Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "Werner, A." wg kryterium: Autor


Tytuł:
A hierarchy of finite state machines as a scenario player in interactive training of pilots in flight simulators
Autorzy:
Bach, Małgorzata
Werner, Aleksandra
Mrozik, Magda
Cyran, Krzysztof A.
Powiązania:
https://bibliotekanauki.pl/articles/2055173.pdf
Data publikacji:
2021
Wydawca:
Uniwersytet Zielonogórski. Oficyna Wydawnicza
Tematy:
Bayesian inference
deterministic Moore machine
flight simulator
finite state machine
scenario player
wnioskowanie Bayesa
automat Moore'a
symulator lotu
automat skończony
Opis:
The paper presents the concept of a control unit, i.e., a scenario player, for interactive training pilots in flight simulators. This scenario player is modelled as a hierarchy of finite state machines. Such an approach makes it possible to separate the details of an augmented reality display device which is used in training, from the core module of the system, responsible for contextual organization of the content. Therefore, the first contribution of this paper is the mathematical model of the scenario player as a universal formulation of the self-trained control unit for interactive learning systems, which is applicable in a variety of situations not limited solely to flight simulator related procedures. The second contribution is an experimental verification achieved by extensive simulations of the model, which proves that the proposed approach is capable to properly self-organize details of the context information by tracing preferences of the end users. For that latter purpose, the original algorithm is derived from statistical analysis, including Bayesian inference. The whole approach is illustrated by a real application of training the preflight procedure for the captain of the Boeing 737 aircraft in a flight simulator.
Źródło:
International Journal of Applied Mathematics and Computer Science; 2021, 31, 4; 713--727
1641-876X
2083-8492
Pojawia się w:
International Journal of Applied Mathematics and Computer Science
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The influence of thermal bridges on the operation of underfloor heating system
Autorzy:
Werner-Juszczuk, A.
Powiązania:
https://bibliotekanauki.pl/articles/96810.pdf
Data publikacji:
2018
Wydawca:
Fundacja Ekonomistów Środowiska i Zasobów Naturalnych
Tematy:
thermal efficiency
surface temperature
heat loss
surface heating system
wydajność termiczna
temperatura na powierzchni
strata ciepła
system ogrzewania powierzchni
Opis:
The work determines the influence of the presence of thermal bridges within the pipes of underfloor heating on its performance: thermal efficiency, surface temperature and heat losses. Three types of building partitions with thermal bridges are considered: the external wall, the external wall with the insulated and uninsulated balcony slab. The analysis was made for variable heat resistance of thermal insulation and floor finishing layer, variable pipe spacing, temperature of the heating medium and outside air. The calculation was carried out with the use of computer software using boundary element method (BEM). It was found that considering three types of thermal bridges in the floor heating model does not significantly affect the thermal efficiency of the floor heating and its average surface temperature. The effect of considering the thermal bridges on the amount of heat losses to the room below was observed.
Źródło:
Ekonomia i Środowisko; 2018, 2; 154-167
0867-8898
Pojawia się w:
Ekonomia i Środowisko
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Modification of filtering materials with aerogel for improvement of oil mist separation
Modyfikacja materiałów filtracyjnych aerożelem w celu poprawy separacji mgły olejowej
Autorzy:
Nowak, B.
Gac, J.M.
Bojarska, M.
Jackiewicz, A.
Werner, Ł.
Powiązania:
https://bibliotekanauki.pl/articles/2073249.pdf
Data publikacji:
2017
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
liquid aerosol filtration
filtering materials
aerogel
filter modification
filtracja aerozolu ciekłego
włókniny filtracyjne
aerożel
modyfikacja filtrów
Opis:
Filtration of liquid aerosol (mist) is one of the most important challenges in many branches of chemical industry. One of the possible ways of filtering materials improvement is modification with aerogels. In this study aerogels based on methytrimethoxysilane (MTMS) which exhibit superhydrophobic, superoleophilic and sorptive (thanks to high porosity) properties were used. Modified filtering materials improve the general retention and fractional efficiency o f oil mist separation in micro- and nanoscale. Although the pressure drop during the filtration on modified filters has been higher, the presented results seem to be promising.
Filtracja aerozoli olejowych (mgły) jest jednym z wyzwań spotykanych w wielu gałęziach przemysłu chemicznego. Jedną z możliwych dróg poprawy właściwości włóknin filtracyjnych jest modyfikacja aerożelem. W niniejszej pracy został wykorzystany aerożel oparty na metyl-trimetoksysilanie (MTMS), który posiada właściwości hydrofobowe, olejofilowe i sorpcyjne względem olei (dzięki dużej porowatości). Modyfikacja włókniny dała poprawę wyników retencji oraz efektywności separacji mgły olejowej w skali mikro i nano. Pomimo wzrostu spadku ciśnienia na filtrach modyfikowanych, uzyskane rezultaty są obiecujące.
Źródło:
Inżynieria i Aparatura Chemiczna; 2017, 1; 17--20
0368-0827
Pojawia się w:
Inżynieria i Aparatura Chemiczna
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Pomiar momentu obrotowego : propozycja metody uśredniania
Torque measurement : proposal of data averaging method
Autorzy:
Goszczak, J.
Radzymiński, B.
Werner, A.
Powiązania:
https://bibliotekanauki.pl/articles/316134.pdf
Data publikacji:
2017
Wydawca:
Instytut Naukowo-Wydawniczy "SPATIUM"
Tematy:
moment obrotowy
obliczanie
zakłócenia
torque
measurement
noise
Opis:
Przy badaniach obracających się zespołów i maszyn, głównie, ale nie tylko dla oceny ich zdolności wytwarzania mocy lub jej strat, potrzebny jest wiarygodny pomiar momentu obrotowego. Pomiar tej istotnej wielkości fizycznej towarzyszy nie tylko badaniom stanowiskowym, lecz wykorzystywany jest on również w seryjnych pojazdach samochodowych, chociażby w przekładniach kierowniczych czy do sterowania skrzyniami biegów[1]. Istnieje wiele czynników zakłócających ten pomiar. Część z nich w wielu przypadkach jest niemożliwa do zdefiniowania, a nawet pośród tych czynników zakłócających, które zostały określone, redukcja ich do poziomu w pełni zadawalającego jest z reguły niemożliwa. W związku z powyższym, sygnał momentu obrotowego często zostaje poddany różnego typu opracowaniu zanim zostanie np. wysłany do sterownika . W tym celu stosuje się m.in. rozmaite rodzaje filtrów bądź opracowania statystyczne, pośród których najprostszym przykładem jest uśrednianie arytmetyczne. W artykule po przedstawieniu najpopularniejszych źródeł zakłóceń i metod walki z nimi, omówiona została propozycja metody uśredniania momentu obrotowego w trakcie pomiaru. Pomimo, iż pomiary z uśrednianiem wartości mierzonej z reguły mogą być stosowane do przebiegów statycznych/wolnozmiennych, opisana propozycja metody pomiaru nadaje się do pomiarów zmiennych/dynamicznych, gdyż uśrednianie zachodzi w ramach jednego obrotu wału. Przedstawiono opis propozycji, przebiegi wartości momentu obrotowego bez jakiegokolwiek opracowania oraz z zastosowaniem autorskiej metody. W zakończeniu sformułowano wnioski wynikające z przedstawionych wyników badań.
Reliable and repeatable torque measurement is a crucial issue during every research and in every kind of system which operation is based on torque value. Although the progress is done in the science last years, accurate torque measurement is still a problematic issue. After discussing the most popular sources of noise, article describes the authors’ proposal of torque value averaging method during the tests. Despite the fact, that the most of averaged measurements can be used in the static processes, this method is useful also in dynamic measurements because the averaging is performed within one revolution. Description of the method is included, test results without and with proposed data averaging are presented. Summary contains conclusions based on the presented results.
Źródło:
Autobusy : technika, eksploatacja, systemy transportowe; 2017, 18, 6; 700-704, CD
1509-5878
2450-7725
Pojawia się w:
Autobusy : technika, eksploatacja, systemy transportowe
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
PWM-controlled hydraulic solenoid valves for motor vehicles
Elektrozawory hydrauliczne sterowane sygnałem PWM stosowane w pojazdach samochodowych
Autorzy:
Goszczak, J.
Radzymiński, B.
Werner, A.
Pawelski, Z.
Powiązania:
https://bibliotekanauki.pl/articles/1363393.pdf
Data publikacji:
2017
Wydawca:
Sieć Badawcza Łukasiewicz. Przemysłowy Instytut Motoryzacji
Tematy:
PWM signal
electro-valve steering
temperature influence
sygnał PWM
elektrozawór sterowany sygnałem PWM
wpływ temperatury na pracę elektrozaworu
Opis:
Paper presents the characteristics of two hydraulic electro-valves applied in automotive industry, produced by different manufacturers. Such electro-valves are controlled by PWM signal (Pulse With Modulation) and are used to control oil pressure in automatic gearboxes. Paper includes some basic information about PWM signal with its application. In the subsequent chapter, there will be given information about tested valves, acquired by an individual elaboration, including design and the fundamentals of operation. In the followings sections, test bench is described and test results are presented. The temperature turned out as a very important factor which should be taken into account. In case of PWM controlling, for different temperatures some uncertainties of output pressure are possible. To avoid this undesirable phenomenon new control signal is proposed. Different characteristics of electro-valves are included: output pressure as the function of steering signal, the value of force exerted by the slider, responsiveness to a step function of request, regulation possibilities and internal leakages. What is more, occurrence of hysteresis phenomenon is checked. Based on test results a number of conclusions are formulated with some practical pieces of information for the engineers of mechanical systems which contain elements controlled by PWM signal.
Artykuł niniejszy zawiera charakterystykę elektrozaworów hydraulicznych stosowanych w pojazdach samochodowych, pochodzących od dwóch producentów, których zmienną sterującą jest sygnał PWM (ang. Pulse With Modulation). Służą one do regulacji ciśnienia w obwodzie elektrohydraulicznym automatycznej skrzyni biegów pojazdów samochodowych. W artykule omówiono po krótce istotę sygnału PWM oraz jego zastosowanie. Scharakteryzowano badane elektrozawory, wraz z podaniem własnej analizy konstrukcyjnej oraz zasady ich działania. Porównano dwa różne rozwiązania zwracając uwagę na istotne, funkcjonalne różnice między nimi oraz zauważone niedoskonałości tychże rozwiązań. W dalszej części artykułu omówiono stanowisko pomiarowe oraz wyniki badań, w których zwrócono uwagę na istotny wpływ temperatury na niejednoznaczność osiąganych ciśnień w przypadku sterowania przy pomocy sygnału PWM- zaproponowano inną zmienną sterującą, a następnie przedstawiono wyniki badań dla różnych wartości temperatury oleju. Zawarto charakterystyki: wytwarzanego ciśnienia w funkcji sygnału sterującego, sprawdzając występowanie zjawiska histerezy, siły wywieranej przez trzpień elektrozaworu, czasu reakcji na skok jednostkowy o amplitudzie pełnego przesterowania, możliwości regulacyjnych oraz przecieków własnych elektrozaworu. Sformułowano szereg wniosków, nasuwających się po przeprowadzeniu badań, będących praktycznymi i istotnymi wskazówkami dla konstruktorów układów mechanicznych w których zastosowanie znajdują elektrozawory sterowane sygnałem PWM lub inne elementy, których zmienną sterującą jest sygnał PWM.
Źródło:
Archiwum Motoryzacji; 2017, 75, 1; 23-37
1234-754X
2084-476X
Pojawia się w:
Archiwum Motoryzacji
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wind tunnel flux comparisons using a phase Doppler interferometer
Autorzy:
Roten, R.L.
Post, S.L.
Werner, A.
Safa, M.
Hewitt, A.J.
Powiązania:
https://bibliotekanauki.pl/articles/65512.pdf
Data publikacji:
2017
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
wind tunnel
flux measurement
Doppler interferometer
phase Doppler system
droplet
Opis:
It is essential to know the movement of droplets in time and space (i.e. flux) when measuring and/or predicting spray drift in agricultural application. A study was performed to assess the flux measurements of a phase Doppler system against a standard monofilament system in a wind tunnel. The primary objectives of the study were to compare flux from a new phase Doppler system against 1.7 mm cotton and 2.0 mm nylon strings at varying wind speeds (1.4, 4.2, 8.3, 12.5, and 16.7 m ⋅ s–1) and spray exposures times (5, 10, 15, 30, and 60 s) with an overarching hypothesis that the active, phase Doppler is able to accurately measure the flux regardless of exposure and spray mass whereas the static string samplers are limited to a maximum retention. The phase Doppler did measure linearly as expected, however strings did not reach a point in which they loss mass; conversely, they appeared to overload with saturation. These findings are believed to be among many variables which influence the variability of previous mass balance studies.
Źródło:
Journal of Plant Protection Research; 2017, 57, 3
1427-4345
Pojawia się w:
Journal of Plant Protection Research
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wpływ rozmieszczenia izolacji cieplnej w ścianie zewnętrznej na pracę ogrzewania ściennego
The impact of the location of the thermal insulation in the exterior wall on the wall heating performance
Autorzy:
Werner-Juszczuk, A.
Powiązania:
https://bibliotekanauki.pl/articles/105473.pdf
Data publikacji:
2017
Wydawca:
Politechnika Rzeszowska im. Ignacego Łukasiewicza. Oficyna Wydawnicza
Tematy:
ogrzewanie płaszczyznowe
straty ciepła
wydajność cieplna
temperatura powierzchni
surface heating
heat loss
thermal efficiency
surface temperature
Opis:
W referacie określono wpływ sposobu rozmieszczenia izolacji cieplnej w ścianie zewnętrznej z ogrzewaniem ściennym wodnym typu A na jego wydajność cieplną, temperaturę powierzchni oraz straty ciepła. Analizę przeprowadzono dla dwóch wariantów rozmieszczenia izolacji: jedna warstwa izolacji cieplnej od strony środowiska zewnętrznego, oraz dwie warstwy izolacji: jedna na powierzchni zewnętrznej ściany, druga bezpośrednio pod warstwą tynku z rurami. Wariant drugi obejmuje trzy zmienne grubości izolacji cieplnej bezpośrednio pod rurami. W obu wariantach łączny opór cieplny izolacji jest sobie równy. Obliczenia przeprowadzono dla zmiennej temperatury powietrza zewnętrznego i czynnika grzewczego, oporu cieplnego izolacji i warstwy wykończeniowej, rozstawu przewodów. Analizę przeprowadzono na podstawie wyników obliczeń numerycznych przenikania ciepła w ścianie z ogrzewaniem ściennym wykonanych za pomocą programu wykorzystującego metodę elementów brzegowych (MEB). Stwierdzono, że dla analizowanych zmiennych parametrów konstrukcyjnych grzejnika oraz środowiska zewnętrznego wykonanie izolacji cieplnej w dwóch warstwach a nie jednej ma pomijalny wpływ na wydajność cieplną grzejnika ściennego (zmiana maksymalnie o 2,5%) oraz na średnią temperaturę powierzchni grzejnika ściennego i straty ciepła do środowiska zewnętrznego. Rozmieszczenie izolacji cieplnej wpływa natomiast na rozkład izoterm wewnątrz przegrody z grzejnikiem ściennym. Zastosowanie warstwy izolacji cieplnej pod rurami powoduje, że bezwładność cieplna grzejnika ściennego maleje, ze względu na mniejszą masę przegrody budowlanej do nagrzania, co poprawia właściwości regulacyjne systemu.
The paper specifies the influence of the method of thermal insulation distribution in the external wall with type A wall heating on its thermal efficiency, surface temperature and heat loss. The analysis was carried out for two variants of the insulation layout: one thermal insulation layer from the outside side of the wall, and two layers of insulation: one on the external wall surface, the other directly under the plaster layer with the pipes. The second variant covers three variables of thermal insulation thickness directly under the pipes. In both variants, the total thermal resistance of the insulation is equal. The calculations were carried out for the variable external air temperature and heating medium, resistance of thermal insulation and finishing layer, and the spacing of pipes. The analysis was based on the results of numerical calculations of heat transfer in the wall with wall heating made using a program basing on the boundary element method (BEM). It was found that for the analyzed variable parameters of the radiator and the external environment, the use of the two layer of thermal insulation instead of one has a negligible effect on the thermal efficiency of a wall heating (change by a maximum of 2,5%), on the average surface temperature of a wall heating and heat losses to the external environment. The location of the thermal insulation influences the isothermal distribution inside the wall with the wall heating. The use of a thermal insulation layer under the pipes causes the decrement of thermal inertia of the wall radiator due to the lower mass of the heating panel, which improves the system's regulatory properties.
Źródło:
Czasopismo Inżynierii Lądowej, Środowiska i Architektury; 2017, 64, 4/II; 453-466
2300-5130
2300-8903
Pojawia się w:
Czasopismo Inżynierii Lądowej, Środowiska i Architektury
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analiza wpływu zjawiska tarcia na funkcjonowanie przekładni CVT wraz z propozycją stanowiska badawczego
The influence of friction on CVT transmission functionality. New test bench proposition
Autorzy:
Goszczak, J.
Werner, A.
Powiązania:
https://bibliotekanauki.pl/articles/134857.pdf
Data publikacji:
2016
Wydawca:
ADVSEO
Tematy:
CVT transmission
friction
hysteresis
pushbelt
chain
Opis:
The paper discusses friction phenomenon between the pushbelt (or chain) in the continuously variable transmission. This type of transmission is becoming more and more popular. It is so due to the technical progress last years and its indisputable advantage over conventional transmissions. It enables us to use the full characteristic of the engine. The introduction describes the issue, principles of the transmission’s operation, the construction of the steel pushbelt and a scheme of forces acting on a single belt’s steel element (segment). In the next part, the article explains the need of researches and their impact on the transmission’s proceeding. Moreover, a simplified model of the test bench with description of the proposed tests needed to elaborate sought relationships is included in the paper.
Źródło:
Technical Issues; 2016, 4; 15-20
2392-3954
Pojawia się w:
Technical Issues
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Importance of Lean Management in a Contemporary Enterprise – Research Results
Autorzy:
Grzelczak, A.
Werner-Lewandowska, K.
Powiązania:
https://bibliotekanauki.pl/articles/409083.pdf
Data publikacji:
2016
Wydawca:
Politechnika Poznańska. Wydawnictwo Politechniki Poznańskiej
Tematy:
lean management
principles of Lean Management
lean production
traditional technology
Opis:
Lean Management is a management concept that creates a work culture at a company that makes all employees strive to continuously reduce costs, improve the quality and shorten delivery cycle to maximally meet customers’ expectations and adapt to the environment by eliminating any waste identified and integrating the activities connected with the stream creating customer value. The article is aimed at presenting the results of research on the Lean Management concepts in a modem enterprise, conducted among the personnel of enterprises from Wielkopolska, Poland.
Źródło:
Research in Logistics & Production; 2016, 6, 3; 195-206
2083-4942
2083-4950
Pojawia się w:
Research in Logistics & Production
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
PCR, Real-Time PCR and molecular characteristic of Toxoplasma gondii isolates from wild aquatic birds: preliminary analysis
Autorzy:
Lass, A.
Solarczyk, P.
Kavetska, K.
Dzierzba, E.
Werner, A.
Majewska, A.C.
Powiązania:
https://bibliotekanauki.pl/articles/6029.pdf
Data publikacji:
2016
Wydawca:
Polskie Towarzystwo Parazytologiczne
Tematy:
polymerase chain reaction
real-time PCR method
molecular characteristics
Toxoplasma gondii
isolate
parasite
wild animal
bird
aquatic bird
Źródło:
Annals of Parasitology; 2016, 62, Suppl.
0043-5163
Pojawia się w:
Annals of Parasitology
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Channeling Study of Co and Mn Implanted and Thermally Annealed Wide Band-Gap Semiconducting Compounds
Autorzy:
Ratajczak, R.
Werner, Z.
Barlak, M.
Pochrybniak, C.
Stonert, A.
Zhao, Q.
Powiązania:
https://bibliotekanauki.pl/articles/1402209.pdf
Data publikacji:
2015-11
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Tematy:
61.43.-j
61.72.-y
81.05.-t
82.80.-d
85.40.-e
Opis:
The defect build-up, structure recovery and lattice location of transition metals in ion bombarded and thermally annealed ZnO and GaN single crystals were studied by channeled Rutherford backscattering spectrometry and channeled particle-induced X-ray emission measurements using 1.57 MeV ⁴He ions. Ion implantation to a fluence of 1.2×10¹⁶ ions/cm² was performed using 120 keV Co and 120 keV Mn ions. Thermal annealing was performed at 800°C in argon flow. Damage distributions were determined using the Monte Carlo McChasy simulation code. The simulations of channeled Rutherford backscattering spectra reveal that the ion implantation leads to formation of two types of defect structures in ZnO and GaN such as point and extended defects, such as dislocations. The concentrations of both types of defects are at a comparable level in both structures and for both implanted ions. Differences between both implantations appear after thermal annealing where the Mn-doped ZnO reveals much better transition metals substitution and recovery effect.
Źródło:
Acta Physica Polonica A; 2015, 128, 5; 845-848
0587-4246
1898-794X
Pojawia się w:
Acta Physica Polonica A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Footprint areas of pollen from alder (Alnus) and birch (Betula) in the UK (Worcester) and Poland (Wroclaw) during 2005–2014
Obszary źródłowe pyłku olszy (Alnus) i brzozy (Betula) w Wielkiej Brytanii (Worcester) i Polsce (Wrocław), w latach 2005–2014
Autorzy:
Skjoth, C.A.
Bilinska, D.
Werner, M.
Malkiewicz, M.
Adams-Groom, B.
Kryza, M.
Drzeniecka-Osiadacz, A.
Powiązania:
https://bibliotekanauki.pl/articles/27458.pdf
Data publikacji:
2015
Wydawca:
Polskie Towarzystwo Botaniczne
Tematy:
footprint
pollen
alder
Alnus
birch
Betula
Worcester
Polska
Wroclaw city
2005–2014 period
climate
seasonality
source
Opis:
In this study we analyzed daily pollen concentrations of Alnus spp. and Betula spp. from Worcester, UK and Wrocław, Poland. We analyzed seasonality, annual pollen index and footprint areas for the observed pollen concentrations by using the trajectory model hybrid single particle Lagrangian integrated trajectory (HYSPLIT). We examined 10 years of data during the period 2005–2014 and found substantial differences in the seasonality, pollen indices and footprint areas. For both genera, concentrations in Wrocław are in general much higher, the seasons are shorter and therefore more intense than in Worcester. The reasons appear to be related to the differences in overall climate between the two sites and more abundant sources in Poland than in England. The footprint areas suggest that the source of the pollen grains are mainly local trees but appear to be augmented by remote sources, in particular for Betula spp. but only to a small degree for Alnus spp. For Betula spp., both sites appear to get contributions from areas in Germany, the Netherlands and Belgium, while known Betula spp. rich regions in Russia, Belarus and Scandinavia had a very limited impact on the pollen concentrations in Worcester and Wrocław. Substantial and systematic variations in pollen indices are seen for Betula spp. in Wrocław with high values every second year while a similar pattern is not observed for Worcester. This pattern was not reproduced for Alnus spp.
Praca dotyczy dobowych stężeń pyłku olszy (Alnus spp.) oraz brzozy (Betula spp.) notowanych w Worcester (Wielka Brytania) oraz we Wrocławiu (Polska). Przeanalizowano sezonowość, indeks pyłkowy oraz obszary źródłowe pyłku przy zastosowaniu modelu HYSPLIT (hybrid single particle Lagrangian integrated trajectory model). W badaniu uwzględniono dane pomiarowe z okres 10 lat (2005–2014). Zaobserwowano istotne różnice w sezonowości, indeksie pyłkowym oraz obszarach źródłowych dla dwóch analizowanych lokalizacji. Zarówno dla olszy, jak i dla brzozy, stężenia pyłku są na ogół znacznie wyższe i sezon pyłkowy jest krótszy we Wrocławiu, stąd też jest on bardziej intensywny, niż w Worcester. Wynika to najprawdopodobniej z różnic w warunkach klimatycznych pomiędzy dwoma stacjami i z większej liczby lokalnych źródeł pyłku w Polsce niż w Anglii. Obliczenia przeprowadzone z modelem HYSPLIT wskazują, że źródłem ziaren pyłku są głównie drzewa lokalne, ale zaznacza się również rola transportu odległego, ale w szczególności w przypadku pyłku brzozy, a tylko w niewielkim stopniu w przypadku olszy. W przypadku brzozy, na stężenie pyłku notowanego w obu stacjach istotnie wpływa pyłek pochodzący z obszaru Niemiec, Holandii i Belgii, podczas gdy powszechnie znane obszary źródłowe w Rosji, Białorusi i Skandynawii mają bardzo ograniczony wpływ na stężenie pyłku w Worcester i we Wrocławiu. Ponadto zaobserwowano wyraźne, systematyczne zróżnicowanie indeksu pyłkowego brzozy we Wrocławiu, z wysokimi wartościami występującymi co drugi rok. Podobna zależność nie jest obserwowana dla Worcester. Wyraźnych zróżnicowań indeksu pyłkowego pomiędzy latami nie notowano dla olszy w żadnej z lokalizacji.
Źródło:
Acta Agrobotanica; 2015, 68, 4
0065-0951
2300-357X
Pojawia się w:
Acta Agrobotanica
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Numeryczne modelowanie mostków cieplnych a projektowe zapotrzebowanie na ciepło w lokalu mieszkalnym
Numerical modelling of thermal bridges versus design heat load in flat
Autorzy:
Werner-Juszczuk, A. J.
Powiązania:
https://bibliotekanauki.pl/articles/404304.pdf
Data publikacji:
2015
Wydawca:
Polskie Towarzystwo Symulacji Komputerowej
Tematy:
MEB
liniowy współczynnik przenikania ciepła
projektowe obciążenie cieplne
BEM
linear thermal transmittance
design heat load
Opis:
Przedstawiono obliczenia projektowego obciążenia cieplnego w lokalu mieszkalnym w budynku wielorodzinnym w trzech wariantach: z uwzględnieniem przybliżonych wartości współczynników przenikania ciepła liniowych mostków cieplnych wg PN-EN ISO 14683:2008, z uwzględnieniem wartości z katalogu mostków cieplnych oraz przy wykorzystaniu obliczeń numerycznych wykonanych przy użyciu autorskiego programu komputerowego, bazującego na algorytmie metody elementów brzegowych (MEB). Określono wpływ poszczególnych metod na całkowite projektowe straty ciepła w lokalu mieszkalnym.
The results of calculation of design heat load in flat in residential building are presented. Calculation was performed allowing of approximate values of linear thermal transmittance determined with PN-EN ISO 14683:2008, allowing of values from catalogue of thermal bridges and values determined with the use of authoring computer program, basing on boundary element method (BEM) algorithm. The effect of each method on overall design heat loses in flat was determined.
Źródło:
Symulacja w Badaniach i Rozwoju; 2015, 6, 1; 45-56
2081-6154
Pojawia się w:
Symulacja w Badaniach i Rozwoju
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Ocena ryzyka wystąpienia kondensacji pary wodnej na powierzchni ściany klatki schodowej przy wykorzystaniu MEB
Estimation of risk of surface condensation at staircase wall with BEM
Autorzy:
Werner-Juszczuk, A. J.
Rynkowski, P.
Powiązania:
https://bibliotekanauki.pl/articles/404256.pdf
Data publikacji:
2015
Wydawca:
Polskie Towarzystwo Symulacji Komputerowej
Tematy:
MEB
kondensacja powierzchniowa
izolacja cieplna
BEM
surface condensation
thermal insulation
Opis:
W pracy przeprowadzono symulację rozkładu temperatury w miejscu połączenia ściany klatki schodowej ze stropem w wariancie z izolacją i bez izolacji w celu określenia ryzyka wystąpienia powierzchniowej kondensacji pary wodnej i określenia zasadności izolacji ścian pomiędzy klatką schodową a lokalem mieszkalnym. Przyjęto różne wartości temperatury oraz wilgotności względnej powietrza wewnętrznego. Obliczenia wykonano za pomocą autorskiego programu komputerowego wykorzystującego algorytm MEB do rozwiązania ustalonego procesu przewodzenia ciepła w obszarach wielospójnych.
In the paper, the temperature distribution in staircase wall – floor junction is determined in order to estimate the risk of surface condensation both with the necessity of insulation of staircase wall. The results were achieved for wall with and without insulation and for various conditions of inner temperature and relative humidity. The simulation was performed with the use of authoring program, assigned for solving the steady heat transfer problems in multi-regions.
Źródło:
Symulacja w Badaniach i Rozwoju; 2015, 6, 1; 57-65
2081-6154
Pojawia się w:
Symulacja w Badaniach i Rozwoju
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Separation of nanoparticles and nanodroplets from air using fibrous filters
Autorzy:
Werner, Ł.
Jackiewicz, A.
Powiązania:
https://bibliotekanauki.pl/articles/115576.pdf
Data publikacji:
2015
Wydawca:
Fundacja na Rzecz Młodych Naukowców
Tematy:
electrets
fibrous filters
filtration
nanodroplets
nanoparticles
elektrety
filtry włókniste
filtrowanie
nanocząstki
Opis:
Separation of particles from gas stream is of great importance in many areas of human life. Air filtering materials have wide applications. They are used inter alia in ventilation and air conditioning systems, in cars to reduce emission from diesel engines, in the device of everyday use (e.g. vacuum cleaner), as a personal protective equipment for example to avoid inhalation hazardous dust from industrial processes. Small airborne particles can cause a variety problems for human health. Long exposure to particles of submicron- and nano-sized has been related to higher death rates due to lung cancer and cardiopulmonary illness. The main object of this study was to investigate filtration efficiency of oil nanodroplets (DEHS di-ethylhexyl sebacate) and salt nanoparticles (KCl) from air using fibrous polypropylene media made by melt-blown technique. Fibrous filters are relatively inexpensive to fabricate and what is the most important they are high efficient with simultaneous low flow resistance. Three types of non-wovens having various morphology with different average fiber diameter were tested. The tests show that both KCl solid nanoparticles and DEHS nano oil-mist can be efficiently separate from the air using melt-blown fibrous materials. Moreover these filters have been also electrically charged by corona discharge. The filtration efficiency of charged filters (electrets) was compared with efficiency of uncharged (mechanicals) samples. Results showed significant increase in filtration efficiency for the filters with electric charge compared with uncharged ones.
Źródło:
Challenges of Modern Technology; 2015, 6, 3; 15-19
2082-2863
2353-4419
Pojawia się w:
Challenges of Modern Technology
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies