Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "Waheed, M. A." wg kryterium: Autor


Wyświetlanie 1-5 z 5
Tytuł:
Analytical investigation of heat transfer in a moving convective porous fin with temperature dependent thermal conductivity and internal heat generation
Autorzy:
Sobamowo, M. G.
Waheed, M. A.
Powiązania:
https://bibliotekanauki.pl/articles/1031762.pdf
Data publikacji:
2020
Wydawca:
Przedsiębiorstwo Wydawnictw Naukowych Darwin / Scientific Publishing House DARWIN
Tematy:
Convective fin
Differential transformation method
Moving fin
Porous Fin
Thermal analysis
Opis:
In the present study, thermal performance of a rectangular moving porous fin with temperature dependent thermal conductivity and internal heat generation are analyzed the differential transformation method. The developed approximate analytical solutions are used to investigate the effects of thermal –geometric and thermo-physical fin parameters such as the Peclet number, thermal conductivity parameter, convection parameter, porosity parameter, Internal heat generation parameter on the dimensionless temperature distribution and heat transfer rate are discussed. From the results, it is found that increase in porosity and convective parameters, the rate of heat transfer from the fin increases and consequently improve the efficiency of the fin. Also, the values of the temperature distribution in the fin increases as the Peclet number increases. However, as thermal conductivity and the internal heat generation increase, the rate of heat transfer from the fin decreases. The analytical solution is found to be in good agreement with the direct numerical solution.
Źródło:
World Scientific News; 2020, 150; 1-21
2392-2192
Pojawia się w:
World Scientific News
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Effects of Internal Heat Generation on the Thermal Stability of a Porous Fin
Autorzy:
Sobamowo, M. G.
Jayesimi, L. O.
Waheed, M. A.
Powiązania:
https://bibliotekanauki.pl/articles/1031875.pdf
Data publikacji:
2020
Wydawca:
Przedsiębiorstwo Wydawnictw Naukowych Darwin / Scientific Publishing House DARWIN
Tematy:
Differential Transformation Method
Porous Fin
Temperature-Dependent Internal Heat Generation
Thermal analysis
Thermal performance
Opis:
In this study, the effects of internal heat generation on thermal stability of porous fin is theoretical investigated using differential transform method. The parametric studies reveal increase in the internal heat generation leads to increase in the value or the range of the thermal stability of the fin. The internal heat generation can be used to control the thermal instability in the fin. Also, as the porosity parameter increase, the rate of heat transfer from the base of the fin and consequently improve the efficiency of the fin increase. However, a high value or an excessive internal heat generation results in an undesirable situation where some of the heat energy cannot escape to the sink and instead ends up flowing into the prime surface and the fin tends to store heat rather than dissipating it. This scenario defeats the prime purpose of the cooling fin. Therefore, the operational parameters must be carefully selected to ensure that the fin retains its primary purpose of removing heat from the primary surface.
Źródło:
World Scientific News; 2020, 149; 110-127
2392-2192
Pojawia się w:
World Scientific News
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Chebyshev Spectral Collocation Method to Micropolar Fluid Flow through a Porous Channel driven by Suction/Injection with High Mass Transfer
Autorzy:
Jayesimi, L. O.
Sobamowo, M. G.
Akinshilo, A. T.
Waheed, M. A.
Powiązania:
https://bibliotekanauki.pl/articles/1030143.pdf
Data publikacji:
2020
Wydawca:
Przedsiębiorstwo Wydawnictw Naukowych Darwin / Scientific Publishing House DARWIN
Tematy:
Chebyshev spectral collocation method
Mass Transfer
Micropolar fluids
Porous media
Opis:
This paper presents the application of Chebyshev spectral collocation method to flow analysis of a micropolar fluid conveyed through porous channel driven by suction or injection with high mass transfer. Effects of flow and rotation parameters such as Reynolds number and micro rotation parameters on the flow characteristics of the micropolar fluid are investigated using the developed approximate analytical solutions through the method. Comparing the results of the numerical solutions obtained in this study with the other results of the other methods in literature, very good agreements are established. The results obtained from this work can be used to further the study of the behavior of micropolar fluids in applications such as lubricants, blood flow porous media, micro channels and flow in capillaries.
Źródło:
World Scientific News; 2020, 143; 39-52
2392-2192
Pojawia się w:
World Scientific News
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Assessment of the risk for human health of Enterovirus and Hepatitis A virus in clinical and water sources from three metropolitan cities of Pakistan
Autorzy:
Ahmad, T.
Adnan, F.
Nadeem, M.
Kakar, S.J.
Anjum, S.
Saad, A.
Waheed, A.
Arshad, N.
Powiązania:
https://bibliotekanauki.pl/articles/2081926.pdf
Data publikacji:
2018
Wydawca:
Instytut Medycyny Wsi
Tematy:
epidemiology
Enterovirus (EntV)
HAV
PCR
virology
Opis:
Introduction. Molecular studies have confirmed the silent circulation of enterovirus (EntV) and hepatitis A virus in the environment, even in the absence of clinical manifestation. Viral pathogens are among the major causes of disease outbreaks, particularly in the bigger cities and both in the developed and underdeveloped nations. Materials and method. Between June 2016 – June 2017, 97 samples of drinking water, river water polluted with sewage and blood were selected and obtained from high risk communities in Pakistan. Negatively charged membrane filters were used to concentrate the virus, followed by the use of specific PCR primers set for quick identification of the waterborne viruses. Results. Enteroviruses were recovered from 40%, 28.57% and 33.33% of river water polluted with sewage samples in Lahore, Islamabad and Rawalpindi, respectively, while the presence of 13.13% and 11.76% of viral load was also confirmed in the drinking water of Lahore and Rawalpindi, respectively. A high prevalence of HAV (12.5% and 21.05%) was also verified in the clinical samples. Phylogenetic analysis indicated close resemblance of HAV isolates with the Indian strains. This study is the first ever comparative analysis of the EntV and HAV isolated from environmental samples and clinical specimen on a molecular level. Conclusions. The parallel surveillance of EntV and HAV in the river water polluted with sewage, and clinical samples is quite helpful for controlling and reducing the disease burden of the waterborne illnesses.
Źródło:
Annals of Agricultural and Environmental Medicine; 2018, 25, 4; 708-713
1232-1966
Pojawia się w:
Annals of Agricultural and Environmental Medicine
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Incidence and molecular characterization of extended-spectrum beta-lactamase (ESBL)-producing Salmonella enterica and Escherichia coli of avifauna origin in Pakistan
Autorzy:
Saeed, M.A.
Waheed, U.
Ehtisham-ul-Haque, S.
Khan, A.U.
Kashif, M.
Qamar, M.F.
Ghafoor, A.
Saqlain, M.
Asghar, J.
Powiązania:
https://bibliotekanauki.pl/articles/16647457.pdf
Data publikacji:
2023
Wydawca:
Polska Akademia Nauk. Czasopisma i Monografie PAN
Tematy:
ESBL
genotypic characterization
Salmonella enterica
Escherichia coli
avifauna
Pakistan
Opis:
Members of Enterobacteriaceae are known to produce extended-spectrum beta-lactamases (ESBL) which hydrolyze the beta-lactam group of antibiotics. The existence of ESBL-producing Salmonella enterica (S. enterica) and Escherichia coli (E. coli) harbored by urban avifauna was investigated in this study. Dropping samples (n= 180) were collected from six different bird species in the district Jhang, Punjab province, Pakistan. Isolation and identification of ESBL isolates were made by using cefotaxime- (4 mg/L) supplemented MacConkey agar and double disc synergy test (DDST). Polymerase chain reaction (PCR) was performed for the detection of four different ESBL genes including bla CTX-M, bla TEM, bla SHV and bla OXA. A total of 42.69% isolates were confirmed as ESBL via DDST including 30.64% S. enterica and 49.54% E. coli. The incidence of ESBL S. enterica and ESBL E. coli was found highest in egret (Ardea alba) and pigeon (Columba livia) as 64.28% and 78.95%, respectively. The bla CTX-M gene was detected in 57.89% and 64.81% of isolates of S. enterica and E. coli, respectively. Among other genes in S. enterica and E. coli, bla TEM (21.05%, 20.4%); bla SHV (15.78%, 9.26%), and bla OXA (5.26%, 5.56%) were detected, respectively. All of the tested isolates were found resistant to at least one of the thirteen antimicrobial agents except meropenem. To the best of our knowledge, this is the first study reporting the incidence and genetic diversity of ESBL bacteria associated with urban avifauna in Pakistan. The urban avifauna can serve as a potential subject of bio-surveillance to monitor the emergence of antimicrobial-resistant bacteria.
Źródło:
Polish Journal of Veterinary Sciences; 2023, 26, 1; 47-55
1505-1773
Pojawia się w:
Polish Journal of Veterinary Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-5 z 5

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies