Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "Szczesio, M." wg kryterium: Autor


Wyświetlanie 1-3 z 3
Tytuł:
The effect of bottom sediments on the content of heavy metals in meadow soils
Autorzy:
Kabzińska, K.
Szczesio, M.
Świętosławski, J.
Turek, A.
Powiązania:
https://bibliotekanauki.pl/articles/184612.pdf
Data publikacji:
2015
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie. Wydawnictwo AGH
Tematy:
soil
bottom sediment
anthropogenic fractions of metals
AAS method
Opis:
The objects of the study were grasslands situated along the watercourse that collect matter directly from surface runoff from the surrounding fields and ditches. Therefore, the chemical composition of the bottom sediments can be varied. The aim of the study was to determine the content of anthropogenic fractions of selected heavy metals in meadow soils where the material from the watercourse maintenance was stored. Soil samples were collected along the banks of the Witonia “A” Channel (soil with sediment), and 30 meters from the watercourse (soil without sediment). The pH of soils without sediment was in the range 6.2–6.6, whereas the soil with sediment had a pH ≥ 7.0. The content of organic matter was 5.7–31.5%. The concentration of anthropogenic fractions of elements was determined by atomic absorption spectrometry after extraction with a (1 + 4) HCl solution. The anthropogenic enrichment coefficients (AEC) calculated in relation to the geochemical background level, were within the range: 0.9–2.8 for Zn, 1.2–3.5 for Cu, 0.7–3.1 for Pb, 1.0–2.8 for Ni and 0.3–0.9 for Cd. The AEC values for lead, copper, cadmium and nickel were usually higher in samples without sediment. A significant correlation between the metal and organic content ( R2 = 0.7–0.9) was found. On two sites, the level of heavy metals under investigation shows a significant local influence from anthropogenic pressure.
Źródło:
Geology, Geophysics and Environment; 2015, 41, 1; 25-32
2299-8004
2353-0790
Pojawia się w:
Geology, Geophysics and Environment
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Modyfikacja światłoutwardzalnego kompozytu stomatologicznego wybranymi poliedrycznymi oligomerycznymi silseskwioksanami
Modification of light-curable dental composite with selected polyhedral oligomeric silsesquioxanes
Autorzy:
Bociong, K.
Krasowski, M.
Szczesio, A.
Anyszka, R.
Kalicka, K.
Sokołowski, J.
Powiązania:
https://bibliotekanauki.pl/articles/947090.pdf
Data publikacji:
2018
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Chemii Przemysłowej
Tematy:
kompozyty stomatologiczne
poliedryczne oligomeryczne silseskwioksany
modyfikacja
dental composites
polyhedral oligomeric silsesquioxane
modification
Opis:
Komercyjny światłoutwardzalny kompozyt stomatologiczny GrandioSO Flow poddano modyfikacji za pomocą wybranych poliedrycznych oligomerycznych silseskwioksanów zawierających grupy metakrylowe (M-POSS) lub akrylowe (A-POSS). Fotopolimeryzację z wykorzystaniemdiodowej lampy o mocy rzeczywistej 1400 mW/cm2 prowadzono przez 60 s w sposób ciągły z jednej strony próbki. Naprężenia generowane w wypełnieniu obliczano na podstawie wzorów teorii sprężystości. Oceniano również efektywność polimeryzacji i właściwości mechaniczne spolimeryzowanych kompozytów, m.in. średnicową wytrzymałość na rozciąganie, wytrzymałość na trójpunktowe zginanie oraz mikrotwardość metodą Vickersa. Stwierdzono, że najmniejsze naprężenia skurczowe, wynoszące ~9 MPa, generuje kompozyt zmodyfikowany dodatkiem do osnowy 2% mas. M-POSS lub 5% mas. A-POSS. Modyfikacja prowadzi także do niewielkiego zmniejszenia twardości oraz wytrzymałości na trójpunktowe zginanie, z zachowaniem właściwej dla materiału niemodyfikowanego wartośc iDTS (DTS – diametral tensile strength) w wypadku materiału zawierającego 2% mas. M-POSS. Dodatek do żywicznej osnowy 5% mas. A-POSS wpływa na pogorszenie wszystkich właściwości wytrzymałościowych, wciąż jednak pozostają one na poziomie zadowalającym i porównywalnym do właściwości dostępnych na rynku materiałów typu flow.
The commercial light-curable dental composite Grandio SOFlow was subjected to modification with selected polyhedral oligomeric silsesquioxanes containing methacrylic (M-POSS) or acrylic (A-POSS) groups. Photopolymerization was carried out using LED lamp with a real power of 1400 mW/cm2 continuously for 60 s on one side of the sample.The stress generated by the filling was calculated on the basis of the elasticity theory. The polymerization efficiency and mechanical properties of polymerized composites were also evaluated, including diametral tensile strength (DTS), three-point bending strength and Vickers microhardness. It was found, that the lowest shrinkage stress of ~ 9 MPa was generated by the composite modified with 2 wt % M-POSS or 5 wt % A-POSS. The modification also leads to a slight decrease in hardness and three point flexural strength, while maintaining a comparable DTS value of a material containing 2 wt % M-POSS. In the case of modification with 5 wt % A-POSS, a decrease in all strength parameters is observed, but they still remain at a satisfactory level and are comparable to the properties of flow materials available commercially.
Źródło:
Polimery; 2018, 63, 7-8; 515-523
0032-2725
Pojawia się w:
Polimery
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Impact of modification with cetylpyridinium chloride – a potential cariogenic microflora inhibitor, on selected physical-mechanical properties of the water-activated glass-ionomer
Autorzy:
Kupka, T.
Nowak, J.
Szczesio, A.
Kopacz, K.
Fronczek-Wojciechowska, M.
Sokolowski, J.
Powiązania:
https://bibliotekanauki.pl/articles/307009.pdf
Data publikacji:
2018
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
twardość
wytrzymałość na rozciąganie
szkło
hardness
diametral tensile strength
glass-ionomer
Opis:
Teeth caries is one of predominant civilization diseases. Dental fillings with antimicrobial addition might allow prevention of secondary caries. The purpose of this study was to evaluate hardness and tensile strength of cetylpyridinium chloride modified water activated glass-ionomer cement. Methods: Samples with diameter of 6 mm and height of 3 mm made of water-activated glass-ionomer cement were control group (0.0%). Test groups were series of samples of the same dimensions, with addition of cetylpyridinium chloride antibacterial in concentrations of 0.5, 1.0, 1.5 and 2.0%. Two subgroups were prepared in each group to determine Vickers Hardness and Diametral Tensile Strength after 1 and 24 hours of sample storage in distilled water. Results: During hardness studies, no strong effect of antibacterial concentration on hardness of samples was observed. Higher hardness values after 24 hours were demonstrated for all groups, compared to the samples tested after 1 hour. The exception was the group with the addition of 1% cetylpyridinium chloride, in which no statistically significant differences were observed. Diametral Tensile Strength values for samples tested after 1 hour decreased with increasing antibacterial concentration. A similar relationship was noticed for samples tested after 24 hours. No statistically significant differences were found between test samples after 1 or 24 hours. Conclusions: There was no significant effect of cetylpyridinium chloride concentration on the hardness of the samples that significantly increased during the study. With the increase in antibacterial concentration a decrease in diametral tensile strength value was observed, but these values did not change over time.
Źródło:
Acta of Bioengineering and Biomechanics; 2018, 20, 3; 19-24
1509-409X
2450-6303
Pojawia się w:
Acta of Bioengineering and Biomechanics
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-3 z 3

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies