Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "Szabo, D." wg kryterium: Autor


Wyświetlanie 1-4 z 4
Tytuł:
Stimulation of unconventional hydrocarbon reservoirs
Autorzy:
Szabo, D.
Pinka, J.
Stolićny, E.
Powiązania:
https://bibliotekanauki.pl/articles/299289.pdf
Data publikacji:
2014
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie. Wydawnictwo AGH
Tematy:
Tight gas sand
shale gas
coal bed seam unconventional
intensification
fracturing
propant
mesh
Darcy’s law
Opis:
In the "new age" oil and gas industry came more and more into focus term of unconventional hydrocarbons. Gained experience and success in the United States tight gas sand reservoirs Piceance, Anadarko, Greater Green, Lobo fields confirmed the hidden potential of unconventional hydrocarbon resources. In some production and development areas called coal bed seam, shale gas and tight sand reservoirs without intensifying operations isn't possible to produce commercial gas volumes. Used practises and gained large experiences in the crude oil fields are commonly used in the shale and tight gas fields across the United States. Application of these technologies of stimulation methods like fracturing in Europe is at the very beginning. Pioneer investors are waiting in all Europe for the well testing results from the first dozen fractured shale gas and tight sand reservoirs. Test results could have significant influence on the future planned massive drilling campaign of exploration of the unconventional hydrocarbon resources
Źródło:
AGH Drilling, Oil, Gas; 2014, 31, 2; 307-313
2299-4157
2300-7052
Pojawia się w:
AGH Drilling, Oil, Gas
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
UGS wells in depleted fields
Podziemne magazyny gazu zlokalizowane na sczerpanych złożach węglowodorów
Autorzy:
Szabo, D.
Pinka, J.
Fedorko, L.
Powiązania:
https://bibliotekanauki.pl/articles/299404.pdf
Data publikacji:
2011
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie. Wydawnictwo AGH
Tematy:
podziemne magazyny gazu
Underground Gas Storage (UGS)
logging
Open Hole
closed loop system
sand control
Opis:
The Underground Gas Storage (UGS) facilities are mainly built in hydrocarbon reservoirs (depleted oil and gas fields), in aquifers and also in salt caverns using proven techniques based on the best use of geology and geophysics. From the international perspective, Slovakia plays an important role in the European gas industry. Transporting one-fifth of the natural gas consumed in western European countries, it is one of the largest natural gas transit countries. Before the end of its path across Slovakia, the transported natural gas reaches the Lab UGS facility in the Slovakia. This paper describes oil and gas depleted reservoirs and techniques that apply in the UGS field.
Podziemne magazyny gazu (PMG) lokalizowane są głównie na sczerpanych złożach węglowodorów lub w kawernach solnych z wykorzystaniem sprawdzonych technik bazujących na osiągnięciach geologii i geofizyki. W niniejszej pracy opisano czerpane złoża ropy naftowej i gazu ziemnego oraz techniki stosowane w PMG na Słowacji.
Źródło:
Wiertnictwo, Nafta, Gaz; 2011, 28, 1-2; 411-417
1507-0042
Pojawia się w:
Wiertnictwo, Nafta, Gaz
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The effects of uninsulated sewage tanks on groundwater. A case study in an eastern Hungarian settlement
Oddziaływania nieizolowanych zbiorników ściekowych na wody gruntowe. Przykład osiedla ze wschodnich Węgier
Autorzy:
Mester, T.
Szabo, G.
Bessenyei, E.
Karancsi, G.
Barkoczi, N.
Balla, D.
Powiązania:
https://bibliotekanauki.pl/articles/946930.pdf
Data publikacji:
2017
Wydawca:
Instytut Technologiczno-Przyrodniczy
Tematy:
ammonium
groundwater contamination
groundwater level
modelling
pollution
wastewater
jony amonowe
modelowanie
poziom wód gruntowych
ścieki
zanieczyszczenie
zanieczyszczenie wód gruntowych
Opis:
In our study we attempt to demonstrate the effects of uninsulated sewage tanks, which are the most important sources of contamination in settlements without sewage systems, on groundwater quality. We compared the results of measurements carried out before and one and a half years after the construction of the sewage system. We established 3 m deep monitoring wells within a 25 m radius of a sewage tank, which were then sampled, and the level of groundwater was recorded. The 3D model constructed on the basis of the saturated zone shows that the effluent wastewater formed a groundwater level dome with a height of more than 1 m. After the sewage tank was taken out of use the difference between the highest and lowest groundwater levels decreased to a few centimetres. In our study we investigated the spatial distribution of NH4 + (ammonium). Using the 3D model we were able to precisely determine the volume of water bodies with different levels of contamination. In an approximately 25 m3 water body, in the immediate environment of a sewage tank in use we detected NH4 + at a concentration which was characteristic of undiluted wastewater (>90 mg∙dm–3). After the sewage tank was taken out of use, the concentration in its immediate environment decreased by more than 50%, although almost everywhere in the modelled area concentrations were measured above the limit value. Based on the above, we can conclude that the cleaning process has started, but the complete decontamination of the groundwater will take several years.
W pracy podjęto próbę wykazania wpływów nieizolowanych zbiorników ściekowych, które są głównym źródłem zanieczyszczenia w osiedlach pozbawionych kanalizacji, na jakość wód gruntowych. Porównano wyniki pomiarów prowadzonych przed i półtora roku po zbudowaniu systemu kanalizacyjnego. W promieniu 25 m od zbiornika ściekowego zainstalowano studzienki o głębokości 3 m, z których pobierano próbki i mierzono w nich poziom wód gruntowych. Na podstawie trójwymiarowego modelu zbudowanego ze znajomością strefy saturacji stwierdzono, że wypływające ścieki uformowały wypukłe zwierciadło wód gruntowych o wysokości ponad 1 m. Po wyłączeniu zbiornika ścieków z eksploatacji różnica pomiędzy najwyższym i najniższym poziomem wód gruntowych zmalała do kilku centymetrów. W przedstawionych badaniach analizowano przestrzenne rozmieszczenie jonów amonowych (NH4 +). Stosując trójwymiarowy model można było precyzyjnie określić objętość wody o różnym stopniu zanieczyszczenia. W 25 m3 wody w bezpośrednim otoczeniu używanego zbiornika ściekowego wykryto jony amonowe w stężeniu typowym dla nierozcieńczonych ścieków (>90 mg∙dm–3). Po wyłączeniu zbiornika z eksploatacji stężenie to zmalało o ponad 50%, choć niemal wszędzie nadal przekraczało dopuszczalne normy. Na podstawie uzyskanych wyników można wnioskować, że proces oczyszczania został rozpoczęty, ale całkowita dekontaminacja zajmie kilka lat.
Źródło:
Journal of Water and Land Development; 2017, 33; 123-129
1429-7426
2083-4535
Pojawia się w:
Journal of Water and Land Development
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Point-Contact Spectroscopy of Superconducting $MgCNi_3$ Single Crystals
Autorzy:
Pribulová, Z.
Szabó, P.
Kačmarčík, J.
Samuely, P.
Jang, D.
Lee, H.
Lee, S.
Powiązania:
https://bibliotekanauki.pl/articles/1813611.pdf
Data publikacji:
2008-01
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Tematy:
74.50.+r
Opis:
The first point-contact spectroscopy measurements on $MgCNi_3$ single crystals of very good quality are presented. The measurements have been performed in the temperature range from 1.5 K up to 10 K and at magnetic fields up to 6 T. The superconducting energy gap Δ of the system is found to be scattered between 1 and 1.2 meV which gives the 2Δ/k $T_c$ ratio between BCS weak-coupling value of ~3.5 and a strong coupling of about 4.2. The excess current evaluated in magnetic field indicates the presence of a single energy gap.
Źródło:
Acta Physica Polonica A; 2008, 113, 1; 215-218
0587-4246
1898-794X
Pojawia się w:
Acta Physica Polonica A
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-4 z 4

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies