Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "Tarasiuk, J." wg kryterium: Autor


Tytuł:
Magnetic Polymer Nanocomposite for Medical Application
Autorzy:
Świętek, M.
Tokarz, W.
Tarasiuk, J.
Wroński, S.
Błażewicz, M.
Powiązania:
https://bibliotekanauki.pl/articles/1197651.pdf
Data publikacji:
2014-04
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Tematy:
82.35.Np
87.85.-d
87.85.Rs
75.75.-c
87.85.J-
87.85.Lf
Opis:
Magnetic sponges derived from biocompatible and resorbable polymers are promising materials for medical applications. These materials have been utilised extensively in research applications for the capture of biomolecules and cells, the construction of tissue scaffolds and in regenerative medicine. The object of this study was a polymer scaffold made of polycaprolactone (PCL) containing a 10 wt% amount of nanomagnetite, manufactured in a two-step method. The porosity and morphological parameters were characterised with the use of μ-computer-aided tomography and scanning electron microscopy. Furthermore, the magnetic properties were evaluated. The obtained results confirmed high porosity and the appearance of randomly oriented pores. Moreover, evaluations of the magnetic properties, of both the magnetite nanopowder and the prepared magnetic nanocomposite, were performed. The tests verified the ferromagnetic character of the materials under investigation.
Źródło:
Acta Physica Polonica A; 2014, 125, 4; 891-894
0587-4246
1898-794X
Pojawia się w:
Acta Physica Polonica A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The comparisons of blood plasma and cerebrospinal fluid S100B protein concentrations in patients with Alzheimer`s disease, amyotrophic lateral sclerosis, and multiple sclerosis
Autorzy:
Tarasiuk, J.
Kapica-Topczewska, K.
Chorąży, M.
Borowik-Zaręba, A.
Mroczko, B.
Kochanowicz, J.
Kułakowska, A.
Powiązania:
https://bibliotekanauki.pl/articles/1918848.pdf
Data publikacji:
2019-08-26
Wydawca:
Uniwersytet Medyczny w Białymstoku
Tematy:
S100
blood
cerebrospinal fluid
Alzheimer's disease
Amyotrophic lateral sclerosis
Multiple sclerosis
Opis:
Introduction:S100 calcium-binding protein B (S100B) is a biochemical marker of astroglial damage. Purpose: To assess the pathophysiological implications of S100B concentrations in blood plasma and cerebrospinal fluid of patients with neurodegenerative central nervous system disorders. Materials and Methods: In this study, we determined and compare S100B concentrations in blood plasma and cerebrospinal fluid obtained from subjects diagnosed with Alzheimer's disease (n=20), amyotrophic lateral sclerosis (n=12), multiple sclerosis (n=40) and the reference group (n=20), using enzyme-linked immunosorbent assay. Results: Concentrations of S100B in plasma collected from patients diagnosed with Alzheimer's disease (252,38±183,50 pg/mL) and multiple sclerosis (164,92±250,14 pg/mL) were above laboratory standards, but in patients with amyotrophic lateral sclerosis (53,96±56,92 pg/mL) and the reference group (2,12 pg/mL) were below laboratory norms (N>75 pg/mL). Concentrations of S100B in plasma collected from patients with Alzheimer's disease (252,38±183,50 pg/mL) were significantly higher than in patients with amyotrophic lateral sclerosis (53,96±56,92 pg/mL) (p<0,029). Concentrations of S100B in CSF collected from the reference group (546,96±236,62 pg/mL) and from patients with Alzheimer's disease (587,53±189,57 pg/mL), amyotrophic lateral sclerosis (404,41±179,56 pg/mL), multiple sclerosis (462,03±146,01 pg/mL) were very similar, and none of pairwise comparisons reached statistical significance. Conclusions: Results of our studies indicate the importance of S100B protein concentration assessment in blood in central nervous system disorders differential diagnostics.
Źródło:
Progress in Health Sciences; 2019, 1; 22-27
2083-1617
Pojawia się w:
Progress in Health Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
X-Rays Response of Diamond Detectors Constructed Using Diamond Layers Produced by Low Power Microwave Chemical Vapor Deposition Reactor
Autorzy:
Kordyasz, A.
Bednarek, A.
Kowalczyk, M.
Tarasiuk, J.
Kulczycka, E.
Teodorczyk, M.
Gajewski, M.
Kordyasz, Ł.
Rowiński, O.
Lamparski, K.
Karwański, Ł.
Lipczewski, T.
Powiązania:
https://bibliotekanauki.pl/articles/1402641.pdf
Data publikacji:
2015-05
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Tematy:
52.75.-d
81.15.Gh
29.40.Vj
07.85.Fv
Opis:
The low power reactor for microwave chemical vapor deposition process is described. The rotating Mo holder of 12 mm diameter and 6 mm height with the diamond substrate was heated by 2.45 GHz microwaves to temperature about 800°C in the range of (1.5-7)% $CH_{4}//H_{2}$ mixture to create plasma at pressure 70 Tr. Stabilization of the holder temperature was performed by optical observation of radiation from the holder followed by adjusting of the magnetron power. Diamond detectors are produced using microwave chemical vapor deposition process grown on single crystal diamond high pressure high temperature Sumimoto substrates, [100] oriented. The response of diamond detectors for X-rays has been measured in the current mode using medical X-rays tube. The linear response of the diamond detector current versus X-ray tube current (dose) is presented.
Źródło:
Acta Physica Polonica A; 2015, 127, 5; 1555-1559
0587-4246
1898-794X
Pojawia się w:
Acta Physica Polonica A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Weryfikacja doświadczalna analizatora jakości energii elektrycznej na statku m/s "Horyzont II"
Experimental verification of electrical power quality analyser on the ship m/s "Horyzont II"
Autorzy:
Tarasiuk, T.
Mindykowski, J.
Powiązania:
https://bibliotekanauki.pl/articles/157618.pdf
Data publikacji:
2003
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
weryfikacja doświadczalna analizatora jakości
analizator jakości energii elektrycznej
experimental verification of electrical power
electrical power quality analyser
Opis:
W pracy przedstawiono strukturę i model fizyczny analizatora jakości energii elektrycznej opracowanego dla potrzeb energetyki okrętowej. Wspomniany model zrealizowany został z wykorzystaniem procesorów sygnałowych i przeszedł z wynikiem pozytywnym badania swoich właściwości w warunkach laboratoryjnych.Ostatecznej weryfikacji walorów użytkowych modelu dokonano na statku szkolno-badawczym Akademii Morskiej w Gdyni m/s "Horyzont II". W pracy przedstawiono wybrane przykłady przeprowadzonych badań.
Ii the paper the structure and physical model of the ships electrical power quality analyser has been presented. The above - mentioned model is based on the digital signals processing and it has been positively tested under the laboratoty conditions. The final verification of the operational properties of this device has been carried out on Gdynia Maritime University training ship m/v "Horizont II".
Źródło:
Pomiary Automatyka Kontrola; 2003, R. 49, nr 1, 1; 31-36
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Kompleksowa automatyzacja i monitorowanie sieci SN kluczowym elementem poprawy niezawodności i ciągłości dostaw energii
Comprehensive automation and monitoring of MV grids as the key element of improvement of energy supply reliability and continuity
Autorzy:
Kubacki, S.
Świderski, J.
Tarasiuk, M.
Powiązania:
https://bibliotekanauki.pl/articles/397655.pdf
Data publikacji:
2012
Wydawca:
ENERGA
Tematy:
elektroenergetyka
sieci inteligentne
sieć średniego napięcia
SAIDI
SAIFI
smart grid
Opis:
Artykuł porusza zagadnienie kompleksowej automatyzacji i monitorowania sieci średniego napięcia (SN) jako kluczowego elementu koncepcji sieci inteligentnej (ang. Smart Grid). Omówiono stan istniejący w zakresie sterowania i monitorowania sieci SN oraz przedstawiono koncepcję rozwiązania dającego możliwość zdalnej, automatycznej rekonfiguracji sieci oraz zapewniającego pełną obserwowalność sieci z poziomu systemu dyspozytorskiego. Szczegółowo omówiono automatyzację przełączeń w sieci SN w celu wyizolowania uszkodzonego odcinka linii i zasilenia w energię elektryczną w chwili wystąpienia awarii możliwie największej liczby odbiorców. Przedstawiono również przykład działania takiej automatyki. W drugiej części artykułu zaprezentowano kluczową rolę funkcji szybkiej lokalizacji miejsca zwarcia oraz możliwości zdalnej rekonfiguracji sieci SN w celu poprawy niezawodności zasilania (poprawy wskaźników SAIDI, SAIFI). Pokazano również, jak wzrost liczby punktów wyposażonych w układy wykrywające przepływ prądów zwarciowych wraz z możliwością zdalnego sterowania łącznikami z systemu dyspozytorskiego w sieci SN może wpłynąć na zmniejszenie wskaźników SAIDI i SAIFI w poszczególnych oddziałach Energa -Operator SA.
The paper presents the issue of comprehensive automation and monitoring of medium voltage (MV) grids as a key element of the Smart Grid concept. The existing condition of MV grid control and monitoring is discussed, and the concept of a solution which will provide the possibility of remote automatic grid reconfiguration and ensure full grid observability from the dispatching system level is introduced. Automation of MV grid switching is discussed in detail to isolate a faulty line section and supply electricity at the time of the failure to the largest possible number of recipients. An example of such automation controls’ operation is also presented. The paper’s second part presents the key role of the quick fault location function and the possibility of the MV grid’s remote reconfiguration for improving power supply reliability (SAIDI and SAIFI indices). It is also shown how an increase in the number of points fitted with faulted circuit indicators with the option of remote control of switches from the dispatch system in MV grids may affect reduction of SAIDI and SAIFI indices across ENERGA-OPERATOR SA. divisions.
Źródło:
Acta Energetica; 2012, 1; 57-63
2300-3022
Pojawia się w:
Acta Energetica
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Zależność między żywotnością polskich proweniencji buka (Fagus sylvatica L.) i dębów (Quercus robur L., Q. petraea (Matt.) Liebl.) a odczynem ich drewna
Autorzy:
Piętka, J.
Szczepkowski, A.
Tarasiuk, S.
Powiązania:
https://bibliotekanauki.pl/articles/1022163.pdf
Data publikacji:
2005
Wydawca:
Polskie Towarzystwo Leśne
Tematy:
hodowla lasu
Quercus petraea
Quercus robur
lesnictwo
dab szypulkowy
drewno bukowe
drewno debowe
buk zwyczajny
dab bezszypulkowy
proweniencje
zywotnosc
pH
Fagus sylvatica
drzewa lesne
fagus sylvatica
geographical location
quercus robur
quercus petraea
tree vitality
wood ph
Opis:
The acidity of beech (Fagus sylvatica L.) and oaks (Quercus robur L., Q. petraea (Matt.) Liebl.) wood was investigated in the context of varied crown vitality. Pairs of trees were compared, extracted from identical site and stand condition. Beech wood was sampled from 11 stands aged 80−145 years, representing 9 different Forest Districts from the entire Poland's beech distribution area. Oak wood was sampled from 13 stands aged 60−155 years, representing 12 Forest Districts. Beech wood acidity ranged 5.07−5.70, while that of oaks varied 3.40−4.26. No clear dependence between wood pH and tree vitality was found, noteworthy in the majority of analyzed pairs, the damaged tree wood was characterized by slightly lower pH.
Źródło:
Sylwan; 2005, 149, 03; 50-55
0039-7660
Pojawia się w:
Sylwan
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Impact of Slip Speed on the Wear Intensity of 38GSA and HARDOX 500 STEELS
Wpływ prędkości poślizgu na intensywność zużywania ściernego stali 38GSA I HARDOX 500
Autorzy:
Tarasiuk, W.
Napiórkowski, J.
Ligier, K.
Powiązania:
https://bibliotekanauki.pl/articles/189740.pdf
Data publikacji:
2018
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
slip speed
abrasive wear
wear intensity
prędkość poślizgu
zużycie ścierne
intensywność zużywania
Opis:
The study shows the results of experimental tests on the wear intensity of 38GSA and Hardox 500 steels in combination with a silicate material in relation to the slip speed. In order to reflect the actual working conditions, the counter sample was cut out of a 1NF class 15 silicate brick. The granulometric composition of the sand-lime mixture ranges from 0.1 to 5 mm. Slip speeds were selected to be close to the real conditions in which construction products and aggregates are transported.
W pracy przedstawiono wyniki badań eksperymentalnych dotyczących intensywności zużywania stali Hardox 500 i 38GSA w skojarzeniu z materiałem silikatowym w zależności od prędkości poślizgu. Aby oddać rzeczywiste warunki pracy, przeciwpróbka została wycięta z cegły silikatowej 1NF klasy 15. Skład granulometryczny mieszanki wapienno-piaskowej zawiera się w przedziale od 0,1 do 5 mm. Prędkości poślizgu dobrano tak, aby były zbliżone do realnych warunków, w których transportowane są wyroby budowlane i kruszywa.
Źródło:
Tribologia; 2018, 280, 4; 121-125
0208-7774
Pojawia się w:
Tribologia
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Impact of Signaling System Performance on QoE in Next Generation Networks
Autorzy:
Batalla, J. M.
Śliwiński, J.
Tarasiuk, H.
Burakowski, W.
Powiązania:
https://bibliotekanauki.pl/articles/308179.pdf
Data publikacji:
2009
Wydawca:
Instytut Łączności - Państwowy Instytut Badawczy
Tematy:
call setup delay
class of service
heterogeneous networks
next generation networks
quality of experience
quality of service
signaling system
Opis:
The first experience of quality by multimedia applications' users takes place during the setup phase of a new connection. If the setup phase is not accepted or "slowly accepted", the confidence of the user decreases. The user becomes more sensitive when he/she pays the connections with assured quality of service (QoS). In this case, the process of call request should be also accomplished with QoS guarantees. This paper presents the signaling sub-system implemented within the EuQoS system. The EuQoS signaling process follows main assumptions of next generation networks (NGN) architecture and performs tasks related with codec agreement between multimedia end users, admission control and resource reservation functions. In this paper, we present analytical, simulation and experimental results showing the impact of signaling system performance on quality of experience (QoE) for the potential users of multi-layer EuQoS system. In particular, the presented approach aims at ensuring user QoE of the connection setup phase by ensuring QoS for transferring signaling messages by the network.
Źródło:
Journal of Telecommunications and Information Technology; 2009, 4; 124-137
1509-4553
1899-8852
Pojawia się w:
Journal of Telecommunications and Information Technology
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wear Resistance of Steel 20MnCr5 After Surfacing with Micro-jet Cooling
Autorzy:
Tarasiuk, W.
Piwnik, J.
Węgrzyn, T.
Sieteski, D.
Powiązania:
https://bibliotekanauki.pl/articles/380473.pdf
Data publikacji:
2016
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
tribological properties
welding
micro-jet
steel 20MnCr5
właściwości tribologiczne
spawanie
mikrojety
stal 20MnCr5
Opis:
This paper presents results of experimental research concerning the impact of an innovative method of micro-jet cooling on the padding weld performed with MIG welding. Micro-jet cooling is a novel method patented in 2011. It enables to steer the parameters of weld cooling in a precise manner. In addition, various elements which may e.g. enhance hardness or alter tribological properties can be entered into its top surface, depending on the applied cooling gas. The material under study was steel 20MnCr5, which was subject to the welding process with micro-jet cooling and without cooling. Nitrogen was used as a cooling gas. The main parameter of weld assessment was wear intensity. The tests were conducted in a tribological pin-on-disc type position. The following results exhibit growth at approximately 5% in wear resistance of padding welds with micro-jet cooling.
Źródło:
Archives of Foundry Engineering; 2016, 16, 3; 121-124
1897-3310
2299-2944
Pojawia się w:
Archives of Foundry Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Influence of the impact angle of a solid particle jet on the erosion wear of 38GSA and HARDOX 500 steel
Wpływ kąta padania strumienia cząstek stałych na zużycie erozyjne stali 38GSA i HARDOX 500
Autorzy:
Krupicz, B.
Tarasiuk, W.
Napiórkowski, J.
Ligier, K.
Powiązania:
https://bibliotekanauki.pl/articles/188297.pdf
Data publikacji:
2017
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
erozja cząstkami stałymi
praca odkształcenia
stal 38GSA
stal Hardox 500
solid particle erosion
deformation
38GSA steel
Hardox 500 steel
Opis:
W pracy dokonano analizy wpływu kąta padania strumienia cząstek stałych na zużycie erozyjne stali 38GSA i Hardox 500. Podstawą analizy było założenie istnienia korelacji między szybkością erozji i właściwościami mechanicznymi materiału reprezentowanymi przez pracę odkształcenia (W0) wyznaczoną z wykresu rozciągania do zerwania i udarność (U). Kąt padania cząstek piasku kwarcowego (30, 60 i 90°) uwzględniano poprzez rozdzielenie energii kinetycznej atakujących cząstek na kierunek prostopadły i styczny do powierzchni erodowanej.
The paper investigated the influence of the impact angle of a solid particle jet on the erosion wear of 38GSA and Hardox 500 steel. The basis of the analysis was the assumption of the existence of a correlation between mechanical properties of the material, represented by the work of deformation (P) determined from the stressstrain diagram (U). The impact angle of quartz sand particles (30, 60, and 90 °) was considered through the separation of kinetic energy of particles impacting the eroded surface perpendicularly and tangentially.
Źródło:
Tribologia; 2017, 273, 3; 85-90
0208-7774
Pojawia się w:
Tribologia
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Comparison of the wear resistance of Hardox 500 steel and 20MnCr5
Porównanie odporności na zużywanie ścierne stali Hardox 500 i 20MnCr5
Autorzy:
Tarasiuk, W.
Napiórkowski, J.
Ligier, K.
Krupicz, B.
Powiązania:
https://bibliotekanauki.pl/articles/191094.pdf
Data publikacji:
2017
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
Hardox 500
20MnCr5
wear
zużycie
Opis:
The paper presents the results of experimental studies on abrasion resistance of Hardox 500 steel and 20MnCr5 steel subjected to thermo-chemical treatment. These types of steel are often used for agricultural or construction machinery. Abrasion tests were performed on a T-11 pin using a disc tester. The test conditions correspond to the wear caused by micro-grinding and grain-cutting using particles from the product as well as a result of abrasion produced by loose abrasive material created through the chipping of silica sand grains. The obtained results can be useful in the selection of materials for machine components.
W pracy przedstawiono wyniki badań eksperymentalnych dotyczących odporności na zużywanie ścierne stali Hardox 500 i stali 20MnCr5 poddanej obróbce cieplno-chemicznej. Stale te często stosuje się na elementy maszyn rolniczych lub budowlanych pracujących w glebie lub kontaktujących się z innymi materiałami ściernymi. Testy ścieralności wykonano na testerze typu trzpień-tarcza T-11, a parę cierną stanowił zespół stal-silikat. Warunki testu odpowiadają zużywaniu na skutek mikroskrawania i bruzdowania ziarnami będącymi częścią wyrobu oraz na skutek ścierania przez luźne ścierniwo powstające w wyniku wykruszania się ziaren piasku z silikatu. Uzyskane wyniki mogą być pomocne przy doborze materiałów na elementy maszyn.
Źródło:
Tribologia; 2017, 273, 3; 165-170
0208-7774
Pojawia się w:
Tribologia
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Koncepcja nowej metody oceny jakości energii elektrycznej
Concept of New Method of Power Quality Assessment
Autorzy:
Gnaciński, P.
Mindykowski, J.
Pepliński, M.
Tarasiuk, T.
Powiązania:
https://bibliotekanauki.pl/articles/1368696.pdf
Data publikacji:
2013
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Napędów i Maszyn Elektrycznych Komel
Tematy:
jakość energii elektrycznej
maszyny indukcyjne
temperatura uzwojeń
power quality
induction machines
winding temperature
Opis:
The paper presents a concept of a new method of power quality assessment dedicated for ship power systems. The method is based on estimation of thermal loads of an induction machine under simultaneous presence of various power quality disturbances: voltage deviation, frequency deviation, voltage unbalance, voltage harmonics, subharmonics and interharmonics. The variation in time of power quality disturbances and machines thermal transients will be taken into account. The method will be verified on the grounds of assessed average rate of thermal ageing of insulation systems of induction motors supplied with voltage of lowered quality. The new method might be implemented in power quality analyzers as well as in power quality standards and regulation of ship classification societies.
Artykuł dotyczy nowej koncepcji oceny jakości napięcia w okrętowych systemach elektroenergetycznych. Opracowanie nowej metody oparte będzie na ocenie obciążeń cieplnych silników indukcyjnych, w warunkach jednoczesnego występowania różnych zaburzeń jakości napięcia: odchylenia napięcia i częstotliwości, asymetrii napięcia, harmonicznych, subharmonicznych i interharmonicznych napięcia. Zostaną uwzględnione zarówno zmienność w czasie zaburzeń jakości napięcia, jak również cieplne procesy przejściowe w maszynach indukcyjnych. Metoda zostanie zweryfikowana na podstawie szacunkowej średniej szybkości starzenia cieplnego układów izolacyjnych silników indukcyjnych w warunkach zasilania napięciem o zaniżonej jakości. Przewidziano zastosowanie prezentowanej metody w analizatorach jakości napięcia oraz w normach dotyczących jakości napięcia i przepisach okrętowych towarzystw klasyfikacyjnych.
Źródło:
Maszyny Elektryczne: zeszyty problemowe; 2013, 4, 100/2; 37-41
0239-3646
2084-5618
Pojawia się w:
Maszyny Elektryczne: zeszyty problemowe
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Diagnostyka izolowanego systemu elektroenergetycznego na przykładzie jednostki pływającej
Diagnostics of isolated electrical power system on example of the ship
Autorzy:
Mindykowski, J.
Tarasiuk, T.
Szmit, E.
Czarkowski, D.
Powiązania:
https://bibliotekanauki.pl/articles/327684.pdf
Data publikacji:
2006
Wydawca:
Polska Akademia Nauk. Polskie Towarzystwo Diagnostyki Technicznej PAN
Tematy:
izolowany system elektroenergetyczny
jakość
energia elektryczna
zniekształcenia sygnałów
isolated electrical power system
electrical power quality
waveform distortions
Opis:
Publikacja omawia zaawansowane techniki diagnostyczne wykorzystywane do pomiarów jakości energii elektrycznej w izolowanych systemach elektroenergetycznych stosowanych na jednostkach pływających, małych wyspach, terenach zajętych przez strony walczące itp. W publikacji zawarto obserwacje poczynione podczas dotychczasowej współpracy oraz badań prowadzonych na trzech różnych obiektach pływających, z których jeden był tzw. all electric ship, gdzie podstawową część odbiorników energii elektrycznej stanowiły obwody nieliniowe, posiadające zasadniczy wpływ na parametry jakości energii elektrycznej.
Publication treats of advanced diagnostic technologies used for electrical power quality measurements in isolated electrical power systems, applied on ships, small islands, territories occupied by fighting sides, etc. Publication includes observations made during the present cooperation and tests carried out onboard three different ships, which one of them was all electric ship, where main part of power consumers were non-linear circuits having principle influence on the parameters of electrical power quality.
Źródło:
Diagnostyka; 2006, 2(38); 171-176
1641-6414
2449-5220
Pojawia się w:
Diagnostyka
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Shaft Wear After Surfacing with Micro-Jet Cooling
Zużycie ścierne wałów po napawaniu z chłodzeniem mikro-strugowym
Autorzy:
Węgrzyn, T.
Piwnik, J.
Wszołek, Ł.
Tarasiuk, W.
Powiązania:
https://bibliotekanauki.pl/articles/352511.pdf
Data publikacji:
2015
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
welding surfacing
micro-jet cooling
metallographic structure
wearing
napawanie powierzchni
chłodzenie mikrojetowe
metalograficzne struktury
Opis:
A paper presents a piece of information about innovate surfacing technology with micro-jet cooling. There are put down information about parameters of shaft surfacing with micro-jet cooling process. There were given information about influence of various micro-jet gases on metallographic structure of machine shaft after surfacing. There were analyzed tribological properties of welds. Welding surfacing process is very often used to apply a hardness or wear-resistant layer of base metal. It is very important method of extending the life of machines, tools, and construction equipment. Surfacing is also known as wearfacing, is often used to build up shafts, gears or cutting edges. Regenerated surface properties of various machine elements do not provide good tribological properties. The tribological interactions of a solid shaft surfaces were tested after welding with micro-jet cooling.
W artykule przedstawiono informację na temat innowacyjnej technologii nawania z chłodzeniem mikro-strugowym. Przedstawiono informacje na temat parametrów napawania wału maszynowego z chłodzeniem mikro-strugowym. Podano informację na temat doboru różnych gazów stosowanych w chłodzeniu mikro-strugowym i ich wpływ na strukturę metalograficzną napawanego wału. Analizowano właściwości tribologicznych spoin. Powierzchniowy proces spawania jest bardzo często używany do podniesienia twardości i odporności na zużycie warstwy metali. Jest to także bardzo ważna metoda pozwalająca na przedłużenie czasu eksploatacji elementów maszyn i elementów konstrukcji. Napawanie powierzchniowe jest również stosowane w wytwarzaniu wałów, przekładni, krawędzi tnących, itp. Regenerowane powierzchnie różnych elementów maszyn nie zawsze posiadają dobre właściwości tribologiczne. W artykule analizowano wpływ chłodzenia mikro-strugowego na poprawę własności tribologicznych napawanych wałów maszynowych.
Źródło:
Archives of Metallurgy and Materials; 2015, 60, 4; 2625-2630
1733-3490
Pojawia się w:
Archives of Metallurgy and Materials
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Study of harmonic detection methods under non-ideal conditions in ship power network
Autorzy:
Xu, X.-Y.
Mindykowski, J.
Tarasiuk, T.
Cheng, C.
Powiązania:
https://bibliotekanauki.pl/articles/259840.pdf
Data publikacji:
2015
Wydawca:
Politechnika Gdańska. Wydział Inżynierii Mechanicznej i Okrętownictwa
Tematy:
distorted three-phase voltage
rapid-variation load
harmonic detection
average arithmetic
Opis:
An improved harmonic detection method based on average arithmetic is proposed. According to the research results, the designed solution uses an LPF (low-pass-filter) and a mean value module connected in series instead of the conventional mean value module, and simultaneously, a three-phase voltage phase-locked module instead of commonly used PLL (phase lock loop) module is applied in order to reduce the influence caused by three-phase distorted voltage and rapid variation of load. The experimental results show that the application of this solution leads to increase in the accuracy of harmonics detection for distorted three-phase voltage and rapid variation of load.
Źródło:
Polish Maritime Research; 2015, 3; 82-89
1233-2585
Pojawia się w:
Polish Maritime Research
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies