified for which the Łukasiewicz Research Network – Metal Forming Institute performs scientific and research works and executes implementations. A cooperation offer for industry was also presented.
Źródło:
Obróbka Plastyczna Metali; 2019, 30, 3; 189-200
0867-2628
Pojawia się w:
Obróbka Plastyczna Metali
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Ocena czynników ryzyka rekanalizacji embolizowanych pękniętych tętniaków umiejscowionych na tylnej części koła tętniczego Willisa
Autorzy:
Wiśniewski, Karol
Tomasik, Bartłomiej
Bobeff, Ernest J
Stefańczyk, Ludomir
Jaskólski, Dariusz J
Powiązania:
https://bibliotekanauki.pl/articles/1393166.pdf
Data publikacji:
2017
Wydawca:
Index Copernicus International
Tematy:
embolizacja
tętniak tylnej części koła tętniczego Willisa
krwotok podpajęczynówkowy
czynniki ryzyka
Opis:
Wprowadzenie: Tętniaki umiejscowione na tylnej części koła tętniczego Willisa są częstą przyczyną krwawienia podpajęczynówkowego (ang. aneurysmal subarachnoid haemorrhag;e - aSAH) i stanowią około 30% wszystkich tętniaków wewnątrzczaszkowych. Ze względu na duże ryzyko operacyjne, chorzy z tętniakami tylnego kręgu są kierowani na leczenie wewnątrznaczyniowe. Embolizacja, czyli upakowanie tętniaka spiralami, jest obarczona dużym ryzykiemą niedogodnością, jaką jakim jest wystąpienie rekanalizacji i powstanie tętniaka nawrotowego. W pracy przeprowadziliśmy analizę parametrów morfometrycznych tętniaków tylnego kręgu w celu znalezienia markera radiologicznego zwiastującego wystąpienia rekanalizacji. Materiał i metody: Analizie retrospektywnej poddano dane kliniczne dwudziestu czterech24 pacjentów z tętniakami tylnego kręgu, którzy leczeni byli na drodze klasycznej embolizacji. Pomiary morfometryczne wykonano na modelach 3D tętniaka otrzymywanych za pomocą przedoperacyjnego badania angio-CT nn. mózgowych. Wielkość i objętość tętniaka mierzono na podstawie obrazów otrzymanych w cyfrowej angiografii subtrakcyjnej. Skuteczność początkowego leczenia endowaskularnego określono wizualnie przy użyciu zmodyfikowanej skali Raymond Roy, po embolizacji i podczas kontrolnej angiografii. Rekanalizację diagnozowano, obserwując wypełnienie tętniaka podczas badania. Analizę statystyczną przeprowadzono stosując oprogramowanie Statistica 13.1 Wyniki: Stwierdzono, że największy wymiar tętniaka prostopadły do jego szyi, był istotnie związany z rekanalizacją (12,12 ± 5,13 mm vs. 7,41 ± 3,97 mm, p = 0,039), i pozostał istotny po uwzględnieniu efektu wieku, płci i lokalizacji tętniaka (OR = 1,26 , 95% CI: 1,01-1,60, p = 0,047). Wykazaliśmy również, że największy wymiar tętniaka prostopadły do jego szyi jest dobrym klasyfikatorem umożliwiającym różnicowanie pomiędzy zrekanalizowanymi a niezrekanalizowanymi tętniakami tylnego kręgu (AUC = 0,755, 95% CI: 0,521-–0,989, p = 0,033).
Źródło:
Polish Journal of Surgery; 2017, 89, 6; 7-11
0032-373X
2299-2847
Pojawia się w:
Polish Journal of Surgery
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Predictors of recanalization after endovascular treatment of posterior circulation aneurysms
Autorzy:
Wiśniewski, Karol
Tomasik, Bartłomiej
Bobeff, Ernest J
Stefańczyk, Ludomir
Jaskólski, Dariusz J
Powiązania:
https://bibliotekanauki.pl/articles/1393121.pdf
Data publikacji:
2017
Wydawca:
Index Copernicus International
Tematy:
embolization
posterior circulation aneurysms
subarachnoid hemorrhage
predictors
Opis:
Introduction. Posterior circulation aneurysms account for approximately 30% of all intracranial aneurysms, and their rupture often causes aneurysmal subarachnoid hemorrhage (aSAH). Because surgical treatment of posterior circulation aneurysms is difficult, endovascular treatment is commonly indicated. However, simple coil embolization is associated with a high rate of recanalization. Our goal was to investigate morphometric aneurysmal features assessed on pre-embolization computed tomography angiography (CTA) as predictors of recanalization in patients with posterior circulation aneurysms. Material and Methods. We retrospectively analyzed data of 24 patients who underwent coil embolization due to rupture of saccular posterior circulation aneurysms. The morphometric features of aneurysms were measured based on pre-embolization 3D-CTA-aneurysm models, and aneurysmal size and volume were measured on digital subtraction angiography (DSA) images. The effectiveness of initial endovascular treatment was determined visually with the modified Raymond Roy classification directly after embolization and on follow-up DSAs. Recanalization was diagnosed when, compared to the primary embolization aneurysm appearance, compaction and filling of the aneurysm occurred. Statistical analysis was performed with Statistica 13.1 software. Results. Higher maximal aneurysm height perpendicular to the aneurysmal neck was associated with a greater aneurysm recanalization risk (12.12±5.13mm vs. 7.41±3.97mm, p=0.039), and this relationship remained significant after adjustment for patient’s age, sex and aneurysm localization (OR=1.26, 95%CI: 1.01-1.60, p=0.047). Maximal aneurysm height perpendicular to the aneurysmal neck distinguished well between recanalized and non-recanalized aneurysms (AUC=0.755, 95%CI: 0.521- 0.989, p=0.033). Conclusions. Predictors of aneurysm recanalization can help choose best endovascular treatment strategies, which could reduce complication rates.
Źródło:
Polish Journal of Surgery; 2017, 89, 6; 7-11
0032-373X
2299-2847
Pojawia się w:
Polish Journal of Surgery
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-11 z 11

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies