Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "Węgrzyński, Wojciech." wg kryterium: Autor


Wyświetlanie 1-7 z 7
Tytuł:
Can smoke control become smart?
Autorzy:
Węgrzyński, Wojciech
Powiązania:
https://bibliotekanauki.pl/articles/231504.pdf
Data publikacji:
2018
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
dymoszczelność
system kontroli dymu
system inteligentny
czujnik dymu
bezpieczeństwo pożarowe
smoke control
smoke control system
smart system
smoke sensor
fire safety
Opis:
Smoke control solutions are used to maintain tenable conditions in buildings, enabling evacuation process, rescue operations and reducing the thermal stress on the building structure. For last 50-years the design process of such solutions did not significantly change – a required volumetric capacity is calculated with theoretical and empirical models, and further, mechanical design is prepared to deliver this capacity. In this paper, a new approach – “smart smoke control” is introduced, as a system that adapts the performance parameters based on the momentary measurements of temperature in the building. The system follows the growth and decay of fire in the building, which allows optimization of its mechanical parameters, and provides substantial increase in the performance. This paper provides a discussion on traditional and new concepts in smoke control, and defines areas, in which a paradigm shift must occur, to enable widespread adoption new and more efficient solutions. The paper does also refer to previous proof of concept studies, presenting the preliminary assessment of the performance of a smart smoke control system.
Źródło:
Archives of Civil Engineering; 2018, 64, 3; 201-208
1230-2945
Pojawia się w:
Archives of Civil Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wentylacja pożarowa tuneli drogowych
Smoke control in road tunnels
Autorzy:
Węgrzyński, Wojciech
Powiązania:
https://bibliotekanauki.pl/articles/24024800.pdf
Data publikacji:
2022
Wydawca:
Stowarzyszenie Inżynierów i Techników Komunikacji Rzeczpospolitej Polskiej
Tematy:
pożar
dym
tunel
wentylacja pożarowa
wentylacja wzdłużna
fire
smoke
tunnel
smoke control
longitudinal ventilation
Opis:
W artykule omówiono stan prawny oraz przyjęte praktyki inżynierskie w zakresie projektowania systemów wentylacji pożarowej tuneli drogowych. Omówiono różnice w działaniu systemów wzdłużnych, półpoprzecznych oraz poprzecznych, jak również przybliżono cechy naturalnej wentylacji tuneli. W odniesieniu do oceny skuteczności działania systemów przedstawiono metodę obliczeniowej mechaniki płynów CFD, a w odniesieniu do czynności odbiorowych przedstawiono metodę praktycznego sprawdzenia skuteczności wentylacji w próbach z gorącym dymem.
The paper covers the legal basis and the current engineering practice in the design of smoke control system of road tunnels. The paper highlights the differences in performance of longitudinal, semi-transversal and transversal systems, as well as main aspects of operation of the natural ventilation. In relation to the design stage, Computational Fluid Modelling is presented as the tool of choice for system performance verification. Hot smoke tests are introduced as a method for practical verification of the system during the commissioning stage.
Źródło:
Drogownictwo; 2022, 7-8; 271--276
0012-6357
Pojawia się w:
Drogownictwo
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wpływ układu przegród w budynku na przepływ dymu w warunkach pożaru
Impact of building partitions on the flow of smoke in fire
Autorzy:
Węgrzyński, Wojciech
Fangrat, Jadwiga
Lipecki, Tomasz
Mizieliński, Bogdan
Powiązania:
https://bibliotekanauki.pl/books/2191441.pdf
Data publikacji:
2021
Wydawca:
Instytut Techniki Budowlanej
Opis:
Monografia obejmuje zagadnienia związane z niewymuszonym przepływem dymu przez układy przegród budowlanych w wielkokubaturowych obiektach budowlanych, co ma praktyczne znaczenie w projektowaniu systemów wentylacji pożarowej. Skuteczny system wentylacji musi odbierać każdy przepływ dymu mający miejsce w budynku – a zatem istnieje bezpośrednie powiązanie pomiędzy parametrami systemu wentylacji, poziomem bezpieczeństwa w obiekcie budowlanym oraz układem przegród budowlanych, jakie na swojej drodze pokonuje dym. Istniejące modele analityczne przepływu dymu uwzględniają architekturę obiektu jako jeden z warunków brzegowych. Jak pokazują prace walidacyjne, prowadzone również przez Autora, to uwzględnienie jest prawidłowe tylko dla wąskiego zakresu zmienności wymiarów przegród, bliskich konfiguracji eksperymentalnej, będącej odniesieniem dla poszczególnych modeli. Z uwagi na powyższe, w modelach zawarto duże marginesy bezpieczeństwa – często bezzasadne, podnoszące koszty instalacji niewspółmiernie do wpływu tego przewymiarowania na bezpieczeństwo użytkowników budynku. Rozważania prowadzone w monografii ograniczono do wielkokubaturowego obiektu handlowego, w którym znajdują się lokale handlowe i pasaż handlowy. Najważniejszym wnioskiem płynącym z badań opisanych w monografii jest możliwość znaczącego podniesienia bezpieczeństwa pożarowego użytkowników lokali handlowych poprzez zwiększenie wymiarów otworów wejściowych do tych lokali. Przeprowadzone badania wskazują, że zwiększenie wejścia generuje mniejszy koszt w odniesieniu do wymiarowania systemu wentylacji, niż wcześniej sugerowano. Wskazuje to na możliwość efektywnego ekonomicznie podniesienia poziomu bezpieczeństwa pożarowego w obiekcie poprzez zmianę sposobu kształtowania przegród budowlanych.
The dissertation discusses the phenomena related to the natural flow of smoke, through partitions of a large volume building, which is of great importance to the design of Smoke and Heat Exhaust Ventilation Systems (SHEVS). The SHEVS must be able to remove the smoke from any source of fire within the building – which means that the compartmentation of the building, the level of fire safety and the SHEVS performance are all connected to each other. Existing analytical methodologies used in the estimation of the mass of smoke that flows through the building, use the description of the compartmentation as its boundary condition. Validation work on these methods carried also by the Author of this thesis, shows that these methods are valid only in the narrow range of the size of partitions or openings – close to the setup of experiments from which these methods originate. This leads to inclusion of large safety margins hidden in the calculation methods, which often are unjustified and increase the cost of safety features of the building inadequately to the gain in fire safety they provide. The research described in this work is limited to a large volume shopping mall, consisting of individual shops and a mall area. Theoretical fire is positioned within a shop and the smoke flows to the mall area through the opening in the storefront. The flow is limited by partitions – vertical partition (referred to as „downstand”) in the storefront, and a projecting balcony inside the mall. After passing these partitions, the smoke can flow directly into the smoke reservoir, from which it is removed. The research carried by the Author differs from other experiments by the location of measurement plane. The research was carried with the use of Computational Fluid Dynamics (CFD) method and with the use of Froude-number based physical modelling in 1 : 10th scale. The author investigated the influence of following partitions and openings on the flow of smoke within the building: dimensions of the shop, width, and height of the opening in a storefront, the existence of a downstand at the storefront and the depth of projecting balcony. The results of the research shows that existing description of how building partitions influence the flow of smoke. Good agreement between experiments and existing models was found only for a narrow range of the dimensions of various partitions. Use of downstand or balcony flow coefficients, a common simplification used in engineering methods, was correct only for averaged results of the experiments. The averaged value had a large standard deviation, which means that in practical engineering these values should not be used, as it may lead to a large error. The performed experiments also have shown, that some technical solutions, such as channeling screens, do not have an as big influence on the fire safety, as previously attributed. A smoke flow in all directions was observed, when the balcony was unequipped with channeling screens, but as estimated, this flow did not cause any significant danger to the building. The most important conclusion of this thesis is, that it is possible to increase the level of fire safety inside a shopping unit, by increasing the dimensions of its opening. At the same time, this increase has a lesser impact on the dimensioning of SHEVS, than previously attributed. This leads to a conclusion, that this increase of fire safety within the building may require a large change in dimensioning of SHEVS, and thus not generate additional cost.
Dostawca treści:
Biblioteka Nauki
Książka
Tytuł:
Characteristic velocity of strong wind for wind engineering purposes
Prędkość charakterystyczna silnego wiatru do celów inżynierii wiatrowej
Autorzy:
Lipecki, Tomasz
Gaczek, Mariusz
Goliger, Adam
Kimbar, Grzegorz
Węgrzyński, Wojciech
Powiązania:
https://bibliotekanauki.pl/articles/27312129.pdf
Data publikacji:
2023
Wydawca:
Polska Akademia Nauk. Czasopisma i Monografie PAN
Tematy:
prędkość wiatru
prędkość charakterystyczna
model Gumbela
wartość ekstremalna uogólniona
rozkład Pareto uogólniony
mapa wietrzności
norma
estymator liniowy nieobciążony najlepszy
characteristic velocity
wind velocity
Gumbel model
generalized extreme value
generalized pareto distribution
wind map
wind code
best linear unbiased estimator
Opis:
Eurocode standard recommends using fundamental basic wind velocity (characteristic velocity) as the design value in civil engineering. There are different approaches to estimate this value depending on the climate features of the given area and the quality of environmental data. The estimation of the characteristic value requires statistical analysis of historical data regarding wind velocities measured throughout the country at meteorological stations. The results of the analysis are probability density distributions of this random variable for each meteorological station. On this basis, values of characteristic wind velocity with a mean return period of 50 years are determined. The zones with uniform velocities are delineated on the map of the country. In the case of Poland the last evaluation of wind zones took place over 15 years ago. Higher quality of measurement data on the one hand, and the introduction of the second generation of Eurocode standards on the other hand, create a need to check and update these zones. This work presents theoretical basis for the estimation of characteristic values of random variables in the context of wind velocity, comprehensively reviews practical methods used for this purpose and summarizes current situation in Poland, finally discusses the issues related to the heterogeneity of wind data, illustrating them with an example.
Eurokod zaleca stosowanie podstawowej bazowej prędkości wiatru (prędkości charakterystycznej) jako wartości projektowej w inżynierii lądowej. Istnieją różne metody szacowania tej wartości, zależne od cech klimatycznych danego obszaru oraz jakości rejestrowanych danych środowiskowych. Oszacowanie wartości charakterystycznej wymaga analizy statystycznej danych historycznych na temat prędkości wiatru mierzonej na stacjach meteorologicznych na terenie całego kraju. Wynikiem analizy jest rozkład gęstości prawdopodobieństwa i w konsekwencji wartość charakterystyczna prędkości wiatru w danej lokalizacji. W normach projektowych, przeważnie jest to prędkość o tzw. okresie powrotu wynoszącym 50 lat. Końcowym efektem jest wyznaczenie na mapie kraju stref o jednakowych prędkościach wiatru. W przypadku Polski ostatnia aktualizacja stref wiatrowych miała miejsce ponad 15 lat temu. Znacznie dłuższe okresy pomiarowe i dobra jakość danych rejestrowanych na stacjach w ostatnich latach oraz wprowadzenie w niedalekiej przyszłości drugiej generacji norm Eurokod stwarza potrzebę sprawdzenia tych stref i ewentualnej ich korekty. W pracy przedstawiono podstawy teoretyczne estymacji wartości charakterystycznych zmiennych losowych w kontekście prędkości wiatru, dokonano kompleksowego przeglądu praktycznych metod stosowanych w tym celu oraz podsumowano obecną sytuację w Polsce. Omówiono również zagadnienia związane z niejednorodności danych wiatrowych rejestrowanych na stacjach meteorologicznych, ilustrując je przykładem.
Źródło:
Archives of Civil Engineering; 2023, 69, 3; 217--237
1230-2945
Pojawia się w:
Archives of Civil Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Investigation of low-temperature plasmas formed in low-density gases surrounding laser-produced plasmas
Autorzy:
Majszyk, Mateusz
Bartnik, Andrzej
Skrzeczanowski, Wojciech
Fok, Tomasz
Węgrzyński, Łukasz
Szczurek, Mirosław
Fiedorowicz, Henryk
Powiązania:
https://bibliotekanauki.pl/articles/2202566.pdf
Data publikacji:
2023
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
extreme ultraviolet
EUV
laser plasma
low pressure
photoionization
plasma
soft X-ray
SXR
Opis:
Low-temperature plasma production is possible as a result of photoionization using high-intensity extreme ultraviolet (EUV) and soft X-ray (SXR) pulses. Plasma of this type is also present in outer space, e.g., aurora borealis. It also occurs when high-velocity objects enter the atmosphere, during which period high temperatures can be produced locally by friction. Low-temperature plasma is also formed in an ambient gas surrounding the hot laser-produced plasma (LPP). In this work, a special system has been prepared for investigation of this type of plasma. The LPP was created inside a chamber fi lled with a gas under a low pressure, of the order of 1–50 mbar, by a laser pulse (3–9 J, 1–8 ns) focused onto a gas puff target. In such a case, the SXR/EUV radiation emitted from the LPP was partially absorbed in the low-density gas. In this case, high- and low-temperature plasmas (Te ~100 eV and ~1 eV, respectively) were created locally in the chamber. Investigation of the EUV-induced plasmas was performed mainly using spectral methods in ultraviolet/visible (UV/VIS) light. The measurements were performed using an echelle spectrometer, and additionally, spatial–temporal measurements were performed using an optical streak camera. Spectral analysis was supported by the PGOPHER numerical code.
Źródło:
Nukleonika; 2023, 68, 1; 11--17
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Population diversity in ant-inspired optimization algorithms
Autorzy:
Byrski, Aleksander
Węgrzyński, Krzysztof
Radwański, Wojciech
Starzec, Grażyna
Starzec, Mateusz
Bargiel, Monika
Urbańczyk, Aleksandra
Kisiel-Dorohinicki, Marek
Powiązania:
https://bibliotekanauki.pl/articles/2097962.pdf
Data publikacji:
2021
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie. Wydawnictwo AGH
Tematy:
ant colony optimization
diversity measuring
exploitation and exploration balance
metaheuristics
Opis:
Measuring the diversity in evolutionary algorithms that work in real-value search spaces is often computationally complex, but it is feasible; however, measuring the diversity in combinatorial domains is practically impossible. Nevertheless, in this paper we propose several practical and feasible diversitymeasurement techniques that are dedicated to ant colony optimization algorithms, leveraging the fact that we can focus on a pheromone table even though an analysis of the search space is at least an NP problem where the direct outcomes of the search are expressed and can be analyzed. Besides sketching out the algorithms, we apply them to several benchmark problems and discuss their efficacy.
Źródło:
Computer Science; 2021, 22 (3); 297-320
1508-2806
2300-7036
Pojawia się w:
Computer Science
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-7 z 7

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies