Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "Tuğrul, A." wg kryterium: Autor


Tytuł:
Investigation of natural radioactivity of surface soil samples in the vicinity of Edirne-Turkey
Autorzy:
Zaim, N.
Tugrul, A.
Atlas, H.
Buyuk, B.
Demir, E.
Baydogan, N.
Altınsoy, N.
Powiązania:
https://bibliotekanauki.pl/articles/1070463.pdf
Data publikacji:
2016-07
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Tematy:
07.88.+y
89.60.-k
Opis:
The study was carried out to determine radioactivity concentrations in surface soil samples of the city of Edirne in connection with the potential radiological hazards due to Chernobyl event. The natural radionuclide ((226)Ra, (232)Th and (40)K) contents were determined for nine different locations in nine different towns of the Edirne city. Radiation levels were measured. Natural beta-ray activity was also determined for the same locations. The average estimated activity values were determined and compared with reported values for other cities in Turkey and also for many countries of the world. The studied areas do not pose radiological risks to the inhabitants due to harmful effects of the ionizing radiation from the natural radioactivity of the soil.
Źródło:
Acta Physica Polonica A; 2016, 130, 1; 64-67
0587-4246
1898-794X
Pojawia się w:
Acta Physica Polonica A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Assessment of patient dose by positron emission tomography (PET) and medical internal dose (MIRD) methods
Autorzy:
Yilmaz, G.
Tugrul, A.
Demir, M.
Yasar, D.
Demir, B.
Powiązania:
https://bibliotekanauki.pl/articles/1068158.pdf
Data publikacji:
2016-07
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Tematy:
87.57.uk
87.53.Bn
Opis:
Dynamic experiments cannot be observed easy on patients for determination of dosimetry in human PET studies dosimeter studies. In this study, it is aimed to estimate dose amount absorbed by some critical organs (e.g. bladder, lung, thyroid and ovary) by using a developed phantom. The phantom was improved as an original anthropomorphic whole body phantom which has been arranged with dynamic system. Therefore, organ absorbed doses by applying of fluorine-18-fluorodeoxyglucose in PET studies and was observed by using the phantom, while TLD dosimeters were used for determination of internal absorbed doses. In medical physics, the accuracy of absorbed dose resulting from radiopharmaceutical application was determined by the medical internal radiation dose method that depends theoretically on the cumulated activity of the source organs and their mass. The MIRD calculation was also used for the study and comparatively evaluated with the experimental results which were collected by using improved phantom.
Źródło:
Acta Physica Polonica A; 2016, 130, 1; 90-92
0587-4246
1898-794X
Pojawia się w:
Acta Physica Polonica A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Gamma Attenuation Properties of Some Aluminum Alloys
Autorzy:
Yıldırım, S.
Tugrul, A.
Buyuk, B.
Demir, E.
Powiązania:
https://bibliotekanauki.pl/articles/1188038.pdf
Data publikacji:
2016-04
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Tematy:
25.20.Dc
Opis:
In the present work, several commonly used aluminum alloys were investigated for their protective properties against gamma radiation. The gamma transmission technique was used to study the gamma attenuation behavior of the alloys. Cs-137 (0.662 MeV) and Co-60 (1.25 MeV) gamma radioisotope sources, which have relatively medium and high gamma energy levels, were used as gamma sources. The linear and mass attenuation coefficients of the aluminum alloys were measured. The mass attenuation coefficients of the samples were compared with the theoretical values which were calculated using XCOM computer code. The difference between the experimental and theoretical values was below 5%. In addition half-value layer (HVL) values for the studied aluminum alloys were calculated using the linear attenuation coefficients. The attenuation coefficients of the different aluminum alloys were compared. The biggest HVL was observed for 1050 alloy, for both gamma isotope sources, which means the smallest gamma attenuation capability among the studied alloys. It is concluded that the alloys were applicable for the gamma radiation shielding applications.
Źródło:
Acta Physica Polonica A; 2016, 129, 4; 813-815
0587-4246
1898-794X
Pojawia się w:
Acta Physica Polonica A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
An Investigation on the Mass Attenuation Coefficients of W-VC-C and W-VC-TiC-C Composites for Gamma Radioisotopes
Autorzy:
Tuğrul, A.
Demir, E.
Yılmaz, O.
Sönmez, S.
Öveçoğlu, M.
Büyük, B.
Powiązania:
https://bibliotekanauki.pl/articles/1187451.pdf
Data publikacji:
2016-04
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Tematy:
25.20.Dc
81.05.Mh
Opis:
In this study, tungsten-vanadium carbide-graphite and tungsten-vanadium carbide-titanium carbide-graphite composites (W-VC-TiC-C) which can be used in high-tech equipment were investigated against different gamma radioisotopes. The composite materials were produced via mechanical alloying method in two groups; one of them includes 93% tungsten (W), 6% vanadium carbide (VC) and 1% graphite (C) which was synthesized during three different alloying times (6, 12, 24 hours). Other group of the samples were composited as 91% tungsten, 6% vanadium carbide (VC), 2% titanium carbide (TiC) and 1% graphite (C) which has also three different alloying times (6, 12, 24 hours). Gamma transmission technique was used in the experiments to investigate the gamma attenuation properties of the composite materials. Linear and mass attenuation coefficients of the samples were determined in the experiments and theoretical mass attenuation coefficients were calculated using widely acknowledged XCOM computer code. The experimental mass attenuation coefficients and calculated theoretical results were compared and evaluated with each other. Results showed that gamma attenuation coefficients of the composite materials dependent on alloying time. It can be concluded that increasing the tungsten ratio causes higher linear attenuation coefficient which decreases with increasing gamma energies.
Źródło:
Acta Physica Polonica A; 2016, 129, 4; 724-727
0587-4246
1898-794X
Pojawia się w:
Acta Physica Polonica A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Investigation for Remediation of Selenium Aqueous Environment with Using Organic Pillared Bentonite by Radiotracer Technique
Autorzy:
Tugrul, A.
Haciyakupoglu, S.
Erenturk, S.
Karatepe, N.
Baytas, F.
Baydogan, N.
Altinsoy, N.
Buyuk, B.
Orucoglu, E.
Demir, E.
Camtakan, Z.
Okka, M.
Powiązania:
https://bibliotekanauki.pl/articles/1192490.pdf
Data publikacji:
2015-04
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Tematy:
25.20.Dc
Opis:
In this study remediation of selenium ions from aqueous solutions was investigated using organic pillared bentonite as an adsorbent. Organic pillared bentonite was produced from Resadiye (Tokat, Turkey) bentonite using hexadecylpyridinium chloride and aluminum polyoxy-cations. All the experiments were carried out by tracing with selenium radioisotope. For the production of the radioactive selenium radioisotope, selenium dioxide was irradiated in the central thimble of ITU TRIGA Mark II Training and Research Reactor at Energy Institute of Istanbul Technical University. Radioactivity measurements carried out by the gamma-ray spectroscopy system were used to determine of selenium isotope. The relative importance of test parameters like concentration of adsorbate, pH of the solution and contact time on adsorption performance of organic pillared bentonite for selenium ion was studied. Evaluation of experiments for different parameters showed possibility of remediation of selenium from aqueous media by using organic pillared bentonite.
Źródło:
Acta Physica Polonica A; 2015, 127, 4; 1186-1188
0587-4246
1898-794X
Pojawia się w:
Acta Physica Polonica A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The Chronic Dose Assessment of Three Critical Organs for Liver Scintigraphy with Using Cr-51
Autorzy:
Maranci, Ö.
Tugrul, A.
Powiązania:
https://bibliotekanauki.pl/articles/1031760.pdf
Data publikacji:
2017-09
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Tematy:
Cr-51
dosimetry
phantom
scintigraphy
TRIGA
Opis:
In this study, a dosimetric study was observed by using Cr-51 gamma radioisotope on liver scintigraphy. In this context, the source organ is determined as liver and it is aimed the evaluation of measuring doses from source organ to selected three critical organs (thyroid, gonad, and brain). An antropomorphic torso phantom has been preferred in the experiments. The measurements of critical organs doses were examined for chronic effects. Moreover, the chronic effect of Cr-51 radioisotope on critical organs was determined as cumulative dose. Thermoluminescent dosimeters were used for chronic dose assessment. In the experiments, lithium fluoride (LiF) (TLD-100) detectors were used and they were provided from Turkish Atomic Energy Authority - Cekmece Nuclear Research and Training Center and calibrated in there. Within this study, the evaluation of the cumulative doses by using Cr-51 for three critical organs was observed with an original setup by using anthropomorphic torso phantom experimentally.
Źródło:
Acta Physica Polonica A; 2017, 132, 3; 476-478
0587-4246
1898-794X
Pojawia się w:
Acta Physica Polonica A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Evaluation of Gamma Penetration through Plain Carbon Steels
Autorzy:
Durmaz, H.
Beril Tugrul, A.
Buyuk, B.
Powiązania:
https://bibliotekanauki.pl/articles/1195242.pdf
Data publikacji:
2014-02
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Tematy:
25.20.Dc
Opis:
In this study, 1010, 1040, 1050 and 1090 carbonized steels were investigated against gamma radioisotope sources on their gamma attenuation properties. Co-60, Cs-137 and Ir-192 gamma radioisotopes which are commonly used in industrial applications were used in the experiments. Half-value layers were carried out for studied carbonized steels against all studied gamma radioisotopes. In addition, the linear and mass attenuation coefficients were determined for each carbonized steels at different gamma radioisotope sources. The theoretical mass attenuation coefficients were calculated from XCOM computer code for all samples at specific energies of Co-60, Cs-137 and Ir-192 gamma sources. The theoretical and experimental results were compared with each other.
Źródło:
Acta Physica Polonica A; 2014, 125, 2; 469-472
0587-4246
1898-794X
Pojawia się w:
Acta Physica Polonica A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Assessment on Gamma Attenuation Behavior of W-VC-C and W-VC-TiC-C Composites for Co-60 Radioisotope
Autorzy:
Demir, E.
Tugrul, A.
Sonmez, S.
Ovecoglu, L.
Buyuk, B.
Yilmaz, O.
Powiązania:
https://bibliotekanauki.pl/articles/1031587.pdf
Data publikacji:
2017-09
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Tematy:
attenuation coefficient
Co-60
radiation shielding material
transmission technique
W-VC-C-TiC composite
Opis:
In this study, tungsten-vanadium carbide-graphite (W-VC-C) and tungsten-vanadium carbide-titanium carbide-graphite composite (W-VC-TiC-C) materials were investigated against Co-60 gamma radioisotope. The composite materials which are used in advanced technological studies and high temperature applications in many various fields especially in the areas of fission and fusion armor materials were produced by mechanical alloying method as in two groups. One of them include 93% tungsten (W), 6% vanadium carbide (VC) and 1% graphite (C) also which has three different alloying times (6-12-24 h). Other group of the samples was composed of 91% tungsten, 6% vanadium carbide (VC), 2% titanium carbide (TiC) and 1% graphite (C) also which has three different alloying times (6-12-24 h) and sintered at 1750°C. Co-60 gamma radioisotope source and gamma transmission technique were used in the experiments to investigate the properties of the composite materials. The mass attenuation coefficients of the samples were determined by using experimental results and theoretical mass attenuation coefficients were calculated from XCOM computer code. It can be concluded that increasing the tungsten ratio causes higher mass attenuation coefficient and the composite materials have provided us benefits better than lead for radiation gamma shielding.
Źródło:
Acta Physica Polonica A; 2017, 132, 3; 830-832
0587-4246
1898-794X
Pojawia się w:
Acta Physica Polonica A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Comparison of Radiation Properties of Tungsten and Additive Metal Coatings on 321 Stainless Steel Substrate
Autorzy:
Demir, E.
Karabas, M.
Sonmez, S.
Tugrul, A.
Ovecoglu, M.
Buyuk, B.
Powiązania:
https://bibliotekanauki.pl/articles/1033365.pdf
Data publikacji:
2017-01
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Tematy:
25.20.Dc
81.05.Mh
Opis:
In the present work, the gamma and neutron attenuation behaviors of tungsten, tungsten copper, and tungsten boron-carbide coatings on 321 stainless steel substrate were investigated against Cs-137 and Co-60 gamma radioisotopes and Pu-Be neutron source. The experimental results were compared and evaluated with pure 321 stainless steel to obtain gamma and neutron shielding properties of the coating materials. Tungsten, tungsten copper, and tungsten boron-carbide coatings on 321 stainless steel substrate were fabricated by atmospheric plasma spraying technique. Gamma and neutron transmission technique were used in this study to investigate the radiation behaviors of the coated materials. Linear attenuation coefficients of coated samples were carried out for Pu-Be neutron source. Transmittance values for each specimen were calculated at 0.662 MeV and 1.25 MeV gamma energies. The experimental results were evaluated for radiation shielding properties of the coated samples against gamma and neutron source with pure 321 stainless steel.
Źródło:
Acta Physica Polonica A; 2017, 131, 1; 71-73
0587-4246
1898-794X
Pojawia się w:
Acta Physica Polonica A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Processing, Mechanical and Nuclear Characterization of Boron Carbide Ceramics Consolidated by Spark Plasma Sintering
Autorzy:
Cengiz, M.
Ozer, S.
Buyuk, B.
Tugrul, A.
Yucel, O.
Goller, G.
Sahin, F.
Powiązania:
https://bibliotekanauki.pl/articles/1401969.pdf
Data publikacji:
2015-08
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Tematy:
25.20.Dc
81.20.Ev
Opis:
Boron carbide (B₄C) ceramics were produced by spark plasma sintering technique with 5, 10, 15, and 20 vol.% aluminum (Al) in order to improve sintering behaviours of B₄C ceramics. B₄C ceramics were produced, having square cross-section and 50 × 50 × 5 mm³ dimensions. The sintering process was carried out at different temperatures by applying 40 MPa of pressure with 100°C/min under vacuum. The effects of various amounts of Al additive and sintering temperature on density, vickers hardness, fracture toughness and microstructure were examined. The hardness and fracture toughness of the samples were evaluated by the Vickers indentation technique. Microstructures of the samples were characterized by scanning electron microscopy technique. Fast neutron attenuation properties of the ceramics having highest density were also investigated.
Źródło:
Acta Physica Polonica A; 2015, 128, 2B; B-187-B-189
0587-4246
1898-794X
Pojawia się w:
Acta Physica Polonica A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Urine iodine excretion in patients with papillary thyroid cancer evaluation of the relationship with the presence of BRAF mutation
Autorzy:
Celik, M.
Guldiken, S.
Ayturk, S.
Yilmaz Bulbul, B.
Kucukarda, A.
Can, N.
Tastekin, E.
Sezer, A.
Sut, N.
Tugrul, A.
Gurkan, H.
Tozkir, H.
Demirkan, B.
Powiązania:
https://bibliotekanauki.pl/articles/1192247.pdf
Data publikacji:
2020
Wydawca:
Uniwersytet Warmińsko-Mazurski w Olsztynie / Polskie Towarzystwo Magnezologiczne im. Prof. Juliana Aleksandrowicza
Tematy:
papillary thyroid cancer
BRAF mutation
urine iodine excretion
Opis:
Iodine is an essential element for the production of thyroid hormones. In recent years, it has been suggested that excessive consumption of iodine may play a role in the pathogenesis of papillary thyroid cancer (PTC). In addition, studies have suggested that high iodine consumption is an important risk factor for the formation of a BRAF mutation in the thyroid gland. A prospectively designed study included 132 cases scheduled for thyroidectomy for various reasons. Urine iodine levels of all patients were examined before the operation. The iodine excretion levels of the patients were grouped according to the median urinary iodine concentration determined in community screenings (those with <100 µg L-1 low iodine excretion, those with 100-199 µg L-1 normal iodine excretion, those with 200-299 µg L-1 high iodine excretion). Patients were divided into 3 groups according to the post-operative pathology results. As a result of thyroid histopathology, benign (n: 44), PTC (n: 88) (BRAF (+): 44 and BRAF (-): 44) cases were included in the study. BRAF mutations in patients diagnosed with PTC were evaluated using the “Real Time PCR Melting Curve Analyzer” method. The relationship between urinary iodine excretion levels and clinical, histopathological and BRAF positivity was examined. In our study, no difference was found in urinary iodine excretion between patients with and without PTC. Hashimoto’s thyroiditis was observed more frequently in patients with PTC (p=0.023). In addition, Hashimoto’s thyroiditis was statistically more frequently detected in the BRAF (-) group compared to the BRAF (+) and control group (p=0.034). Despite studies suggesting that high iodine consumption is important in PTC pathogenesis, we did not find a relationship between the mutation and iodine consumption, which plays an important role in the development of PTC.
Źródło:
Journal of Elementology; 2020, 25, 3; 1019-1028
1644-2296
Pojawia się w:
Journal of Elementology
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Comparison of Lead and WC-Co Materials against Gamma Irradiation
Autorzy:
Buyuk, B.
Tugrul, A.
Powiązania:
https://bibliotekanauki.pl/articles/1182923.pdf
Data publikacji:
2014-02
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Tematy:
25.20.Dc
Opis:
According to RoHS (Restriction of Hazardous Substances) directive of European Union it is restricted using lead in many equipment and applications. It is possible to enlarge the restriction of lead usage in some other applications which is including some of nuclear applications in the future. Therefore new materials or systems need to be developed instead of lead as radiation shielding materials and/or collimators. In this study pure tungsten, tungsten carbide-cobalt (WC-Co) materials were investigated against gamma radiation. For gamma radiation Cs-137 and Co-60 gamma radioisotope sources were used. The linear and mass attenuations were calculated. The experimental results were compared with XCOM computer code. Usage possibilities of WC-Co instead of lead in nuclear applications as gamma shielding material were discussed. It has been investigated that the linear gamma attenuation coefficients of lead and WC-Co are very close to each other. Therefore it could be said that WC-Co materials is an alternative promising material which could be used instead of lead as gamma shielding material and/or collimator.
Źródło:
Acta Physica Polonica A; 2014, 125, 2; 423-425
0587-4246
1898-794X
Pojawia się w:
Acta Physica Polonica A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Gamma Attenuation Behavior of h-BN and h-BN-$TiB_2$ Composites
Autorzy:
Buyuk, B.
Beril Tugrul, A.
Okan Addemir, A.
Ay, N.
Powiązania:
https://bibliotekanauki.pl/articles/1287809.pdf
Data publikacji:
2014-02
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Tematy:
25.20.Dc
Opis:
Hexagonal boron nitride (h-BN) and hexagonal boron nitride-titanium diboride (h-BN-$TiB_2$) composites are advanced materials for high-tech applications. They were investigated against gamma radioisotope sources Cs-137 and Co-60 which have gamma peaks 0.662 MeV for Cs-137, and 1.17 and 1.33 MeV for Co-60. Materials have been produced at 1800C temperature in argon atmosphere without pressure during 2 h time. Linear and mass attenuation coefficients were calculated for the materials. Gamma transmission technique was used in the experiments. The experimental investigated mass attenuation coefficients of the materials for Cs-137 and Co-60 gamma radioisotope sources were compared with XCOM computer code. For h-BN-$TiB_2$ composites the ratio of $TiB_2$ in the composites is 55% by weight. So gamma attenuation effects of adding $TiB_2$ to h-BN were discussed. It could be said that adding $TiB_2$ to h-BN increases the linear gamma attenuation of the samples.
Źródło:
Acta Physica Polonica A; 2014, 125, 2; 420-422
0587-4246
1898-794X
Pojawia się w:
Acta Physica Polonica A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Investigation of Behaviour of Titanium Diboride Reinforced Boron Carbide-Silicon Carbide Composites against Cs-137 Gamma Radioisotope Source by Using Gamma Transmission Technique
Autorzy:
Buyuk, B.
Tugrul, A.
Akarsu, A.
Addemir, A.
Powiązania:
https://bibliotekanauki.pl/articles/1490933.pdf
Data publikacji:
2012-01
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Tematy:
25.20.Dc
Opis:
Boron carbide is a material which has wide application areas in industry including nuclear technology. Titanium diboride reinforced boron carbide-silicon carbide composites were studied for searching of the behaviour against the gamma ray. It has been adopted that depending on their properties such improved materials can be used in nuclear technology. For the investigation of the gamma radiation behaviour of these materials, Cs-137 radioisotope was used as gamma source in the experiments which have a single gamma-peak at 0.662 MeV. Gamma transmission technique was used for the measurements. Different reinforcing ratios, titanium diboride reinforced boron carbide-silicon carbide composites were evaluated in relation to gamma transmission and the results of the experiments were interpreted and compared with each other. It could be understood that the increasing ratio of titanium diboride in boron carbide-silicon carbide composites causes higher hardness, strength and linear attenuation coefficient values but decrease the mass attenuation coefficient.
Źródło:
Acta Physica Polonica A; 2012, 121, 1; 135-137
0587-4246
1898-794X
Pojawia się w:
Acta Physica Polonica A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Investigation on the Effects of Boron Carbide Particle Size on Radiation Shielding Properties of Boron Carbide-Titanium Diboride Composites
Autorzy:
Buyuk, B.
Tugrul, A.
Aktop, S.
Addemir, A.
Powiązania:
https://bibliotekanauki.pl/articles/1399664.pdf
Data publikacji:
2013-02
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Tematy:
25.20.Dc
Opis:
Boron carbide is a material which has wide application areas in industry including nuclear technology. Titanium diboride-boron carbide composites which were produced from different boron carbide particle sizes were studied for searching of the behaviour against the gamma ray. Micron size and submicron size boron carbide were used to produce composite materials. The volume of boron carbide and titanium diboride in the composites are 85% and 15%, respectively. For the investigation of the gamma radiation behaviour of these materials, Cs-137 radioisotope was used as gamma source in the experiments which has a single gamma-peak at 0.662 MeV. Gamma transmission technique was used for the measurements. The effects of boron carbide particle size on radiation attenuation of titanium diboride-boron carbide composites were evaluated in relation with gamma transmission and the results of the experiments were interpreted and compared with each other. It could be understood that decrease of particle size of boron carbide in boron carbide-titanium diboride composites causes higher linear and mass attenuation coefficient values. So, submicron size boron carbide used composite materials are more convenient than micron size boron carbide used composite materials as radiation shielding materials for nuclear applications.
Źródło:
Acta Physica Polonica A; 2013, 123, 2; 177-179
0587-4246
1898-794X
Pojawia się w:
Acta Physica Polonica A
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies